PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “needle”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

Usability of a microtapered needle (TN3305) for insulin treatment in japanese patients with diabetes mellitus: a comparative clinical study with a standard thin wall needle.

BACKGROUND: We evaluated the clinical usability of a microtapered needle (TN3305, "Needle T," Terumo Corp., Tokyo, Japan) by comparing it with a standard needle (Micro-Fine +, 31 gauge, 5 mm, thin wall, "Needle B," Nippon Becton Dickinson Co., Ltd., Tokyo) in a multicenter study. METHODS: Ninety-nine patients with diabetes mellitus being treated in 11 Japanese hospitals were enrolled in the study. Written consent was obtained from all patients. They were allocated randomly to two groups by an envelope (crossover) method. Injections were performed using one needle first, followed by the other needle 4 or 5 days later. Pain caused by injection was evaluated using a visual analogue scale (VAS). RESULTS: In the overall evaluation, Needle T was chosen by 40 patients (44.4%) and Needle B by 17 (18.8%); 33 patients (36.7%) expressed no preference. VAS scores for Needles T and B were 1.48 +/- 0.18 and 2.47 +/- 0.24 cm, respectively (P < 0.001). In this study, lower VAS indicated less pain. CONCLUSIONS: The preferences and VAS scores suggested that Needle T caused less pain than Needle B. The incidence of adverse events and safety were equivalent for both needles. We believe that usability of Needle T by patients for self-injection is better.

Adult↗

Effects of elevated carbon dioxide concentration and temperature on needle growth, respiration and carbohydrate status in field-grown Scots pines during the needle expansion period.

We determined effects of long-term elevation of carbon dioxide concentration ([CO2]) and temperature on growth, respiration and carbohydrate concentration in needles of field-grown Scots pine (Pinus sylvestris L.) trees during the needle expansion period. Sixteen 20-year-old Scots pine trees were individually enclosed in closed-top, environmentally controlled chambers for 4 years in one of four environments: ambient conditions (CON); elevated [CO2] (EC); elevated temperature (ET); and a combination of both (EC + ET). Needle growth, carbohydrate concentration and dark respiration were measured at 3-day intervals throughout the needle expansion period. Dark respiration was partitioned into growth and maintenance components by regressing specific respiration rate against specific growth rate. In all treatments, growth, carbohydrate concentration and daily dark respiration rates of needles followed a similar seasonal pattern throughout the needle expansion period. Treatments EC, ET and EC + ET increased individual needle area and dry weight compared with the CON treatment. Carbohydrate concentrations in needles were increased by EC, but reduced by ET and EC + ET. Daily respiration rates increased slightly in the early stage of needle expansion and decreased gradually in the late stage when needles were exposed to EC, but increased consistently throughout the growing period when needles were exposed to ET or EC + ET. Partitioning of respiration into its two functional components showed that the growth respiration coefficient was unaffected by the treatments, whereas maintenance respiration was reduced by EC but increased by ET and EC + ET. Maintenance respiration was more sensitive to elevated temperature than growth respiration. We conclude that the difference in respiration rates between expanding and expanded needles should be taken into account when estimating the respiratory responses of needles to elevated [CO2] and temperature.

Carbohydrates↗

Comparison between the 21-gauge Urocut needle and the 21-gauge Surecut needle in echo-guided percutaneous biopsy of neoplastic liver lesions.

Fine cutting needles for histology are now widely used in echo-guided biopsies of various organs. In this study we compared the results obtained in the biopsy of neoplastic hepatic lesions using two different 21-gauge cutting needles: Trucut needle (Urocut) and a modified Menghini needle (Surecut). Eighty-five patients with primary or metastatic hepatic neoplasms were biopsied with a Urocut needle and a further 85 patients underwent biopsy with a Surecut needle. The two groups were comparable for size and nature of hepatic neoplasms. The Urocut needle provided a much higher percentage of diagnostic material than the Surecut needle (94.8% vs 70.5%) regardless of the primary or metastatic nature of the lesion or its size. The diagnostic accuracy was only identical for both needles (91.3% for Urocut vs 91.5% for Surecut) whenever the diagnostic material was compared in cases in which both types of needles had been used to take the biopsy specimens. There were no complications in either of the two groups studied. Given the smaller incidence of non-diagnostic biopsies with the Urocut needle, we consider that this needle should be preferred in echo-guided biopsies of neoplastic hepatic lesions.

