PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “phase space reconstruction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

Operation Everest II: an indication of deterministic chaos in human heart rate variability at simulated extreme altitude.

It has been shown that fluctuation of human heartbeat intervals (heart rate variability, HRV) reflects variations in autonomic nervous system activity. We studied HRV at simulated altitudes of over 6000 m from Holter electrocardiograms recorded during the Operation Everest II study (Houston et al. 1987). Stationary, approximately 30-min segments of HRV data from six subjects at sea level and over 6000 m were supplied to (1) spectral analysis to evaluate sympathetic and parasympathetic nervous system (SNS, PNS) activity, (2) the analysis of Poincaré section of the phase space trajectory reconstructed on a delayed coordinate system to evaluate whether there was fluctuation with deterministic dynamics, (3) the estimation of the correlation dimension to evaluate a static property of putative attractors, and (4) the analysis of nonlinear predictability of HRV time series which could reflect a dynamic property of the attractor. Unlike HRV at sea level, the recordings at over 6000 m showed a strong periodicity (period of about 20 s) with small cycle-to-cycle perturbation. When this perturbation was expressed on a Poincaré section, it seemed to be likely that the perturbation itself obeyed a deterministic law. The correlation dimensions of these recordings showed low dimensional values (3.5 +/- 0.4, mean +/- SD), whereas those of the isospectral surrogates showed significantly (P < 0.05) higher values (5.3 +/- 0.5) with embedding dimensions of 5.6 +/- 0.9.(ABSTRACT TRUNCATED AT 250 WORDS)

Altitude↗

Noise reduction for vocal pathologies.

A noise reduction scheme, particularly suited for the correction of vocal pathologies, is proposed. The filter makes use of concepts originated within the theory of dynamical systems and deterministic chaos. In particular, the idea of embedding scalar data in order to reconstruct a phase space is of fundamental importance here. Furthermore, the concept of an attractor as a result of dynamical constraints is exploited. In order to perform noise reduction one needs redundancy and the human voice provides it even within a phoneme, namely the smallest structural unit of speech. Due to several repetitions of a pattern called pitch inside a phoneme, separation between the pure voice signal and the noise is possible, provided the latter is uncorrelated with the former. With a proper parameter tuning, different kinds of noise can be removed. We describe the idea behind the noise reduction algorithm and present applications to vocal pathologies.

Algorithms↗

Time series analysis of ion dynamics in glassy ionic conductors obtained by a molecular dynamics simulation.

We present several characteristics of ionic motion in glassy ionic conductors brought out by time series analysis of molecular dynamics (MD) simulation data. Time series analysis of data obtained by MD simulation can provide crucial information to describe, understand and predict the dynamics in many systems. The data have been treated by the singular spectrum analysis (SSA), which is a method to extract information from noisy short time series and thus provide insight into the unknown or partially unknown dynamics of the underlying system that generated the time series. Phase-space plot reconstructed using the principal components of SSA exhibited complex but clear structures, suggesting the deterministic nature of the dynamics.

Journal Article↗

Chaos in Human Rhythmic Movement.

Rhythmic movements typical of locomotory actions are usually modeled as limit cycle dynamics, and their deviations from pure periodicity are attributed to stochastic physiological noise. In the present study, the dynamics of human rhythmic movements were found to contain more than the 2 dynamically active variables expected from limit cycle dynamics; the number depended upon the size of the limb oscillator. Observed positive Lyapunov exponents and fractal attractor dimensions indicated that the gross variability of human rhythmic movements may stem largely from low-dimensional chaotic motion on strange attractors.

degrees of freedom↗

Stochastic relaxation oscillator model for the solar cycle.

We perform a detailed analysis of the sunspot number time series to reconstruct the phase space of the underlying dynamical system. The features of this phase space allow us to describe the behavior of the solar cycle in terms of a simple relaxation oscillator in two dimensions. The absence of systematic self-crossings suggests that the complexity of the sunspot time series does not arise as a consequence of chaos. Instead, we show that it can be adequately modeled through the introduction of a stochastic fluctuation in one of the parameters of the dynamic equations.

Journal Article↗

Spontaneous ultraweak photon emission from biological systems and the endogenous light field.

