PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “WELDING”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

Design, construction, and characterization of a novel robotic welding fume generator and inhalation exposure system for laboratory animals.

Respiratory effects observed in welders have included lung function changes, metal fume fever, bronchitis, and a possible increase in the incidence of lung cancer. Many questions remain unanswered regarding the causality and possible underlying mechanisms associated with the potential toxic effects of welding fume inhalation. The objective of the present study was to construct a completely automated, computer-controlled welding fume generation and inhalation exposure system to simulate real workplace exposures. The system comprised a programmable six-axis robotic welding arm, a water-cooled arc welding torch, and a wire feeder that supplied the wire to the torch at a programmed rate. For the initial studies, gas metal arc welding was performed using a stainless steel electrode. A flexible trunk was attached to the robotic arm of the welder and was used to collect and transport fume from the vicinity of the arc to the animal exposure chamber. Undiluted fume concentrations consistently ranged from 90-150 mg/m(3) in the animal chamber during welding. Temperature and humidity remained constant in the chamber during the welding operation. The welding particles were composed of (from highest to lowest concentration) iron, chromium, manganese, and nickel as measured by inductively coupled plasma atomic emission spectroscopy. Size distribution analysis indicated the mass median aerodynamic diameter of the generated particles to be approximately 0.24 microm with a geometric standard deviation (sigma(g)) of 1.39. As determined by transmission and scanning electron microscopy, the generated aerosols were mostly arranged as chain-like agglomerates of primary particles. Characterization of the laboratory-generated welding aerosol has indicated that particle morphology, size, and chemical composition are comparable to stainless steel welding fume generated in other studies. With the development of this novel system, it will be possible to establish an animal model using controlled welding exposures from automated gas metal arc and flux-cored arc welding processes to investigate how welding fumes affect health.

Aerosols↗

Oxidant-antioxidant status and pulmonary function in welding workers.

Welding is a process during which fumes, gases, electromagnetic radiation and noise are emitted as by-products. Metal oxide particles are particularly hazardous components of welding fumes. Welding has been found to be associated with respiratory symptoms and our objective in the present study was to study the effects of welding on pulmonary function and serum oxidant-antioxidant status. Fifty-one welding workers and 31 control subjects were recruited. Face to face interviews were conducted using the respiratory illness questionnaire adapted from the American Thoracic Society with the addition of demographic characteristics, work history and working conditions. Additionally physical examinations and spirometric measurements were performed at workplaces. Thiobarbituric acid reactive substances (TBARS), protein carbonyls, protein sulfhydryls (SH) and erythrocyte reduced glutathione (GSH) levels were measured to evaluate oxidant-antioxidant status in 34 welding workers and in 20 control subjects. No statistically significant differences were observed in age, height, weight, body mass index (BMI), smoking status and annual working durations between welding workers and controls. Coughing, sputting and wheezing were significantly higher in welding workers (p<0.05). When adjusted for age, BMI and smoking status in logistic regression, welding work showed a significant risk for chronic bronchitis (OR: 4.78, 95%CI: 1.30-17.54). Forced expiratory volume in one second (FEV(1))/forced vital capacity (FVC) and four parameters of forced expiratory flow (FEF: FEF(25), FEF(50), FEF(75), FEF(25-75)) levels measured in the welding workers were significantly lower than those in the control group (p<0.05). Serum TBARS and protein carbonyl levels were higher in welding workers than those in controls (p<0.001, p<0.05, respectively). On the other hand, total protein SH groups and GSH levels were significantly lower in welders than those in controls (p<0.05, p<0.001, respectively). Pulmonary function tests and oxidant-antioxidant status were found to be negatively affected in welding workers chronically exposed to welding fumes and gases. Preventive measures should be taken to improve the health status of these workers.

Adult↗

Controlled temperature tissue fusion: Ho:YAG laser welding of rat intestine in vivo. Part two.