Adult↗

Transjugular liver biopsy: modified Ross transseptal needle versus quick-core biopsy needle.

BACKGROUND: We evaluated the differences in sample adequacy and safety between a transseptal needle and Quick-core biopsy needle for transjugular liver biopsy. METHODS: Eighteen consecutive patients who had a bleeding diatheses and/or ascites underwent transjugular liver biopsy using a transseptal needle (11 patients) and Quick-core biopsy needle (seven patients). The length of the specimens was measured before fixation. A pathologist reviewed histologic slides for sample adequacy and pathologic diagnoses. Clinical records were reviewed for complication. RESULTS: In all patients, liver biopsy was successful. A total of 45 specimens were obtained, with an average of 2.5 passes per patient. The length of specimen was significantly longer with the Quick-core biopsy needle than with the transseptal needle (p<0.05). Biopsied tissue was fragmented in 17 of 25 specimens with the transseptal needle but not fragmented in any specimen with the Quick-core biopsy needle. All specimens were determined to be adequate except one with the transseptal needle. There was no early or delayed complication in any patient. CONCLUSION: Transjugular liver biopsy is a safe and effective procedure without any significant difference in complication and adequacy when using a transseptal needle or Quick-core biopsy needle. Larger specimens can be obtained without tissue fragmentation with the Quick-core biopsy needle.

Adolescent↗

Effect of needle tract bleeding on occurrence of pneumothorax after transthoracic needle biopsy.

PURPOSE: Occasionally bleeding along the needle trajectory is observed at post-biopsy computed tomographic sections. This study was designed to evaluate the possible effect of needle tract bleeding on the occurrence of pneumothorax and on requirement of chest tube insertion. MATERIALS AND METHODS: Two hundred eighty-four needle biopsies performed in 275 patients in whom the needle traversed the aerated lung parenchyma were retrospectively reviewed. Bleeding along the needle tract, occurrence of pneumothorax and need for chest tube insertion, type and size of the needle, size of the lesion, length of the lung traversed by the needle, presence or absence of emphysema were noted. Effect of these factors on the rate of pneumothorax and needle-tract bleeding was evaluated. The data were analyzed by chi2 test. RESULTS: Pneumothorax developed in 100 (35%) out of 284 procedures requiring chest tube placement in 16 (16%). Variables that were significantly associated with an increased risk of pneumothorax were depth of the lesion (P < 0.001) and severity of emphysema (P < 0.05). There was bleeding along the needle tract in 18.6% (n = 53) of the procedures. Pneumothorax occurred in 18 (33.9%) out of 53 procedures in which tract-bleeding was observed and in 82 (35.4%) out of 231 procedures in which tract-bleeding was not seen. The difference between the two groups was not significant (P > 0.05). However, analysis of the relation between length of lung traversed by the needle, tract-bleeding and pneumothorax rate indicated that tract-bleeding had a preventive effect on development of pneumothorax (P < 0.001). Occurrence of tract bleeding also had preventive effect on pneumothorax in the presence of emphysema (P < 0.05). The only variable which had effect on occurrence of tract-bleeding was the length of the lung traversed by needle (p < 0.001). Requirement for chest tube insertion was smaller in the tract-bleeding group than non-tract bleeding group, 11% (2/18) to 17% (14/82), respectively. But this difference was not significant statistically (P > 0.05). CONCLUSION: Bleeding in the needle tract has a preventive effect on the occurrence of the pneumothorax in deep-seated lesions and in the presence of emphysema, although it does not affect the overall rate of pneumothorax.

Adult↗

Endoscopic ultrasound-guided fine-needle aspiration in focal pancreatic lesions: a prospective intraindividual comparison of two needle assemblies.

