PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “ELECTROPHORESIS”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31Linked to original sources

Complete separation of anti-hapten antibodies by two-dimensional affinity electrophoresis.

A high resolution two-dimensional affinity electrophoresis has been developed, using capillary isoelectric focusing as the first electrophoresis and slab gel affinity electrophoresis as second electrophoresis. By this method 1-2 micrograms of anti-dinitrophenyl antibodies have been separated completely into several hundred homogeneous IgG spots. They are grouped into a number of families which are composed of several IgG spots of the same affinity to the hapten but of a different pI. It is suggested that each individual family is derived from one monoclonal antibody producing cell line.

Animals↗

Applications of capillary electrophoresis for industrial analysis.

Capillary electrophoresis techniques, particularly isotachophoresis and zone electrophoresis, are useful for the determination of various analytes in a wide range of sample matrices. This paper reports applications of capillary electrophoresis developed for detergent, food additive, herbicide, animal nutrition and biotechnology samples. Major advantages of capillary electrophoresis include versatility and speed of method development. Options for small ion analysis using modern, fused silica capillary instruments are discussed.

Chemistry, Inorganic↗

The development of recycle zone electrophoresis.

Milan Bier's contributions to preparative electrophoresis and, in particular, his work in "recycling", have had an enormous impact on the development of scaling strategies for continuous flow electrophoresis. This paper reviews my early work on the theory of recycle applied to zone electrophoresis and reports the results of several recent experiments in which proteins were purified from complex feed mixtures using recycle zone electrophoresis.

Antibodies, Monoclonal↗

Biomedical and clinical applications of automated single cell electrophoresis.

The automated single cell electrophoresis microscope Parmoquant has been used for the discrimination of lymphocytes and the study of the interaction of substances with cells and synthetic particles. Electrophoretic histograms allowed the determination of changes in the proportion of lymphocyte populations after kidney transplantation, during dialysis treatment, open heart surgery and during pregnancy. Discrimination of leukemic cells on the basis of electrophoresis was used as an additional parameter in diagnosis. In a mouse tumor model, histogram determination enabled the in vivo effect of the tumor necrosis factor on immune cells to be evaluated. Cell electrophoresis was shown to be suitable to detect the influence of antibodies, lectins and bacteria on the cell surface. Protein adsorption was studied on synthetic particles using cell electrophoresis. This method was applied to investigate the phenomena of blood interaction with biomaterials used in artificial organs and to determine differences in the protein composition of serum or other body fluids connected with diseases.

Animals↗

Barley cultivar discrimination: I. Sodium dodecyl sulfate-polyacrylamide gel electrophoresis and glycoprotein blotting.

Two different methods of detecting electroblotted glycoproteins after sodium dodecyl sulfate-polyacrylamide gel electrophoresis of Tris-buffer soluble barley seed proteins were examined for their applicability for barley cultivar discrimination. These are the highly specific, lectin-based concanavalin A/peroxidase method and the more general periodate/danyslhydrazine method. The results of the periodate/dansylhydrazine method enabled us to divide the 20 examined cultivars into three groups, whereas the more sensitive concanavalin A/peroxidase method revealed six different glycoprotein patterns. In comparison, sodium dodecyl sulfate-polyacrylamide gel electrophoresis and silver staining of the alcohol-soluble barley seed proteins (hordeins) gave nine different banding patterns. A combination of hordein electrophoresis together with glycoprotein staining by the concanavalin A/peroxidase method made it possible to classify the cultivars into twelve groups, the largest of which contained four cultivars. The qualitative expression of the glycoprotein patterns seemed to be independent of growth conditions, whereas the band intensities obviously were not. As a whole, glycoprotein blotting is a valuable supplement to sodium dodecyl sulfate-polyacrylamide gel electrophoresis of hordeins in barley cultivar discrimination.

Concanavalin A↗

Native polyacrylamide gel electrophoresis of membrane proteins: glutaminase detection after in situ specific activity staining.

