PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “quantitative analysis”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

Gas mixing by cardiogenic oscillations: a theoretical quantitative analysis.

A quantitative theoretical model of the enhanced gas mixing secondary to cardiogenic oscillations is presented based on the concept of augmented gas transport within the tracheobronchial tree (Science 209: 609, 1980). The model assumes "well-mixed" flow in the upper airways with the enhanced mixing described by Deff = Dmol + K . ud, where Deff is the effective diffusivity; Dmol, the molecular diffusivity: K, a constant; u, the root-mean-square flow; and d, the airway diameter. In the smaller airways on analysis based on Taylor laminar dispersion is used described by Deff = Dmol + (1/192) (ud)2/Dmol. The model predicts that, in dogs, cardiogenic oscillations should enhance gas mixing about 10-fold depending on the flow rates generated by the heart. Other predictions are that the augmentation of gas mixing should be greater 1) at lower lung volumes, 2) with sulfur hexafluoride vs. helium or air, 3) after peripheral airway dilation, and 4) after central airways constriction. Theoretical predictions are very close to published experimental results where available. This model should help in the development of mathematical models of gas mixing within the lungs that will include the contribution of cardiogenic oscillations.

Mathematics↗

Age-dependent alterations in rat ventricular myocardium: a quantitative analysis.

A quantitative electron microscopic examination of the ventricular myocardium of the male Fischer 344 rat was undertaken to determine the extent of age-dependent changes in ultrastructure. Rats of 6, 16 and 30 months of age were examined using a non-biased stereological test system. Volume fractions of mitochondria, myofibrillar mass and lipid remained unchanged during aging. Dense body volume fraction increased four-fold over the period studied, while the sarcoplasmic reticulum volume increased only from 6 months to 16 months and did not change thereafter. Biochemical analysis of the specific activities of the two lysosomal enzymes, acid phosphatase and beta-glucuronidase demonstrated a differential response to aging, with acid phosphatase remaining constant and beta-glucuronidase increasing slightly. Neither enzyme activity correlated with the pronounced change in dense body volume fraction. This study provides clear evidence that the previously observed changes in cardiac performance associated with aging are not readily explicable on the basis of a degradation of cardiac ultrastructure.

Acid Phosphatase↗

Eye movements in schizophrenia: a quantitative analysis.

A quantitative comparison of smooth pursuit eye movements of acute and chronic schizophrenics was made. Horizontal, vertical, diagonal, and pendulum tracking targets with constant or variable velocity were presented. The frequency of saccades as well as the magnitude of the spatial and temporal error during tracking was significantly greater among schizophrenics than among normals. Yet the differences between acutes and chronics were not generally significant. Performance differences were generally unaffected by the type of stimulus. The frequency of nontracked half-cycles and eye blinks was greater for chronics than for acutes or normals, and greater for acutes than normals, suggesting that sustained voluntary attention was more difficult for schizophrenics in general and chronic schizophrenics in particular. A distinctive pattern of saccade bursts was observed in the fixation and tracking records of schizophrenic subjects. These bursts were suggestive of an oculomotor deficit.

Acute Disease↗

[DNA quantitative analysis of head and neck tumor].

OBJECTIVE: This research discussed the diagnostic value of cellular quantitative analysis in head and neck tumor. METHOD: We analysis quantitative parameters of 23 malignant tumors and 20 benign diseases with automated DNA image cytometry, they are the DNA Index (DI), S-phase Fraction (SPF), Proliferation Index (PI) and 5c Exceeding (5c Ex). RESULT: The masculine rate of cellular quantitative analysis and conventional method are 76.92% and 50.00%. The value of SPF, PI and 5c Ex are 14.05%, 19.59% and 1.59% in malignant tumor, respectively. The parameters of SPF and PI showed distinct difference in the area of malignant tumor than the 1 cm sideward area of tumor and the edge of tumor. CONCLUSION: Automatic DNA image cytometry has higher masculine rate of malignant tumor than conventional method in early detection of tumor. The cellular quantitative parameters, such as SPF, PI and 5c Ex, are able to guide clinical work, specially in diagnosing of head and neck tumor, estimating biological character of malignant tumor and evaluating the area of excision.

