PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “MICROSCOPY, PHASE”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30Linked to original sources

A simplified mode of differential phase contrast Lorentz microscopy.

A simplified mode of differential phase contrast Lorentz microscopy for the study of magnetic domain structures in thin films is proposed and demonstrated. This mode employs a single annular detector in a scanning transmission electron microscope rather than the specialized split detectors that have been previously used. The resulting signal is sufficiently linear with magnetic field strength to allow quantitative data to be obtained on the domain configurations and the natures of the domain walls.

Cobalt↗

Phase-shifting interference microscopy applied to the analysis of cell behaviour.

The theory of phase-shifting interferometry is not new but it is only recently, with the advent of solid-state detector arrays and fast image processors, that it has become a practical imaging technique. In conjunction with transmission interference microscopy, phase-shifting presents a new way of introducing contrast into the images of transparent microscopic objects such as cultured cells. An earlier paper from our laboratory has emphasised the advantages of transmission interference microscopy over phase contrast or differential interference contrast microscopy for the computerised analysis of cell behaviour. Phase-shifting greatly improves the accuracy, long-term stability and range of application of this technique but it has not previously, to our knowledge, been combined with transmission interference microscopy for the study of cultured cells. The resulting image is especially well suited to quantitative analysis by computer since it is a direct representation of the distribution of non-aqueous cellular material in the specimen. The image is not degraded by uneven illumination; by heterogeneous sensitivity of the detector array; or by differential absorption of light in the optics or specimen. Our main purpose in developing the method is to obtain sequences of images of the motile behaviour of cells in culture for analysis by computer. This type of analysis is potentially a powerful tool for studying the motile responses of cells and the operation and control of their locomotory machinery. Not only can the method be used for studying cell translocation and the dynamics of intracellular movement of non-aqueous material, but it is now possible to study in detail the time course of growth in individual cultured cells.

Animals↗

Topographic and phase-contrast imaging in atomic force microscopy

Phase-contrast imaging in the tapping mode atomic force microscopy (AFM) is a powerful method in surface characterization. This method can provide fine details about rough surfaces, which are normally obscured in topographic imaging. To illustrate some of the capabilities of phase-contrast imaging, AFM studies of Pt/Ti/SiO2/Si and Pb(Zr0.52Ti0.48)O3 (PZT) films were carried out. Phase-contrast imaging revealed fine details of their microstructures, including grain boundaries, triple junctions and twinning, which could not be detected by topographic imaging. The studies showed that phase-contrast imaging is capable of providing superior information about surface characteristics when compared to the standard topographic imaging.

Journal Article↗

Sigma receptor antagonists inhibit human lens cell growth and induce pigmentation.

PURPOSE: The expression of the Sigma 1 receptor and the ability of receptor antagonists to inhibit growth and induce pigment formation were investigated in human lens epithelial cells. METHODS: Capsular bags were formed for experimental purposes by performing sham cataract operations on donor lenses. The resultant bags were cultured in Eagle's minimum essential medium (EMEM) alone or supplemented with the Sigma receptor antagonists rimcazole (3 microM) and BD1047 (10 microM). Cell growth was monitored by phase microscopy. Tyrosine incorporation was quantified by culturing in the presence of 14-C tyrosine for 24 hours. At the end of the culture period, some bags were fixed in 4% paraformaldehyde for electron microscopy, and others were plunged into liquid nitrogen for later immunoblot and PCR analyses. Protein levels of tyrosinase (TYR), tyrosinase-related protein 1 (TYRP1), and tyrosinase-related protein 2 (TYRP2) were quantified by Western blot analysis. The presence of pigment granules within epithelial cells were monitored by phase and electron microscopy techniques. RESULTS: The Sigma-1 receptor was expressed in native human lens cells and in cultured capsular bag cells. The Sigma receptor antagonists BD1047 and rimcazole inhibited lens cell growth and, surprisingly, lens cells accumulated pigment granules in the presence of the antagonists. The antagonists raised preexisting levels of TYR and TYRP1, whereas there was no change in TYRP2. CONCLUSIONS: The human lens normally expresses components of the melanin synthesis pathway, and this suggests a possible origin for the pigment granules that have been observed under certain conditions in the human lens. Exposure of lens cells to Sigma receptor antagonists leads to growth inhibition and pigment granule production.

Blotting, Western↗

Mitochondria optical parameters are dependent on their energy state: a new electrooptical effect?

The membrane potential of mitochondria determines, to a large extent, their functional state and the response to the changing conditions of the environment. A correlation was found between the changes in the optical characteristics of isolated mitochondria and the composition of the incubation medium, which determines the potential of the inner mitochondrial membrane. The measurements performed by the method of coherent phase microscopy made it possible to establish a linear dependence of the phase height on the value of the membrane potential and to calculate the electrooptical constant, K approximately equal to (3-4) x 10(-7) m/V.

