PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “data fragmentation”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

Collision-induced dissociation of cytidine and its derivatives.

The collision-induced dissociation of adenosine, uridine and guanosine, and their corresponding nucleobases has been published previously.1-3 Here we report the collision-induced dissociation of cytidine and the elucidation of its fragmentation pathways using stable isotope-labeled cytidines, through a quadrupole ion trap for tandem mass spectrometry up to MS(4). Furthermore, we investigated the collision-induced dissociation of five cytidine derivatives: 3-methylcytidine, N(4)-methyl-2'-deoxycytidine, 5-methylcytidine, 2-thiocytidine and N(4)-acetylcytidine. The primary fragmentation pathway was the neutral loss of ribose. MS(3) on the retained nucleobase generally resulted in an intense signal from the elimination of ammonia, but also in fragment ions characteristic of the different cytosine derivatives. On the basis of the MS(n) data, fragmentation pathways and plausible mechanisms are suggested.

Cytidine↗

Inverse 15N-metabolic labeling/mass spectrometry for comparative proteomics and rapid identification of protein markers/targets.

The inverse labeling/mass spectrometry strategy has been applied to protein metabolic (15)N labeling for gel-free proteomics to achieve the rapid identification of protein markers/targets. Inverse labeling involves culturing both the perturbed (by disease or by a drug treatment) and control samples each in two separate pools of normal and (15)N-enriched culture media such that four pools are produced as opposed to two in a conventional labeling approach. The inverse labeling is then achieved by combining the normal (14)N-control with the (15)N-perturbed sample, and the (15)N-control with the (14)N-perturbed sample. Both mixtures are then proteolyzed and analyzed by mass spectrometry (coupled with on-line or off-line separation). Inverse labeling overcomes difficulties associated with protein metabolic labeling with regard to isotopic peak correlation and data interpretation in the single-experiment approach (due to the non-predictable/variable mass difference). When two data sets from inverse labeling are compared, proteins of differential expression are readily recognized by a characteristic inverse labeling pattern or apparent qualitative mass shifts between the two inverse labeling analyses. MS/MS fragmentation data provide further confirmation and are subsequently used to search protein databases for protein identification. The methodology has been applied successfully to two model systems in this study. Utilizing the inverse labeling strategy, one can use any mass spectrometer of standard unit resolution, and acquire only the minimum, essential data to achieve the rapid and unambiguous identification of differentially expressed protein markers/targets. The strategy permits quick focus on the signals of differentially expressed proteins. It eliminates the detection ambiguities caused by the dynamic range of detection. Finally, inverse labeling enables the detection of covalent changes of proteins responding to a perturbation that one might fail to distinguish with a conventional labeling experiment.

Amino Acid Sequence↗

Rapid analysis of controlled substances using desorption electrospray ionization mass spectrometry.

The recently developed technique of desorption electrospray ionization (DESI) has been applied to the rapid analysis of controlled substances. Experiments have been performed using a commercial ThermoFinnigan LCQ Advantage MAX ion-trap mass spectrometer with limited modifications. Results from the ambient sampling of licit and illicit tablets demonstrate the ability of the DESI technique to detect the main active ingredient(s) or controlled substance(s), even in the presence of other higher-concentration components. Full-scan mass spectrometry data provide preliminary identification by molecular weight determination, while rapid analysis using the tandem mass spectrometry (MS/MS) mode provides fragmentation data which, when compared to the laboratory-generated ESI-MS/MS spectral library, provide structural information and final identification of the active ingredient(s). The consecutive analysis of tablets containing different active components indicates there is no cross-contamination or interference from tablet to tablet, demonstrating the reliability of the DESI technique for rapid sampling (one tablet/min or better). Active ingredients have been detected for tablets in which the active component represents less than 1% of the total tablet weight, demonstrating the sensitivity of the technique. The real-time sampling of cannabis plant material is also presented.

Acetaminophen↗

Identification of fur, aconitase, and other proteins expressed by Mycobacterium tuberculosis under conditions of low and high concentrations of iron by combined two-dimensional gel electrophoresis and mass spectrometry.

