PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “single platform”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3Linked to original sources

Pyrosequencing: an accurate detection platform for single nucleotide polymorphisms.

Pyrosequencing, a non-electrophoretic method for DNA sequencing, is emerging as a popular platform for analysis of single nucleotide polymorphisms (SNPs). This technology has the advantage of accuracy, ease-of-use, and high flexibility for different applications. Here, we review the methodology and the use of this technique for SNP genotyping, SNP discovery, haplotyping, and allelic frequency studies. In addition, we describe new schemes for template preparation and multiplexing as an effort for cost reduction in large-scale studies.

Alleles↗

A simplified flow cytometry method of CD4 and CD8 cell counting based on thermoresistant reagents: implications for large scale monitoring of HIV-infected patients in resource-limited settings.

OBJECTIVE: To validate a simplified flow cytometry assay for CD4 and CD8 T cell counting based on monoclonal antibodies which are made resistant to high temperatures (simplified thermoresistant assay (STRA)). METHOD: The STRA employs FITC-conjugated anti-CD4 and anti-CD8 monoclonal antibodies, predispensed into test tubes and chemically treated to be resistant to high temperatures. Five correlation studies were performed in three different laboratories on a total of 560 blood samples from HIV-1 infected patients. Each study correlated the STRA with either double or single platform assays currently available. Accelerated stability tests on the FITC-conjugated monoclonal antibodies were performed to assess the resistance of the STRA to high temperatures. RESULTS: Comparison of STRA with both single platform and double platform assays gave correlation coefficients ranging 0.957-0.987 for CD4+ T cells and 0.946-0.968 for CD8+ T cells. In all correlation studies there was a perfect data overlapping in the low-pathological interval of CD4+ T cells (0-400 cells/ml). The FITC-conjugated CD4 and CD8 monoclonal antibodies maintained intact binding activity and fluorescence brightness after storage for 4 weeks at 45 degrees C and can be stored for up to 8 years in regular conditions (+4 degrees C). CONCLUSIONS: The STRA correlates well with both single-platform and double-platform flow-cytometry assays currently used to assess CD4+ T cells. The test procedure is simple, rapid, and easy to perform. The reagents can be stored under unfavorable environmental conditions for long period of time. These features should facilitate access to flow cytometry testing in resource-poor settings.

Antibodies, Monoclonal↗

A single lentiviral vector platform for microRNA-based conditional RNA interference and coordinated transgene expression.

RNAi is proving to be a powerful experimental tool for the functional annotation of mammalian genomes. The full potential of this technology will be realized through development of approaches permitting regulated manipulation of endogenous gene expression with coordinated reexpression of exogenous transgenes. We describe the development of a lentiviral vector platform, pSLIK (single lentivector for inducible knockdown), which permits tetracycline-regulated expression of microRNA-like short hairpin RNAs from a single viral infection of any naïve cell system. In mouse embryonic fibroblasts, the pSLIK platform was used to conditionally deplete the expression of the heterotrimeric G proteins Galpha12 and Galpha13 both singly and in combination, demonstrating the Galpha13 dependence of serum response element-mediated transcription. In RAW264.7 macrophages, regulated knockdown of Gbeta2 correlated with a reduced Ca(2+) response to C5a. Insertion of a GFP transgene upstream of the Gbeta2 microRNA-like short hairpin RNA allowed concomitant reexpression of a heterologous mRNA during tetracycline-dependent target gene knockdown, significantly enhancing the experimental applicability of the pSLIK system.

Animals↗

Structural features of a snake venom thrombin-like enzyme: thrombin and trypsin on a single catalytic platform?

The Lachesis muta thrombin-like enzyme (LM-TL) is a single chain serine protease that shares 38% sequence identity with the serine protease domain of thrombin and also displays similar fibrinogen-clotting activity. In addition, the 228 amino acid residue LM-TL is 52% identical to trypsin, and cleaves chromogenic substrates with similar specificity. Herein we report a three-dimensional (3D) model validated experimentally for LM-TL based on these two homologous proteins of known 3D structure. Spatial modeling of LM-TL reveals a serine protease with a chymotrypsin fold presenting a hydrophobic pocket on its surface, involved in substrate recognition, and an important 90's loop, involved in restricting the LM-TL catalytic site cleft. Docking analysis showed that LM-TL would not form a stable complex with basic pancreatic trypsin inhibitor and wild-type ecotin since its 90's loop would restrict the access to the catalytic site. LM-TL formed acceptable interactions with fibrinopeptide A and a variant of ecotin; ecotin-TSRR/R in which both the primary and secondary binding sites are mutated Val81Thr, Thr83Ser, Met84Arg, Met85Arg and Asp70Arg. Furthermore, analysis of the primary structures of LM-TL and of the seven snake venom thrombin-like enzymes (SVTLEs) family reveals a subgroup formed by LM-TL, crotalase, and bilineobin, both closely related to thrombin. Therefore, LM-TL provides an initial point to compare SVTLEs with their counterparts, e.g. the mammalian serine proteases, and a basis for the localization of important residues within the little known SVTLEs family.

