PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Solid Phase Microextraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30Linked to original sources

Analysis of methanol or formic acid in body fluids by headspace solid-phase microextraction and capillary gas chromatography.

Methanol and its metabolite formic acid have been found extractable from human whole blood and urine by headspace solid-phase microextraction (SPME) with a Carboxen/polydimethylsiloxane fiber. The headspace SPME for formic acid was carried out after derivatization to methyl formate under acidic conditions. The determinations of both compounds were made by using acetonitrile as internal standard (IS) and capillary gas chromatography (GC) with flame ionization detection. The headspace SPME-GC gave sharp peaks for methanol, methyl formate and I.S.; and low background noises for whole blood and urine samples. Extraction efficiencies were 0.25-1.05% of methanol and 0.38-0.84% formic acid for whole blood and urine. The calibration curves for methanol and formic acid showed excellent linearity in the range of 1.56 to 800 and 1.56 to 500 microg/0.5 ml of whole blood or urine, respectively. The detection limits were 0.1-0.5 microg/0.5 ml for methanol and 0.6 microg/0.5 ml for formic acid for both body fluids. The within-day relative standard deviations in terms of extraction efficiency for both compounds in whole blood and urine samples were not greater than 9.8%. By using the established SPME method, methanol and formic acid were successfully separated and determined in rat blood after oral administration of methanol.

Acetonitriles↗

Headspace solid-phase microextraction with 1-pyrenyldiazomethane on-fibre derivatisation for analysis of fluoroacetic acid in biological samples.

A new and in part automated headspace solid-phase microextraction method for quantitative determination of the highly toxic rodenticide fluoroacetic acid (FAA) in serum and other biological samples has been developed. FAA and deuterated acetic acid (internal standard) were extracted from acidified samples by a StableFlex divinylbenzene-Carboxen on polydimethylsiloxane fibre. The acids were derivatised on the fibre in-situ with 1-pyrenyldiazomethane and detected using gas chromatography-mass spectrometry with electron impact ionisation and selected ion monitoring. The calibration curve for FAA in serum was linear over the range from 0.02 to 5 microg/ml, with limits of detection and quantification of 0.02 and 0.07 microg/ml, respectively. The method was also tested with spiked whole blood, urine, stomach contents and kidney samples. It was sufficiently reliable, reproducible and sensitive for use in routine forensic toxicology applications.

Calibration↗

Determination of chlorophenols in soils using accelerated solvent extraction combined with solid-phase microextraction.

A method for the determination of chlorophenols in soil samples using accelerated solvent extraction (ASE) with water as the solvent combined with solid-phase microextraction (SPME) and GC/MS has been developed. Important ASE parameters, such as extraction temperature and time, were optimized using a spiked wetland soil. The effect of small amounts of organic modifiers on the extraction yields was studied. An extraction temperature of 125 degrees C and 10 min extractions performed three times proved optimal. Two ASE-SPME procedures without and with an organic modifier (5% acetonitrile) were evaluated with respect to precision and detection limits (LOD). The reproducibility of replicate water extractions/SPME determinations (n = 6) was in the range 7-20% relative standard deviation for the nine chlorophenols investigated. LOD values in the low-ppb range were achieved for all chlorophenols. The ASE-SPME procedure presented here was applied to the determination of chlorophenols in soil samples taken from contaminated areas near Bitterfeld, Germany.

Chlorophenols↗

Analysis of volatile compounds of taperebá (Spondias mombin L.) and cajá (Spondias mombin L.) by simultaneous distillation and extraction (SDE) and solid phase microextraction (SPME).

Volatile compounds of cajá and taperebá fruits, both classified as Spondias mombin, but from different geographic origins, were extracted (and analyzed) using solid phase microextraction (SPME) and simultaneous distillation and extraction (SDE). Forty-eight compounds were identified in taperebá and 47 in cajá by SPME using a DVB/CAR/PMDS fiber. (E)-Caryophyllene (18.7%), ethyl butyrate (10.0%), and ethyl hexanoate (7.0%) were the most abundant components in taperebá volatiles extracted by SPME, whereas myrcene (41.1%) and beta-phellandrene (8.5%) were the major compounds in cajá. In the taperebá SDE extract, 46 substances were identified, and (Z)-caryophyllene (13.2%) and limonene (9.5%) were predominant. From the 42 substances found in the SDE extract of cajá, the major components were myrcene (38.0%) and p-cymene (6.2%). The two fruits showed similar chromatograms upon the use of SDE and SPME. These methods made it possible to determine 30 identical components in both fruits by using SDE and 32 by using SPME.