Iron plays a critical role in the pathophysiology of Mycobacterium tuberculosis. To gain a better understanding of iron regulation by this organism, we have used two-dimensional (2-D) gel electrophoresis, mass spectrometry, and database searching to study protein expression in M. tuberculosis under conditions of high and low iron concentration. Proteins in cellular extracts from M. tuberculosis Erdman strain grown under low-iron (1 microM) and high-iron (70 microM) conditions were separated by 2-D polyacrylamide gel electrophoresis, which allowed high-resolution separation of several hundred proteins, as visualized by Coomassie staining. The expression of at least 15 proteins was induced, and the expression of at least 12 proteins was decreased under low-iron conditions. In-gel trypsin digestion was performed on these differentially expressed proteins, and the digestion mixtures were analyzed by matrix-assisted laser desorption ionization time-of-flight mass spectrometry to determine the molecular masses of the resulting tryptic peptides. Partial sequence data on some of the peptides were obtained by using after source decay and/or collision-induced dissociation. The fragmentation data were used to search computerized peptide mass and protein sequence databases for known proteins. Ten iron-regulated proteins were identified, including Fur and aconitase proteins, both of which are known to be regulated by iron in other bacterial systems. Our study shows that, where large protein sequence databases are available from genomic studies, the combined use of 2-D gel electrophoresis, mass spectrometry, and database searching to analyze proteins expressed under defined environmental conditions is a powerful tool for identifying expressed proteins and their physiologic relevance.

Aconitate Hydratase↗

Reproduction, foraging and the negative density-area relationship of a generalist rodent.

While many species show positive relationships between population density and habitat patch area, some species consistently show higher densities in smaller patches. Few studies have examined mechanisms that may cause species to have negative density-area relationships. We tested the hypothesis that greater reproduction in edge versus interior habitats and small versus large fragments contributes to higher densities of white-footed mice (Peromyscus leucopus) in small versus large forest fragments. We also examined vegetation structure and foraging tray utilization to evaluate if greater reproduction was a result of higher food availability. There were greater number of litters and proportion of females producing litters in the edge versus interior of forest fragments, which may have contributed to greater population growth rates and higher densities in edge versus interior and small versus large fragments. Data on vegetation structure and giving-up densities of seeds in artificial patches suggest that food availability may be higher in edge versus interior habitats and small versus large fragments. These results, in an area with few or no long-tailed weasels, provide a distinct contrast to the findings of Morris and Davidson (Ecology 81:2061, 2000) who observed lower reproduction in forest edge habitat as a result of high weasel predation, suggesting that specialist predators may be important in affecting the quality of edge habitat. While we cannot exclude the potential contributions of immigration, emigration, and mortality, our data suggest that greater reproduction in edge versus interior habitat is an important factor contributing to higher densities of P. leucopus in small fragments.

Analysis of Variance↗

Structure analysis of acetylated and non-acetylated O-linked MUC1-glycopeptides by post-source decay matrix-assisted laser desorption/ionization mass spectrometry.

We have investigated the potential of structural elucidation of O-linked glycopeptides by post-source decay matrix-assisted laser desorption ionization mass spectrometry (PSD-MALDI-MS). In order to establish detailed fragmentation patterns and to dissect fragment ions with and without carbohydrate content, the same O-linked MUC1-derived glycopeptides with acetylated and non-acetylated sugars were analysed and compared. Furthermore, we were interested to examine possible differences in the fragmentation between glycopeptides with acetylated and non-acetylated sugars. The obtained PSD-MALDI-MS spectra showed a rather complete set of fragmentation data which allows to localize the glycan on the peptide, in parallel with sequencing a short glycan and the backbone peptide. Fragmentations of the sugars were dominated by inter-ring cleavages at the glycosidic bond. Intra-ring cleavage did also occur from the non-reducing end, but to a much lower extent. The fragmentation of the peptide backbone was not changed either by acetylated or non-acetylated sugars. Glycosylated peptide fragments occurred as fully glycosylated fragment ions, partially deglycosylated ions and completely deglycosylated ions, and was not influenced by the acetylation of sugars. However, differences occurred in the quality and quantity of fragment ions from the non-reducing end of the glycan part when comparing acetylated with non-acetylated glycopeptides.

Acetylation↗

A model for the misfolded bis-His intermediate of cytochrome c: the 1-56 N-fragment.