Amino Acid Sequence↗

Sleep deprivation induced by the modified multiple platform technique: quantification of sleep loss and recovery.

Vigilance status was continually monitored in socially stable groups of rats exposed to the modified multiple platform (MMP) technique for sleep deprivation. For comparison, sleep parameters were also monitored in socially isolated rats deprived of sleep by the single platform (SP) method. In all cases, sleep was continuously recorded during baseline, during 96 h of sleep deprivation and during 4 days of recovery. Both multiple- and single-platform techniques completely abolished paradoxical sleep (PS) during the deprivation period, but also resulted in significant decreases in slow wave sleep (SWS) (-31% and -37%, respectively). Unexpectedly, animals on large platforms, which are normally intended as controls, also showed significant reductions in PS and SWS, and these effects were more pronounced in rats deprived in groups than in animals deprived in isolation. Another control preparation, rats placed on wire-mesh grids in the deprivation tank, also showed PS reduction (-39%) but no loss of SWS during the 4 test days. Paradoxical sleep rebound was observed in the first 24 h in all groups, except for grid controls. Overall, no significant differences were found between single- and multiple-platform procedures during the 4 days of deprivation. However, sleep rebound was more pronounced in MMP-deprived rats than in SP-deprived rats. Sleep loss in both control groups may reflect residual effect of stress that remain in the platform technique. These findings indicate that the MMP technique is effective in inducing PS deprivation (PSD). However, the fact that SWS is also affected may have implications for conclusions on paradoxical sleep function based upon paradoxical sleep deprivation.

Animals↗

Functionalized self-assembled monolayers on ultraflat gold as platforms for single molecule force spectroscopy and imaging.

Single molecule force spectroscopy is a valuable tool for studying unfolding and nanomechanical properties of proteins. The common practice is to stretch proteins from a surface that was dosed to give a reasonable hit rate and to analyze the curves that exhibit the expected characteristics of a single polymer. Whether the surface-bound proteins are indeed single and isolated remains unclear, and the undesirable protein/surface interactions that obscure informative features of the force curves are implicitly assumed to be absent. In this study, mixed self-assembled monolayers (SAMs) consisting of N-hydroxysuccinimide (NHS) and oligoethylene glycol (OEG) terminated thiols on an ultraflat gold surface were used to covalently immobilize proteins via lysine residues. By the optimization of attachment sites via lysine-NHS linkages amidst a protein-resistant layer of the OEG SAM, it was possible to isolate single proteins for study in a controlled fashion. The single protein distribution on the surface is clearly demonstrated by atomic force microscopy (AFM) imaging. The OEG also significantly reduces nonspecific tip-surface interactions between the cantilever and surface. Stretching covalently attached single proteins produces high-quality and reproducible force-extension curves. This experimental strategy is an attractive platform with which to study protein structure, interactions, and nanomechanical properties of single proteins.

Gold↗

The impact of erythrocyte lysing procedures on the recovery of hematopoietic progenitor cells in flow cytometric analysis.

Since preanalytic lysing of erythrocytes remains critical in flow cytometry, we investigated the influence of four lysing procedures on the quantification of leukocyte and CD34+ cells in hematopoietic cell transplants (HCTs). Samples were derived from stem cell-enriched mobilized whole blood collected by apheresis (unselected) and immunologically purified stem cell products (selected) and were measured using the dual-platform (2-PF) method with two flow cytometric systems. Additionally, cells were measured by a volume-based technique (single platform [1-PF]). Results were identical in the 2-PF mode (unselected HCTs, r = 0.998; selected HCTs, r = 0.999). In comparison with the 2-PF results, the single-platform (1-PF) measurements revealed a mean decrease of 59.5% for CD34+ cells (50.8% for CD45+ cells) in unselected HCTs and a mean decrease of 52% for CD34+ cells (49.8% for CD45+ cells) in selected HCTs. In order to check the accuracy of cell quantification using the 1-PF method, leukocyte reference values from hematology counter results were compared with flow cytometric (1-PF)-counted nucleated cells. That analysis revealed good congruency, with r = 0.998 for unselected HCTs and r = 0.999 for selected HCTs. In conclusion, all lysing procedures that we used induced substantial loss of leukocytes and CD34+ cells. As demonstrated by the high accuracy of the 1-PF technique, all erythrocyte lysing procedures caused significant cell loss, which led to inconsistent counting of CD34+ cells in nonvolumetric flow cytometric (2-PF) protocols.