A new procedure for the analysis and detection of phosphate-activated glutaminase (EC 3.5.1.2) by native electrophoresis has been developed. The method is based on the in situ detection of glutaminase activity in two different systems of native polyacrylamide gradient gels, containing 3-(3-cholamidopropyl)-dimethyl-ammonio-1-propane sulfonate (CHAPS) or Triton X-100 as nondenaturant detergents. Crude Triton X-100 extracts of mitochondria were resolved by electrophoresis. The enzyme was specifically revealed by incubation of the gel with glutamine and coupling the oxidation of the glutamate formed to the reduction of a tetrazolium dye, in the presence of glutamate dehydrogenase trapped in a 1% agar solid overlay. Both Ehrlich ascitic cell and mouse kidney glutaminases were resolved by native electrophoresis and specifically detected with the activity staining. Moreover, the redox-cycling staining was tested in solution, showing linearity with the amount of glutamate or glutaminase activity present. The method described could be a useful tool for native polyacrylamide gel electrophoresis of membrane proteins.

Animals↗

Detection of a single base mismatch in double-stranded DNA by electrophoresis on uncrosslinked polyacrylamide gel.

Uncrosslinked polyacrylamide forms gels in the concentration range of 15-40% acrylamide. Electrophoresis in these gels of a commercially available 350 bp heteroduplex DNA preparation separates it from the homoduplex DNA of the same size. The separation is qualitatively equivalent to that previously achieved in a commercial proprietary gel ("Mutation Detection Gel" of AT-Biochem), or in an equivalent 14% T, 0.15% C (N,N'-methylenebisacrylamide) gel, but the mechanical stability of mutation detection electrophoresis (MDE) gels or 0.15% C gels is better than that of uncrosslinked polyacrylamide gels. The separation in any of these three gel media can be carried out in short gel tubes within a few hours of electrophoresis time. In both uncrosslinked polyacrylamide and MDE gel media, the Ferguson plots [log(mobility) vs. gel concentration] and the plots of effective molecular radius vs. gel concentration ("T-plots") of both the heteroduplex and homoduplex DNA indicate an augmented size but similar flexibility upon passage through the gel than exhibited by the components of a DNA standard ladder. Homoduplex and heteroduplex DNA correspondingly exhibit a parallelism of their Ferguson curves in transverse MDE pore gradient gel electrophoresis, suggesting a surface net charge difference, possibly due to a conformational reorientation too subtle to be detected by a shift in the slope of the Ferguson plot, as has been observed once previously with a "kinked" DNA species. The gel fiber radius or length per unit volume of uncrosslinked polyacrylamide and MDE gels do not differ significantly within confidence limits, which are wide compared to unconventionally crosslinked gels, presumably because of their greater swelling.

Acrylic Resins↗

A transient entanglement coupling mechanism for DNA separation by capillary electrophoresis in ultradilute polymer solutions.

Using capillary electrophoresis, large DNA molecules (2.0-23.1 kbp) may be rapidly separated in ultradilute polymer solutions (< 0.002% w/w) under a high-voltage, steady field (265 V/cm). At this polymer concentration, the separation mechanism appears to be significantly different from that postulated to occur in crosslinked gels. Based on experimental results obtained with DNA restriction fragments and with negatively charged latex microspheres, we conclude that the Ogston and reptation models typically used to describe gel electrophoresis are not appropriate for DNA separations in such dilute polymer solutions. Electrophoresis experiments employing solutions of both small and large hydroxyethyl cellulose polymers highlight the importance of polymer length and concentration for the optimum resolution of DNA fragments varying in size from 72 bp to 23.1 kbp. A transient entanglement coupling mechanism for DNA separation in dilute polymer solutions is developed, which suggests that there is no a priori upper size limit to DNA that can be separated by capillary electrophoresis in a constant field.

Cellulose↗

Commercial automated gel electrophoresis apparatus: application to DNA, band dispersion, nonlinear Ferguson curves, and isolation.

Recently available commercial automated gel electrophoresis apparatus with intermittent scanning of fluorescently labeled gel patterns (the HPGE-1000 apparatus of LabIntelligence, Menlo Park CA) was tested with regard to (i) its applicability to DNA in its native conformation, (ii) its ability to recognize the correct number of components, (iii) its capability to evaluate the width and shape of bands detected during electrophoresis, (iv) its ability to yield nonlinear Ferguson plots in a labor-saving fashion, and (v) its preparative potential. Ethidium homodimer (EtD) DNA (bp) ratios were systematically varied and the mobility of DNA fragments labeled at each ratio was measured in order to find a ratio which provided an unaltered mobility and presumably therefore an unaltered conformation of the fragment. That ratio was found to be 1/40 EtD/DNA (bp) or less. With such weak labeling of DNA, a representative fragment of 527 bp length requires a minimum load of 200 ng and a 2 micrograms load for a full-scale peak height. Using the baseline automatically selected by the software of the apparatus, the band areas of the 17 components of a DNA digest were consistently evaluated by the software, as evidenced by the proportionality between DNA length and area. The areas of the separated bands of DNA fragments of 1857 and 121 bp length were found to be constant with time of electrophoresis. The dispersion coefficient was found to decrease with agarose concentration in electrophoresis at 1 V/cm; however, at higher field strength, the band width of the 1857 bp fragment was surprisingly found to increase with gel concentration, presumably due to stretching.(ABSTRACT TRUNCATED AT 250 WORDS)