BACKGROUND AND OBJECTIVE: Temperature feedback control (TFC) during laser-assisted tissue welding was implemented to eliminate exponential increases in the rate of denaturation associated with rapidly increasing temperatures. This study was undertaken to investigate and compare the weld strengths and healing responses of laser welded enterotomies with and without TFC using a cw Ho:YAG laser and to examine the effects of wavelength on weld strength and histology. The Ho:YAG experimental results were compared with a similar study using cw argon ion laser irradiation. STUDY DESIGN/MATERIALS AND METHODS: An automated system was developed for temperature feedback controlled laser irradiation. An experimental device incorporating co-aligned laser delivery and temperature detection was used to perform cw Ho:YAG laser-welded enterotomies (with and without TFC). The weld strength and histology of laser welded and control sutured enterotomies were compared in an in vivo rat model (Ho:YAG, n = 42; argon, n = 41). Animals were sacrificed at 1, 3, 7, and 21 days postoperatively and the anastomotic site was removed for bursting/leaking pressure measurements and histological examination. RESULTS: Argon and Ho:YAG laser-welds with and without TFC and the control sutured anastomoses healed comparably, although wound abscesses were more prevalent in the Ho:YAG group leading to delay in mucosal healing. Laser-welded anastomoses without TFC were associated with more spontaneous ruptures and leaks (argon: 4/6 ruptures; Ho:YAG: 1/4 leak, 2/4 ruptures, & 1/3 stenosis) during the survival period than those with TFC (argon: 1/3 leak; Ho:YAG: 1/5 rupture). Bursting pressures of the Ho:YAG welds were weaker at 1 week than the argon welds, but by 3 weeks, laser welds and suture anastomoses were equally strong. CONCLUSION: From the spontaneous failure rates encountered, it is believed that TFC improves the quality and stability of laser-assisted enterotomy closures in surviving animals. However, TFC does not provide a satisfactory method to identify completion of a weld.

Anastomosis, Surgical↗

Studies on laser- and plasma-welded titanium.

In recent years, titanium has become a material of major interest in prosthetic dentistry. Due to its chemical properties, titanium has to be processed differently from conventional alloys. In this paper, two different methods of welding were investigated. Specimens machined from pure titanium rods were fused either by laser welding or plasma welding. Hardness profiles and light microscopy images were taken in the region of the weld. The mechanical properties were tested by alternating bending fatigue tests up to 3 million cycles. Light microscopy images and hardness profiles showed a larger heat-affected zone after plasma welding compared to laser welding. No significant differences comparing fatigue strength could be found between the two methods of welding. However, extreme loads led to earlier fatigue in the plasma-welded specimens. SEM images of the laser-welded joints showed fractures in the welding zone, while the plasma-welded specimens fractured mostly beyond the heat-affected zone. From these results, it can be assumed that both methods are suitable for welding titanium. At the moment, laser welding is the more suitable technique in dentistry because of its lower thermal alteration of the workpieces.

Dental Soldering↗

Structure and mechanical properties of Cresco-Ti laser-welded joints and stress analyses using finite element models of fixed distal extension and fixed partial prosthetic designs.

STATEMENT OF PROBLEM: The Cresco-Ti System uses a laser-welded process that provides an efficient technique to achieve passive fit frameworks. However, mechanical behavior of the laser-welded joint under biomechanical stress factors has not been demonstrated. PURPOSE: This study describes the effect of Cresco-Ti laser-welding conditions on the material properties of the welded specimen and analyzes stresses on the weld joint through 3-dimensional finite element models (3-D FEM) of implant-supported fixed dentures with cantilever extensions and fixed partial denture designs. MATERIAL AND METHODS: Twenty Grade III (ASTM B348) commercially pure titanium specimens were machine-milled to the dimensions described in the EN10002-1 tensile test standard and divided into test (n = 10) and control (n = 10) groups. The test specimens were sectioned and laser-welded. All specimens were subjected to tensile testing to determine yield strength (YS), ultimate tensile strength (UTS), and percent elongation (PE). The Knoop micro-indentation test was performed to determine the hardness of all specimens. On welded specimens, the hardness test was performed at the welded surface. Data were analyzed with the Mann-Whitney U test and Student's t test (alpha=.05). Fracture surfaces were examined by scanning electron microscopy to characterize the mode of fracture and identify defects due to welding. Three-dimensional FEMs were created that simulated a fixed denture with cantilever extensions supported by 5 implants (M1) and a fixed partial denture supported by 2 implants (M2), 1 of which was angled 30 degrees mesio-axially. An oblique load of 400 N with 15 degrees lingual-axial inclinations was applied to both models at various locations. RESULTS: Test specimens fractured between the weld and the parent material. No porosities were observed on the fractured surfaces. Mean values for YS, UTS, PE, and Knoop hardness were 428 +/- 88 MPa, 574 +/- 113 MPa, 11.2 +/- 0.4%, 270 +/- 17 KHN, respectively, for the control group and 642 +/- 2 MPa, 772 +/- 72 MPa, 4.8 +/- 0.7%, 353 +/- 23 KHN, respectively, for the test group. The differences between the groups were significant for all mechanical properties ( P <.05). For both models, the FEA revealed that maximum principal stresses were concentrated at the framework-weld junction but did not exceed the UTS of the weld joint. CONCLUSION: Within the constraints of the finite element models, mechanical failure of the welded joint between the support and the framework may not be expected under biomechanical conditions simulated in this study.