Adolescent↗

Assessing agreement between CD34 enumeration by flow cytometry and volumetric analysis.

Prior to replacement of an established method for CD34 enumeration by an alternative approach, evaluation of the agreement between the methods is essential. In this study, the comparison of two assays was evaluated according to the recommendation of Bland and Altman describing the agreement between two methods where the true value is not known. CD34 enumeration was performed on blood or leukapheresis product from 105 patients by flow cytometry (dual platform assay) and volumetric analysis (single platform assay). Both the flow cytometric and the volumetric analysis showed poor reproducibility for measures lower than approximately 9 CD34+ cells/mm3. For values higher than 29 CD34+ cells/mm3, evaluation of the agreement demonstrated a difference between the single and dual platform assay, where CD34 enumeration by the volumetric analysis demonstrated values 73-80% of the flow cytometric value. The difference between the two assays could be due to several technical pitfalls which are discussed.

Antigens, CD34↗

Quality control of CD4+ T-lymphocyte enumeration: results from the last 9 years of the United Kingdom National External Quality Assessment Scheme for Immune Monitoring (1993-2001).

The human immunodeficiency virus (HIV) global epidemic has necessitated the routine enumeration of T-lymphocyte subsets, which has created a need for external quality assurance (EQA). The United Kingdom National External Quality Assessment Scheme (UK NEQAS) for Immune Monitoring provides EQA for 296 laboratories in 40 countries. In 1993, UK NEQAS developed and incorporated into its program stabilized whole blood that enables the accurate monitoring of laboratory performance. Overall, the mean interlaboratory coefficient of variation (CV) for percentage CD4(+) T-lymphocyte subset enumeration has fallen from 15% to less than 5%, as a direct result of the increased use of CD45/ side scatter (SSC) gating. Laboratories using alternative gating strategies (i.e., CD45/CD14 or forward scatter [FSC]/SSC) were about 7.4 times more likely to fail an EQA exercise. Furthermore, the adoption of single-platform technology resulted in a reduction of the overall mean interlaboratory CV for absolute CD4(+) T lymphocytes from 56% (prior to the widespread use of single-platform technology) to 9.7%. Individual laboratory deficiencies were also identified using a performance monitoring system and, through re-education by collaboration with the coordinating center, satisfactorily resolved. In conclusion, during the last 9 years, the UK NEQAS for Immune Monitoring program has highlighted the significant technological advances made by laboratories worldwide that undertake lymphocyte subset enumeration.

CD3 Complex↗

Absolute CD4 T-cell counting in resource-poor settings: direct volumetric measurements versus bead-based clinical flow cytometry instruments.

Flow cytometry is an accurate but expensive method to determine absolute CD4 cell counts. We compared different methods to measure absolute CD4 counts in blood samples from HIV-infected and uninfected subjects using a research/clinical flow cytometer (FACScan); a dedicated clinical instrument (FACSCount); and a volumetric, mobile, open-system flow cytometer equipped with 3 fluorescence and 2 light scatter detectors (Cyflow SL blue). The FACScan and Cyflow were used as single-platform instruments, but they differ in running cost, which is a central factor for resource-poor settings. Direct volumetric and bead-based CD4 measurements on the Cyflow were compared with 2 bead-based single-platform CD4 measurements on the FACSCount and on FACScan (TruCount) in "Le Dantec" Hospital, Dakar, Senegal, using whole blood samples from 102 HIV+ and 28 HIV- subjects. The agreement between the various measurement methods was evaluated by Bland-Altman analysis. Volumetric CD4 measurements on the Cyflow using a no-lyse-no-wash (NLNW) procedure and a lyse-no-wash (LNW) procedure correlated well with each other (R2 = 0.98) and with CD4 measurements on the FACSCount (R2 = 0.97) and FACScan (R2 = 0.97), respectively. Red blood cell lysis had no negative effect on the accuracy of absolute CD4 counting on the Cyflow. An excellent correlation was observed between bead-based CD4 measurements on the Cyflow and CD4 measurements on the FACSCount (R2 = 0.99) and FACScan (R2 = 0.99). Rigid internal and external quality control monitoring and adequate training of technicians were considered essential to generate accurate volumetric CD4 measurements on the Cyflow.

Belgium↗

An accurate, single, platform-level impression technique for the fabrication of prosthetic restorations on dental implants.

