At least 559 records · Page 31Linked to original sources

Clinical experience with the mini-extracorporeal circulation system: an evolution or a revolution?

PURPOSE: We studied a cohort of 150 patients operated on with a new cardiopulmonary bypass (CPB) system. This is the mini-extracorporeal circulation (MECC) system. DESCRIPTION: The MECC is a fully heparin coated closed-loop CPB system that includes a centrifugal pump and has a priming volume of 450 mL. Between March 2001 and September 2002, 150 consecutive patients were operated on using the mini-CPB (MECC) method. This includes 105 coronary artery bypass graft and 45 aortic valve replacement patients. The median age was 66.7 +/- 10.7 years with a gender ratio of 3.27 males to 1 female. EVALUATION: The 30-day operative mortality was 1.3%. The hemoglobin concentration was stable and perioperative transfusion was needed in only 6% of all patients. The renal and neuropsychiatric complications were less than 1%. CONCLUSIONS: In our experience, the MECC system is a reliable new concept for CPB with good clinical results.

Aged↗

Placental compliance during fetal extracorporeal circulation.

The fetus requires large amounts of volume when weaning from cardiac bypass. This suggests that placental vasculature can act as a large capacitor in the fetal circulation. To assess placental compliance of fetal lambs, seven isolated in situ lamb placentas were placed on extracorporeal circulation. Umbilical artery blood flow was varied from 0 to 350 ml. min(-1). kg fetal wt(-1). Because the extracorporeal circuit is a closed system, volume changes in the placenta induced by umbilical artery pressure changes were measured from reciprocal volume changes in the reservoir. There was a wide range of change in absolute volume of blood within the fetal placental compartment (216.4 +/- 29.3 ml). Placental compliance was linear over the entire range of pressure changes exerted on the placental vasculature (r(2) = 0.83, P = 0.0001). This indicates that the placenta is a unique and sensitive capacitor in the fetal circulation. This information is important clinically because it establishes that aggressive resuscitation of the fetus using volume may be necessary when weaning the fetus from cardiac bypass.

Animals↗

[Blood calcium levels in heart defects after surgery with extracorporeal circulation].

The total content of calcium and protein was studied in 50 patients during the initial 5 days after surgery for their congenital or acquired heart diseases conducted under extracorporeal circulation; in half of them the content of the dialysing fraction of total calcium and plasma albumins were also examined. The study has demonstrated that during the 1st postoperative day the content of the total and dialysing calcium is elevated which is due to the administration of calcium for the neutralization of citrate during blood transfusions. The greatest fluctuations of these values (both decreases and increases) were observed when the heart-lung machine was primed with blood containing 18.2--23mEg Ca++ per 1 1 of citrate blood. Within the early 5 postoperative days no restoration of the impaired calcium balance is observed in these patients, while the blood content of calcium is returning to the preoperative level. The blood content of calcium was studied after repeated injections of various doses of calcium. The most rational method proved to consist in repeated injections of 5ml of 10% CaCl2 solution every 30 min--1 hour which resulted in a moderate elevation of the blood content of the total and dialysing calcium.

Blood Proteins↗

Prevention by ticlopidine of platelet consumption during extracorporeal circulation for heart surgery and lack of effect on operative and postoperative bleeding.

We studied the effects of ticlopidine, a platelet antiaggregant drug, on platelet consumption during and after extracorporeal circulation (ECC) and on the operative and postoperative blood loss in a double-blind, placebo-controlled trial on 20 patients who underwent open-heart surgery for implantation of a valvular prosthesis. We monitored the changes in platelet count during and after ECC, the need for platelet transfusions to compensate for excessive consumption, and the operative and postoperative blood loss. We also followed the cephalin-kaolin time, the prothrombin time, the fibrinogen level, the fibrin/fibrinogen degradation products, and the euglobulin lysis time. Ticlopidine effectively reduced operative and post-ECC thrombopenia and prolonged the bleeding time. Apart from these changes, no differences in coagulation tests were observed between the ticlopidine-treated group and the placebo group. No side effects were observed. There was no significant difference between the groups concerning operative and postoperative blood loss, indicating that ticlopidine does not induce a hemorrhagic diathesis. Ticlopidine therapy may be of value during the first postoperative days because it prevents clotting on valvular prosthesis and complications such as systemic embolization. However, more trials and controlled studies are needed before such therapy can be recommended for routine use.

Adult↗

[Inflammatory and fibrinolytic activation after coronary artery bypass with extracorporeal circulation].