Anacardiaceae↗

Comparison of mass spectrometry-based electronic nose and solid phase microextraction gas chromatography-mass spectrometry technique to assess infant formula oxidation.

Two headspace techniques based on mass spectrometry detection (MS), electronic nose, and solid phase microextraction coupled to gas chromatography-mass spectrometry (SPME-GC/MS) were evaluated for their ability to differentiate various infant formula powders based on changes of their volatiles upon storage. The electronic nose gave unresolved MS fingerprints of the samples gas phases that were further submitted to principal component analysis (PCA). Such direct MS recording combined to multivariate treatment enabled a rapid differentiation of the infant formulas over a 4 week storage test. Although MS-based electronic nose advantages are its easy-to-use aspect and its meaningful data interpretation obtained with a high throughput (100 samples per 24 h), its greatest disadvantage is that the present compounds could not be identified and quantified. For these reasons, a SPME-GC/MS measurement was also investigated. This technique allowed the identification of saturated aldehydes as the main volatiles present in the headspace of infant milk powders. An isotope dilution assay was further developed to quantitate hexanal as a potential indicator of infant milk powder oxidation. Thus, hexanal content was found to vary from roughly 500 and 3500 microg/kg for relatively non-oxidized and oxidized infant formulas, respectively.

Food Analysis↗

Effect of sample volume on quantitative analysis by solid-phase microextraction. Part 1. Theoretical considerations.

This paper discusses the effect of sample volume on the amount of analyte extracted from a sample by solid-phase microextraction (SPME) in two-phase (sample-fiber coating) and three-phase (sample-headspace-fiber coating) systems. Up-to-date knowledge is summarized, and new concepts are introduced. The effect of sample volume on quantification and precision of results can be neglected only in rare cases. The minimum sample volume which ensures that the amount extracted, n, is lower than 1% of the initial amount of the analyte present in the sample, as well as the volume for which exactly half of the initial amount of the analyte is extracted, have been calculated for both two- and three-phase systems. It is critical that the volumes of samples and standards are the same during analysis by SPME. Extraction kinetics in headspace analysis is dependent on the headspace capacity. If it is sufficiently large, the analyte is extracted almost exclusively from the gaseous phase, and equilibration can be very fast. On the other hand, this causes a significant loss of sensitivity. The effect of sample volume on the determination of the value of the partition coefficient, K, is also discussed. If the change in concentration of the analyte in the sample at equilibrium is not taken into account, erroneous results are obtained. Even when a proper procedure is used, there are practical limitations to the accuracy of the K value determination. Large sample volumes should always be used for K value determination, as they enable broader ranges of K values to be covered with good accuracy.

Chemical Phenomena↗

One step and highly sensitive headspace solid-phase microextraction sample preparation approach for the analysis of methamphetamine and amphetamine in human urine.

A fiber-stable, repeatable and highly sensitive headspace solid-phase microextraction (HS-SPME) method was developed for the analysis of methamphetamine (MA) and amphetamine (AM) in urine using gas chromatography-mass spectrometry (GC-MS) in the selected ion monitoring mode. For sample preparation, the test specimen was placed in a 7 ml vial along with the additives (KOH and NaCl) and the internal standards (d8-MA and d8-AM), a glass insert containing heptafluorobutyric anhydride (HFBA) and heptafluorobutyric chloride (HFBCl) as derivatizing reagents was inserted into the vial, the vial was then sealed tightly. A SPME device with a 100 microm polydimethylsiloxane fiber was inserted into the vial and the fiber was exposed to the headspace in the insert, then the vial was heated and stirred at 100 degrees C and 600 rpm for 20 min for evaporation/adsorption/derivatization. The vaporized analytes (AM and MA) in the vial diffused into the glass insert though the holes on the insert, they absorbed onto the fiber, and then interacted with the vapor of the derivatizing reagent. Some of the analytes in the headspace of the glass insert may react with the vapor of the derivatizing reagent first, and then adsorb onto the fiber. The needle was finally removed and inserted into the injection port to desorb the analytes with the fiber exposed to the liner of the GC-MS system for analysis. By combining HFBCl and HFBA as derivatizing reagents and placing them in an insert, the HS-SPME method achieves high sensitivity for the analysis of AM and MA. Correlation coefficients derived from typical calibration curves in the 1.0-1700 ng ml(-1) range are 0.998 for MA and 0.994 for AM. The limits of detection and the limits of quantitation using a sample size of 1 ml are 0.3 and 1.0 ng ml(-1), respectively, for both MA and AM in urine specimens. Because the water hydrolysis of derivatizing reagent is much faster than the acylation reaction of the primary and secondary amines with the derivatizing reagent, the amphetamines cannot be acylated effectively over heated aqueous solution, and therefore this study provides a new acylation design in moisture surroundings. The proposed process also simplifies the procedure for urine sample preparation, and makes the automation of SPME possible.

