[Guidance of interventions in subintimal recanalization and fenestration of dissection membranes using a novel dual-lumen intravascular ultrasound catheter].

PURPOSE: To evaluate the feasibility and effectiveness of IVUS-guided puncture for gaining controlled target lumen reentry in subintimal recanalization of chronic iliac/femoral artery occlusions and in fenestration of aortic dissections. MATERIALS AND METHODS: Between 5/2004 and 12/2005 12 consecutive patients (7 male, 5 female; mean age 64.6 +/- 12.0 years) with chronic critical limb ischemia and ischemic complications of aortic dissection were treated using the Pioneer catheter. This 6.2-F dual-lumen catheter combines a 20-MHz IVUS transducer with a pre-shaped extendable, hollow 24-gauge nitinol needle. This coaxial needle allows real-time IVUS-guided puncture of the target lumen and after successful reentry a 0.014" guidewire may be advanced through the needle into the target lumen. 7 patients were treated for aortic dissection and 5 patients (with failed previous attempts at subintimal recanalization) for chronic arterial occlusion. Patients with aortic dissection (5 type A dissections, 2 type B dissections) had developed renal ischemia (n = 2), renal and mesenteric ischemia (n = 2), or low extremity ischemia (n = 3). Patients with chronic arterial occlusions (2 common iliac artery occlusions, 3 superficial femoral artery occlusions) experienced ischemic rest pain (n = 4), and a non-healing foot ulcer (n = 1). RESULTS: The technical success rate using the Pioneer catheter was 100%. The recanalization/fenestration time was 37 +/- 12 min. Procedure-related complications did not occur. In 10 cases a significant improvement of clinical symptoms was evident. One patient with aortic dissection and ischemic paraplegia required subsequent surgical intervention. One patient had persistent ischemic rest pain despite successful recanalization of a superficial femoral artery occlusion. CONCLUSION: The Pioneer catheter is a reliable device which may be helpful for achieving target lumen reentry in subintimal recanalization of chronic occlusions and in fenestration of aortic dissections.

Aged↗

[Dissection of the extracranial vertebral artery. Color duplex ultrasound findings and follow-up of 20 patients].

AIM: To assess the diagnostic potential of duplex color-flow imaging in the evaluation of extracranial vertebral artery dissection. In 15 of 20 patients (75%), the dissection was related to trauma. METHOD: Over the last six years, we evaluated 20 consecutive patients aged 18 to 59 years with 24 extracranial vertebral artery dissections (four occurring bilaterally). The examinations were performed with a color Doppler imaging system using a 7 MHz transducer. Angiography was done in 18 patients, confirming the diagnosis. RESULTS: In 15 patients, the diagnosis was primarily established with ultrasonography. Six vertebral arteries were dissected at the origin or in the proximal V1 segment, one in the distal V2 segment and one at the atlas loop. Most dissections occurred in the region between the V1 and V2 segments (n = 16), most often at the entrance of the artery into the transverse foramen of the C6 vertebra (n = 11). Typical ultrasonographic findings were irregular stenosis, dissecting membrane with true and false lumen, localized increase in diameter of the artery, pseudoaneurysm, intramural hematoma and tapering stenosis with distal occlusion. The diagnosis of dissection in the V3 segment was based on indirect signs such as high resistance flow pattern and decreased diastolic flow velocity. In follow-up examinations, marked resolution of pathological findings were found in 17 cases (70.8%). Two occlusions were completely recanalized. CONCLUSION: Duplex color-flow imaging is a valuable noninvasive method for early diagnosis of extracranial vertebral artery dissection and for follow-up examinations.

Adolescent↗

Diagnosis of aortic dissection: the value of transesophageal echocardiography.