BACKGROUND AND STUDY AIMS: The results of endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) in focal pancreatic lesions are less impressive than those in the mediastinum. The aim of this prospectively randomized study was to compare two commercially available needle assemblies with regard to handling and cytopathological yield. PATIENTS AND METHODS: A total of 30 patients (19 men, 11 women; mean age 61) with focal pancreatic lesions underwent EUS-FNA with each of the two needles (GIP, Wilson-Cook). The sequence was randomized for the examiner and blinded for the cytologist. Three patients had to be excluded because of the impossibility of sample assignment or patient follow-up. EUS-FNA was performed using the standard technique with linear echo endoscopes. RESULTS: None of the characteristics evaluated by the examiner differed significantly between either of the needles. Inadequate results were obtained in 11% using the GIP needle, but in none with the Wilson-Cook needle. GIP needle cytology revealed malignancy in 11 patients (sensitivity, specificity, and accuracy were 55%, 100%, and 65%, respectively, including inadequate results). The aspirates obtained with the Wilson-Cook needle identified malignancy in 16 patients (sensitivity, specificity, and accuracy were 85%, 100%, and 89%, respectively). CONCLUSIONS: No statistically significant differences were detected in the handling of either of the two needle assemblies. No complications were reported using the GIP needles. However, in four procedures breakages of the outer Teflon sheath of the Wilson-Cook needle occurred, and in another four cases re-insertion of the stylet was impossible. Nevertheless, cytopathologic results were significantly better with the Wilson-Cook needle.

Adult↗

CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate.

PURPOSE: To evaluate the effect of coaxial needle size on pneumothorax rate and the diagnostic accuracy of computed tomography (CT)-guided transthoracic needle aspiration biopsy (TNAB) of pulmonary nodules. MATERIALS AND METHODS: Retrospective review of 846 consecutive CT-guided TNAB procedures was performed. A coaxial approach was implemented in all patients by using an 18- or 19-gauge outer stabilizing needle through which a smaller aspiration needle or automated biopsy gun was inserted for tissue sampling. Univariate and multivariate regression analyses were used to analyze coaxial needle size, age, sex, smoking history, lesion size, use of an automated core biopsy gun, number of needle passes, and frequency of chest tube placement. Sensitivity, specificity, and diagnostic accuracy were calculated for 676 patients with at least 18 months of clinical follow-up. RESULTS: Pneumothorax occurred in 226 of 846 patients. Coaxial needle size and patient age had a significant effect on pneumothorax rate. Pneumothorax occurred in 124 (38%) of 324 patients who underwent procedures with 18-gauge needles and in 121 (23%) of 522 patients who underwent procedures with 19-gauge needles (P <.001). The overall diagnostic accuracy was 96% for procedures performed with 18-gauge needles and 92% for procedures performed with 19-gauge needles, with a sensitivity of 95% and 89% and a specificity of 100% and 99%, respectively. Pneumothorax occurred in 153 patients older than 60 years, in 99 patients 60 years and younger (P <.02), in 90 patients older than 70 years, and in 162 patients younger than 70 years (P <.01). The relationship between pneumothorax rate and age as a continuous distribution was not significant (P <.07), nor were the 50- or 75-year age cutoffs (P <.06 and P <.9, respectively). CONCLUSION: Use of a smaller coaxial stabilizing needle produces a substantially decreased risk of pneumothorax with comparable diagnostic accuracy, sensitivity, and specificity for histopathologic diagnosis of pulmonary nodules.

Adolescent↗

Comparison of needle core biopsy and fine-needle aspiration for diagnostic accuracy in musculoskeletal lesions.

CONTEXT: Needle core biopsy has been reported to be the choice of biopsy for musculoskeletal tumors. Fine-needle aspiration, on the other hand, has been widely accepted for nonmusculoskeletal tumors, but is only used in selected medical centers for musculoskeletal tumors. While fine-needle aspiration appears to have advantages to needle core biopsy in the aspects of simplicity and cost, the diagnostic accuracy should be the most critical parameter in determining the choice of biopsy. However, few studies comparing the diagnostic accuracy of these 2 biopsy methods have been performed. OBJECTIVE: This study was designed to compare the diagnostic accuracy of fine-needle aspiration and needle core biopsy in musculoskeletal tumors. DESIGN: Prospective study was performed in patients aged 10 years or older. Diagnostic accuracy was compared in 50 consecutive concurrent needle core biopsies and fine-needle aspirations of musculoskeletal lesions. RESULTS: For primary musculoskeletal lesions, fine-needle aspiration achieved a diagnostic accuracy rate of 88% for nature of lesion, 64% for specific diagnosis, 78% for histologic grading, and 74% for histologic typing. Needle core biopsy achieved an accuracy rate of 93% for nature of lesions, 83% for specific diagnosis, 83% for histologic grading, and 90% for histologic typing. Both biopsy methods have a higher diagnostic accuracy rate for high-grade tumors than for low-grade or benign lesions in determining the nature, specific diagnosis, and histologic grading. CONCLUSIONS: The needle core biopsy has a higher diagnostic accuracy than fine-needle aspiration in all aspects, including determining the nature of the tumor, establishing the histologic type and grade, and achieving a specific diagnosis.

