PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Angiography, Digital Subtraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30Linked to original sources

Use of digital subtraction angiography for evaluation of vascular access for hemodialysis.

We used digital subtraction angiography (DSA) with conventional methods of contrast injection to evaluate 13 failing vascular accesses in 12 patients undergoing hemodialysis. DSA results were confirmed in all cases by surgical findings and/or clinical follow-up. The DSA technique is extremely flexible and rapid and requires the injection of only small amounts of dilute contrast with much less patient discomfort. DSA is an excellent alternative to film screen angiography for the evaluation of vascular access complications.

Angiography↗

Incidence of fibrillation with dilute contrast media for intra-arterial coronary digital subtraction angiography.

State-of-the-art imaging technology such as digital subtraction angiography can produce coronary artery opacification with contrast media formulations that contain less than 170 mgI/ml. We examined the effect of electrolyte composition in such formulations on the incidence of fibrillation. Right coronary injections of contrast were made for 25 seconds in anesthetized dogs. This injection is longer than clinical injections, but the model approximates the worst condition of a wedged catheter preventing media washout. Formulations of several mixtures of meglumine and sodium diatrizoate (173 to 141 mgI/ml) and sodium diatrizoate alone (143 mgI/ml) produced fibrillation in only 10 to 20% of the injections. Meglumine diatrizoate (141 mgI/ml) and full strength meglumine/sodium diatrizoate (Angiovist 370) produced fibrillation in 100% and 50% of the injections, respectively. These animal studies demonstrate that dilute contrast media containing few or no sodium ions are more likely to induce fibrillation than Angiovist 370, whereas dilute contrast media containing sodium are the least likely to induce fibrillation.

Angiography↗

Study of isotonic contrast media in intravenous digital subtraction angiography.

Arterial enhancement obtained with isotonic contrast media in intravenous digital subtraction angiography was studied. Ten dogs were injected with ioxaglate, iopamidol, and ioxitalamate at equal iodine concentration and at concentrations corresponding to plasma osmolality. Three variables were studied: osmolality, injection rate, and iodine dose. Provided their iodine concentration is sufficient, isotonic contrast media appear as efficient as the corresponding hypertonic formulation, at equal iodine dose. Moreover, the use of isotonic ioxaglate allows a lower dose of iodine to be administered without significant reduction in peak arterial value.

Animals↗

Digital subtraction angiography: myths and reality.

Some of the claims made about digital subtraction angiography (DSA) when it was first developed have turned out to be greatly exaggerated, and some members of the radiologic community have become disillusioned with its capabilities. The author discusses some of the limitations of DSA, and concludes that the advantages of DSA outweigh its limitations.

Angiography↗

Evaluation of the processing functions of a digital subtraction angiography image processor.

A large number of imaging systems for digital subtraction angiography (DSA) are now commercially available. Numerous evaluations of the performance of these systems have been reported in the literature. However systematic evaluations of the processing functions of DSA image processors have not been widely reported. Such an evaluation for one commercial system is presented in this paper. Functions evaluated include linear transformation, logarithmic transformation, integration, subtraction and temporal filtration. The observations indicate that image processing results are frequently achieved by indirect routes which compromise the fidelity of the image data.

Angiography↗

Digital subtraction angiography with intravenous injection: assessment of 1,000 carotid bifurcations.

Digital subtraction angiography (DSA) with intravenous contrast injection was performed on 500 consecutive adult patients and evaluated for image quality of the carotid artery bifurcations. Diagnostic quality examinations were obtained in 974 common, 925 internal, and 904 external carotid artery segments. Sixty-two patients had standard carotid arteriography around the same time as DSA. Agreement of standard arteriograms with diagnostic quality DSA examinations was noted in 97 of 98 common, 94 of 95 internal, and 79 of 91 external carotid artery segments. All cases of complete carotid occlusion (14 of 14) were correctly interpreted by DSA. To identify a population with clinically significant stenosis, a 60% or greater reduction in diameter of the internal carotid was defined as a positive examination. Applying this criterion, the sensitivity, specificity, and accuracy of DSA as compared with standard arteriography was about 94%.

Adult↗

[Arterial digital subtraction angiography in the diagnosis of venous sinus thrombosis].

The transarterial digital subtraction angiography (DSA) examination of 4 patients studied for cerebral sinus venous thrombosis of the intracranial venous structures was reviewed to determine the reliability and adequacy of visualization of the venous drainage of the brain. In addition, 4 patients were specifically evaluated with DSA for venous sinus thrombosis of the intracranial veins and sinuses. Conditions studies included: Compression, or occlusion of the venous structures. Transarterial DSA is usually sufficient to replace conventional angiography in the evaluation of the cerebral sinus venous thrombosis (SVT).

Acute Disease↗

Digital subtraction angiography: image-sequence analysis for regional myocardial perfusion dynamics.