Still one of the most astonishing biological electromagnetic phenomena is the ultraweak photon emission (UPE) from living systems. Organisms and tissues spontaneously emit measurable intensities of light, i.e. photons in the visible part of the electromagnetic spectrum (380-780 nm), in the range from 1 to 1,000 photons x s-1 x cm-2, depending on their condition and vitality. It is important not to confuse UPE from living systems with other biogenic light emitting processes such as bioluminescence or chemiluminescence. This article examines with basic considerations from physics on the quantum nature of photons the empirical phenomenon of UPE. This leads to the description of the non-thermal origin of this radiation. This is in good correspondence with the modern understanding of life phenomena as dissipative processes far from thermodynamic equilibrium. UPE also supports the understanding of life sustaining processes as basically driven by electromagnetic fields. The basic features of UPE, like intensity and spectral distribution, are known in principle for many experimental situations. The UPE of human leukocytes contributes to an endogenous light field of about 1011 photons x s-1 which can be influenced by certain factors. Further research is needed to reveal the statistical properties of UPE and in consequence to answer questions about the underlying mechanics of the biological system. In principle, statistical properties of UPE allow to reconstruct phase-space dynamics of the light emitting structures. Many open questions remain until a proper understanding of the electromagnetic interaction of the human organism can be achieved: which structures act as receptors and emitters for electromagnetic radiation? How is electromagnetic information received and processed within cells?

Biophysical Phenomena↗

Cardiorespiratory-resolved magnetic resonance imaging: measuring respiratory modulation of cardiac function.

A technique for cardiac- and respiratory-resolved MRI is described. A retrospectively gated-segmented acquisition scheme similar to that used in conventional cine cardiac imaging was used to collect image data that spanned both the cardiac and respiratory cycles. Raw k-space data were regridded in a cardiorespiratory phase space to allow image reconstruction at target cardiac and respiratory phases. The approach can be applied with various k-space trajectories and pulse sequences, and was implemented in this study with both a Cartesian steady-state free precession (SSFP) sequence and a radial phase-contrast (PC) pulse sequence. Free-breathing short-axis SSFP images of the heart were reconstructed at multiple respiratory and cardiac phases to illustrate separation of cardiac and respiratory motion without artifacts. A respiratory-resolved radial PC experiment was used to quantify the volumetric flow rates in the inferior vena cava (IVC), pulmonary artery (PA), and aorta (Ao) in five free-breathing normal volunteers and a positive-pressure ventilated dog. Total flow (ml/min) in each vessel was quantified as a function of respiratory phase (peak/minimum output = 1.85 +/- 0.29 (IVC), 1.36 +/- 0.15 (PA), 1.24 +/- 0.09 (Ao)). Peak flow occurred during inspiration for the IVC and PA, and during expiration for the Ao, and there was a complete pattern reversal for the positive-pressure ventilated dog.

Adult↗

Metallic and semimetallic silicon 100 nanowires.

Silicon nanowires grown along the 100 direction with a bulk Si core are studied with density-functional calculations. Two surface reconstructions prevail after exploration of a large fraction of the phase space of nanowire reconstructions. Despite their energetical equivalence, one of the reconstructions is found to be strongly metallic while the other one is semimetallic. This electronic-structure behavior is dictated by the particular surface states of each reconstruction. These results imply that doping is not required in order to obtain good conducting Si nanowires.

Journal Article↗

Clinical implementation of a Monte Carlo treatment planning system.

The purpose of this study was to implement the Monte Carlo method for clinical radiotherapy dose calculations. We used the EGS4/BEAM code to obtain the phase-space data for 6-20 MeV electron beams and 4, 6, and 15 MV photon beams for Varian Clinac 1800, 2100C, and 2300CD accelerators. A multiple-source model was used to reconstruct the phase-space data for both electron and photon beams, which retained the accuracy of the Monte Carlo beam data. The multiple-source model reduced the phase-space data storage requirement by a factor of 1000 and the accelerator simulation time by a factor of 10 or more. Agreement within 2% was achieved between the Monte Carlo calculations and measurements of the dose distributions in homogeneous and heterogeneous phantoms for various field sizes, source-surface distances, and beam modulations. The Monte Carlo calculated electron output factors were within 2% of the measured values for various treatment fields while the heterogeneity correction factors for various lung and bone phantoms were within 1% for photon beams and within 2% for electron beams. The EGS4/DOSXYZ Monte Carlo code was used for phantom and patient dose calculations. The results were compared to the dose distributions produced by a conventional treatment planning system and an intensity-modulated radiotherapy inverse-planning system. Significant differences (>5% in dose and >5 mm shift in isodose lines) were found between Monte Carlo calculations and the analytical calculations implemented in the commercial systems. Treatment sites showing the largest dose differences were for head and neck, lung, and breast cases.

Algorithms↗

Photon beam characterization and modelling for Monte Carlo treatment planning.