Algorithms↗

Comparison of tissue-cultured bovine endothelial cells from aorta and saphenous vein.

Endothelial cells were harvested from bovine aorta and saphenous vein with collagenase and cultured in McCoy's 5a medium (modified GIBCO) supplemented with 10% fetal bovine serum. The cells were subcultured through 17 passages over 4 to 5 months. The growth properties in culture of the two cell types were compared. Morphological comparisons included phase microscopy and scanning and transmission electron microscopy. Comparisons with cultured aortic smooth-muscle cells were made using phase and scanning electron microscopy. No differences were found between cultured endothelial cells from aorta and saphenous vein. Differences in growth patterns in culture clearly distinguished both endothelial cell types from smooth-muscle cells. The presence of Weibel-Palade bodies identified the cells from both sources as endothelial.

Animals↗

Time lapse phase contrast video microscopy of directed migration of human microvascular endothelial cells on matrigel.

Migration of microvascular endothelial cells is an early and critical step in angiogenesis. Formation of branching and polygonal cellular aggregates by endothelial cells on matrigel has often been considered to be an in vitro model for angiogenesis, although formation of lumens has not always been confirmed. The dynamics of migration of living cells of a human dermal microvascular endothelial cell line (HMEC-1) on a reconstituted basement membrane matrix have been captured in real time using time lapse video microscopy. The cells exhibit periods of quiescence and directed rapid migration by formation of extensions towards a specific target cell. Cells repeatedly extend flexible protrusions from the cell body both within the plane of the matrix and out of the plane of the matrix into the incubation medium. Connections between protrusions and target cells are made frequently, but not all cells which start to form protrusions achieve connections with other cells. Some of these migrating cells which do not connect arrest before reaching the target, or arrest and retract to their origin. After formation of multicellular polygonal structures, the structures contract to form amorphous clusters of fused cells without visible effects on the underlying matrix. The study demonstrates that time lapse video microscopy is a simple but very useful approach to monitor the dynamics of movements which vary in speed and frequency during migration of living cells.

Basement Membrane↗

Solubility of Mo6S4.5I4.5 nanowires in common solvents: a sedimentation study.

Due to their ease of fabrication and monodisperse, metallic nature, molybdenum-sulfur-iodine nanowires are an interesting alternative to carbon nanotubes for some applications. However very little is known about the solubility of these materials. In this work we have investigated the solubility of Mo(6)S(4.5)I(4.5) nanowire soot in a range of common solvents by performing sedimentation studies and microscopic and spectroscopic characterization. A sedimentation equation was derived showing that the concentration of any insoluble dispersed phase decreases exponentially with time. We find that in all solvents, Mo(6)S(4.5)I(4.5) nanowire soot contains three phases, two of which are insoluble with one stable phase. Microscopy and spectroscopy show that the first insoluble phase is associated mainly with spherical impurities and sediments rapidly out of solution resulting in purification. The second phase appears to consist of insoluble nanowire bundles and sediments more slowly, eventually leaving a stable dispersion of nanowire bundles. The stably dispersed bundles tend to be smaller than their insoluble counterparts. The best solvents studied were 2-propanol and dimethylformamide. Microscopy studies showed that, in the case of 2-propanol, sonication significantly reduced the bundle size relative to the unsonicated bulk. However, during sedimentation, large quantities of bundles were observed to reaggregate to form larger bundles which subsequently sedimented out of solution. In general, the sedimentation properties of the various phases did not vary significantly with concentration indicating that the insoluble nanowires are intrinsically insoluble. However, the diameter of the stably dispersed bundles decreased with concentration, until very small bundles consisting of only two or three nanowires were observed at concentrations below 0.003 mg/mL. In addition, stable composite dispersions were produced by mixing the nanowires with poly(vinylpyrrolidone) in 2-propanol opening the way for the formation of polymer/inorganic nanowire composites.

Journal Article↗

A simple fluorescence labeling method to visualize the three-dimensional arrangement of collagen fibers in the equine periodontal ligament.

In order to display the collagen-fiber arrangement in the equine periodontal ligament an inexpensive and easy staining procedure with fluorescein was applied to paraffin sections. After fluorescein labeling a section was suitable for successful examination with three special microscopical systems: a) fluorescence microscopy b) phase contrast microscopy and c) polarized light microscopy. Collagen fibers were clearly displayed as compact structures in the fluorescence microscope. This distinct feature of the fluorescent image generated an almost three-dimensional impression of the fiber arrangement. Phase contrast microscopy and polarized light microscopical investigations of the same section supplemented the findings with further structural details. This contributed to demonstration of the complex architecture of the PDL, i. e. the varying sizes of the fiber bundles, their specific spatial alignment, and the entheses to the dental cementum.

Aging↗

Purely numerical compensation for microscope objective phase curvature in digital holographic microscopy: influence of digital phase mask position.