Adolescent↗

Improving glandular coverage during prostate biopsy using a long-core needle: technical performance of an end-cutting needle.

OBJECTIVE: To compare the technical performance of a 33-mm core-length biopsy needle with that of the standard 18 mm needle, as many prostate cancers are isoechoic and in large prostates the tissue coverage with the 18 mm needle is inadequate. PATIENTS AND METHODS: A 33-mm core length BioPince VSL disposable needle (Amedic, Sweden) and a standard TruCut 18 mm needle (Medical Device Technology Inc., FL, USA) were used to take prostatic biopsies in two groups of 15 patients. The following variables were assessed for each group: mean core length, core quality, capsular coverage (one or both capsules within the specimen), and side-effects in the first week after biopsy (for the BioPince group, surveyed using a self-completed questionnaire). The results were compared with historical data from a group of 30 patients biopsied using the standard needle. RESULTS: For the BioPince and standard groups the mean (sd) core length was 19.4 (8.9) and 14.9 (5.1) mm, respectively. Four needles in the BioPince group failed to capture a sample, requiring needle replacement. The samples were fragmented in 15 of 90 (17%) and 41 of 90 (46%) biopsies in the BioPince and standard groups, respectively (P < 0.05). Specimens had both capsules present in five of 90 (6%) and four of 90 (4%), respectively. Within 7 days minor bleeding was the most common side-effect. Pain after biopsy was the only symptom showing a significant difference between the groups, at six of 15 and none (P = 0.001), respectively. The incidence of haematuria, haematospermia and rectal bleeding was similar in the two groups (P > 0.05), but fever more common (three vs none) in the BioPince group (P = 0.06). CONCLUSION: When set at a 33-mm stroke length, the BioPince needle increases the mean core length by 30%, with less fragmentation than a standard 18 mm needle. However, it has a significant failure rate for capture (27% needle replacement rate), slightly greater morbidity (pain and possibly fever) and shows no advantage in capsular coverage. Therefore, there are shortcomings with this end-cutting needle when used at 33 mm core length.

Aged↗

Single-use acupuncture needles: scanning electron-microscopy of needle-tips.

Unselected, disposable acupuncture needles from various manufacturers and retail suppliers were taken from a pool of donated and bought samples. Three needles of each type were prepared for electron-microscopy. The needle tips were inspected at two magnifications (x39.37 and x612.5): 52 electron-micrographs were taken of 31 individual needles from 11 different types. No needle-tip looked perfect and significant faults were seen in most; some appeared seriously deformed. The faults noted were: scratch marks along or across the needle, metallic scuff, lumps and irregularities in the needle surface, needle-tip stubbed or malformed, and needle point off-centre. An additional test made was to wipe a number of needles firmly on white paper tissue. Some left grey lines, and these were regarded as evidence of metallic or oily residue from the needle surface which could have been deposited in the patient. These unexpected findings, in a variety of popularly used needles from well-respected suppliers, suggest that most manufacturers need to reassess their quality control procedures.

Acupuncture Analgesia↗

Paraesthesiae during needle-through-needle combined spinal epidural versus single-shot spinal for elective caesarean section.

