PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Tissue Expansion Devices”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

Activity of antimicrobial-impregnated silicone tissue expanders.

Because bacterial colonization of medical devices may result in clinical infection, it is conceivable that antimicrobial impregnation of tissue expanders may reduce the rate of infection. The objective of this in vitro study was to examine the spectrum, durability, and shelf-life antimicrobial activity of minocycline/rifampin-impregnated silicone tissue expander shells. The impregnated devices exhibited zones of inhibition at baseline against Staphylococcus epidermidis, Staphylococcus aureus, and Escherichia coli. The impregnated devices exhibited strong residual activity against S. epidermidis and S. aureus after suspension in serum at 37 degrees C for 4 weeks. There was no significant decrease in the size of zones of inhibition after storing the impregnated devices at room temperature for 1 year. These results indicate that minocycline/rifampin-impregnated tissue expander shells provide broad-spectrum and durable antimicrobial activity and that the shelf-life antimicrobial activity exceeds 1 year. These findings prompt future exploration of the anti-infective efficacy of these antimicrobial-impregnated devices.

Anti-Bacterial Agents↗

[Indications for the use of a skin-stretching device].

In the management of surgical or traumatic skin loss the Authors consider an alternative method which involves the use of a tool called skin stretching device. The latter seems easy to apply, atraumatic and the least troublesome for the isolation and detaching of tissues employed in skin repair.

Back↗

Use of an external skin-stretching device for wound closure in dogs and cats.

Use of an externally applied, noninvasive skin-stretching device in 24 dogs and cats is described. The device uses adhesive-coated pads that are applied to the skin of an animal; pads are positioned on opposite sides of a surgical site and are connected by means of adjustable elastic cables. The cables maintain continuous tension, and cable tension is adjusted and progressively increased at intervals of 6 to 8 hours to promote skin recruitment (stretching), using the cutaneous viscoelastic properties of mechanical creep and stress relaxation. Consequently, skin adjacent and distant to the surgical site can be recruited to facilitate wound closure, typically within 72 to 96 hours after application of the device. The skin-stretching device has been used effectively in dogs and cats to stretch skin prior to elective surgical procedures, stretch skin during management of open wounds prior to suturing, and alleviate incisional tension after surgery.

Animals↗

Breast reconstruction with implants and expanders.

Breast reconstruction with expanders and implants provides an excellent option in the properly selected patient. Techniques for reconstruction have evolved significantly over the past 30 years with the development of more sophisticated devices and improvement in surgical procedures. Several options exist, each with its own advantages and disadvantages. Two-stage breast reconstruction using a textured device with an anatomic shape and integrated valve seems to provide the most consistent and reproducible results in most patients. Those patients with small, minimally ptotic breasts may be candidates for either single-stage implant reconstruction or reconstruction with an adjustable device. Advantages of expander and implant reconstruction over other techniques include relative ease of the procedure; no distant donor-site morbidity; use of tissue of similar color, texture, and sensation; reduced operative time; and more rapid postoperative recovery.

Adult↗

Use of expanders for protection of viscera during irradiation of pelvic tumors in children.

The authors describe a new technique for radioprotection of pelvic viscera by placement of expanders in the subperitoneal area before irradiation of pelvic tumors. They use round shape sub-cutaneous expanders, the volume corresponding to children's weight. Seven patients were treated with excellent results, and minor complications: 2 rectitis due to unsatisfactory displacement of rectum by the balloon. There were no complications related to the device itself. The prosthesis was easy to withdraw. This method seems a safe and effective technique in protecting viscera.

Acetabulum↗

[Gain of skin in severe facial malformations].

In some cases of facial deformities, devices have been designed to promote bone growth: intraorbital spherical expander for microphthalmia, bone distractors for micrognathia, in oto-mandibular syndromes, but when the various treatment technique are carefully compared, the superiority of these procedure is linked to the gradual gain of skin and they can then be assimilated to a skin expansion procedure.

Ear↗

Improved mammographic imaging using tissue expanders for breast augmentation.