Computer Simulation↗

Acute respiratory effects of exposure to stainless steel and mild steel welding fumes.

Over the past few years, many studies, including one on our previous work, have examined the chronic effects of fumes from stainless steel (SS) welding on the health of welders. These chronic effects have been related to concentrations of chromium and nickel in SS welding fumes. The present study examined the acute respiratory effects of welding fumes in the workplace by measuring the across-shift changes in a population of 144 SS and mild steel (MS) welders and 223 controls. Manual Metal Arc, Metal Inert Gas, and Tungsten Inert Gas welding processes were studied. Pulmonary function tests were performed at the start (ante, or A) and at the end (post, or P) of the work shift. The study of sensitization to harmful respiratory effects of welding was based on the study of the (P-A)/A ratio (%) of the spirometric variations during the shift. The means of these ratios in the control subjects were used to account for the circadian effect. In SS welders we observed a significant decrease in forced vital capacity (FVC) during the shift. Significant across-shift decrements in forced expiratory volume in 1 second (FEV1) and FVC were related to the SS welding exposure compared with MS welding. Moreover, the across-shift decreases in FEV1, FVC, and peak expiratory flow (PEF) were significantly related to the Manual Metal Arc welding process, compared with Metal Inert Gas techniques (respectively, PEF = -2.7% of baseline values [SD, 11.9] vs 2.0% of baseline values [SD, 7.7] P = 0.04; FVC = -1.5% of baseline values [SD, 4.8] vs 0.2% of baseline values [SD, 4.5] P = 0.05). We also demonstrated the influence of duration of SS welding exposure on the course of lung function during the work shift. After 20 years of SS welding activity, SS welders had more significant across-shift decreases than MS welders with a similar MS exposure duration (respectively, FEV1 = -2.7% of baseline values [SD, 5.9] vs 0.7% of baseline values [SD, 4.2] P = 0.008; PEF = -3.8% of baseline values [SD, 9.6] vs 2.3% of baseline values [SD, 6.5] P = 0.04). We concluded that welding-related lung function responses are seen in SS compared with MS welders and in those with a longer lifetime welding history.

Adult↗

Bronchial reactions to exposure to welding fumes.

OBJECTIVES: To study the airway response and its mechanism to welding fumes in six welders with respiratory symptoms. METHODS: Methacholine and welding challenge tests were carried out. The concentration of welding fumes during the exposure test was measured. On two subjects who developed bronchoconstricition to welding challenge, additional tests were carried out including prick, patch, and inhalation challenges with metal salt solutions. RESULTS: Three subjects developed immediate bronchial reaction to exposure to welding fume; one to mild steel and stainless steel welding, another to mild steel and galvanised welding, and one only to galvanised welding. They all had a moderate to pronounced degree of non-specific bronchial hyperresponsiveness. The concentration of fumes during welding tests, particularly to galvanised welding, was high. An inhalation challenge test with zinc chloride salt solution in two subjects who reacted to galvanised welding was negative. Prick and patch tests with zinc chloride were also negative. CONCLUSION: The airway response to welding in these subjects is non-specific and is due to irritation rather than to sensitisation.

Adult↗

Temperature-controlled CO2 laser tissue welding of ocular tissues.