Cell Nucleus↗

Is quantitative analysis superior to visual analysis of planar thallium 201 myocardial exercise scintigraphy in the evaluation of coronary artery disease? Analysis of a prospective clinical study.

Quantitative analysis of myocardial exercise scintigraphy has been previously reported to be superior to visual image interpretation for detection of the presence and extent of coronary artery disease. Computer analysis of perfusion defects and washout rate of thallium 201 was performed on scintigrams from a group of 131 consecutive patients (prospective group), using criteria defined from a previous group of 72 patients (initial group), and compared with visual interpretation of scintigrams for detection and evaluation of coronary artery disease. The sensitivity of the quantitative technique with regard to overall detection of coronary artery disease was not significantly different from the visual method (69% and 74%, respectively), whereas the specificity was higher (86% and 68%). Quantitative analysis did not increase the sensitivity of thallium imaging over the visual method in the left anterior descending artery (46% vs 65%) and the right coronary artery (51% vs 72%) but did increase sensitivity in the left circumflex artery (75% vs 47%). Whereas in the initial group quantitative analysis resulted in a better identification of multivessel disease (sensitivity 81% vs 57%), in the prospective group sensitivity decreased (54% vs 67%) without significant loss of specificity. The initial group had a 40% incidence of three-vessel disease and the prospective group, 22% (P less than 0.05). One-vessel disease was higher in the prospective group (32% vs 11%, P less than 0.05). Thus, assessing the quantitative technique in a larger prospective patient population, there was no improvement of detection of the presence and extent of coronary artery disease when compared with visual interpretation.

Coronary Disease↗

[Susceptibility test to rifampin by using quantitative analysis of Mycobacterium tuberculosis mRNA].

OBJECTIVE: To evaluate the significance of quantitative analysis of Mycobacterium tuberculosis mRNA in the test of susceptibility of Mycobacterium tuberculosis strains to rifampin. METHODS: The susceptibility to rifampin of fifty-three clinical isolated strains was test by the percentage of Mycobacterium tuberculosis 85B mRNA copies before and after the use of rifampin, and 1% and 10% were used as the standards for drug resistance, which was compared with the absolute concentration method. Among them, 29 were rifampin resistant strains and 24 rifampin sensitive strains. RESULTS: When the concentration of rifampin was 1 micro g/ml, and 1% and 10% were used as the standards, the accuracy of quantitative analysis of Mycobacterium tuberculosis mRNA with the absolute concentration method was 70% and 81% respectively, and the sensitivity of quantitative analysis of Mycobacterium tuberculosis mRNA was 100% and 100% respectively, while the specificity of quantitative analysis of Mycobacterium tuberculosis mRNA was 33% and 58%. When the concentration of rifampin was 2 micro g/ml, the accuracy of quantitative analysis of mRNA with the absolute concentration method was 85% and 93% respectively, and the sensitivity was 100% and 97% respectively, while the specificity was 67% and 88% respectively. When the concentration of rifampin was 4 micro g/ml, the accuracy was 93% and 93%, and the sensitivity was 93% and 93%, while the specificity was 92% and 92%. CONCLUSIONS: Quantitative analysis of Mycobacterium tuberculosis mRNA was a rapid, sensitive method in rifampin resistance screening. We suggest that the critical concentration of rifampin be 2 micro g/ml, and the critical proportion of mRNA copy be 10%.

Antibiotics, Antitubercular↗

Discordance of visual and quantitative analysis regarding false negative and false positive test results in thallium-201 myocardial perfusion scintigraphy.