The aim of this study was to compare the incidence of paraesthesiae during spinal needle insertion in a needle-through-needle combined spinal-epidural (CSE) versus a single-shot spinal (SSS) technique. Eighty-nine women presenting for elective caesarean section at a tertiary referral obstetric unit were randomized to receive either needle-through-needle CSE or SSS. Equipment used was a 16 gauge/26 gauge combined spinal-epidural kit and a 26 gauge pencil-point spinal needle with introducer (both Sims Portex, Australia) The presence and distribution of paraesthesiae was recorded by an observer at spinal needle insertion and again on day one postoperatively. There were three failures to perform the intended block. One patient was lost to follow-up at postoperative day one. Seventeen of forty-six (37%) women in the needle-through-needle CSE group and four of forty-three (9%) in the SSS group had paraesthesiae upon spinal needle insertion (P < 0.05, Chi-squared test). No patient had persistent neurological symptoms at postoperative day one. We postulate that the higher incidence of paraesthesiae with needle-through-needle CSE may be related to deeper penetration of the subarachnoid space with this technique.

Adult↗

Scientific basis for selecting surgical needles and needle holders for wound closure.

Standardized reproducible tests have been devised to determine surgical needle sharpness, resistance to bending, and ductility. Three comparable groups of reverse cutting edge needles were selected from different manufacturers for measurement of these needle performance parameters. This testing demonstrated that needle diameter, manufacturing process, needle material composition, cross-sectional design, and the manufacturer were all important determinants of surgical needle performance. In addition, the biomechanics of curved surgical needle bending has been related to the clamping moment of surgical needle holders. This relationship identifies the surgical needle holder that can be used with surgical needles without deformation. The results of these studies provide a scientific basis for the selection of surgical needles and needle holders for use in surgery.

Equipment Design↗

Diagnostic impact of core-needle biopsy on fine-needle aspiration of non-Hodgkin lymphoma.

We retrospectively reviewed 74 fine-needle aspiration (FNA) cases of presumptive non-Hodgkin lymphoma (NHL). All the cases had cytology and core-needle biopsy and 53 cases had concurrent flow cytometric analysis. FNA (cytology and flow cytometry) and core-needle biopsy were evaluated independently. FNA was diagnostic of diffuse large B-cell lymphoma (DLBL) in 25% (13/53) of cases and small B-cell NHL in 15% (8/53) of cases, whereas core-needle biopsy was diagnostic of DLBL in 37% (27/74) of cases and small B-cell NHL in 8% (6/74) of cases. Subclassification of small B-cell NHL was reached in 3/6 cases by core-needle biopsy. Insufficient cases were observed in both FNA (47%; 25/53) and core-needle biopsy (28%; 21/74) groups. With the combination of FNA and core-needle biopsy, diagnostic cases of DLBL increased to 43% (32/74) and insufficient samples were reduced to 16% (12/74). There was no clear advantage in the diagnosis and classification of small B-cell NHL by adding core-needle biopsy to FNA (14%; 10/74). We conclude that core-needle biopsy is a useful adjunct to FNA in the diagnosis of DLBL and shall be encouraged. In small B-cell NHL, core-needle biopsy does not add to the diagnostic ability of FNA. Cases insufficient for diagnosis may be seen in both core-needle biopsy and FNA. A combined approach reduces the number of insufficient cases and is recommended in routine FNA practice.

Algorithms↗

A multicenter, open-label, randomized, two-period crossover trial comparing glycemic control, satisfaction, and preference achieved with a 31 gauge x 6 mm needle versus a 29 gauge x 12.7 mm needle in obese patients with diabetes mellitus.