Using the transesophageal approach the descending part of the aorta can be imaged by two-dimensional enchocardiography in cross sections comparable to computer tomograms. The value of combined transesophageal and transthoracic echocardiography was evaluated in 53 patients who were studied consecutively from 1983 to 1986 with symptoms of aortic dissection and compared with computed tomography, angiography, surgery and/or autopsy. In all patients the transthoracic aorta could be visualized and the dissection could be classified according to DeBakey: in 9 of 29 patients (34%) type I dissection, in 4 (14%) type II dissection and in 16 (55%) type III dissection was found. Operation was carried out because of acute symptoms in 11 of the 29 patients, and 3 additional patients died before operation. In 24 patients aortic dissection could be ruled out. A sensitivity of 97% for transthoracic and transesophageal echocardiography, of 80% for computed tomography and of 78% for angiography was calculated. The specificity for echocardiography was 100%, for computed tomography 100% and for angiography 95%. The positive predictive accuracy for echocardiography and computed tomography was 100% and 95% for angiography. The negative predictive accuracy for echocardiography was 96%, for computed tomography 77% and for angiography 79%. In no patient was an aortic dissection found by computed tomography or angiography which was not detected by echocardiography. In 1 patient with a large ectasia of the aorta ascendens aortic dissection was overlooked as retrospective analysis demonstrated. Signs of aortic insufficiency and pericardial effusion were detected.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

[I.v. DSA in the diagnosis and follow-up of thoracic aortic dissection].

Intravenous DSA was performed in 53 patients with suspected dissection of the thoracic aorta and in 13 patients following surgery for aortic dissection. In 36 patients, the suspected diagnosis could be excluded definitely and, in 14 cases out of 17, a dissection was correctly diagnosed. All 11 type B dissections were correctly diagnosed. Of six type A dissections, only three were adequately demonstrated by IV DSA. In type B dissections, IV DSA is reliable, but in type A dissection with massive aortic insufficiency or pericardial tamponade the findings are not reliable. In all 13 patients who had surgery for dissection, IV DSA proved suitable for showing the anastomosis and progress of the disease.

Aortic Dissection↗

Laryngeal recurrent nerve injury in surgery for benign thyroid diseases: effect of nerve dissection and impact of individual surgeon in more than 27,000 nerves at risk.

OBJECTIVE: To evaluate the effect of recurrent nerve dissection on the incidence of recurrent laryngeal nerve injury (RLNI) and to analyze the performance of individual surgeons. SUMMARY BACKGROUND DATA: Dissection of the recurrent nerve is mandatory in total thyroidectomy, but its relative merit in less extensive resections is not clear. The reported rates of RLNI differ widely; this may reflect a variation in the performance of individual surgeons. METHODS: The authors studied the incidence of RLNI in primary surgery for benign thyroid disease during three periods in a single center. In period 1 (1979-1990; 9,385 consecutive patients, 15,865 nerves at risk), the recurrent nerve was not exposed. In period 2 (1991-1998; 6,128 patients, 10,548 nerves at risk), dissection of the recurrent nerve was the standard procedure. Global outcome and individual performance in these two periods were compared and presented to the surgeons. The effect of this quality control procedure was tested in 1999 (period 3; 930 patients, 1,561 nerves at risk). RESULTS: Exposure of the recurrent nerve significantly reduced the global rate of postoperative and permanent RLNI. Some but not all surgeons improved their results by recurrent nerve dissection (e.g., permanent RLNI rates ranged from 0% to 1.1%). The documented significant differences in individual performances did not affect the outcome in period 3. The extent of nerve dissection was a source of variability; the rate of permanent RLNI averaged 0.9%, 0.3%, and 0.1% for surgeons who only localized, partially exposed, and completely dissected the recurrent nerve, respectively. CONCLUSIONS: Recurrent nerve dissection significantly reduces the risk of RLNI. Extensive dissection facilitates visual control of nerve integrity during resection and is therefore superior to a more limited exposure of the nerve. Quality control can improve the global outcome and identify the variability in individual performance. This cannot be eliminated by merely confronting surgeons with comparative data; hence, it is important to search for the underlying causes.