The possibility of restorative inaccuracies increases with the number of impressions taken and subsequent models poured. Herein we describe a unique, splinted, dual-arch pick-up impression technique using abutment components instead of transfer copings. In our experience, this permits the fabrication of a definitive restoration as a result of a single impression.

Dental Abutments↗

The "vanishing counting bead" phenomenon: effect on absolute CD34+ cell counting in phosphate-buffered saline-diluted leukapheresis samples.

BACKGROUND: Using a single-platform protocol to count absolute CD34+ hematopoietic precursor cell (HPC) levels with different reference microbeads, we recorded occasionally artifactually high CD34+ HPC counts in some leukapheresis bags, whereas dual-platform calculations were always consistent. Abnormal countings were observed only when phosphate-buffered saline (PBS)-diluted leukapheresis samples were vortexed before analysis. A large series of blood samples analyzed similarly for CD34+ and CD4+ absolute counts did not show any sample or vortexing effect. With the volumetric absolute counting cytometer Partec-PAS, lower counts were also observed when different reference beads were vortexed before the instrument checking procedures. The counting abnormality was caused by a drop in microbead concentration (the "vanishing bead phenomenon"). This phenomenon reduced the total and relative bead event number in experimental and routine samples and in calibration procedures. This altered the bead denominator used to calculate absolute CD34+ HPC levels and it also reduced the concentration of standard calibration beads. METHODS: Using the Partec-PAS to measure volumetrically the actual bead concentration, we studied the vanishing bead phenomenon. Different types of counting and reference microbeads were resuspended in media with or without proteins or cells. Replicates were submitted either to gentle manual mixing or to vortexing before counting. RESULTS: Vortex agitation almost invariably induced the vanishing bead phenomenon when beads were resuspended in saline media or when an insufficient protein concentration was present, such as in diluted leukapheresis samples. Different bead types showed various degrees of sensitivity to vortexing. The bead disappearance was not caused by bubble formation or disruption. The addition of small amounts of protein completely prevented the vanishing bead phenomenon. The causative effect of the electrostatic charging of tube induced by vortexing is hypothesized. CONCLUSIONS: Sample suspensions containing counting beads for single-platform analysis must be resuspended in media with protein supplements to prevent the vanishing bead phenomenon and to ensure accurate counting.

Antigens, CD34↗

Comparison of single and dual platform methodologies for the estimation of CD34+ hematopoietic progenitor cells: correlation with colony assay.

In this study three assays for the enumeration of CD34+ progenitors were compared: 1) a modified version of the Milan protocol, used in the standard dual-platform format; 2) a dual-platform version of the ISHAGE protocol; 3) the ProCOUNT software version 2.0/ProCOUNT kit. The assays were compared to validate the accuracy of CD34+ cell counts in mobilized peripheral blood (PB), apheresis products (AP), and cord blood (CB). The ProCOUNT protocol uses reference beads for absolute CD34+ cell counting, whereas CD34 counts by other techniques are derived from a separate leukocyte count performed by a hematology analyzer. A good correlation between the ISHAGE and ProCOUNT methods was obtained for estimation of CD34+ counts in PB (n=42 samples analyzed) and AP (n=35)--except for samples having a leukocyte count >25 x 10(9)/L or a CD34 count <0.0025 x 10(9)/L)--while a suboptimal correlation between the methods was observed for CB (n=30). The ProCOUNT system proved to be effective in reducing the variability in CD34+ cell counting and appeared to be useful for intralaboratory methodology standardization. The main disadvantage of the ProCOUNT assay was its inability to calculate CD34 counts in leukopenic samples and in CB samples showing a high erythroblast count. As far as the correlation with hematopoietic colonies is concerned, data collected from apheresis samples showed a good correlation between the three flow cytometry methods and colony-forming unit granulocyte-macrophage (CFU-GM) counts, confirming the value of the flow cytometric test as a real-time, truly predictive test to measure the hematopoietic potential of the graft. In summary, all methods are suitable for enumeration of most PB samples, while the single-platform methodology should be preferred for the analysis of AP and CB. We also found the dual-platform format of the ISHAGE method precise and accurate for the estimation of CD34+ cells from CB samples. Based on these data it can be concluded that the single-platform flow cytometry assay format should be the preferred approach for CD34+ stem cell enumeration in different types of samples.

Adolescent↗

Detection of E. coli using a microfluidics-based antibody biochip detection system.