BACKGROUND: The aim of this study was to determine the course of the main inflammatory and fibrinolytic markers in patients undergoing primary elective coronary artery bypass graft with extracorporeal circulation. METHODS: One hundred and thirteen patients (105 males, 8 females) undergoing primary isolated coronary artery bypass with normo- (37 degrees C) or hypothermic (26 degrees C) systemic perfusion were prospectively studied. The clinical course of the patients was recorded and inflammatory and fibrinolytic markers (C-reactive protein, fibrinogen, interleukin-6, plasminogen activator inhibitor-1, prothrombin time, activated partial thromboplastin time, platelets and white blood cell counts) were determined before surgery, 24, 48 and 72 hours thereafter, and at hospital discharge. RESULTS: Two patients died (mortality 1.7%) and 6 had a major complication (event free survival > 94%). Interleukin-6, lymphocyte, neutrophil and monocyte levels increased after surgery but returned to normal at hospital discharge. C-reactive protein levels increased after 24 hours and remained high at hospital discharge. Plasminogen activator inhibitor-1, prothrombin time, and activated partial thromboplastin time increased from few hours postoperatively and returned to normal before discharge. Platelets decreased immediately after surgery and normalized only at hospital discharge. Fibrinogen decreased in the first 24 postoperative hours, raised later and remained elevated at hospital discharge. CONCLUSIONS: Cardiopulmonary bypass activates inflammatory response and hemostatic/fibrinolytic balance in patients undergoing primary isolated coronary artery bypass.

Aged↗

Biventricular pacing for weaning from extracorporeal circulation in heart failure.

Resynchronization of the intra- and interventricular conduction by biventricular pacing has been suggested in patients with end-stage heart failure. We present a case in which extracorporeal circulation could only be weaned after placement of an additional left ventricular pacing wire. Biventricular stimulation led to normal motion of the anterior wall and a previously bulging interventricular septum; this improved the hemodynamic situation significantly.

Aged↗

Clinical experience with Nikkiso centrifugal pumps for extracorporeal circulation.

A comparative study of a newly developed impeller-type centrifugal pump, Nikkiso HMS-15, was made to assess the effects on hemolysis, platelet function, and renal function for extracorporeal circulation (ECC) during open heart surgery. The Bio-pump (cone-type, Medtronic) and the roller pump were used as controls. The increase of serum hemoglobin level in the Nikkiso pump was significantly lower than that in the other pumps. The decrease of platelet counts was recognized after the initiation of ECC in the three pumps whereas the levels of platelet factor 4 and beta-thromboglobulin in the Nikkiso pump group increased by far less than in the other two groups. Moreover, renal function was better maintained in the Nikkiso pump group; in particular, a significantly higher urine output was recorded during ECC and for 1 h after the termination of ECC. The results of our clinical studies suggest that the Nikkiso centrifugal pump is suitable for ECC during open heart surgery.

Extracorporeal Circulation↗

Biocompatibility of extracorporeal circulation. In vitro comparison of heparin-coated and uncoated oxygenator circuits.

Oxygenator/tubing sets coated with endpoint-attached heparin were compared to uncoated sets in a dynamic model of extracorporeal circulation. Biocompatibility was assessed by evaluations of complement activation and platelet loss. The median concentration of C3 activation products increased gradually from 12 AU/ml at baseline to 65 AU/ml after 120 minutes in the uncoated sets and from 12 AU/ml to 19 AU/ml after 120 minutes in the coated sets (p less than 0.002). The median concentration of the terminal complement complex in the uncoated sets increased gradually from 3.1 AU/ml at baseline to 18.2 AU/ml after 120 minutes. In the coated sets the terminal complement complex reached a peak of 12.0 AU/ml at 15 minutes and returned to baseline values at 60 minutes. Median platelet loss at 120 minutes was 166 x 10(9) in the uncoated and 21 x 10(9) in the coated sets (p less than 0.01). Heparin coating thus improved biocompatibility by reducing both complement activation and platelet loss.

Biocompatible Materials↗

A surgeon's view of extracorporeal circulation.

Because this lecture series is named after Dr. John Gibbon, an examination of the remarkable developments that were set in motion by John and Maly Gibbon's work on extracorporeal circulation is not only appropriate to this forum but is, in fact, long overdue. Although John Gibbon and his wife have been honored in many countries for their basic contribution to medicine, it is my belief that the work was of Nobel stature, and I am sure that if the rules for selecting a Nobel prize winner had been different, John Gibbon would have certainly been the recipient. I feel particularly pleased to be speaking of them today because what may be the most important trip I ever took was a visit to their laboratory in Philadelphia in 1952 to watch their progress in developing the heart-lung machine. As we were doing research in the field and had no pump, he gave me one of his original circular pumps, which we subsequently used with our disc oxygenator in the first 300 open heart operations performed in our unit.