Lasers can be used for binding tissues by welding, but the clinical application of this method has been limited by the difficulties in defining and maintaining the optimal conditions. Fiberoptic radiometry allows accurate remote temperature measurements for control of laser tissue welding. We evaluated the use of a temperature-controlled tissue welding system to close corneal and corneoscleral wounds. Eighty ex vivo bovine eyes were used for the determination of welding parameters optimal for corneal wound closure. A 4 mm central corneal cut was closed with use of a CO2 laser (600 mw, 0.9 mm spot size), with tissue temperatures ranging from 45-70 degrees C and welding time ranging from 1-30 seconds. Wound strength was measured as burst pressure of the sealed wound. The welding parameters found to cause the strongest wound binding were used to weld a limbal incision of 4 mm in 10 adult albino rabbits. The fellow eye of each animal was used as a control, and the same wound was closed with one 10/0 mersilen suture. Two animals were killed immediately after the procedure, and the eyes were sent for histologic examination. Eight rabbits were followed for 1 month. Clinical examination and refraction were done 1 day, 1 week, 2 weeks, and 1 month after the procedure. Corneal topographic evaluations were done 1 week after the procedure. After 1 month the animals were killed and the eyes were examined histologically. The optimal results of wound binding by laser welding in the enucleated bovine eyes were achieved with 55-60 degrees C and at a welding time of 12-20 seconds. At these parameters the burst pressure of corneal wounds was 70 mm Hg. All laser-welded limbal wounds in the rabbits were tightly closed at the end of procedure and during the follow-up period. The refractive results after laser welding were equal to those of the controlled suture-closed wound. Laser tissue welding combined with tissue temperature monitoring can be used to close corneal wounds.

Animals↗

Flexural strength of pure Ti, Ni-Cr and Co-Cr alloys submitted to Nd:YAG laser or TIG welding.

Welding of metals and alloys is important to Dentistry for fabrication of dental prostheses. Several methods of soldering metals and alloys are currently used. The purpose of this study was to assess, using the flexural strength testing, the efficacy of two processes Nd:YAG laser and TIG (tungsten inert gas) for welding of pure Ti, Co-Cr and Ni-Cr alloys. Sixty cylindrical specimens were prepared (20 of each material), bisected and welded using different techniques. Four groups were formed (n=15). I: Nd:YAG laser welding; II- Nd:YAG laser welding using a filling material; III- TIG welding and IV (control): no welding (intact specimens). The specimens were tested in flexural strength and the results were analyzed statistically by one-way ANOVA. There was significant differences (p<0.001) among the non-welded materials, the Co-Cr alloy being the most resistant to deflection. Comparing the welding processes, significant differences (p<0.001) where found between TIG and laser welding and also between laser alone and laser plus filling material. In conclusion, TIG welding yielded higher flexural strength means than Nd:YAG laser welding for the tested Ti, Co-Cr and Ni-Cr alloys.

Analysis of Variance↗

Bladder welding in rats using controlled temperature CO2 laser system.

PURPOSE: Laser tissue welding has potential advantages over conventional suture closure of surgical wounds. It is a noncontact technique that introduces no foreign body and limits the possibility of infections and complications. The closure could be immediately watertight and the procedure may be less traumatic, faster and easier. In spite of these positives laser welding has not yet been approved for wide use. The problem in the clinical implementation of this technique arises from the difficulty in defining the conditions under which a highly reliable weld is formed. We have assumed that the successful welding of tissues depends on the ability to monitor and control the surface temperature during the procedure, thereby avoiding underheating or overheating. The purpose of this work was to develop a laser system for reliable welding of urinary tract tissues under good temperature control. MATERIALS AND METHODS: We have developed a "smart" laser system that is capable of a dual role: transmitting CO2 laser power for tissue heating, and noncontact (radiometric) temperature monitoring and control. Bladder opening (cystotomy) was performed in 38 rats. Thirty-three animals underwent laser welding. In 5 rats (control group) the bladder wound was closed with one layer of continuous 6-0 dexon sutures. Reliable welding was obtained when the surface temperature was kept at 71 + 5C. Quality of weld was controlled immediately after operation. The rats were sacrificed on days 2, 10 and 30 for histological study. RESULTS: Bladder closure using the laser welding system was successful in 31/33 (94%) animals. Histological examination revealed an excellent welding and healing of the tissue. CONCLUSIONS: Efficiency of laser welding of urinary bladder in rats was confirmed by high survival rate and quality of scar that was demonstrated by clinical and histological examinations. In the future, optimal laser welding conditions will be studied in larger animals, using CO2 lasers and other lasers, with deeper radiation penetration into tissues.