This work demonstrates the detection of E. coli using a 2-dimensional photosensor array biochip which is efficiently equipped with a microfluidics sample/reagent delivery system for on-chip monitoring of bioassays. The biochip features a 4 x 4 array of independently operating photodiodes that are integrated along with amplifiers, discriminators and logic circuitry on a single platform. The microfluidics system includes a single 0.4 mL reaction chamber which houses a sampling platform that selectively captures detection probes from a sample through the use of immobilized bioreceptors. The independently operating photodiodes allow simultaneous monitoring of multiple samples. In this study the sampling platform is a cellulosic membrane that is exposed to E. coli organisms and subsequently analyzed using a sandwich immunoassay involving a Cy5-labeled antibody probe. The combined effectiveness of the integrated circuit (IC) biochip and the immunoassay is evaluated for assays performed both by conventional laboratory means followed by detection with the IC biochip, and through the use of the microfluidics system for on-chip detection. Highlights of the studies show that the biochip has a linear dynamic range of three orders of magnitude observed for conventional assays, and can detect 20 E. coli organisms. Selective detection of E. coli in a complex medium, milk diluent, is also reported for both off-chip and on-chip assays.

Animals↗

Utilising the left-helical conformation of L-DNA for analysing different marker types on a single universal microarray platform.

L-DNA is the perfect mirror-image form of the naturally occurring d-conformation of DNA. Therefore, L-DNA duplexes have the same physical characteristics in terms of solubility, duplex stability and selectivity as D-DNA but form a left-helical double-helix. Because of its chiral difference, L-DNA does not bind to its naturally occurring D-DNA counterpart, however. We analysed some of the properties that are typical for L-DNA. For all the differences, L-DNA is chemically compatible with the D-form of DNA, so that chimeric molecules can be synthesized. We take advantage of the characteristics of L-DNA toward the establishment of a universal microarray that permits the analysis of different kinds of molecular diagnostic information in a single experiment on a single platform, in various combinations. Typical results for the measurement of transcript level variations, genotypic differences and DNA-protein interactions are presented. However, on the basis of the characteristic features of L-DNA, also other applications of this molecule type are discussed.

Animals↗

Comparison of single and dual-platform assay formats for CD34+ haematopoietic progenitor cell enumeration.

Most techniques for CD34+ cell enumeration are dual platform assays. That is, they derive absolute numbers of CD34+ cells from either the flow cytometrically assessed per cent (%) CD34+ cells within the nucleated cells and/or the white blood cell count from a haematology cell analyser. Recently, so-called single-platform assays have been developed, in which the absolute number of CD34+ cells is directly derived from a single flow cytometric measurement. The present study aims to compare the variation between eight laboratories in CD34+ cell counts from paired assays of 15 samples using a common single (ProCOUNT) and the local dual-platform method. Six laboratories used the 'SIHON' and two the 'ISHAGE' protocol for CD34+ cell enumeration. Use of the single-platform method reduced the inter-laboratory variation in per cent and absolute numbers of CD34+ cells, as measured by interquartile ranges, by half but did not lead to an appreciable reduction of the inter-laboratory variation in white blood cell counts. Thus, part of the reduced inter-laboratory variation obtained with ProCOUNT may have been a result of the use of standardized procedures and reagents to detect CD34+ cells. In order to eliminate any variation arising from the use of different local protocols for percentage of CD34+ cell assessments, a comparison was made of the ProCOUNT-derived absolute CD34+ cell numbers (i.e. single platform) with the dual-platform absolute CD34+ cell numbers calculated by multiplying ProCOUNT-derived percentage of CD34+ cells and with the corresponding haematology analyser-derived white blood cell count. Regardless, the interquartile ranges of absolute CD34+ cell numbers remained almost a factor of two smaller with the use of the single platform method. Thus, these results suggest that single-platform methodology can reduce the variation in absolute CD34+ cell numbers between laboratories.

Biological Assay↗

GWFASTA: server for FASTA search in eukaryotic and microbial genomes.

Similarity searches are a powerful method for solving important biological problems such as database scanning, evolutionary studies, gene prediction, and protein structure prediction. FASTA is a widely used sequence comparison tool for rapid database scanning. Here we describe the GWFASTA server that was developed to assist the FASTA user in similarity searches against partially and/or completely sequenced genomes. GWFASTA consists of more than 60 microbial genomes, eight eukaryote genomes, and proteomes of annotatedgenomes. Infact, it provides the maximum number of databases for similarity searching from a single platform. GWFASTA allows the submission of more than one sequence as a single query for a FASTA search. It also provides integrated post-processing of FASTA output, including compositional analysis of proteins, multiple sequences alignment, and phylogenetic analysis. Furthermore, it summarizes the search results organism-wise for prokaryotes and chromosome-wise for eukaryotes. Thus, the integration of different tools for sequence analyses makes GWFASTA a powerful toolfor biologists.

Computer Systems↗