Digital subtraction angiography with selective coronary injections of contrast media has enabled us to obtain clear images, not only of the artery, but of the capillary and venous phases of the myocardial perfusion. In the present study, densitometry was used to estimate regional myocardial perfusion dynamics in 10 control cases and 11 anterior myocardial infarction cases. The time density curve showed that contrast material increased rapidly in the arterial phase and appeared to be washed out monoexponentially in the venous phase. The time from the onset of contrast medium injection to the maximal density of the contrast medium (Tp), and the time constant obtained from the washout curve (Tc) were analyzed. In the control group, Tp in the apical region was slightly prolonged as compared with Tp in the anterobasal region, but the difference was not significant (5.2 +/- 0.5 vs 4.2 +/- 0.4 sec: mean +/- SEM). Tc did not definitely change in any portion of the myocardium (anterobasal 5.1 +/- 0.5, anterior 4.8 +/- 0.5, apex 4.6 +/- 0.5 sec, respectively). In anterior myocardial infarction, Tp in the marginal region was significantly prolonged compared to Tp in the control region (6.0 +/- 0.3 vs 4.7 +/- 0.3 sec, p less than 0.01). Tp was prolonged for more than 10 sec in the infarcted region. Tc in the marginal region was markedly prolonged compared to Tc in the control region (7.4 +/- 0.9 vs 4.4 +/- 0.5 sec, p less than 0.025). Tc could not be determined in the infarcted regions because data acquisition time of our apparatus was inadequate.(ABSTRACT TRUNCATED AT 250 WORDS)

Coronary Angiography↗

Digital subtraction angiography: intravenous and intra-arterial techniques.

As experience with digital subtraction angiography (DSA) increases, both its advantages and disadvantages have become more evident. Although the intravenous approach (IV-DSA) is safer and less expensive than conventional arteriography, images are frequently suboptimal. Good-quality IV-DSAs quite accurately detect hemodynamically significant lesions (sensitivity 92% and specificity 92%) but may overlook minor stenoses and wall irregularities (negative predictive value 69%). When fine detail is not required, IV-DSA may serve as the definitive radiographic examination. The intra-arterial approach (IA-DSA), which provides better images, uses less contrast medium, decreases the need for selective catheterization, and permits visualization of vessels in areas of sluggish flow, is being used more extensively. Careful consideration of the complementary roles of DSA, conventional arteriography, and noninvasive testing is necessary to provide accurate diagnostic information at the least hazard and expense to the patient.

Angiography↗

Digital subtraction angiography in the diagnosis of arterial complications after renal transplantation.

Digital subtraction angiography (DSA) was used to study arterial complications following renal transplantation in 33 patients. The results were compared with clinical follow-up and in three cases with conventional angiography. In 9 per cent using DSA (3 cases) we experienced inadequate visualization of the renal arteries of the graft; in 91 per cent, the visualization was diagnostically sufficient. In 53 per cent, we discovered an arterial stenosis of the main artery or segmental artery and in one case an AV-fistula. No morbidity resulted during the procedure. We consider DSA to be the best non-invasive method in the evaluation of patients with suspected renal artery stenosis following kidney transplantation.

Adolescent↗

Neuroradiologic applications of intraarterial digital subtraction angiography.

In the neuroradiologic evaluation of 118 patients using intraarterial digital subtraction angiography definite advantages and disadvantages were defined. Advantages include reduction of contrast medium volume, catheter time, and patient risk and discomfort. It also aids in angiographic planning. The paramount disadvantage is less spatial resolution compared with conventional film angiography.

Aged↗

[Diagnosis of dissecting aortic aneurysm by digital subtraction angiography].

The aim of the study was to determine whether digital subtraction angiography (DSA) can be used in the diagnosis of aortic dissection. The study group consisted of six patients with aortic dissection including one of type 2 and five of type 3 by the DeBakey classification. DSA findings were compared to cineangiographic findings. The results were as follows; In all the patients, the diagnosis of aortic dissection was possible using DSA. Especially as to the entry, which was not detected by other non-invasive methods, there was an excellent correlation between cineangiograms and DSA (sensitivity 100%). Of the 20 vessels in the abdomen, which included the celiac, superior mesenteric, and right and left renal arteries, three vessels (15%) were not identified by DSA. Causes of the failure were the low spatial resolution and the artifact due to the motion of the patients and intestinal gas movement. The accuracy rate of the abdominal branch involvement was 70%. While using a prototype equipment, the preliminary study showed that DSA is a safe and very useful method not only for diagnosing aortic dissection, but for evaluation of the entry, extension of the dissection, and involvement of major branches of the abdominal aorta and for a follow-up study.

Adult↗

Rotational digital subtraction angiography of the renal arteries: technique and evaluation in the study of native and transplant renal arteries.