Amphetamine↗

Simple and sensitive analysis of nereistoxin and its metabolites in human serum using headspace solid-phase microextraction and gas chromatography-mass spectrometry.

A simple method for the analysis of nereistoxin and its metabolites in human serum using headspace solid-phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS) is developed. A vial containing a serum sample, 5M sodium hydroxide, and benzylacetone (internal standard) is heated to 70 degrees C, and an SPME fiber is exposed for 30 min in the headspace of the vial. The compounds extracted by the fiber are desorbed by exposing the fiber in the injection port of the GC-MS. The calibration curves show linearity in the range of 0.05-5.0 micrograms/mL for nereistoxin and N-methyl-N-(2-methylthio-1-methylthiomethyl)ethylamine, 0.01-5.0 micrograms/mL for S,S'-dimethyl dihydronereistoxin, and 0.5-10 micrograms/mL for 2-methylthio-1-methylthiomethylethylamine in serum. No interferences are found, and the analysis time is 50 min for one sample. In addition, this proposed method is applied to a patient who attempted suicide by ingesting Padan 4R, a herbicide. Padan 4R contains 4% cartap hydrochloride, which is an analogue of nereistoxin. Nereistoxin and its metabolites are detected in the serum samples collected from the patient during hospitalization. The concentration ranges of nereistoxin in the serum are 0.09-2.69 micrograms/mL.

Adult↗

Optimization of extraction conditions and fiber selection for semivolatile analytes using solid-phase microextraction

A group of 15 large volatile and semivolatile analytes (MW 92-499 amu) representing 13 organic classes are extracted with 9 different solid-phase microextraction fibers. The extraction efficiencies of the fibers for each of the analytes are compared. The influence of modifying the pH of the sample on the extraction efficiency of the fibers is shown. The effects of the size of the analytes with respect to fiber coating thickness and the relationship between fiber coating polarity and analyte polarity are discussed. In addition to fiber polarity and coating thickness, the different mechanisms by which the fibers extract are presented. A comparison of immersion and heated headspace extraction techniques for these analytes is shown.

Journal Article↗

Application of solid-phase microextraction to antidoping analysis: determination of stimulants, narcotics, and other classes of substances excreted free in urine.

This paper describes the application of solid-phase microextraction (SPME) with subsequent injection in a gas chromatograph-mass spectrometer (GC-MS) (electron impact, full scan) for the screening analysis of stimulants and narcotics in urine. Several different kinds of fibers were preliminarily tested and comparatively evaluated considering the influence on the overall analytical performance of the method; other experimental parameters; and, primarily among them, the volume of urine, the pH value, and the time of adsorbtion. The optimal experimental conditions have been recorded using 0.5 mL of urine with the pH value adjusted to 10 with carbonate buffer, and in which is immersed a polydimethylsiloxane/divinylbenzene fiber, with a sampling time of 30 min; the fiber is then directly desorbed in the injection port of the GC-MS equipment. All the analytes show a good linearity (R2 > 0.99 for most substances) and a good reproducibility at the concentration corresponding to the minimum performance requirement limit or at the cut-off value fixed by the World AntiDoping Agency (CV% < 11). The limit of detection of the method is 50 ng/mL for the majority of the substances investigated. Imidazole-based drugs (e.g., naphazoline) and local anesthetics can also be included in this screening method. Whenever necessary, confirmation analyses may also be performed by following the same pre-chromatographic procedure. Integrating the SPME process and the GC-MS analysis with a dedicated autosampler that combines the microextraction and injection capacities maximizes the overall analytical capacity of a single GC-MS system and reduces the human labor necessary for and the environmental impact of screening for stimulants and narcotics excreted free in urine.

Anesthetics, Local↗

Multiwalled carbon nanotubes coated fibers for solid-phase microextraction of polybrominated diphenyl ethers in water and milk samples before gas chromatography with electron-capture detection.