Adolescent↗

Upper neck (level II) dissection for N0 neck supraglottic carcinoma.

OBJECTIVES: Elective neck dissection for the N0 neck in head and neck surgery is still controversial. This prospective nonrandomized study of N0 supraglottic carcinoma was designed to find an appropriate method of neck management. STUDY DESIGN: Anatomical studies show that the first echelon of lymphatic drainage from the supraglottic larynx is toward the upper jugular nodes (level II). An upper neck dissection (UND) was applied and all the lymph nodes were sent for frozen section. If the subclinical metastasis was found, a modified neck dissection was performed. If the nodes harbored no foci of cancer, the patients were observed after surgery on the supraglottic lesions. METHODS: Patient records of 142 patients with supraglottic laryngeal cancer (T1-4N0M0) were reviewed, with special attention paid to neck recurrences and survival rates. The cases were treated between 1976 and 1990 and all were observed for at least 5 years after the operation or until the time of death. RESULTS: The UND specimens of 142 patients were negative for metastasis. The 5-year survival rate for this group after surgery was 80.8%, according to the life table analysis. Fifteen of the 142 patients (10.6%) had neck recurrences during the period of observation within 5 years. The recurrence rate of this series with limited dissection on the neck was comparable with those reported in the literature after neck dissection, either radical or modified. CONCLUSIONS: There is no need for a comprehensive neck dissection for N0 supraglottic laryngeal cancer. A selective neck dissection such as UND (level II) or a supraomohyoid neck dissection (sparing the submandibular region) of level II and III will serve the purpose of radical neck treatment for the supraglottic cancer.

Adult↗

Water-jet dissection in parotid surgery: an experimental study in dogs.

OBJECTIVE: The objective of the present study was to investigate the application of the water-jet dissection method in parotid surgery by way of animal experiments, paying particular attention to the clinical and histological reactions of the facial nerve. STUDY DESIGN: An animal experimental study. METHODS: Total bilateral parotidectomies with retention of the facial nerve were performed on 19 beagle dogs by means of the Hydro-Jet device (Andreas Pein Medizintechnik Company, Schwerin, Germany) using different jet diameters and operating pressures. All operations were performed with continuous intraoperative facial monitoring (Neurosign 100, Inomed Company, Teningen, Germany). The dogs were monitored postoperatively over an average period of 20.3 days (range, 14-35 d). Local findings and facial nerve status were documented daily. In a second phase, the dissected nerves were resected and the animals were killed. Samples of water-jet-dissected parotid tissue, as well as all dissected nerve branches, underwent histological examination and were compared with clinical and electrophysiological findings. RESULTS: It was possible to perform operations easily on all parotid glands by means of the Hydro-Jet using the small, 120-microm jet at operating pressures of 40 to 60 bar and to dissect the facial nerve quickly and safely with retention of its functional capability (n = 34). The dissection of nerves using larger-diameter jets (150 and 200 microm [n = 64]) resulted in a total of two reversible and seven irreversible partial pareses. CONCLUSIONS: The study has shown that it is possible to perform tissue-selective operations on the parotid gland by means of the Hydro-Jet using the 120-microm jet at operating pressures of 40 to 60 bar, ensuring safe, atraumatic dissection of the facial nerve with retention of its functional capability. The advantages of the new Hydro-Jet method offer a valuable alternative compared with the normal dissection methods adopted in parotid surgery. Thus the results of the present investigation currently are being checked within the framework of a clinical study at our clinic.

Animals↗

Subarachnoid hemorrhage from vertebrobasilar dissecting aneurysm treated with staged bilateral vertebral artery occlusion: the importance of early follow-up angiography: technical case report.