Rotational digital subtraction angiography (RDSA) allows multidirectional angiographic acquisitions with a single injection of contrast medium. The role of RDSA was evaluated in 60 patients referred over a 7-month period for diagnostic renal angiography and 12 patients referred for renal transplant studies. All angiograms were assessed for their diagnostic value, the presence of anomalies and the quantity of contrast medium used. The effective dose for native renal RDSA was determined. 41 (68.3%) native renal RDSA images and 8 (66.7%) transplant renal RDSA images were of diagnostic quality. Multiple renal arteries were identified in 9/41 (22%) native renal RDSA diagnostic images. The mean volume of contrast medium in the RDSA runs was 51.2 ml and 50 ml for native and transplant renal studies, respectively. The mean effective dose for 120 degrees native renal RDSA was 2.36 mSv, equivalent to 1 year's mean background radiation. Those RDSA images that were non-diagnostic allowed accurate prediction of the optimal angle for further static angiographic series, which is of great value in transplant renal vessels.

Anastomosis, Surgical↗

Three-dimensional reconstructed rotational digital subtraction angiography in planning treatment of intracranial aneurysms.

We evaluated three-dimensional (3D) reconstructions of 200 degrees rotational digital subtraction angiography (DSA) images for their contributions to improving the safety of endovascular embolization of intracranial aneurysms. Standard DSA and 200 degrees rotational DSA were performed in 40 adult patients (aged 21-77 years) with 45 intracranial aneurysms. Information obtainable from standard DSA and 3D-DSA images about aneurysm shape and size was compared. In 40 (89%) of the 45 aneurysms 3D-DSA gave additional information about the anatomy of the aneurysm. In 17 (43 %) of these cases aneurysm anatomy could be visualized better on 3D-DSA than on standard DSA images. In three cases only 3D-DSA images showed blood vessels originating from the aneurysm. Reconstructed 3D images were also helpful in visualizing partially clipped aneurysms. On maximum-intensity projection images it was even possible to depict previously embolized aneurysms. Blood vessels originating from the aneurysm are visible on 3D-DSA images, and even previously clipped aneurysms can be visualized well. Rotational DSA with 3D reconstruction is a helpful tool in the assessment of intracranial aneurysms.

Adult↗

A comparison between ultrasonography and mammography, computed tomography and digital subtraction angiography for the detection of breast cancers.

Ultrasound (US) was compared with mammography (MMG), computed tomography (CT), and digital subtraction angiography (DSA) in its effectiveness to detect breast cancer masses and metastatic axillary nodes. Forty-seven breast cancer patients who all underwent MMG, US, CT, and DSA preoperatively in our institution between 1986 and 1990 were studied. US was able to detect tumors in all cases regardless of tumor size, whereas DSA detected T1-size tumors and MMG detected T2-size tumors in 40% and 64.7% of cases, respectively, being specifically inferior to US. It was found that MMG was least likely to detect papillotubular carcinoma, although microcalcification alone without a tumor mass on MMG improved detectability from 46.2% to 76.9%, according to the histological type. CT was found to be most sensitive to axillary node metastases (81.8%), followed by US (72.7%), but DSA was significantly unfavorable (42.9%). Thus, we concluded that US was superior to MMG, CT, and DSA for detecting breast cancer masses, but that CT was more advantageous than US, while DSA was of little value for evaluating axillary nodal status.

Adult↗

[Rotational digital subtraction angiography of carotid bifurcation stenosis].

PURPOSE: A prospective study was designed to evaluate, whether multiplanar imaging with rotational digital subtraction angiography (R-DSA) could improve assessment of carotid artery bifurcation stenosis. PATIENTS AND METHODS: 45 patients with suspected stenosis of the ICA were examined with DSA in standard projections (0 degree-(45 degrees)-90 degrees) and additional R-DSA of each ICA from 0-90 degrees in 10 degrees steps. We compared imaging quality and degree of stenosis as well as exposure of the patients to radiation and contrast media. RESULTS: 79/82 R-DSA (96%) were suitable for evaluation of stenosis, 58/82 (70%) matched the quality standard of single projection DSA. Specificity and sensitivity of the R-DSA to diagnose high grade ACI stenosis were 100% and 94%, respectively. 7/79 R-DSA revealed a higher and 3/79 a lower degree of stenosis than the corresponding DSA. Regarding the degree of stenosis there was no significant difference between the two modalities (p > 0.05), but R-DSA detected 4 stenoses greater than 60% that were estimated to be lower than 60% by DSA. Radiation dose for R-DSA was equivalent to one DSA run (170 cGycm2). The average amount of contrast media (25 ml) was slightly higher than for 2-3 single-projection DSA (19.8 ml). CONCLUSIONS: R-DSA provides high quality imaging of the carotid bifurcation with multiplanar projections facilitating exact grading of vessel stenosis. The number of cases (n = 2) is to small to judge the value of R-DSA as to (tandem-) stenosis of the distal ICA. Still, diagnostic value and low radiation exposure justify the use of R-DSA as additional series to standard protocols.

Adult↗