We have characterized the ferric and ferrous forms of the heme-containing (1-56 residues) N-fragment of horse heart cytochrome c (cyt c) at different pH values and low ionic strength by UV-visible absorption and resonance Raman (RR) scattering. The results are compared with native cyt c in the same experimental conditions as this may provide a deeper insight into the cyt c unfolding-folding process. Folding of cyt c leads to a state having the heme iron coordinated to a histidine (His18) and a methionine (Met80) as axial ligands. At neutral pH the N-fragment (which lacks Met80) shows absorption and RR spectra that are consistent with the presence of a bis-His low spin heme, like several non-native forms of the parental protein. In particular, the optical spectra are identical to those of cyt c in the presence of a high concentration of denaturants; this renders the N-fragment a suitable model to study the heme pocket microenvironment of the misfolded (His-His) intermediate formed during folding of cyt c. Acid pH affects the ligation state in both cyt c and the N-fragment. Data obtained as a function of pH allow a correlation between the structural properties in the heme pocket of the N-fragment and those of non-native forms of cyt c. The results underline that the (57-104 residues) segment under native-like conditions imparts structural stability to the protein by impeding solvent access into the heme pocket.

Animals↗

Mechanism of inactivation of beta-lactamases by novel 6-methylidene penems elucidated using electrospray ionization mass spectrometry.

The reactions of 6-methylidene penems 4-7 with beta-lactamases (TEM-1, SHV-1, Amp-C) were characterized by electrospray ionization mass spectrometry (ESI-MS). The kinetics of the reactions were monitored, demonstrating that only one penem molecule reacts to form an acyl-enzyme complex. For penem 5, the ESI-MS/MS spectrum of the hydrolysis product produced in the reaction was identical to the spectrum generated from a synthesized dihydro[1,4]thiazepine 10, confirming the rearrangement of the penem ring system to a seven-membered dihydro[1,4]thiazepine structure. Gas-phase ESI-MS/MS fragmentation data were rationalized due to tautomerization between imine and enamine substructures. ESI-MS/MS analysis of the T-6 trypsin-digested fragments of TEM-1 and SHV-1 demonstrated that the penems were only attached to Ser-70 of these class A beta-lactamases and that the penem ring structures were rearranged to seven-membered dihydro[1,4]thiazepines.

Bacterial Proteins↗

An improved protocol for the production of AFLP markers in complex genomes by means of capillary electrophoresis.

The amplified fragment-length polymorphism (AFLP) technology is a recently introduced method to investigate genomes of different complexity, from microbial to higher organisms. It is applied to purposes as diverse as identification of species, strain and varieties, investigation of genetic diversity within and between populations, simple and complex trait mapping, and construction of linkage and physical maps. This technology has been designed on the use of primers labelled with radioactivity and on AFLP fragment separation on sequencing gel. We show that the original EcoRI/TaqI AFLP protocol does not perform appropriately when transferred to fluorescent labelling and capillary electrophoresis (CE), and propose an improved protocol for the production of high-quality AFLP markers in fish, rodents and artiodactyles by means of the Beckman-Coulter CEQ2000 automatic DNA sequencer. In addition, we describe the procedure routinely used in our laboratory to obtain binary matrices from AFLP profiles with the aid of Genographer free-share software (vers. 1.6.0, J.J. Benham, Montana State University), able to elaborate original fragment data and convert them to standard graphical formats for phylogenetic analyses. Comparison with radioactive AFLPs in goats confirmed the reliability of the protocol developed for CE. In fact, 107 fragments generated by two primer combinations and identified by both techniques were attributed the same scoring. Compared with traditional methods, the use of capillary systems and automated analysis increases data throughput and scoring reliability, decreasing the overall experimental error.

Animals↗

A contig assembly program based on sensitive detection of fragment overlaps.

An effective computer program for assembling DNA fragments, the contig assembly program (CAP), has been developed. In the CAP program, a filter is used to eliminate quickly fragment pairs that could not possibly overlap, a dynamic programming algorithm is applied to compute the maximal-scoring overlapping alignment between each remaining pair of fragments, and a simple greedy approach is employed to assemble fragments in order of alignment scores. To identify the true fragment overlaps, the dynamic programming algorithm uses specially chosen sets of alignment parameters to tolerate sequencing errors and to penalize "mutational" changes between different copies of a repetitive sequence. The performance tests of the program on fragment data from genomic sequencing projects produced satisfactory results. The CAP program is efficient in computer time and memory; it took about 4 h to assemble a set of 1015 fragments into long contigs on a Sun workstation.