OBJECTIVE AND IMPORTANCE: Vertebrobasilar dissecting aneurysms are an uncommon but increasingly recognized cause of subarachnoid hemorrhage (SAH). We describe a patient with SAH caused by a dissecting aneurysm involving both vertebral arteries as well as the basilar trunk. The patient was treated successfully with proximal occlusion of the vertebral arteries using endovascular balloon occlusion in two stages. The importance of early follow-up angiography to document progression or resolution of untreated dissections is emphasized. This approach is suggested as definitive treatment for vertebrobasilar dissection in appropriate circumstances. CLINICAL PRESENTATION: A 41-year-old man presented with SAH from spontaneous vertebrobasilar dissection. Angiography revealed aneurysmal dilation of the right vertebral artery and basilar trunk and occlusion of the left vertebral artery. INTERVENTION: The dissecting aneurysm was treated with balloon occlusion of the right vertebral artery. Repeat angiography 2 weeks later demonstrated resolution of the left vertebral occlusion, with restoration of antegrade flow in the basilar trunk and increased filling of the right vertebral and basilar dissecting aneurysms. Balloon occlusion of the left vertebral artery led to aneurysm thrombosis and excellent clinical outcome. CONCLUSION: Bilateral vertebrobasilar dissecting aneurysms are an uncommon cause of SAH. If unilateral proximal vertebral artery occlusion is chosen as the initial treatment, it is essential to document the status of the contralateral vessel using follow-up angiography. Staged bilateral vertebral artery occlusion should be considered in the event of recurrent or progressive aneurysm enlargement. Endovascular balloon occlusion has advantages over proximal clipping of the parent vessel: cranial nerve manipulation is avoided, test occlusion in the awake patient can be performed at the site of permanent occlusion, and therapeutic levels of anticoagulation can be maintained throughout and after the procedure, thus diminishing the likelihood of thromboembolic complications.

Adult↗

Fiber dissection technique: lateral aspect of the brain.

OBJECTIVE: The fiber dissection technique involves peeling away the white matter tracts of the brain to display its three-dimensional anatomic organization. Early anatomists demonstrated many tracts and fasciculi of the brain using this technique. The complexities of the preparation of the brain and the execution of fiber dissection have led to the neglect of this method, particularly since the development of the microtome and histological techniques. Nevertheless, the fiber dissection technique is a very relevant and reliable method for neurosurgeons to study the details of brain anatomic features. METHODS: Twenty previously frozen, formalin-fixed human brains were dissected from the lateral surface to the medial surface, using the operating microscope. Each stage of the process is described. The primary dissection tools were handmade, thin, wooden spatulas with tips of various sizes. RESULTS: We exposed and studied the myelinated fiber bundles of the brain and acquired a comprehensive understanding of their configurations and locations. CONCLUSION: The complex structures of the brain can be more clearly defined and understood when the fiber dissection technique is used. This knowledge can be incorporated into the preoperative planning process and applied to surgical strategies. Fiber dissection is time-consuming and complex, but it greatly adds to our knowledge of brain anatomic features and thus helps improve the quality of microneurosurgery. Because other anatomic techniques fail to provide a true understanding of the complex internal structures of the brain, the reestablishment of fiber dissection of white matter as a standard study method is recommended.

Brain↗

Acute dissecting aortic aneurysm: community hospital experience in 20 cases.

Of 20 patients with dissecting aortic aneurysm managed at our community hospital, 16 had type A (ascending) dissection and four had type B (descending) dissection. Twelve of the patients with type A dissection were operated on; six of them survived and six died postoperatively. The remaining four patients with type A dissection had cardiopulmonary arrest and died before surgical intervention was attempted. All four patients with type B dissection were treated medically and all survived. Although acute aortic dissection is not commonly seen at community hospitals, expedient management of such patients can have a major impact on their survival. Patients at extreme risk are those with type A dissection, particularly those with cardiopulmonary arrest.

Acute Disease↗

Problems encountered during and after stent-graft treatment of aortic dissection.