Animals↗

Tensile strength and corrosion resistance of brazed and laser-welded cobalt-chromium alloy joints.

STATEMENT OF PROBLEM: The longevity of prosthodontic restorations is often limited due to the mechanical or corrosive failure occurring at the sites where segments of a metal framework are joined together. PURPOSE: The purpose of this study was to determine which joining method offers the best properties to cobalt-chromium alloy frameworks. Brazed and 2 types of laser-welded joints were compared for their mechanical and corrosion characteristics. MATERIAL AND METHODS: Sixty-eight cylindrical cobalt-chromium dental alloy specimens, 35 mm long and 2 mm in diameter, were cast. Sixteen specimens were selected for electrochemical measurements in an artificial saliva solution and divided into 4 groups (n=4). In the intact group, the specimens were left as cast. The specimens of the remaining 3 groups were sectioned at the center, perpendicular to the long-axis, and were subsequently rejoined by brazing (brazing group) or laser welding using an X- or I-shaped joint design (X laser and I laser groups, respectively). Another 16 specimens were selected for electrochemical measurements in a more acidic artificial saliva solution. These specimens were also divided into 4 groups (n=4) as described above. Electrochemical impedance spectroscopy and potentiodynamic polarization were used to assess corrosion potentials, breakdown potentials, corrosion current densities, total impedances at lowest frequency, and polarization charge-transfer resistances. The remaining 36 specimens were used for tensile testing. They were divided into 3 groups in which specimen pairs (n=6) were joined by brazing or laser welding to form 70-mm-long cylindrical rods. The tensile strength (MPa) was measured using a universal testing machine. Differences between groups were analyzed using 1-way analysis of variance (alpha=.05). The fracture surfaces and corrosion defects were examined with a scanning electron microscope. RESULTS: The average tensile strength of brazed joints was 792 MPa and was significantly greater (P<.05) than the tensile strength of both types of laser-welded joints (404 MPa and 405 MPa). When laser welding was used, successful joining was limited to the peripheral aspects of the weld. The welding technique did not significantly affect the joint tensile strength. Electrochemical measurements indicated that the corrosion resistance of the laser-welded joints was better than of the brazed ones, primarily due to differences in passivation ability. CONCLUSION: Laser welding provides excellent corrosion resistance to cobalt-chromium alloy joints, but strength is limited due to the shallow weld penetration. Brazed joints are less resistant to corrosion but have higher tensile strength than laser welds.

Chromium Alloys↗

Sterility of plastic tubing welds in components stored at room temperature.

BACKGROUND: The ability of a sterile connecting device to maintain sterility when being used to weld tubing of a blood component to be stored at room temperature, such as a platelet unit, has not been adequately documented, nor has it been determined when the tubing to be welded is filled with liquid. STUDY DESIGN AND METHODS: The sterility of sterile connecting device welds of polyvinylchloride tubing were challenged after intentional contamination of the exterior of the tubing with both gram-positive and gram-negative organisms (4 x 10(4) to 3 x 10(6) colony-forming units/mL). Welding (n = 244) was performed with the contaminated area either being wet or having been allowed to dry. At the time of the welding, the tubing segments were either empty or filled with liquid (either aliquots of white cell-reduced apheresis platelets or bacteriologic growth medium). After the welding, the liquid was passed across the weld and held in the attached transfer pack for 5 to 7 days at room temperature. RESULTS: Two welds were found to be incomplete and leaky, and both of the units involved had positive cultures. One transfer pack had inadvertently been contaminated at the time of its initial, postweld culture by a bacterium other than the one used in the experiment. Aside from these three nonevaluable units, all of the welds were sterile when cultured after the packs were held for 5 to 7 days. CONCLUSION: This study documents the ability of the sterile connecting device to maintain a closed system in the welding of blood component units to be maintained at room temperature. All welds should be closely inspected at the time of completion to detect leaks that may lead to contamination.

Bacteria↗

Pulmonary responses to welding fumes: role of metal constituents.