Algorithms↗

Pressure-release versus rigid reflector for extracorporeal shockwave lithotripsy.

PURPOSE: To evaluate the advantages and disadvantages of using a pressure-release reflector instead of a rigid reflector to concentrate shockwaves for extracorporeal shockwave lithotripsy (SWL). MATERIALS AND METHODS: As in all electrohydraulic lithotripters, shockwaves were generated by electrical breakdown of water between two electrodes, located at the focus (F1) closest to a paraellipsoidal reflector. A pressure-release reflector, made out of polyurethane foam, was constructed and tested on a research lithotripter using kidney stone models. Fragmentation data and pressure measurements were compared with those of a conventional rigid reflector tested on the same device. RESULTS: The weight of stone model fragments remaining after shockwave exposure was less with the pressure-release reflector after screening through a 3.0 x 3.0-mm mesh. The residual fragment weight was less with the rigid reflector using 1.0 x 1.0- and 0.6 x 0.6-mm meshes. CONCLUSION: Pressure-release reflectors may maintain acceptable stone fragmentation while offering improved patient safety and should be considered for SWL.

Equipment Design↗

Top-down characterization of nucleic acids modified by structural probes using high-resolution tandem mass spectrometry and automated data interpretation.

A top-down approach based on sustained off-resonance irradiation collision-induced dissociation (SORI-CID) has been implemented on an electrospray ionization (ESI) Fourier transform mass spectrometer (FTMS) to characterize nucleic acid substrates modified by structural probes. Solvent accessibility reagents, such as dimethyl sulfate (DMS), 1-cyclohexyl-3-(2-morpholinoethyl)carbodiimide metho-p-toluenesulfonate (CMCT), and beta-ethoxy-alpha-ketobutyraldehyde (kethoxal, KT) are widely employed to reveal the position of single- vs double-stranded regions and obtain the footprint of bound proteins onto nucleic acids structures. Established methods require end-labeling of the nucleic acid constructs, probe-specific chemistry to produce strand cleavage at the modified nucleotides, and analysis by polyacrylamide gel electrophoresis to determine the position of the susceptible sites. However, these labor-intensive procedures can be avoided when mass spectrometry is used to identify the probe-induced modifications from their characteristic mass signatures. In particular, ESI-FTMS can be directly employed to monitor the conditions of probe application to avoid excessive alkylation, which could induce unwanted distortion or defolding of the substrate of interest. The sequence position of the covalent modifications can be subsequently obtained from classic tandem techniques, which allow for the analysis of individual target adducts present in complex reaction mixtures with no need for separation techniques. Selection and activation by SORI-CID has been employed to reveal the position of adducts in nucleic acid substrates in excess of 6 kDa. The stability of the different covalent modifications under SORI-CID conditions was investigated. Multiple stages of isolation and activation were employed in MS(n)() experiments to obtain the desired sequence information whenever the adduct stability was not particularly favorable, and SORI-CID induced the facile loss of the modified base. A new program called MS2Links was developed for the automated reduction and interpretation of fragmentation data obtained from modified nucleic acids. Based on an algorithm that searches for plausible isotopic patterns, the data reduction module is capable of discriminating legitimate signals from noise spikes of comparable intensity. The fragment identification module calculates the monoisotopic mass of ion products expected from a certain sequence and user-defined covalent modifications, which are finally matched with the signals selected by the data reduction program. Considering that MS2Links can generate similar fragment libraries for peptides and their covalent conjugates with other peptides or nucleic acids, this program provides an integrated platform for the structural investigation of protein-nucleic acid complexes based on cross-linking strategies and top-down ESI-FTMS.

Aldehydes↗

Physical analysis of the terminal 270 kb of DNA from human chromosome 1q.

DNA from three 1q44-derived human telomeric yeast artificial chromosome clones was analyzed using physical mapping methods. The smallest clone, yRM2004 (65 kb), corresponded exactly to the distal end of the largest clone, yRM2123 (270 kb). The third clone, yRM2192, overlapped with the proximal end of yRM2123 but not the distal end, suggesting that it is most likely a deletion artifact of a clone originally derived from a 1q telomere fragment. Data from fluorescence in situ hybridization analysis, restriction mapping, and RecA-assisted restriction enzyme cleavage experiments indicate that the molecular clone yRM2123 contains a 260-kb DNA fragment colinear with a genomic telomere-terminal fragment from 1q. yRM2123 contains low-copy subtelomeric and subterminal repeats at its distal end, single-copy DNA more centromerically, and a CG-rich region with homology to mouse DNA. Markers derived from this clone will allow telomeric closure of the physical and genetic linkage maps of human chromosome 1q.