Determination of polybrominated diphenyl ethers (PBDEs) in environmental samples has raised great concerns due to the widespread use of PBDEs and their potential risk to humans. Solid-phase microextraction (SPME) is a fast, simple, cost-effective, and green sample preparation technique and is widely used for environmental analysis, but reports on the application of SPME for determination of PBDEs are very limited, and only a few publications dealing with commercial SPME fibers are available for extraction of PBDEs. Herein, we report a novel SPME method using multiwalled carbon nanotubes (MWCNTs) as the SPME fiber coating for gas chromatography with electron-capture detection (GC-ECD) of PBDEs in environmental samples. The MWCNTs coating gave much higher enhancement factors (616-1756) than poly (5% dibenzene-95% dimethylsiloxane) coating (139-384) and activated carbon coating (193-423). Thirty-minute extraction of 10 mL of sample solution using the MWCNTs coated fiber for GC-ECD determination yielded the limits of detection of 3.6-8.6 ng L(-1) and exhibited good linearity of the calibration functions (r(2)>0.995). The precision (RSD%, n=4) for peak area and retention time at the 500 ng L(-1) level was 6.9-8.8% and 0.6-0.9%, respectively. The developed method was successfully applied for the analysis of real samples including local river water, wastewater, and milk samples. The recovery of the PBDEs at 500 ng L(-1) spiked in these samples ranged from 90 to 119%. No PBDEs were detected in the river water and skimmed milk samples, whereas in the wastewater sample, 134-215 ng L(-1) of PBDEs were found. The PBDEs were detected in all whole fat milk samples, ranging from 13 to 484 ng L(-1). In a semiskimmed milk sample, only BDE-47 was found at 21 ng L(-1).

Animals↗

[Solid phase microextraction (SPME) of sample preparation during of a complex biological matrix in biotransformation studies].

Within the scope of the investigation of drug metabolism in keratinocytes solid phase microextraction (SPME) was investigated as a suitable method for sample preparation. The application of SPME is based on the fact, that a amount of analyte is absorbed by the polymer fiber at equilibrium, and the fiber is localized on a tip of a GC-syringe. The stable nitroxyl radical TEMPO (2,2,6,6-tetramthylpiperidine-1-oxyl) and its apolar metabolite 2,2,6,6-tetramethylpiperidine were analyzed by SPME and subsequent GC using thymol as internal standard. By means of the headspace-technique and an apolar fiber the recovery rate of TEMPO and the metabolite was nearly 100% and the precision was high. However, the results of the direct SPME were unsatisfactory. In comparison with conventional liquid/liquid extraction and solid phase extraction SPE the SPME proved the best results with regard to recovery rate and precision. Furthermore, the main advantages of SPME are the renunciation of organic solvents, the saving of time, the possibility to reuse the fiber about 100-150 times and the option for a complete automatisation of the extraction procedure.

Biotransformation↗

Determination of major aroma impact compounds in fermented cucumbers by solid-phase microextraction--gas chromatography--mass spectrometry--olfactometry detection.

Purge-and-trap, solid-phase extraction, and solid-phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS) sample preparation techniques for the analysis of odor impact chemicals in fermented cucumber brine are compared. SPME-GC-MS is coupled with detection frequency olfactometry experiments to determine key impact odor compounds in the brine. The most potent odorants that define the typical characteristic brine aroma are trans-4-hexenoic acid and cis-4-hexenoic acid. Confirmation of key impact odorants in brine is confirmed by recombination experiments.

Cucumis sativus↗

In-tube solid-phase microextraction sampler for long-term storage.

Capillary extractors are proposed as samplers-preconcentrators to overcome losses of volatile organic compounds found using "classical" solid-phase microextraction fiber-holder samplers. A set of equal-size extractors was used to extract in-tube an aqueous solution of benzene, toluene, ethylbenzene and xylenes (BTEX) at 146 ppb. After storage for 6-30 days at 0-4 degrees C (or -15 degrees C) GC analyses were carried out to study BTEX recovery. Results demonstrated that sample preservation was very good: recovery was higher than 98% after 6 days, and more than 95% after 30 days. Capillary extractors, due to their high performance in preserving sample integrity, represent a real breakthrough for on-site sampling of volatile compounds by solid-phase pre-concentration techniques.

Chromatography, Gas↗

Characterization of an urban landfill soil by using physicochemical analysis and solid phase microextraction (SPME)-GC/MS.