Animals↗

Haemostasis disorders in open heart surgery with extracorporeal circulation. Importance of the platelet function and the heparin neutralization.

The main haemostasis changes observed in a screening study performed in 40 patients who underwent an open heart surgery with extracorporeal circulation (ECC) are: a significant drop in platelet count from the onset of the ECC to the third postoperative day, a decrease of platelet retention and aggregation during ECC with an 8-day persistently increased heparin-neutralizing activity in plasma but not in serum, a moderate decrease of plasma factors I, II, VII-X, X and XIII and a more important drop in factor V which disappears 24 h after ECC, a transitory increase of fibrinolysis during ECC and the lack of FDP elevation in the serum. These disorders require a very good neutralization of the heparin used during ECC. The ratio protamine/heparin can be established by a titration clotting time test. Protamine chloride seems to be more efficacious and to act more quickly than protamine sulfate for the neutralization. An overload in protamine can enhance the hemostatic, biological and clinical disorders. The preventive administration of platelet concentrate immediately after the heparin neutralization contributes to reduce the bleeding disorders related to the quantitative and qualitative platelet defects.

Blood Cell Count↗

[The effects of dopamine on the renin-angiotensin-aldosterone system after extracorporeal circulation].

Thirty-one patients underwent elective coronary bypass grafting were studied about the effects of dopamine (DOP) on the renin-angiotensin-aldosterone system (RAAS) for 24 hours after extracorporeal circulation (ECC). All of them had no evident of renal dysfunction nor other complication preoperatively. Patients were divided according to the administration of DOP 5-10 micrograms/kg/min (group D, n = 16) and control group without any catecholamine including DOP (group N, n = 15). Criteria for DOP administration were systolic blood pressure less than 100 mmHg and central venous pressure greater than 15 cmH2O. Hemodynamically no significant difference was observed between the two groups. The RAAS was activated by ECC in both groups. Plasma renin activity (PRA) and plasma angiotensin II-levels (AII) returned to normal range at 6 hours after ECC in group D which is significantly less than group N where PRA and AII remained elevated at 24 hours after ECC. Plasma aldosterone levels (ALD) did not show any significant difference between the two groups. AII changed proportionately to PRA, whereas ALD did not correlate with PRA or AII in the both groups. These results suggested that in early postoperative period angiotensin II didn't cause peripheral vasoconstriction in group D, and administration of DOP in doses of 5-10 micrograms/kg/min resulting in a low level of AII is safe and useful in view of data that a high AII promotes multifocal myocardial necrosis and renal tubular degeneration.

Adult↗

Comparison of two methods for heparin monitoring: a semi-automated heparin monitoring device and activated clotting time during extracorporeal circulation.

Two methods of heparin monitoring, semi-automated in-vivo heparin protamine titration (HPT) and activated clotting time (ACT), were compared in each of sixteen adult patients undergoing extracorporeal circulation (ECC) for coronary artery bypass surgery. The HPT method determined the initial and maintenance level of heparin for ECC, as well as, the amount of protamine needed for neutralization of heparin. ACT determinations were made in parallel to calculate heparin levels, heparin sensitivity, and protamine requirements. ACT determinations increased from 502 +/- 31 seconds after heparinization to 739 +/- 49 seconds (p less than 0.05) five minutes after the start of ECC. The HPT method determined heparin sensitivity to be 153 +/- 17 secs/mg/kg and this did not change after the institution of ECC. The increase in ACT observed after the start of ECC resulted in an increase in heparin sensitivity from 151 +/- 13 secs/mg/kg initially, to 247 +/- 17 secs/mg/kg after the institution of ECC (p less than 0.01). During ECC, the HPT method reported heparin levels which remained near the initial value of 2.40 +/- 0.12 mg/kg. The ACT method's initial heparin level of 2.66 +/- 0.12 mg/kg rose after the start of ECC to 4.39 +/- 0.55 mg/kg (p less than 0.05). The HPT method adequately predicted protamine requirements, 2.66 +/- 0.15 mg/kg protamine vs. 3.47 +/- 0.14 mg/kg actual dose while the ACT method predicted excess: 5.02 +/- 0.34 mg/kg (p less than 0.01). In-vivo heparin-protamine titration method provided more consistent information during ECC and directed a significantly smaller dose of protamine for heparin neutralization.

Blood Coagulation Tests↗

Muscle oxygen tension, hemodynamics, and oxygen transport after extracorporeal circulation.