Animals↗

Analysis of isomeric mixtures using blackbody infrared radiative dissociation: determining isomeric purity and obtaining individual tandem mass spectra simultaneously.

A new method that makes possible, for the first time, simultaneous acquisition of individual dissociation mass spectra of isomeric ions in mixtures is presented. This method exploits the exquisite sensitivity of blackbody infrared radiative dissociation kinetics to minor differences in ion structure. Instead of separating precursor ions based on mass (isomers have identical mass), fragment ions are related to their original precursor ions on the basis of rate constants for dissociation. Mixtures of the peptide isomers des-R1 and des-R9 bradykinin are dissociated simultaneously at several temperatures. By fitting the kinetic data to double-exponential functions, the dissociation rate constant and abundance of each isomer in the mixture are obtained. To overcome the difficulty of fitting double-exponential functions, a novel global analysis method is used in which several dissociation data sets collected at different temperatures are simultaneously fit. The kinetic data measured at multiple temperatures are modeled with the preexponentials (corresponding to the abundance of each isomer) as "global" parameters which are constant for all data sets and the exponentials (rate constants) as "local" variables which differ for each data set. The use of global parameters significantly improves the accuracy with which abundances and dissociation rate constants of each individual compound can be obtained from the mixture data. Fragment ions produced from a mixture of these two isomers are related back to their respective precursor ions from the kinetic data. Thus, not only can the composition of the isomeric mixture be determined but an individual tandem mass spectrum of each component in the mixture can be obtained.

Bradykinin↗

Applicability of Iceland spar as a stone model standard for lithotripsy devices.

The identification of a universal stone model standard would enable reproducible fragmentation data useful for the design, evaluation, and comparison of various lithotripsy devices. The clinical benefits of such a stone model include the elucidation of setting parameters that would optimize fragmentation strategies. Iceland spar is a pure form of calcite (CaCO3) that was subjected to experimental disintegration by electrohydraulic lithotripsy and extracorporeal shockwave lithotripsy. Iceland spar was fragmented with both lithotripsy methods in a reproducible fashion. The degree of fragmentation was directly related to alterations in either power or shock frequency. Iceland spar is radiopaque, inexpensive, easily obtained, homogenous in composition, and sizable. Iceland spar meets a variety of stone model criteria, warranting its continued investigation as a potential stone model standard.

Calcium Carbonate↗

The registration function as a critical dependency in a lifetime clinical record (LCR).

Over the past two years, we have successfully migrated the Regenstrief Clinical Information System into our hospital. Integral to this process was the need to develop interfaces and processes supporting movements of patient identification data between the existing clinical management system (Unity, SMS) and Carebase (RCIS). Critical to the implementation of Carebase was the development of an interface between Carebase and the registration system based upon a unique medical record number. Even more critical was the development of stable processes that supported the accurate patient identification and assignment of medical record numbers. The medical record number at our institution is assigned or verified at the time of registration. Major problems occurred when patients presented during system down-times and existing medical record numbers could not be accessed, resulting in multiple registrations and medical record numbers for the same patient. This resulted in data fragmentation and required merging at a later date. Other more serious problems resulted from the assignment of the same medical record number to separate patients and with the mixing of data from multiple patients into one patient record. This was largely due to the failure of clerical personnel to appropriately identify patients at the time of registration, or multiple patients sharing identification documents, a common problem in our geographic area. Given that clinical data was to be maintained and added to the repository for several decades, errors such as these in registration would prove catastrophic. The interfaces between the various clinical systems that pass data to Carebase are all HL-standard and largely prevent data passage if registration data is inaccurate. During the early stages of implementation, approximately 300 exceptions per day were generated from clinical systems attempting to pass data to the repository. Following re¿engineering of the registration process, education of clerical personnel, and analysis of exception type, the number of exceptions due to faulty registration data fell to less than one per week. To achieve improvement in exception volume, several innovative measures were undertaken. Firstly, down-time procedures were changed to require query of the LCR for existing registration data. The LCR was maintained on a separate platform that experienced essentially no down-time and was available for this purpose. This largely eliminated the need for the use of "down-time numbers" or medical record numbers that could be temporarily assigned to patients registered when the registration system was unavailable (data would subsequently be merged into existing patient records if the patient was found to be currently in the system). If the patient was not in the LCR, then a permanent number was assigned in sequence. A registration dataset was developed and encoded onto a magnetic card (Carecard, Eltrax) and carried by patients. This enabled the rapid verification of registration data on subsequent visits to the parent institution or affiliated clinical sites. The issue of fraudulent use of the card and encoded registration dataset, however, remained problematic. Currently, a new imaging system is being installed that will soon enable the inclusion of a photograph of the patient as a component of the registration dataset. Perhaps the most significant change in the registration process involved the education of central registration and admitting personnel. An educational program was developed that reinforced the need for accuracy in collecting registration data, identifying patients, and assigning medical record numbers; more importantly, it stressed the linkage of the registration function and patient care. Lastly, an aggressive approach to monitoring exceptions resulting from errors in registration was developed. A near real-time process for identifying errors in registrations allowed for rapid intervention and feedback to involved de