Several studies indicate that mammographic evaluation of the breast is inhibited by both submammary and submuscular implants, regardless of implant composition. Two hundred radiographs were evaluated following subpectoral placement of 25 combination gel/saline and 25 saline-filled tissue expanders. Within 3 months after augmentation, mammograms were performed using the standard and displacement techniques; patients with inflated implants were followed by a repeat displacement study (with the expander deflated). After completion of the mammogram, expanders were reinflated. Our experience demonstrates that better visualization of breast tissue may be accomplished by implant-deflated views in patients with small amounts of breast tissue, tight skin envelopes, or capsular contraction. In each of these circumstances, the displaced view failed to adequately demonstrate glandular tissue. The presence of the inflated implant impairs mammographic visualization in a number of ways, including implant opacity, impaired automatic exposure control, interference with breast compressibility, and implant displacement. These effects are consistently present in small breasts (< an estimated 300 g), in breasts with grade III or IV capsular contracture, and in breasts with minimal skin laxity (i.e., nonptotic breasts). Breast compression was compromised to a greater degree in the presence of grade III and IV capsular contracture; however, deflation of an adjustable implant optimized radiographic interpretation to a high degree. The deflatable saline implant yields a less obscured evaluation of the augmented breast. We suggest that an extended-use deflatable device (i.e., tissue expander) be considered as an option in our search for a safe and reliable implant for augmentation mammoplasty, particularly in patients with small breasts, tight skin envelopes, or a propensity for capsular contracture.

Breast Implants↗

The use of a prosthetic tissue expander to displace bowel from a brachytherapy implant site.

We describe the use of a prosthetic maneuver to displace bowel from an implant site. The patient presented with a recurrent low grade fibrosarcoma which was grossly excised with positive microscopic margins in the right paravertebral area. For this reason we performed an Iridium-192 implant using afterloading catheters. Because of several dense adhesions, it was not possible to mobilize an omental sling over the implant site. To prevent the small bowel from lying on the catheters, we inserted a prosthetic breast tissue expander. This was expanded with saline and bacitracin solution and placed in the tumor bed overlying the catheters, thereby displacing the small bowel away from the sources. A postoperative CT scan with gastrograffin demonstrated that this procedure was effective. There were no complications. We conclude that such devices are suitable for use under these circumstances and can achieve the objective of decreasing the dose of radiation to the small bowel.

Abdominal Neoplasms↗

[Repair of skin defects by skin extension procedures].

The repair of defects by skin extension involves various procedures which are thoroughly described by the author. Skin extension is an original concept reflecting the viscoelastic properties of the skin and histological changes. It is based on 3 phenomena: "mechanical creep", "stress relaxation" and mobility of the skin. Although the various skin extension procedures present many advantages concerning the application and removal of the device, the conduct and monitoring of treatment as well as closure of the defect, its disadvantages must not be ignored. They are related to the material and to local conditions. The indications for skin extension are fairly wide. However, its ideal indication consists of closure of skin defects with loss of skin capital.

Dermatologic Surgical Procedures↗

Fungal growth within a silicone tissue expander: case report.

Fungal contamination of tissue expanders has not previously been reported. There are, however, reports of fungi in association with inflatable breast prostheses. Colonisation of a tissue expander with Aspergillus niger resulting in mechanical obstruction of the device is described. The possible modes of inoculation and survival of the organism within the expander envelope were studied including an investigation of the permeability to gases of the silicone expander envelope. Recommendations are made about prevention of this complication.

Aspergillus niger↗

Preoperative non-surgical over-correction of cleft lip nasal deformity.

Alar cartilage, which is elastic like auricular cartilage, is correctable in the early neonatal period. Taking advantage of this correctability, we have performed preoperative non-surgical over-correction for cleft lip nasal deformity of incomplete and complete cleft lips with a Simonart's band. The device for this correction was made by processing a nostril retainer into a nostril over-corrector which utilises a spring of silicone rubber, works like a tissue expander and is supported by the nostril floor. Twenty cases are reviewed whose follow-up lasted more than 19 months. The earlier the non-surgical over-correction began, the more satisfactory were the results that were obtained.

Cleft Lip↗

The effects of scalp expansion on the cranial bone: a clinical, histological, and instrumental study.