Buffers↗

Capillary electrophoresis of carboxylated carbohydrates. Part 2. Selective precolumn derivatization of sialooligosaccharides derived from gangliosides with 7-aminonaphthalene-1,3-disulfonic acid fluorescing tag.

The most suitable conditions for selective precolumn derivatization of sialooligosaccharides, derived from gangliosides, with 7-aminonaphthalene-1,3-disulfonic acid (ANDSA) and the subsequent separation of the derivatives by capillary electrophoresis are described. ANDSA-sialooligosaccharide derivatives, which fluoresce at 420 nm when excited at 315 nm, were readily detected in capillary electrophoresis using an on-column lamp-operated fluorescence detector. In addition, the precolumn derivatization described here, which exploited the reactivity of the carboxylic acid group of the sialic acid residue of the oligosaccharides, replaced each weak carboxylic acid group of the parent sugar by two strong sulfonic acid groups. This allowed for electrophoresis over a wide range of pH and improved the resolution of the derivatives when compared to those obtained with underivatized sialooligosaccharides under identical separation conditions. The separation of sialooligosaccharides was best achieved when 75 mM borate, pH 10.0, was used as the running electrolyte. The derivatization and separation conditions described herein are expected to be readily transposed to the capillary electrophoresis of other sialooligosaccharides such as those derived from glycoproteins.

2-Naphthylamine↗

Pulsed-field-trapping electrophoresis: a computer simulation study.

Experimental investigations have shown that adding a large, globular and neutral protein (such as streptavidin) at one end of the DNA fragments to be separated by gel electrophoresis strongly affects the dynamics of these molecules, leading to what is known as trapping electrophoresis (TE). In TE, the velocity decreases much more rapidly with DNA molecular size than under normal gel electrophoresis conditions, suggesting that TE may be used to increase the power of separation of polyacrylamide gel electrophoresis. Unfortunately, the bands are broader and fewer readable bands can fit on a single gel slab. Our previous theoretical study of TE also predicted the existence of long-lasting anomalous regimes where one cannot define a velocity or a diffusion constant. These secondary effects of trapping are related to the very broad distribution of detrapping times (the time needed to exit a trap). In order to increase the usefulness of TE, it has been suggested that pulsed fields may help the molecules exit traps more rapidly. In this article, we present a detailed numerical study of pulsed field TE. We conclude that simple pulsed fields alone may not be enough to increase the sequencing power of polyacrylamide TE because the rate of band broadening cannot be controlled. We also report the existence of anomalous regimes in the presence of pulsed fields, a factor that has been previously neglected in analytical models. Other approaches are also proposed.

Bacterial Proteins↗

Comparison of heparin-binding to lactoferrin from human milk and from human granulocytes by means of affinity capillary electrophoresis.

Human lactoferrin from two different sources: milk and secondary granules of neutrophil granulocytes, was compared with respect to heparin binding by means of affinity capillary electrophoresis. This method is based on analysis of migration pattern shifts induced by various amounts of ligand present in the electrophoresis buffer. Since lactoferrin is a basic molecule, analyses were performed at pH 8 in a capillary with a neutral hydrophilic coating. However, analyzable peaks were only obtained in the presence of heparin in the electrophoresis buffer. Proportionally to the amount of heparin present, these peaks exhibited shape changes and strong migration shifts. In the ensuing analysis it could be demonstrated that the two lactoferrins had comparable migration shifts and peak shape changes. This indicates that also in this respect the two forms of lactoferrin are identical. Affinity capillary electrophoresis is a convenient and fast method to investigate functional characteristics of low amounts of unmodified biomolecules.