Medical Records Systems, Computerized↗

Characterization of protein kinase A phosphorylation: multi-technique approach to phosphate mapping.

A multi-technique approach to identification and mapping of phosphorylation on protein kinase A (PKA) is described. X-ray crystallography revealed phosphorylation at T197 and S338 while mass spectrometry (MS) on the intact protein suggested phosphorylation at three sites. Tryptic digestion, followed by MS, confirmed the presence of three phosphates. However, metal affinity treatment of the digest prior to MS revealed the presence of a fourth phosphopeptide. Subsequent analysis of the digests using liquid chromatography (LC) coupled with quadrupole ion trap (QIT) MS confirmed phosphorylation at S10 and S338 and suggested phosphorylation at S139 and T195/197. Unfortunately, identification of pS139 was inconclusive due to low signal intensity and early elution in reversed-phase LC while poor MS/MS data prevented localization of the phosphate to T195 or T197. Phosphopeptide modification with ethanethiol, followed by LC QIT-MS/MS, identified four phosphopeptides in a single experiment. In addition, the fragmentation data provided significantly more sequence information than data obtained from unmodified peptides. Data from this study suggested that PKA was completely phosphorylated at S10, T197, and S338 and partially phosphorylated at S139. These results illustrate that critical information can be lost unless multiple MS techniques are used for identification and validation of phosphorylation.

Animals↗

Negative ion graphitised carbon nano-liquid chromatography/mass spectrometry increases sensitivity for glycoprotein oligosaccharide analysis.

Negative ion nano-liquid chromatography/mass spectrometry (nano-LC/MS) and tandem mass spectrometry (nano-LC/MS(2)), using graphitised carbon as separating medium, were explored for analysing neutral and acidic O-linked and N-linked oligosaccharide alditols. Compared to the sensitivity of capillary LC/MS (flow rate of 6 microL/min) coupled with a conventional electrospray ionisation source, the nano-LC/MS (flow rate of 0.6 microL/min) with a nanoflow ion source was shown to increase the sensitivity ten-fold with a detection limit in the low-femtomole range. The absolute signals for the [M-nH](n-) ions of the oligosaccharides were increased 100-fold, enabling accumulation of high-quality fragmentation data in MS(2) mode, in which detection of low abundant sequence ions is necessary for characterisation of highly sialylated N-linked oligosaccharides. Oligosaccharides with high numbers of sialic acid residues gave dominant fragments arising from the loss of sialic acid, and less abundant fragments from cleavage of other glycosidic bonds. Enzymatic off-line desialylation of oligosaccharides in the low-femtomole range prior to MS(2) analysis was shown to increase the quality of the spectra. Automated glycofragment mass fingerprinting using the GlycosidIQ software confirmed the oligosaccharide sequence for both neutral desialylated as well as sialylated structures. Furthermore, the use of graphitised carbon nano-LC/MS enabled the detection of four sialylated O-linked oligosaccharides on membrane proteins from ovarian tissue (5 microg of total amount of protein).

Anions↗