Visual assessment and quantitative analysis of exercise thallium-201 myocardial perfusion scintigraphy was performed in 203 consecutive patients who underwent coronary arteriographic studies to identify the factors associated with false negative and false positive studies. Also the discordance between visual and quantitative analysis was evaluated. One hundred sixty-two (80%) of these 203 patients had significant coronary artery disease (CAD), i.e. a luminal stenosis greater than or equal to 50%. Fifty-two (32%) of these 162 patients with documented CAD showed negative thallium results either by visual or quantitative analysis. When interpreted visually 36/162 (22%) of patients were judged as negative, and when analyzed quantitatively 41/162 (25%) of patients were judged as negative (ns). Of the total group of 52 patients with false negative visual and/or quantitative analysis test results, 27 (17%) showed discordance between these two methods. Of the 41 patients without significant CAD, 12 (29%) showed positive thallium findings. Visual interpretation was positive in 9/41 (22%) of patients without significant CAD, and quantitative analysis in 5/41 (12%) (ns). Of the total group of 12 patients with positive visual and/or quantitative analysis test results, 10 (24%) showed discordance between these two methods. Therefore, in the total group, 37 patients (18%) showed discordance between visual and quantitative analysis. It is concluded that 1) the sensitivity and the specificity of visual interpretation and quantitative analysis of thallium-201 exercise scintigraphy for detecting CAD is similar, and 2) that there is frequent discordance of visual interpretation and quantitative analysis in thallium-201 exercise scintigraphy.

Coronary Disease↗

Combining fluorescence detection and mass spectrometric analysis for comprehensive and quantitative analysis of redox-sensitive cysteines in native membrane proteins.

Monobromobimane (MBB) is a lipophilic reagent that selectively modifies free cysteine residues in proteins. Because of its lipophilic character, MBB is capable of labeling cysteine residues in membrane proteins under native conditions. Reaction of MBB with the sulfhydryl groups of free cysteines leads to formation of highly fluorescent derivatives. Here we describe a procedure for the detection and relative quantitation of MBB-labeled cysteines using fluorescence and mass spectrometric analyses, which allow determination of free cysteine content and unambiguous identification of MBB-modified cysteine residues. We have applied this approach to the analysis of the free and redox-sensitive cysteine residues of a large membrane protein, the sarcoplasmic reticulum Ca2+ release channel with a molecular mass of 2.2 million Da. Labeling was performed under physiologic conditions where the channel complex is in its native environment and is functionally active. The purified MBB-labeled channel complex was enzymatically digested, and the resulting peptides were separated by reversed-phase high-performance chromatography. MBB-labeled peptides were detected by fluorescence and identified by matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. Under MALDI conditions, partial photolytic fragmentation of the MBB-peptide bound occurred, thus allowing convenient screening for the MBB-modified peptides in the MS spectrum by detection of the specific mass increment of 190.07 Da for MBB-modified cysteine residues. Modification of the peptides was further confirmed by tandem mass spectrometric analysis, utilizing sequencing information and the presence of the specific immonium ion for the MBB-modified cysteine residues at m/z 266.6. Quantitative information was obtained by comparison of both fluorescence and MS signal intensities of MBB-modified peptides. Combination of fluorescence with MS detection and analysis of MBB-labeled peptides supported by a customized software program provides a convenient method for identifying and quantifying redox-sensitive cysteines in membrane proteins of native biological systems. Identification of one redox-sensitive cysteine (2327) in the native membrane-bound sarcoplasmic reticulum Ca2+ release channel is described.

Animals↗

Retrospective image-based gating of intracoronary ultrasound images for improved quantitative analysis: the intelligate method.

Quantitative analysis of intracoronary ultrasound (ICUS) studies is performed on a series of tomographic cross-sectional ICUS images acquired during a motorized 0.5 mm/sec catheter pullback. Catheter displacement in the vascular lumen during the cardiac cycle causes an anatomically shuffled ICUS study, which results in a sawtooth-shaped appearance of the coronary segment in longitudinal reconstructed views in quantitative coronary ultrasound software packages. This hampers contour detection and leads to a laborious time-consuming semiquantitative analysis process that may produce inaccurate results. To solve these problems, in the past, online ECG-gated acquisition hardware has been applied. This article describes a novel image-based gating method called Intelligate, which features automatic retrospective selection of end-diastolic frames from videotaped or digitally stored ICUS studies. Our evaluation shows that there are no quantitative differences between analysis results of hardware ECG-gated and Intelligated ICUS studies.