Electrophoresis, Capillary↗

Capillary electrophoresis of biotechnology-derived proteins.

Applications of capillary electrophoretic techniques for the analysis of biotechnology-derived proteins continue at a steady pace. This review summarizes the analyses of these proteins achieved using capillary isoelectric focusing, micellar electrokinetic capillary chromatography, capillary electrophoresis/mass spectrometry and capillary gel electrophoresis. A very brief summary of each technique is included. Application of capillary isoelectric focusing to the analysis of recombinant tissue plasminogen activator in quality control type applications is examined in some detail. Analyses of dosage forms of biotechnology derived proteins of pharmaceutical importance as well as the identification and examination of the peptides, obtained after enzymatic cleavage of proteins, by capillary electrophoresis have been included. Examples of capillary gel electrophoresis as a substitute sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) of biotechnology-derived proteins are also reviewed.

Animals↗

Application of capillary electrophoresis for the determination of inorganic ions in trace explosives and explosive residues.

Capillary electrophoresis was developed for the analysis of low explosive residue, because a significant amount of inorganic anions and cations remain after deflagration. Certain high explosives, such as emulsion explosives, produce a vast quantity of inorganic ions after a blast and can readily be analyzed using capillary electrophoresis. Often, trace amounts of explosive residues may be present on physical evidence submitted in criminal cases. Trace amounts of inorganic ions such as nitrate, chlorate, and ammonium may be detected using capillary electrophoresis owing to the low detection limit of these species. The utility of capillary electrophoresis in the analysis of explosive residues is in its ability to simultaneously analyze trace explosives and ionic products present on physical evidence.

Anions↗

Screening for urinary methadone by capillary electrophoretic immunoassays and confirmation by capillary electrophoresis-mass spectrometry.

This paper characterizes competitive binding, electrokinetic capillary-based immunoassays for urinary methadone using reagents which were commercialized for a fluorescence polarization immunoassay. After incubation of 25 microL urine with the reactants, a small aliquot of the mixture is applied onto a fused-silica capillary and the unbound fluorescein-labeled methadone tracer is monitored by capillary electrophoresis with on-column laser-induced fluorescence detection. Configurations in presence and absence of micelles were investigated, found to be capable of recognizing urinary methadone concentrations > or = 10 ng/mL, and shown to be suitable for rapid methadone screening of patient urines. Based upon shorter run times and a much better separation of free tracer and antibody-tracer complex, conditions without micelles are preferred. For confirmation analysis of urinary methadone and its major metabolite, 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine (EDDP), capillary electrophoresis in a pH 4.6 ammonium acetate-acetic acid buffer was interphased to an atmospheric pressure ionization triple quadrupole mass spectrometry system. Using positive ion electrospray ionization and the tandem mass spectrometry mode with collision-induced dissociation in the collision cell, fragmentation of the two substances was determined. For confirmation via direct urine injection or application of a urinary extract, in-source fragmentation was employed and the first quadrupole was operated in the selected ion monitoring mode by switching between the masses of relevant precursor/product ion sets for methadone (m/z = 310, 265) and EDDP (m/z = 278, 249, 234). This capillary electrophoresis-mass spectrometry approach is shown to permit the confirmation of methadone and EDDP in patient urines that tested positive for methadone using electrokinetic capillary-based immunoassays, a fluorescence polarization immunoassay, and capillary electrophoresis with UV absorption detection.

Electrophoresis, Capillary↗

Sequencing using capillary electrophoresis of short tandem repeat alleles separated and purified by high performance liquid chromatography.