PURPOSE: The authors report their experiences with the problems encountered during and after stent-graft placement in patients with aortic dissections. MATERIALS AND METHODS: Between July 1994 and December 2003, stent-graft placement was performed in 60 patients with aortic dissections, 9 patients with Stanford type A dissection and 51 patients with type B. Ten patients had acute dissection and 50 patients had chronic dissection. Each patient was followed for 12 to 107 months (mean, 33 mo). All cases were retrospectively reviewed for any problem that occurred during and after the procedure. RESULTS: During the procedure, there were two cases (3%) of stent-graft migration, one case (2%) of stent-graft torsion, two cases (3%) of stent-graft folding due to oversizing, three cases (5%) of persistent thoracic false lumen flow by the appearance of a hidden intimal tear, one case (2%) of new intimal tear that resulted in retrograde type A dissection, and 12 cases (20%) of type I endoleaks on aortograms taken immediately after the procedure. During the follow-up period, one case (2%) of transient cerebral ischemia, six cases (10%) of persistent type I endoleaks, two cases (3%) of type II endoleaks through the intercostal artery, four cases (7%) with progressive dilatation of abdominal false lumen, six cases (10%) of new intimal tears which resulted in saccular aneurysms (n=4) or new dissections (n=2) on either or both ends of the stent-graft, and two cases (3%) of mechanical failure were observed. Overall, five patients (8%) required surgical conversion, and there were no cases of procedure-related mortality. CONCLUSION: Various problems can occur during and after stent-graft placement in aortic dissection. The thorough evaluation of preoperative imaging and close follow-up are mandatory to optimize the management of such problems.

Adult↗

Second radical neck dissection.

We report a series of 96 patients (62 men and 34 women) undergoing a second radical neck dissection for enlarged contralateral cervical nodes after primary treatment of a squamous cell carcinoma of the head and neck, including an ipsilateral radical neck dissection. The proportion of patients requiring a second later neck dissection varied from 0% for tumours of the nasopharynx, nasal cavity and paranasal sinuses, to 5% for tumours of the hypopharynx. The incidence of second neck dissection was not determined by the original T stage of the primary tumour, but patients with enlarged nodes at presentation were 5 times more likely to need a second neck dissection than those with no palpable nodes at presentation. Also, patients with a poorly differentiated tumour were twice as likely to need a second neck dissection as those with a well differentiated tumour. The overall 5-year survival after second neck dissection was 35% and the perioperative mortality 1.92%. Significant factors predicting survival after a second neck dissection were the time to recurrence, the clinical neck node status at recurrence, the number of histologically invaded nodes in the neck and the presence of extra-nodal disease.

Carcinoma, Squamous Cell↗

Use of computed tomographic scanning and aortography in the diagnosis of acute dissection of the thoracic aorta.

Before the introduction of computed tomographic (CT) scanning, aortography was the investigation of choice for acute aortic dissection. Between 1978 and 1982, 24 patients were referred to the Brompton Hospital with suspected acute thoracic aortic dissection; all had aortography with diagnosis confirmed at surgery (n = 12) or necropsy (n = 2) or supported by clinical outcome (n = 8). One patient in whom aortography was negative had type B dissection at necropsy and another patient was lost to follow up. CT scanning became available in this unit in 1983 and between 1983 and 1987 was used as the only imaging investigation in 32 patients with suspected acute dissection of the thoracic aorta while in a further 22 patients aortography was used alone. Results were confirmed at surgery (n = 18), necropsy (n = 3), or supported by clinical outcome (n = 31). Two patients were lost to follow up. In an additional 16 patients both aortography and CT scanning were performed with concordant findings in 10. In six in whom the results were discordant, aortography was normal in three in whom subsequent CT scanning showed type B dissection and CT scanning was normal in three patients in whom aortography showed type A dissection. Both CT scanning and aortography are reliable techniques for assessment of suspected acute dissection of the thoracic aorta. Both techniques misdiagnose occasionally and the frequency of misdiagnosis will be minimised by performing both investigations in patients where the level of clinical suspicion is high and the initial investigation negative. CT scanning tends to miss type A dissection and in view of the success of surgery in this condition this failing has the more serious clinical consequences.