Coronary Circulation↗

[Does semi-quantitative analysis of FDG-PET have any additional value in the diagnosis of mesial temporal sclerosis?].

UNLABELLED: The aim of this study was to compare qualitative visual analysis with semi-quantitative analysis in the diagnosis of mesial temporal sclerosis (MTS) using FDG-PET. METHODS: This study included 21 patients with histopathological confirmation of MTS. FDG-PET visual analysis data were based on clinical reports generated soon after the completion of the scan. FDG-PET images were semi-quantitatively analyzed using regions of interest (ROIs) in 19 slices perpendicular to the longest axis of the temporal lobe. These ROIs divided each temporal lobe into three regions (lateral, inferior and medial). An asymmetry index was calculated for each region. RESULTS: The visual analysis of the FDG-PET studies demonstrated asymmetric hypometabolism in all patients. All but 1 patient underwent standard lobectomy of the same side described as hypometabolic by the PET report. Using an asymmetry index equal or greater than 9% in at least one of the regions as a threshold, the FDG-PET semi-quantitative analysis showed significant asymmetry in 18 patients. These also matched the side of lobectomy and were confirmed as sclerotic in all but one patient (same patient as above). CONCLUSION: The semi-quantitative analysis did not provide additional information over visual interpretation in this series of patients.

Adolescent↗

Quantitative analysis of aberrant p16 methylation using real-time quantitative methylation-specific polymerase chain reaction.

We have developed a quantitative method for methylation analysis of the p16 gene based on real-time methylation-specific PCR (MSP). Real-time MSP is sensitive enough to detect down to 10 genome equivalents of the methylated p16 sequence. Application of real-time MSP to DNA from tumor-derived cell lines revealed complete concordance with conventional MSP analysis. Quantitative data generated by real-time MSP were expressed as the methylation index, which was defined as the percentage of bisulfite-converted DNA that consisted of methylated target sequences. The methylation index was shown to be inversely correlated with p16 gene transcription during demethylation treatment of cell lines with 5-aza-2'-deoxycytidine. The application of real-time MSP to bone marrow aspirates from patients with multiple myeloma revealed complete concordance with conventional MSP analysis. Real-time quantitative MSP may have applications in elucidating diverse biological processes involving DNA methylation and may become a valuable diagnostic tool for detecting tumor-associated epigenetic changes in cancer patients.

DNA Methylation↗

Decomposition and quantitative analysis of clinical electromyographic signals.

Procedures for the quantitative analysis of clinical electromyographic (EMG) signals detected simultaneously using selective or micro and non-selective or macro electrodes are presented. The procedures first involve the decomposition of the micro signals and then the quantitative analysis of the resulting motor unit action potential trains (MUAPTs) in conjunction with the associated macro signal. The decomposition procedures consist of a series of algorithms that are successively and iteratively applied to resolve a composite micro EMG signal into its constituent MUAPTs. The algorithms involve the detection of motor unit action potentials (MUAPs), MUAP clustering and supervised classification and they use shape and firing pattern information along with data dependent assignment criteria to obtain robust performance across a variety of EMG signals. The accuracy, extent and speed with which a set of 10 representative 20-30 s, concentric needle detected, micro signals could be decomposed are reported and discussed. The decomposition algorithms had a maximum and average error rate of 2.5% and 0.7%, respectively, on average assigned 88.7% of the detected MUAPs and took between 4 to 8 s. Quantitative analysis techniques involving average micro and macro MUAP shapes, the variability of micro MUAPs shapes and motor unit firing patterns are described and results obtained from analysis of the data set used to evaluate the decomposition algorithms are summarized and discussed.

Action Potentials↗

A high-spatial-resolution laser beam densitometer for quantitative analysis of polyacrylamide gels.