Introducing a microscope objective in an interferometric setup induces a phase curvature on the resulting wavefront. In digital holography, the compensation of this curvature is often done by introducing an identical curvature in the reference arm and the hologram is then processed using a plane wave in the reconstruction. This physical compensation can be avoided, and several numerical methods exist to retrieve phase contrast images in which the microscope curvature is compensated. Usually, a digital array of complex numbers is introduced in the reconstruction process to perform this curvature correction. Different corrections are discussed in terms of their influence on the reconstructed image size and location in space. The results are presented according to two different expressions of the Fresnel transform, the single Fourier transform and convolution approaches, used to propagate the reconstructed wavefront from the hologram plane to the final image plane.

Algorithms↗

Dentin-specific proteins in MDPC-23 cell line.

Only four established odontoblast-like cell lines have been reported in the literature (1-6). Of the four, only two synthesize dentin-specific proteins. These studies report that the cell line MO6-G3 synthesizes phosphophoryn (DPP), dentin sialoprotein (DSP) and dentin matrix protein-1 (DMP-1) while MDPC-23 synthesizes DSP, but not DMP-1. The objective of the present study was to determine whether polyclonal antibodies to rat DSP and DPP would label odontoblasts on microscopic sections of day-19 fetal mouse incisor odontoblasts as well as cultured cells of the MDPC-23 cell line. The spontaneously immortalized MDPC-23 cell line was derived from fetal mouse molar papillae, made continuous by the 3T6 method and cloned by dilution. These cultures have been passaged 77 times after cloning, form multilayered nodules, and have high alkaline phosphatase activity. The data show positive reactivity in odontoblasts in 19-d mouse fetal incisors as well as in cultures of MDPC-23 cells by fluorescence and confocal microscopy. In addition, these cultures were characterized by phase microscopy and scanning and transmission electron microscopy. These findings suggest that MDPC-23 cells are of the odontoblast lineage.

Animals↗

A dynamic phase microscopic study of optical characteristics of individual chloroplasts.

Dynamic phase microscopy (DPM) allows the monitoring of optical path difference (or phase height), h(x,y,t) approximately integraln(x,y,z,t)dz, an integral refractive index projection of the medium, n(x,y,z,t), in optically transparent biological specimens at high spatial and temporal resolutions. In this study, DPM was used for the analysis of fluctuations in the optical characteristics of individual bean chloroplasts in various metabolic states. A "phase image" of an individual chloroplast, which represents a three-dimensional plot of the "phase height", was obtained for the first time, and the frequency spectra of the fluctuations of h(x,y,t) were investigated. The fluctuation patterns, i.e., the intensity and the frequency spectra of phase height fluctuations in bean chloroplasts (Class B) were found to depend on their metabolic state. Under conditions of noncyclic (or pseudocyclic) electron transport, the fluctuations displayed characteristic frequencies in the range of 0.25-0.6 Hz and were space-time-correlated in the chloroplast domains with the cross sizes of approximately 2 microm. The fluctuation intensity decreased in the presence of uncouplers (nigericin and valinomycin, 20 microM). A stronger (in comparison with 20 microM valinomycin) effect of 20 microM nigericin suggests that the light-induced generation of the transmembrane pH difference (DeltapH) makes the main contribution to the increment of space-correlated fluctuations of h(x,y,t). Studies of chloroplasts incubated in media of various osmolarity (50-500 mM sucrose) have shown that structural changes in thylakoids are among other factors responsible for phase height fluctuations.

Chloroplasts↗

Optimizing phase contrast in transmission electron microscopy with an electrostatic (Boersch) phase plate.

Imaging of weak amplitude and phase objects, such as unstained vitrified biological samples, by conventional transmission electron microscopy (TEM) suffers from poor object contrast since the amplitude and phase of the scattered electron wave change only very little. In phase contrast light microscopy the imaging of weak phase objects is greatly enhanced by the use of a quarter-wave phase plate, which produces high signal contrast by shifting the phase of the scattered light. An analogous quarter-wave plate for the electron microscope, designed as an electrostatic einzel lens, was proposed by Boersch in 1947 but the small dimensions of the device have impeded its realization up to now. We here present the first fabrication and application of a miniaturized electrostatic einzel lens driven as TEM quarter-wave phase plate. Phase modulation is generated by the electrostatic field confined to the inside of a microstructured ring electrode. This field affects the phase velocity of the unscattered part of the electron wave. By varying its strength the phase shift of the primary beam can be adjusted to pi/2, producing strong phase contrast independent of spatial frequency. The phase plate proves to be mechanically stable and does not impair image quality, in particular it does not reduce the high-resolution signal. The expected residual lens effect of the einzel lens is minimal. Our microlens is supported by conducting rods arranged in a threefold symmetry. This particular geometry provides optimized single-sideband signal transfer for spatial frequencies otherwise obstructed by the supporting rods.

Journal Article↗