Adult↗

Aortic dissection: atypical patterns seen at MR imaging.

Aortic dissection is typically manifested by an intimal flap separating true and false lumens. Atypical patterns lacking an intimal flap can occur, however, and are less well recognized. In this study, the authors review their experience with atypical patterns at magnetic resonance (MR) imaging. They evaluated the T1-weighted and gradient-echo MR images of the entire aorta in 64 patients with aortic dissection. In nine patients (14%) aortic wall thickening was the only sign of dissection in the thorax. In three of these cases, an intimal flap was found in the abdominal aorta; the other six patients had no flap in any region of the aorta, and this led to false-negative angiographic results in three cases. Aortic wall thickening as an atypical sign of dissection was seen more frequently in acute (29%) than in chronic (7%) dissection and was seen in only patients without Marfan syndrome. Two patients with atypical acute dissection at initial examination developed a clearly identifiable intimal flap at follow-up. Aortic wall thickening may represent the only sign of aortic dissection. In some cases, imaging the entire aorta can enable recognition of dissection in atypical cases.

Acute Disease↗

Cat dissection vs. sculpting human structures in clay: an analysis of two approaches to undergraduate human anatomy laboratory education.

Many human anatomy courses are taught using cat dissection. Alternatives are available, but information regarding learning outcomes is incomplete. In 2003, approximately 120 undergraduates enrolled in a human anatomy course were assigned to one of two treatment groups. In the control group, students performed cat dissections (emphasizing isolation and identification) of the muscular, digestive, and cardiovascular systems. In the experimental treatment group, students built clay sculptures of each human body system. Student learning was evaluated by using both low- and high-difficulty questions. On pre- and postexperiment control exams, there were no significant differences in student performance. On exams after a cat dissection vs. a human-clay sculpting experience, the students in the human-clay sculpting treatment group scored significantly higher than their classmates in the cat dissection group on both the low- and high-difficulty questions. Student attitudes toward dissection and taking future human anatomy courses were also measured. There were no differences in student attitudes at the beginning of the experiment; afterward, students exposed to a cat dissection experience viewed dissection more favorably than students in the human-clay sculpting treatment group. There were no treatment effects on student willingness to take future human anatomy courses. The experimental design makes it difficult to conclude precisely why students assigned to the human-clay sculpting experience performed better on exams, but as each method was performed in this particular human anatomy course, our data indicate that human-clay sculpting may be a viable alternative to cat dissection in an anatomy course in which the students focus on human anatomy.

Animals↗

Diagnosis of thoracic aortic dissection. Magnetic resonance imaging versus transesophageal echocardiography.

BACKGROUND: Aortic dissection requires prompt and reliable diagnosis to reduce the high mortality. The purpose of this study was to assess the reliability of both ECG-triggered magnetic resonance imaging (MRI) and transesophageal two-dimensional echocardiography combined with color-coded Doppler flow imaging (TEE) for the diagnosis of thoracic aortic dissection and associated epiphenomena. METHODS AND RESULTS: Fifty-three consecutive patients with clinically suspected aortic dissection were subjected to a dual noninvasive imaging protocol in random order; imaging results were compared and validated against the independent morphological "gold standard" of intraoperative findings (n = 27), necropsy (n = 7), and/or contrast angiography (n = 53). No serious side effects were encountered with either imaging method. In contrast to a precursory screening transthoracic echogram, the sensitivities of both MRI and TEE were 100% for detecting a dissection of the thoracic aorta irrespective of its location. The specificity of TEE, however, was lower than the specificity of MRI for a dissection (TEE, 68.2% versus MRI, 100%; p less than 0.005), which resulted mainly from false-positive TEE findings confined to the ascending segment of the aorta (TEE, 78.8% versus MRI, 100%; p less than 0.01). In addition, MRI proved to be more sensitive than TEE in detecting the formation of thrombus in the false lumen of both the aortic arch (p less than 0.01) and the descending segment of the aorta (p less than 0.05). There were no discrepancies between the two imaging techniques in detecting the site of entry to a dissection, aortic regurgitation, or pericardial effusion. CONCLUSIONS: Both MRI and TEE are atraumatic, safe, and highly sensitive methods to identify and classify acute and subacute dissections of the entire thoracic aorta. TEE, however, is associated with lower specificity for lesions in the ascending aorta. These results may still favor TEE as a semi-invasive diagnostic procedure after a precursory screening transthoracic echogram in suspected aortic dissection, but they establish MRI as an excellent method to avoid false-positive findings. Anatomic mapping by MRI may emerge as the most comprehensive approach and morphological standard to guide surgical interventions.