We have aimed at characterizing top soil samples taken in-situ from five different locations of the unregulated dumping site in Eskişehir/Turkey for a period of six months. The study is the first attempt in the city and in Turkey, regarding particularly the SPME (Solid Phase Microextraction Technique) analysis method utilized. A comprehensive research has been conducted to produce critical soil data to be used for indicating current risks as well as the urgency of rehabilitating the site and establishing a sanitary landfill in the site. Conventional physicochemical analytical methods and SPME technique were used to analyze the samples. Physicochemical analyses were performed for determining the pH, total dried matter, volatile matter, total nitrogen, phosphorus, macro elements and heavy metals. Meteorological data were also recorded for the same period. SPSS.10.0 statistical program was used to determine the correlation between meteorological data and physicochemical analysis results. Mean values were used in the correlation analyses. These data indicated that the air temperature and precipitation have significant effects on soil characteristics. SPME, coupled with GC/MS, was used to identify eighty six volatile and semi-volatile organic compounds contained in soil samples. The samples were extracted by headspace SPME with heating (DeltaHS-SPME). SPME analyses were conducted using a commercially available polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber having a film thickness of 65 microm (Supelco) as a capture medium. The experimentally optimized headspace sampling conditions were arranged (15 min. at 50 degrees C) before a 30 min. sampling period.

Cities↗

Applicability of solid-phase microextraction combined with gas chromatography atomic emission detection (GC-MIP AED) for the determination of butyltin compounds in sediment samples.

The performance of solid-phase microextraction (SPME) applied to the determination of butyltin compounds in sediment samples is systematically evaluated. Matrix effects and influence of blank signals on the detection limits of the method are studied in detail. The interval of linear response is also evaluated in order to assess the applicability of the method to sediments polluted with butyltin compounds over a large range of concentrations. Advantages and drawbacks of including an SPME step, instead of the classic liquid-liquid extraction of the derivatized analytes, in the determination of butyltin compounds in sediment samples are considered in terms of achieved detection limits and experimental effort. Analytes were extracted from the samples by sonication using glacial acetic acid. An aliquot of the centrifuged extract was placed on a vial where compounds were ethylated and concentrated on a PDMS fiber using the headspace mode. Determinations were carried out using GC-MIP AED.

Acetic Acid↗

Analysis of anatoxin-a using polyaniline as a sorbent in solid-phase microextraction coupled to gas chromatography-mass spectrometry.

A simple and sensitive method for determining anatoxin-a in aqueous samples was developed using solid-phase microextraction (SPME) and gas chromatography with mass spectrometry (GC-MS) detection. Three forms of polyaniline (PANI) films and a single form of polypyrrole (PPY) film were prepared and applied for SPME. The extraction properties of these films to anatoxin-a were examined and it was shown that leucoemeraldine form of PANI displayed a better selectivity to this compound. SPME conditions were optimized by selecting the appropriate extraction parameters, including type of coating (leucoemeraldine form of PANI at 32 microm thicknesses), salt concentration (10%, w/v), time of extraction (30 min) and stirring rate (1000 rpm). The calibration curve was linear in the range from 50 to 10,000 ng/ml, with the detection limit (S/N = 3) of 11.2 ng/ml. This method was successfully applied for the analysis of anatoxin-a in the cultured media of two species of cyanobacteria.

Aniline Compounds↗

Solid-phase microextraction with on-fiber silylation for simultaneous determinations of endocrine disrupting chemicals and steroid hormones by gas chromatography-mass spectrometry.

Based on solid-phase microextraction (SPME) and on-fiber silylation, a method for simultaneous determinations of exogenous endocrine disrupting chemicals (EDCs) and endogenous steroid hormones in environmental aqueous and biological samples by gas chromatography-mass spectrometry (GC-MS) was developed. The selected target compounds were: octylphenol (OP), technical grade nonylphenol (t-NP), diethylstilbestrol (DES), dehydroisoandrosterone (DEHA), estrone (E1), 17beta-estradiol (E2), testosterone (T) and pregnenolone (PREG). The optimization of operating conditions influencing the performances of SPME and derivatization were studied in detail. The average correlation coefficient of the calibration curves of the target compounds was 0.9968 and the linear ranges of most compounds spanned over three orders of magnitude. The LOD/(LOQ) values of the target compounds in river water and blood serum were in the range of 0.002-0.378/(0.008-1.261) microg L(-1) and 0.004-0.474/(0.013-1.579) microg L(-1), respectively, which were a bit higher than those in the pure water due to matrix effects. The developed method was applied to the determinations of target compounds in real samples. Exogenous OP, t-NP and DES were at 0.15, 4.67 and 0.02 microg L(-1) in river water and 3.21, 12.17 and 0.15 microg L(-1) in fish blood serum. Natural steroid hormones E1, E2 and T were at 0.18, 0.10 and 5.55 microg L(-1) in river water, and in female fish serum, E1, E2 and PREG were at 1.61, 1.08 and 4.58 microg L(-1), respectively. The proposed SPME method was compared with traditional SPE procedure and the results found using both methods were in the same order of magnitude and both are quite agreeable.

Animals↗