Photon beams of 4, 6 and 15 MV from Varian Clinac 2100C and 2300C/D accelerators were simulated using the EGS4/BEAM code system. The accelerators were modelled as a combination of component modules (CMs) consisting of a target, primary collimator, exit window, flattening filter, monitor chamber, secondary collimator, ring collimator, photon jaws and protection window. A full phase space file was scored directly above the upper photon jaws and analysed using beam data processing software, BEAMDP, to derive the beam characteristics, such as planar fluence, angular distribution, energy spectrum and the fractional contributions of each individual CM. A multiple-source model has been further developed to reconstruct the original phase space. Separate sources were created with accurate source intensity, energy, fluence and angular distributions for the target, primary collimator and flattening filter. Good agreement (within 2%) between the Monte Carlo calculations with the source model and those with the original phase space was achieved in the dose distributions for field sizes of 4 cm x 4 cm to 40 cm x 40 cm at source surface distances (SSDs) of 80-120 cm. The dose distributions in lung and bone heterogeneous phantoms have also been found to be in good agreement (within 2%) for 4, 6 and 15 MV photon beams for various field sizes between the Monte Carlo calculations with the source model and those with the original phase space.

Models, Theoretical↗

Chaotic and phase-locked responses of the somatosensory cortex to a periodic medial lemniscus stimulation in the anesthetized rat.

Field potential responses of the somatosensory cortex to a periodic medial lemniscus (ML) fiber stimulation were investigated in anesthetized rats. Since the field potential responses of the cortex depend on the depth of anesthesia, two criteria were introduced to control the depth of anesthesia. One criterion is that spindle oscillations are caused by a single shock to ML fibers, and the other is that the dominant frequency of spontaneous field potential rhythm is in the frequency range of the delta wave. Phase-lockings and chaotic responses occurred depending on stimulus parameters under the above conditions. Trajectories of the chaotic responses in the two-dimensional phase space (V, dV/dt) reconstruct strange attractors, and stroboscopic cross-sections of each attractor show stretching and folding process. Each one-dimensional strobomap of the chaotic responses is a noninvertible function with an unstable fixed point. This is undoubted evidence for chaotic responses of the somatosensory cortex in vivo. Power spectra well characterize the periodic and the chaotic responses. Positive Lyapunov exponents and low, noninteger correlation dimensions of the chaotic responses are consistent with the above evidence. Consequently, four kinds of chaotic responses were classified. A periodic-chaotic transition sequence was observed at a relatively low stimulus current when the frequency of the stimulation was varied. A cascade of period-doubling bifurcations was also observed on a route from the region of the 1:1 phase-locking to one of the regions of the chaotic responses.

Anesthesia↗

Chaos analysis of electro encephalography and control of seizure attack of epilepsy patients.

In order to evaluate the EEG of patients with epilepsy, chaos analysis was performed for the subdural EEG time series data. The chaos attractor was reconstructed in the phase space and the correlation dimension. KS entropy calculated from the Lyapunov exponents was evaluated. Before the seizure attack, the KS entropy showed a lower value when compared with the time series data recorded during healthy condition. The results of our study suggest that it is possible to predict the seizure attack by the chaos analysis of the EEG signal. Further, we aim at developing an automatic control system for predicting a seizure attack by the use of local cooling of the focus with Peltier elements.

Algorithms↗

Modelling 6 MV photon beams of a stereotactic radiosurgery system for Monte Carlo treatment planning.

The goal of this work is to build a multiple source model to represent the 6 MV photon beams from a Cyberknife stereotactic radiosurgery system for Monte Carlo treatment planning dose calculations. To achieve this goal, the 6 MV photon beams have been characterized and modelled using the EGS4/BEAM Monte Carlo system. A dual source model has been used to reconstruct the particle phase space at a plane immediately above the secondary collimator. The proposed model consists of two circular planar sources for the primary photons and the scattered photons, respectively. The dose contribution of the contaminant electrons was found to be in the order of 10(-3) of the total maximum dose and therefore has been omitted in the source model. Various comparisons have been made to verify the dual source model against the full phase space simulated using the EGS4/BEAM system. The agreement in percent depth dose (PDD) curves and dose profiles between the phase space and the source model was generally within 2%/1 mm for various collimators (5 to 60 mm in diameter) at 80 to 100 cm source-to-surface distances (SSD). Excellent agreement (within 1%/1 mm) was also found between the dose distributions in heterogeneous lung and bone geometry calculated using the original phase space and those calculated using the source model. These results demonstrated the accuracy of the dual source model for Monte Carlo treatment planning dose calculations for the Cyberknife system.

Models, Theoretical↗

Recovering smooth dynamics from time series with the aid of recurrence plots.