Polymerase chain reaction (PCR) amplified alleles need to be isolated and purified before carrying out additional analysis to confirm sequence, number of repeats and microvariants within a short tandem repeat (STR) locus. Also, PCR amplification of tetranucleotide repeat loci, used in DNA typing assays, often result in heteroduplex formation, adding to the complexity of analysis. Sequencing reactions require single specific target DNA for reliable sequencing analysis. Alkylated poly(styrene-divinylbenzene) columns at elevated temperature and gradient elution conditions increase the efficiency of separation to allow for the purification of PCR products. Using the separation technique of ion-pairing reverse-phase (IPRP) high performance liquid chromatography (HPLC), molecular biologists can separate and purify DNA fragments without alteration to the double-stranded DNA sequencing properties. In this study, the IP-RP chromatography technique has been demonstrated by separation of alleles of the short tandem repeat loci of TH01, vWA31, F13A01 and FES/ FPS. Alleles differing in size range of 12 to 4 base pairs were separated by IPRP/HPLC and individual alleles were peak-captured, then cycle-sequenced. These HPLC fractions required no additional steps prior to cycle sequencing. Capillary electrophoresis (CE) was used to sequence the alleles. Furthermore, CE offers advantages over traditional slab methods via automation and higher applied voltages. Interestingly, unlike traditional gel electrophoresis, samples were introduced into the sieving matrix by electrokinetic injection, which allows for multiple injections from a single sample, a key feature for method development. Applied voltage was 320 V per centimeter using a nonderivatized fused silica capillary with an interior diameter of 50 microm and a total length of 47 centimeters. The total analysis time including capillary filling and pre-electrophoresis was less than 30 min for a 220-bp fragment. A sequencing rate of 530 bp/h was achieved using these conditions. By combining the techniques of HPLC separation and CE sequencing, the results confirmed the sequence and number of nucleotide repeats for each STR loci. An average sequencing efficiency of 97% was achieved. Additionally, this method defined the absence of a 9.3 microvariant for a TH01 heterozygous individual previously typed as a 9, 9.3/10 using slab gel electrophoresis. The techniques described can be applied to other DNA purification and isolation problems.

Alleles↗

Detection of p53 point mutations by single strand conformation polymorphism: analysis by capillary electrophoresis.

We have analyzed five p53 single point mutations by single strand conformation polymorphism using capillary electrophoresis (CE-SSCP) and have compared these measurements to measurements obtained by slab gel electrophoresis (SG-SSCP). PCR primers were used for amplification of specific exons for mutation detection. 5' Primers were labeled with FAM (5-carboxyfluorescein) and 3' primers were labeled with JOE (2',7'-dimethoxy-4',5'-dichloro-6-carboxyfluorescein). CE-SSCP was performed using the Perkin Elmer ABI PRISM 310 Genetic Analyzer with GeneScan Software and the Beckman P/ACE 5510 CE equipped for laser-induced fluorescence detection. Although the shifts in migration times for the p53 mutations relative to the corresponding wild-type strands could be successfully detected by either SG or CE analysis, the individual electrophoresis run times were about tenfold faster and more automated with capillary electrophoresis. The CE-SSCP measurements were performed at temperatures ranging from 10 to 60 degrees C on a prototype instrument. For mutations measured at ambient temperature (25 degrees C), characteristic shifts in direction and magnitude were observed in the migration times of both strands of all mutations relative to the wild type. This demonstrated the ability of CE at ambient temperature to resolve these mutations. However, the magnitude and direction of shifts in migration time varied with temperature in a discrete pattern for each mutation and resulted in a temperature-specific profile for each mutation. This demonstrated that extended temperature control will be an important advantage in resolving single point mutations by CE-SSCP. In addition, by using CE, discrete intra-strand isoforms could be easily observed at different temperatures. The combination of mutation-specific temperature profiling and analysis of isoforms by CE-SSCP should be of help to the diagnostic community in the detection of genetic mutations.

DNA Mutational Analysis↗

Assessment of pharmacodynamic and pharmacokinetic characteristics of drugs using microdialysis sampling and capillary electrophoresis.

Microdialysis sampling combined with capillary electrophoresis is emerging as a new approach in drug studies. It allows the continuous monitoring, in vivo or in vitro, of changes in free endogenous compounds as well as in drug substances, following the administration of pharmacological agents. The low volume requirement of capillary electrophoresis for injection allows the collection of dialysates during short sampling times, leading to a precise temporal description of drug-induced biochemical changes or pharmacokinetics. Various protocols can be used for analyzing endogenous compounds and drug substances in microdialysis samples. Capillary electrophoresis with laser-induced fluorescence detection often affords the high sensitivity level which is needed in most studies. Furthermore, the direct on-line coupling of microdialysis, derivatization of samples, and electrophoretic analysis now brings a separation-based biosensor, allowing a real-time description of chemical events with a high molecular specificity. Microdialysis sampling combined with capillary electrophoresis has recently been used to assess pharmacodynamic and pharmacokinetic characteristics of various drugs in animal studies; it may also represent a new approach in clinical pharmacology in the near future.

Animals↗