It is estimated that more than 1 million workers worldwide perform some type of welding as part of their work duties. Epidemiology studies have shown that a large number of welders experience some type of respiratory illness. Respiratory effects seen in full-time welders have included bronchitis, siderosis, asthma, and a possible increase in the incidence of lung cancer. Pulmonary infections are increased in terms of severity, duration, and frequency among welders. Inhalation exposure to welding fumes may vary due to differences in the materials used and methods employed. The chemical properties of welding fumes can be quite complex. Most welding materials are alloy mixtures of metals characterized by different steels that may contain iron, manganese, chromium, and nickel. Animal studies have indicated that the presence and combination of different metal constituents is an important determinant in the potential pneumotoxic responses associated with welding fumes. Animal models have demonstrated that stainless steel (SS) welding fumes, which contain significant levels of nickel and chromium, induce more lung injury and inflammation, and are retained in the lungs longer than mild steel (MS) welding fumes, which contain mostly iron. In addition, SS fumes generated from welding processes using fluxes to protect the resulting weld contain elevated levels of soluble metals, which may affect respiratory health. Recent animal studies have indicated that the lung injury and inflammation induced by SS welding fumes that contain water-soluble metals are dependent on both the soluble and insoluble fractions of the fume. This article reviews the role that metals play in the pulmonary effects associated with welding fume exposure in workers and laboratory animals.

Air Pollutants, Occupational↗

Chemical composition and morphology of welding fume particles and grinding dusts.

Elemental composition and morphology of pure manual metal arc (MMA) welding fumes, pure grinding dust, and combined fume/dust air samples were collected and determined separately under semilaboratory conditions. The base material was stainless steel. The purpose of the present study was to create a "synthetic" work situation under semilaboratory conditions by combining one grinding period and two MMA welding periods and comparing these results with results during welding in a workshop. The duty cycles of pure welding and of pure grinding were also observed. A comparison was also made between metal inert gas (MIG) and MMA welding on stainless steel as well as a nickel-rich alloy under regular conditions. The amount of collected material was determined by weighing the membrane filters before and after exposure, and the element contents were determined by atomic spectroscopy. Other transmission electron microscopy (TEM) filters were used for TEM and computer-image analysis, in which the amount of collected material and its morphological characteristics were observed. The arcing time and the consumption of filler material were estimated for different kinds of electrodes. Chemical analysis showed that the contents of manganese and total chromium were lower in grinding dust than in welding fumes. The contents of hexavalent chromium, Cr(VI), in grinding dust were undetectable. Samples collected in welding shops where concomitant grinding was performed contained about 30% less Cr(VI) than those collected under laboratory conditions during welding only. The sizes and shapes of the particles depend on the welding process and distance of collection from the plume of the fume. To compare laboratory experiments with regular welding situations, the experiment must resemble industrial welding.(ABSTRACT TRUNCATED AT 250 WORDS)

Chromium↗

Limited thrombogenicity of low temperature, laser-welded vascular anastomoses.

BACKGROUND AND OBJECTIVE: Laser welding of vascular anastomoses has been shown to be feasible, but the clinically relevant advantages of this technique remain to be demonstrated. STUDY DESIGN/MATERIALS AND METHODS: To determine whether laser welding decreases initial anastomotic thrombogenicity, argon laser-welded aortic and venacaval anastomoses were constructed in 15 New Zealand white rabbits. Low temperature welding was done in one-half of welded anastomoses using low power ( < 0.7W) and increased irrigation with saline during welding. Anastomotic surface temperature, bursting strength, procedure time, and surface thrombogenicity (111Indium labeled platelet accumulation) were determined at 24 hours and compared to sutured anastomoses. RESULTS: Aortic and vena caval low temperature laser-welded anastomoses were significantly less thrombogenic than sutured or higher temperature laser-welded anastomoses. In addition, bursting strength of welded anastomoses exceeded physiologic requirements and vessel closure time was less with welding than with suture techniques. CONCLUSION: Low temperature laser welding limits anastomotic thrombogenicity, which may improve early patency of venous and small arterial bypass grafts.

Anastomosis, Surgical↗

Laser skin welding: in vivo tensile strength and wound healing results.