Quantitative analysis of proteins separated on polyacrylamide gels requires the use of an accurate, sensitive scanning device. An easily constructed, high-resolution laser beam densitometer is described in this report. The apparatus was built from readily obtainable but precision optical, electronic, and mechanical components. It was designed for and successfully applied to analysis of microslab gels, but also can be used for scanning of cylindrical gels, autoradiographs, and, with simple modification, larger slab gels.

Acrylic Resins↗

Quantitative analysis in molecular diagnostics.

Quantitative analysis of DNA products derived from polymerase chain reaction (PCR)-based assays depends on the careful optimization of each of the reaction parameters to achieve highly efficient amplification of target sequences. In practice, however, measurement of the accumulated PCR product is reliable only when analyses are performed at points in the exponential phase of the PCR amplification curve and before the onset of the plateau phase. The recent development of more sensitive DNA product detection systems has permitted the analysis of PCR assays after fewer amplification cycles, where the accumulation of product approaches linearity, while at the same time maintaining superior assay specificity. These methods include the use of high performance liquid chromatography, automated fluorescence detection, electrochemiluminescence, and the ligase chain reaction. Clinical applications of these methods are numerous and include diagnostic testing as well as therapeutic monitoring for neoplastic, infectious, and inherited genetic disease.

Biomarkers, Tumor↗

Quantitative analysis of cardiac arrhythmias.

Quantitative analysis of cardiac arrhythmias has been the subject of intensive research during the last 10 years. Several systems have been designed to help in the processing of cardiac signals: single or multiple lead electrocardiograms (ECG), electrograms from intracardiac catheters, esophageal recordings, etc. The main objective of these developments was oriented toward positive identification of arrhythmias or rhythm-disturbance counts to imitate the cardiologist's interpretation in contexts such as routing ECG and ambulatory recordings. However, these systems were mainly measurement tools aimed at extracting auricular and ventricular depolarization timings plus gross morphology description. The domain of morphology analysis of beat-to-beat auricular depolarization on ECG has never been highly active due to poor signal conditions. For routine ECG, automatic interpretation was set as an objective to complement computer-assisted ECG interpretation of conduction problems (i.e., morphology analysis of a representative beat extracted or averaged from the dominant rhythm). The limitations of rhythm interpretation in this context are well known. In the ambulatory ECG context, the analysis procedures are relatively simple and are often summarized as trivial counts describing, most exclusively, the ventricular arrhythmic behavior of the heart over a relatively long duration. Waveform-detection and measurement have been the bottleneck of advancement in arrhythmia analysis since highly reliable detection of events on a beat-to-beat basis are necessary to perform a valid analysis. Rare approaches have proposed probabilistic definition of event detection. The present review puts emphasis on the potential of several methods which have been demonstrated as powerful in identifying short- or long-duration heartbeat patterns, mode of heartbeat initiation, mode of heartbeat coupling, etc. Globally, these methods are referred to as time series analysis, modeling of rhythm patterns, simulation, and pattern recognition. A delay in the advancement of the study of arrhythmogenesis and limiting the analysis of arrhythmias to textbook descriptions is not justified when put in perspective of the potential of implementing powerful techniques which have been more or less neglected or used in a narrow way.

Arrhythmias, Cardiac↗

ISSLS prize winner: The innervation of the intervertebral disc: a quantitative analysis.

OBJECTIVE: The first quantitative analysis of the innervation of the lumbar intervertebral disc is presented. METHODS: A sheep model was used allowing evaluation of the whole motion segment. Four sheep spines were used. One was processed for PGP 9.5 immunofluorescence and three were processed for PGP 9.5 immunoperoxidase histochemistry. A count was made of the densities of innervation of the endplate and anulus, and these were compared. RESULTS: There is no significant difference between endplate and anulus innervation densities. The endplate innervation is concentrated centrally adjoining the nucleus. The richest area of innervation is in the perianular connective tissue. DISCUSSION: The lumbar intervertebral disc has a meager innervation. This is concentrated in the perianular connective tissue and the central endplate. Although receptor threshold is more closely related to nociceptive function than innervation density, these findings have important implications for any treatment of discogenic pain.

Animals↗