BACKGROUND: Optimal needle length for subcutaneous insulin injection may differ for obese and nonobese patients, which could affect management of diabetes mellitus (DM). OBJECTIVE: The aim of this study was to determine whether 31 gauge (G) x 6 mm (shorter) needles are appropriate alternatives to 29 G x 12.7 mm (longer) needles in obese patients with DM. METHODS: A multicenter, open-label, randomized, 2-period crossover trial was conducted in insulin-treated patients with type 1 or 2 DM with body mass index >or=30 kg/m(2) and glycosylated hemoglobin A(1c) (HbA(1c)) concentration <or=10%. All patients used the same injection device and were randomized to receive 12 weeks of therapy with 1 injection site (thigh or abdomen) and 1 of the 2 needle lengths. Patients used the same injection site but the alternate needle during the second 12-week period. RESULTS: Sixty-two patients (31 men, 31 women; mean [SD] age, 50.5 [10.6] years; age range, 20-73 years) received treatment. Fifty-six patients completed all 24 weeks of treatment. No differences in glycemic control were found. Double-blind assessments of pain scores and leakage measurements, and results from the World Health Organization Diabetes Treatment Satisfaction Questionnaire and most sections of the Insulin Treatment Satisfaction Questionnaire (ITSQ), indicated no differences. However, patients indicated greater satisfaction with the shorter needle on the ITSQ (P < 0.001). The most common adverse event was injection-site bruising (51% [30/59] for the longer needle vs 34% [21/61] for the shorter needle; P = NS). Eighty-nine percent of patients (49/55) preferred the shorter needle (P < 0.001), and 76% (42/55) had a strong, very strong, or extremely strong preference for it. CONCLUSIONS: In obese patients, use of 31 G x 6 mm and 29 G x 12.7 mm needles produced comparable HbA(1c) values, double-blind pain and leakage scores, convenience, and ease of use. However, patients preferred the shorter needle.

Adult↗

Stereotaxic needle-core biopsy and fine-needle aspiration biopsy in the diagnosis of nonpalpable breast lesions: controversies and future prospects.

OBJECTIVE: To determine the advantages and limitations of a combined stereotaxic fine-needle aspiration biopsy and needle-core biopsy in the diagnosis of 353 nonpalpable breast lesions with special attention given to the collection of follow-up data. METHODS AND MATERIAL: 353 nonpalpable breast lesions underwent 'one pass' stereotaxic fine-needle aspiration (21 gauge needle) and needle-core biopsy (18 gauge needle) at our institution from January 1990 to October 1993. Stereotaxic biopsies were carried out by means of an 'add-on unit'. Surgical biopsy was usually recommended for highly suspicious radiologic patterns and/or needle biopsy reports classified as atypical or malignant. In all other cases mammographic follow-up was advised at 6 months and then annually for 3 years. The data were collected retrospectively during September 1995 (theoretical average follow-up of greater than 3 years). RESULTS: Following the combined needle biopsy technique procedure, surgery was recommended for 83 lesions. Fifty-four cancers were associated to these suspicious lesions. Because of changing radiological or clinical pattern during follow-up (mean follow-up: 22 months), 11 cancers were detected among the 270 lesions initially considered not to need surgery. Forty-three percent of the 65 malignant lesions were initially read as having less than highly suspicious mammographic features. There was no significant difference between the sensitivity and the specificity of one pass fine-needle aspiration biopsy (57% and 96% respectively) and needle-core biopsy (60% and 97% respectively), but noncontributive samples were not included in the false negative diagnoses and atypical samples were included in the true positive diagnoses. Of the 11 missed cancers, nine were manifested initially by clusters of calcifications. Our diagnostic approach was significantly less sensitive (P = 0.006) and less specific (P = 0.032) in cases of clusters of calcifications (31% false negative diagnoses) than in cases of soft-tissue masses (5.5% false negative diagnoses). In this study, an average delay in diagnoses of 22 months was responsible for a significantly increased percentage of axillary node positive invasive cancer (P < 0.001) and six of the 11 missed cancers were palpable at the time of the delayed diagnosis. For the nine cancers initially manifested by calcifications, the 22 months delay in diagnosis was responsible for a nonsignificant increase of microinvasive type at the expense of carcinoma in situ. CONCLUSION: Our enthusiasm with the sensitivity of this double stereotaxic needle sampling has been tempered by the results of this reanalysis in the light of a mean theoretical follow-up of three years. Our diagnostic approach was adequate in the presence of soft-tissue masses but not valid in the presence of clustered calcifications. When dealing with calcifications, multiple samplings must be done in order to improve the sensitivity of the diagnosis. Furthermore, this study does not favour the theory that the majority of mammographically detected cancers are indolent and highlights the poor sensitivity of the mammographic follow-up of nonpalpable lesions.

Biopsy, Needle↗

Paraesthesia during the needle-through-needle and the double segment technique for combined spinal epidural anaesthesia.