BACKGROUND AND OBJECTIVE: Laser skin welding was investigated as a general model for laser tissue closure. Scanned delivery of near-infrared laser radiation in combination with a dye can produce strong welds with limited thermal damage. STUDY DESIGN/MATERIALS AND METHODS: Two-centimeter-long, full-thickness incisions were made on the backs of guinea pigs. Wounds were closed either by laser welding or sutures and then biopsied at 0, 3, 6, 10, 14, 21, and 28 days postoperatively. Welding was achieved by using continuous-wave, 1. 06-micrometer, Nd:YAG laser radiation scanned over the incisions to produce a dwell time of approximately 80 msec. The cooling time between scans was fixed at 8 seconds. A 4-mm-diameter laser spot was maintained during the experiments, and the power was kept constant at 10 W. The operation time was fixed at 10 minutes per incision. India ink was used as an absorber of the laser radiation at the weld site, and clamps were used temporarily to appose the incision edges. RESULTS: Acute weld strengths of 2.1 +/- 0.7 kg/cm(2) were significantly higher than suture apposition strengths of 0.4 +/- 0.1 kg/cm(2) (P < 0.01), and weld strengths continued to increase over time. Lateral thermal damage in the laser welds was limited to 200 +/- 40 micrometer near the epidermal surface with less thermal damage deeper within the dermis. CONCLUSION: Our welding technique produced higher weld strengths and less thermal damage than reported in previous skin welding studies and may represent an alternative to sutures.

Animals↗

A comparison of Cunyite and Fosterite NIR tunable laser tissue welding using native collagen fluorescence imaging.

OBJECTIVE: To evaluate the technique of native collagen fluorescence imaging for assessing the extent of welded areas for tissues exposed to different near-infrared (NIR) laser wavelengths. BACKGROUND: Native fluorescence imaging may be used to identify the distribution of collagen and elastin in tissues. Our past work demonstrated that different welding strengths were obtained under the same laser power conditions using different NIR wavelengths. The role of collagen in tissue welding experiments is not well understood. METHODS: Two new NIR tunable lasers were used to weld canine skin. The welded areas on the surface and in cross sections were analyzed by measuring the spatial distribution of native collagen fluorescence at 380 nm excited by 340 nm radiation. RESULTS: The results show that native collagen fluorescence imaging is a useful technique for analyzing the extent of tissue welds produced under a range of laser exposures. Fluorescence imaging reveals the depth of laser interaction with the tissue as well as evaluating collateral damage to the tissue surface. The welded volume obtained in skin using Cunyite laser exposure at 1,430 nm is deeper than that produced with Forsterite laser exposure at 1,250 nm. The post welded tensile strength for the same power density is greater for the Cunyite lasers. Ablated tissue on the surface is more prevalent with Forsterite laser welding at 1,250 nm than with Cunyite at 1,430 nm. CONCLUSION: Native collagen fluorescence can distinguish between tissue welds that have been produced by different NIR wavelengths. Tissue welding using 1,430 nm radiation is more effective than that using 1,250 nm.

Animals↗

Laser welding of cast titanium and dental alloys using argon shielding.

PURPOSE: This study investigated the effect of argon gas shielding on the strengths of laser-welded cast Ti and Ti-6Al-7Nb and compared the results to those of two dental casting alloys. MATERIALS AND METHODS: Cast plates of Ti, Ti-6Al-7Nb, gold, and Co-Cr alloy were prepared. After polishing the surfaces to be welded, two plates were abutted and welded using Nd:YAG laser at a pulse duration of 10 ms, spot diameter of 1 mm, and voltage of 200 V. Five specimens were prepared for each metal by bilaterally welding them with three or five spots either with or without argon shielding. The failure load and percent elongation were measured at a crosshead speed of 1.0 mm/min. RESULTS: The factor of argon shielding significantly affected the failure load and elongation of the laser-welded specimens. The failure loads of argon-shielded laser-welded CP Ti and Ti-6Al-7Nb were greater compared with the failure loads of specimens welded without argon shielding for both three- and five-spot welding. Regardless of argon shielding, the failure loads of the laser-welded gold alloy were approximately half that of the control specimens. In contrast, the failure loads of the nonshielded laser-welded Co-Cr alloy were greater. The percent elongations positively correlated with the failure loads. CONCLUSIONS: The use of argon shielding is necessary for effective laser-welding of CP Ti and Ti-6Al-7Nb but not for gold and Co-Cr alloy.

Analysis of Variance↗