A graphical method based on recurrence plots is used in the reconstruction of the phase space from a time series of measurements. It is demonstrated that if the embedding delay and dimension are correctly chosen, the recurrence plot of a smooth dynamical system has a particularly simple form. It is shown how to use recurrence plots to determine the correct embedding parameters so that reliable quantitative information can be drawn about the system generating the time series. The average line length in the plot is shown to be directly related to the prediction horizon. Furthermore, it is a numerical characteristic of the embedded series independent of the threshold used in the plot.

Journal Article↗

Estimation of nonlinear couplings on the basis of complexity and predictability--a new method applied to cardiorespiratory coordination.

Nonlinear coordination is an essential property of the complex functioning of the autonomic nervous system. Therefore, the coupled behavior of heart rate fluctuations (HRF) and respiratory movements (RM) was analyzed on the basis of their joint reconstruction in the phase space. Independence measures of complexity and predictability were approximated from the correlation integrals which enabled the strength of cardiorespiratory couplings to be quantified. These measures were validated in a simulation study of two coupled nonlinear oscillators in dependence on their coupling strength and respective synchronization effects. The cardiorespiratory coordination during quiet sleep and active sleep of newborn piglets was quantified by means of the proposed independence measures of complexity and predictability. The difference of those measures between the sleep states investigated was more significant than the difference of the respective linear coherence peaks.

Animals↗

Frequency response of multi-phase segmented k-space phase-contrast.

A theoretical analysis of the temporal frequency response of multi-phase segmented k-space phase-contrast was developed. This includes the effects of both segment duration and the number of cardiac phases that are reconstructed. An increase in the number of views per segment and the corresponding increase in segment duration results in an increased smoothing or low-pass filtering of the time-resolved flow waveform. Reconstruction of all intermediate cardiac phases makes the Nyquist sampling frequency independent of the number of views per segment. This analysis was verified experimentally using a multi-phase phase-contrast segmented k-space MR pulse sequence. This sequence reconstructs all intermediate cardiac phases and uses fractional segments at the end of the cardiac cycle if an entire segment does not fit. The use of fractional segments increases the portion of the cardiac cycle over which data are acquired.

Coronary Circulation↗

Simultaneous phase correction and SENSE reconstruction for navigated multi-shot DWI with non-cartesian k-space sampling.

Phase-navigated multi-shot acquisition and parallel imaging are two techniques that have been applied to diffusion-weighted imaging (DWI) to diminish distortions and to enhance spatial resolution. Specifically, sensitivity encoding (SENSE) has been combined with single-shot echo planar imaging (EPI). Thus far, it has been difficult to apply parallel imaging methods, like SENSE, to multi-shot DWI because motion-induced phase error varies from shot to shot and interferes with sensitivity encoding. Although direct phase subtraction methods have been introduced to correct this phase error, they generally are not suitable for SENSE reconstruction, and they cannot remove all the motion artifacts even if the phase error is fully known. Here, an effective algorithm is proposed to correct the motion-induced phase error using an iterative reconstruction. In this proposed conjugate-gradient (CG) algorithm, the phase error is treated as an image encoding function. Given the complex perturbation terms, diffusion-weighted images can be reconstructed using an augmented sensitivity map. The mathematical formulation and image reconstruction procedures of this algorithm are similar to the SENSE reconstruction. By defining a dynamic composite sensitivity, the CG phase correction method can be conveniently incorporated with SENSE reconstruction for the application of multi-shot SENSE DWI. Effective phase correction and multi-shot SENSE DWI (R = 1 to 3) are demonstrated on both simulated and in vivo data acquired with PROPELLER and SNAILS.

Algorithms↗

A Monte Carlo dose calculation tool for radiotherapy treatment planning.

A Monte Carlo user code, MCDOSE, has been developed for radiotherapy treatment planning (RTP) dose calculations. MCDOSE is designed as a dose calculation module suitable for adaptation to host RTP systems. MCDOSE can be used for both conventional photon/electron beam calculation and intensity modulated radiotherapy (IMRT) treatment planning. MCDOSE uses a multiple-source model to reconstruct the treatment beam phase space. Based on Monte Carlo simulated or measured beam data acquired during commissioning, source-model parameters are adjusted through an automated procedure. Beam modifiers such as jaws, physical and dynamic wedges, compensators, blocks, electron cut-outs and bolus are simulated by MCDOSE together with a 3D rectilinear patient geometry model built from CT data. Dose distributions calculated using MCDOSE agreed well with those calculated by the EGS4/DOSXYZ code using different beam set-ups and beam modifiers. Heterogeneity correction factors for layered-lung or layered-bone phantoms as calculated by both codes were consistent with measured data to within 1%. The effect of energy cut-offs for particle transport was investigated. Variance reduction techniques were implemented in MCDOSE to achieve a speedup factor of 10-30 compared to DOSXYZ.

Computer Simulation↗