The effects of chronic compression of the cranial bone due to progressive expansion of the scalp have been investigated. Ten patients were studied, 6 adults and 4 children, who were treated for congenital (microtia) or acquired (burns or traumatic) deformities by chronic expansion over a 2-month period. All underwent computed tomography scans of the expansion site prior to introduction of the expansion device, immediately before removal, and at 9 months after the operation. A case of postburn alopecia was lost to the study, because the patient, who had ultimated scalp expansion, did not return for flap advancement. Instead, she came back 3 months later, without the expander, which had been removed at another institution following an automobile accident. In this case, because of slower healing, we performed computed tomography scans 18 months postoperation. During the second procedure (expander removal and flap transposition), bone samples for histological examination were collected directly underneath and along the perimeter of the expanders. Macroscopically, the bone appeared thinned and had a reduced convexity. This reaction, although temporary, appeared more intense in the children and in the posttraumatic cases. Histological examination showed osteoclastic activation, bony hypotrophy, and reaction (deposition of osteoid matrix) under the device, with consequent bone resorption and remodeling. A marked hyperplasia with a hyperostotic reaction was observed around the expanders. At 9 months postoperation, in most cases, a complete normalization was confirmed by computed tomography scans. Expansion of target (fontanellar and sagittal) areas of the skull in children, as well as previous trauma to both scalp and skull should be taken into consideration as a risk factor. Further investigations are suggested.

Adolescent↗

[The development of skin external expander and clinical applications].

The skin external expander that was designed and developed by the authors is a new device to produce extra skin tissue for the repair of defects by continuous traction over the skin. Clinical application in 38 cases since June 1993 have shown that the method has following advantages: easy in manipulation, unnecessary to bury the expander under the skin, safe and less complications with reliable effects. Accurate measurement of the expanded skin can be obtained with the method. Six months' follow-up of 18 cases demonstrated satisfying results.

Adolescent↗

[The development of a skin-stretching device and its clinical application].

A skin-stretching device that is designed to harness the elastic properties of the skin using incremental traction is presented. In using this device, the skin is stretched from its edges by direct linear traction. The device produces extra skin tissue rapidly, and no undermining is necessary to loosen skin, so as to close large areas of skin shortage that would otherwise have required more complicated procedures for their repair. It can be employed for a duration of 20-640 minutes, and be applied preoperatively, intraoperatively or postoperatively. 52 patients have undergone the treatment since March 1994. Six months to one year's follow-up of 27 cases demonstrated satisfactory results. The method has following advantages: easy in manipulation, saving time, safe and fewer complications.

Adolescent↗

Immediate breast reconstruction after mastectomy for cancer.

BACKGROUND: Immediate breast reconstruction after mastectomy has increased over the past decade following the unequivocal demonstration of its oncological safety and the availability of reliable methods of reconstruction. Broadly, it is undertaken in the treatment of breast cancer, after prophylactic mastectomy in high-risk patients, and in the management of treatment failure after breast-conserving surgery and radiotherapy. Immediate breast reconstruction can be achieved reliably with a variety of autogenous tissue techniques or prosthetic devices. Careful discussion and evaluation remain vital in choosing the correct technique for the individual patient. METHODS: This review is based primarily on an English language Medline search with secondary references obtained from key articles. RESULTS AND CONCLUSION: Immediate breast reconstruction is a safe and acceptable procedure after mastectomy for cancer; there is no evidence that it has untoward oncological consequences. In the appropriate patient it can be achieved effectively with either prosthetic or autogenous tissue reconstruction. Patient selection is important in order to optimize results, minimize complications and improve quality of life, while simultaneously treating the malignancy. Close cooperation and collaboration between the oncological breast and reconstructive surgeons is desirable in order to achieve these objectives.

Breast Implants↗

Subclinical infection of the silicone breast implant surface as a possible cause of capsular contracture.

In order to reexamine the possible association between bacterial presence and capsular contracture, 55 silicone devices (mammary implants or tissue expanders) were cultured at the time of their removal from 40 patients. Special culture techniques were used in an attempt to recover bacteria adhering to the smooth-surfaced implant and encased in glycocalyx biofilm. Bacteria were detected on 56% (15 of 27) of implants surrounded by contracted capsules and on 18% (5 of 28) of those without capsular contracture (p less than 0.05). Only three implants tested positive using routine plating techniques. The predominant isolate was Staphylococcus epidermidis. The concept that capsular contracture is associated with subclinical infection of silicone implants is supported by this study. With changes in the microbiological technique, bacterial recovery and growth occurs at a frequency greater than previously thought.