Adult↗

Aortic root dilatation in patients with spontaneous cervical artery dissection.

BACKGROUND: Spontaneous cervical artery dissections are a relatively common cause of ischemic stroke in young adults. Their mechanism is unknown, though it is generally assumed that an underlying minor form of extracellular matrix defect could exist. The present study tested the hypothesis that aortic and cardiac morphological abnormalities usually seen in patients with heritable connective diseases are more frequent in patients with spontaneous cervical artery dissections than in patients without such dissections. METHODS AND RESULTS: We performed a case-control study of 28 case patients with spontaneous cervical artery dissection and 84 control subjects with an ischemic stroke not due to cervical artery dissection. Control subjects were matched to case patients for age (+/-5 years), sex, and year of hospitalization. The aortic root was more frequently enlarged (ie, diameter > 34 mm) in case patients (56%) than in control subjects (15%). Mitral valve prolapse, mitral valve dystrophy, and aortic valve dystrophy were more frequent in case patients than in control subjects. In multivariate analyses, aortic diameter > 34 mm was the only variable associated with an increased risk of spontaneous cervical artery dissection (odds ratio, 14.2; 95% CI, 3.2 to 63.6; P < .001). CONCLUSIONS: These results suggest that aortic root diameter enlargement is associated with an increased risk of spontaneous cervical artery dissection. This finding is consistent with the idea that a generalized defect of the extracellular matrix is present in patients with spontaneous cervical artery dissection.

Adult↗

Progressive symptomatic carotid dissection treated with multiple stents.

BACKGROUND AND PURPOSE: Internal carotid artery (ICA) dissection remains a major cause of stroke in the young. Although systemic anticoagulation and antiplatelet therapy allow healing of the dissection in most patients, medical treatment can fail or be contraindicated. In selected cases of carotid dissections, the use of endovascular stent-assisted angioplasty has been reported to permit reconstruction of the extracranial ICA. METHODS: We report a case of symptomatic spontaneous carotid dissection which progressively extended from the cervical to the supraclinoid segments of the ICA in a 48-year-old patient under anticoagulant therapy. Because of failed medical therapy and further transient ischemic attacks (TIAs), the patient was treated by 5 tandem stents deployed in an overlapping fashion from the terminal ICA to the cervical segment. RESULTS: Postprocedure angiography demonstrated reconstitution of the luminal diameter of the ICA. The patient progressively improved and no further TIAs were observed. At 8-month follow-up, the vessel remained patent with a slight intra-extracranial reduction in size suggesting myointimal hyperplasia. Neurological exam was normal. CONCLUSIONS: The successful angiographic and clinical results observed in our case of intra-extracranial stenting of a long dissection contributes to the literature of carotid dissection treated with multiple stents. The excellent mid-term follow-up in our patient confirms the efficacy of this treatment and good tolerance to multiple stents. To our knowledge this is the first case of spontaneous dissection treated with stenting including the distal supraclinoid segment, through an extensive proximally dissected artery.

Angiography↗