Paraesthesia during regional anaesthesia is an unpleasant sensation for patients and, more importantly, in some cases it is related to neurological injury. Relatively few studies have been conducted on the frequency of paraesthesia during combined spinal epidural anaesthesia. We compared two combined spinal epidural anaesthesia techniques: the needle-through-needle technique and the double segment technique in this respect. We randomly allocated 116 parturients undergoing elective Caesarean section to receive anaesthesia using one of these techniques. Both techniques were performed using a 27G pencil point needle, an 18G Tuohy needle, and a 20G multiport epidural catheter from the same manufacturer. The overall frequency of paraesthesia was higher in the needle-through-needle technique group (56.9% vs. 31.6%, p = 0.011). The frequency of paraesthesia at spinal needle insertion was 20.7% in the needle-through-needle technique group and 8.8% in the double segment technique group; whereas the frequency of paraesthesia at epidural catheter insertion was 46.6% in the needle-through-needle technique group and 24.6% in the double segment technique group.

Adult↗

[Evaluation of a lockable combined spinal-epidural device for use with needle-through-needle technique].

BACKGROUND: Recently, a new combined spinal-epidural (CSE) device has been introduced which allows the spinal needle to be extended a maximum of 15 mm beyond the Tuohy needle and locked onto the epidural needle after dural puncture. The aim of this study was to compare this lockable CSE device with the conventional CSE device, which allows the spinal needle to be extended 9 mm beyond the Tuohy needle, and to measure the length of the protrusion of the spinal needle beyond the Tuohy needle (top-to-top distance: TTD). METHODS: We studied sixty patients scheduled to undergo elective gynecological surgery and cesarean section. Patients were divided into three groups: patients in Group I (n = 20) using the conventional CSE device in gynecological surgery; patients in Group II (n = 20) using the lockable CSE device in gynecological surgery; and patients in Group III (n = 20) using the lockable CSE device in cesarean section. RESULTS: The success rate of spinal anesthesia with needle-through-needle technique was higher with the lockable CSE device (100%) than with the conventional CSE device (75%). The TTD was 7.9 +/- 1.8 (SD) cm in non-pregnant group (Group II) and 8.7 +/- 1.5 cm in pregnant group (Group III). This difference was not statistically significant. In the lockable CSE device groups (Group II and III), 10 patients (25%) had a TTD of 10 mm or more. CONCLUSIONS: The lockable CSE device improves the success rate of spinal anesthesia in needle-through-needle CSE anesthesia.

Adult↗

Needle-knife fistulotomy versus needle-knife precut papillotomy for the treatment of common bile duct stones.

BACKGROUND: The aim of this prospective study was to evaluate and compare the efficacy and safety of two different precutting techniques in the treatment of 103 consecutive patients with choledocholithiasis. METHODS: The patients were randomized into two groups. The first group included 74 patients who underwent needle-knife fistulotomy avoiding the papillary orifice followed by standard papillotomy. Fifty-two of these patients had a final diagnosis of choledocholithiasis. The second group included 79 patients who underwent needle-knife precut papillotomy starting from the papillary orifice followed by standard papillotomy. Fifty-one of these patients had a final diagnosis of choledocholithiasis. RESULTS: Precutting was successful in 90.54% of patients in the needle-knife fistulotomy group and 88.6% of patients in the needle-knife precut papillotomy group. Stone extraction without mechanical lithotripsy was achieved in 40 of 48 (83.33%) patients in the needle-knife fistulotomy group and 45 of 46 (97.82%) patients in the needle-knife precut papillotomy group (p < 0.05). For the other patients, stone extraction was achieved with the aid of a mechanical lithotriptor. Complications were as follows for the needle-knife fistulotomy and needle-knife precut papillotomy groups, respectively: bleeding, 6.75% and 5.06%; perforation, 2.7% and 2. 53%; cholangitis, 1.35% and 0; pancreatitis, 0 and 7.59% (p < 0.05); hyperamylasemia, 2.7% and 17.72% (p < 0.01); and death, 0 and 1.26%. CONCLUSIONS: Both methods are effective in the management of choledocholithiasis. When needle-knife fistulotomy is performed, however, lithotripsy is needed more often. Needle-knife fistulotomy is safer than needle-knife precut papillotomy with respect to pancreatic complications.

Adult↗