Adult↗

Dosimetry around metallic ports in tissue expanders in patients receiving postmastectomy radiation therapy: an ex vivo evaluation.

Postmastectomy breast reconstruction can be accomplished utilizing tissue expanders and implants. However, in patients who require postoperative radiotherapy, the complication rate with tissue expander/implant reconstruction can exceed 50%. One potential cause of this high complication rate may be the metallic port in the tissue expander producing altered dosimetry in the region of the metallic device. The purpose of this study was to quantify the radiation dose distribution in the vicinity of the metallic port and determine its potential contribution to this extremely high complication rate. The absolute dosimetric effect of the tissue expander's metallic port was quantified using film and thermoluminescent dosimetry (TLD) studies with a single beam incident on a metallic port extracted from an expander. TLD measurements were performed at 11 reproducible positions on an intact expander irradiated with tangential fields. A computed tomography (CT)-based treatment plan without inhomogeneity corrections was used to derive expected doses for all TLD positions. Multiple irradiation experiments were performed for all TLD data. Confidence intervals for the dose at TLD sites with the metallic port in place were compared to the expected dose at the site without the metallic port. Film studies did not reveal a significant component of scatter around the metallic port. TLD studies of the extracted metallic port revealed highest doses within the casing of the metallic port and no consistent increased dose at the surface of the expander. No excess dose due to the metallic port in the expander was noted with the phantom TLD data. Based upon these results, it does not appear that the metallic port in tissue expanders significantly contributes to the high complication rate experienced in patients undergoing tissue expander breast reconstruction and receiving radiation therapy. Strategies designed to reduce the breast reconstruction complication rate in this clinical setting will need to focus on factors other than adjusting the dosimetry around the tissue expander metallic port.

Breast Neoplasms↗

Volumetric analysis of small bowel displacement from radiation portals with the use of a pelvic tissue expander.

PURPOSE: Many techniques and devices have been used in an attempt to minimize gastrointestinal morbidity of pelvic irradiation. The value of a temporary intrapelvic tissue expander to displace small bowel from pelvic radiotherapy fields was analyzed by comparing volumetric treatment parameters of patients with and without such a device. METHODS AND MATERIALS: Between 1983 and 1991, 77 patients with a diagnosis of endometrial (n = 35), colorectal (n = 41), or anal carcinoma (n = 1) received adjuvant postoperative radiotherapy after undergoing treatment planning simulation with the use of small bowel oral contrast medium. Fourteen of these patients underwent surgical placement of a temporary intrapelvic tissue expander prior to radiotherapy, and 63 patients did not. Small bowel volume within the treatment portals was measured for both initial pelvic and conedown fields for all cases, and compared between the two patient groups. RESULTS: The volume of small bowel within the initial pelvic fields receiving full dose irradiation was significantly less among patients with a tissue expander. For patients with a tissue expander, mean volume receiving full dose irradiation was 25 cm3 (median 0 cm3, range 0-297 cm3), whereas the corresponding volume was 239 cm3 (median 181 cm3, range 0-943 cm3) without a tissue expander (p < .0001). A similar reduction of irradiated small bowel volume was noted in the conedown fields with the use of a tissue expander (p = .07). Volumes receiving less than full dose irradiation were also less within the initial pelvic (p = .0001) and conedown (p = .002) fields with a tissue expander. Multivariate analysis of patient and treatment-related parameters showed the use of a tissue expander to be the only factor correlated with decreased small bowel volume within the treatment field (p = .003). Morbidity related to placement and removal of the tissue expander was acceptable. Acute radiation-related morbidity was significantly less in patients irradiated with a tissue expander in place (p < .001). CONCLUSIONS: Placement of an intrapelvic tissue expander was correlated with decreased small bowel volume within the radiotherapy treatment field. Diminished radiation-induced acute gastrointestinal morbidity was noted with use of a tissue expander.

Aged↗