In eight patients who underwent elective coronary bypass operation, skeletal muscle PO2 was measured with a polarographic needle electrode as an index of peripheral tissue perfusion to study recovery after extracorporeal circulation. Measurements of skeletal muscle PO2 and O2 supply to the tissues were obtained immediately after ICU admission and after 2, 4, 8, and 16 h. During the first 2 h, mean arterial BP was high, mixed venous PO2 decreased, the arteriovenous O2 difference increased, and skeletal muscle PO2 decreased. The P50 of the O2 dissociation curve on ICU admission was decreased and thereafter increased to a maximal value at 8 h, and normalized again after 16 h. After the initial decrease, the median of the skeletal muscle PO2 returned to normal values, but decreased again after 16 h. The results showed that, during the first 4 h postoperatively, microcirculatory changes occurred despite normal cardiovascular and respiratory variables.

Aged↗

Comparison of the standard roller pump and a pulsatile centrifugal pump for extracorporeal circulation during routine coronary artery bypass grafting.

The present prospective study compared the standard nonpulsatile twin roller pump with the Sarns centrifugal pump, in the pulsatile mode, as arterial pumps for extracorporeal circulation during coronary artery bypass grafting (CABG). The study was conducted in two consecutive groups of 25 patients receiving a standard anaesthetic and surgical protocol. The investigated parameters included haemodynamic profiles, oxygen exchange, blood gas and acid-base homeostasis, haematology, coagulation and complement consumption. With comparable settings for pump flow, gas flow and delivered oxygen concentrations, there was no difference between the groups in the main haemodynamic parameters during cardiopulmonary bypass (CPB). However, a tenfold lower dose of sodium nitroprusside was required to keep systemic vascular resistance within physiologic limits during CPB in the centrifugal group (C group) compared with the roller group (R group). During rewarming oxygen extraction was higher in the C group than in the R group. During the first eight hours after CPB no differences in haemodynamics, oxygenation parameters and pulmonary shunt between the groups were observed. During, as well as after, CPB there was no significant difference in blood gas and acid-base homeostasis between either group. Average postoperative blood loss via chest tubes, total transfusions of blood products, haemoglobin and coagulation did not differ between the two groups. However, the white blood cell count, corrected for changes in haematocrit, decreased during the early phase of CPB in the R group, but not in the C group.(ABSTRACT TRUNCATED AT 250 WORDS)

Aged↗

[Characteristic features of allogenic transfusions in elderly patients with ischemic heart disease in operations under conditions of extracorporeal circulation and using cell saver].

It was shown that in spite of using different methods of saving the autologous patient's blood, cell saver included, in elderly patients operated upon under conditions of extracorporeal circulation the frequency and volume of allogenic transfusions was higher as compared with the younger patients, in elderly women the allogenic transfusions being necessary more frequently.

Aged↗

Safety of lumbar drains in thoracic aortic operations performed with extracorporeal circulation.

BACKGROUND: The safety of cerebrospinal fluid (CSF) drainage in thoracic aortic surgery using extracorporeal circulation (ECC) with systemic heparinization has not been established. METHODS: Four hundred thirty-two patients had descending thoracic or thoracoabdominal aortic repair between 1993 and 2002. One hundred sixty-two of those patients (age range, 67 +/- 13 years) had repairs performed with ECC, systemic anticoagulation, and lumbar CSF drainage. Repairs performed without CSF drainage, without ECC, or by stent graft (n = 53) were excluded. The CSF catheters were inserted at L3 to L5. Cerebrospinal fluid was drained to maintain pressures of 10 to 12 mm Hg. In the absence of neurologic deficit or coagulopathy, the catheters were capped at 24 hours and removed at 48 hours. Cerebrospinal fluid drainage was continued beyond 24 hours for delayed onset paraparesis. RESULTS: Cerebrospinal fluid drains were used in 135 thoracoabdominal aortic aneurysms (extent I, n = 63; extent II, n = 25; extent III, n = 39; extent IV, n = 8) and 27 descending thoracic aortic repairs (aneurysm, n = 24; traumatic aortic injury, n = 2; aortic coarctation, n = 1). Partial left heart bypass was used in 132 patients, full cardiopulmonary bypass without deep hypothermic circulatory arrest in 5, and cardiopulmonary bypass with adjunctive deep hypothermic circulatory arrest in 25. Time between catheter insertion and anticoagulation was 153 +/- 60 minutes. Heparin achieved an average maximum activated clotting time of 528 +/- 192 seconds. Average ECC time was 114 +/- 77 minutes. Average deep hypothermic circulatory arrest time was 40 +/- 12 minutes. Mortality was 14.1% (23 of 162), and permanent paraplegia was 4.9% (8 of 162). No epidural or spinal hematoma was observed. Six (3.7%) patients had catheter-related complications (temporary abducens nerve palsy [n = 1]; retained catheter fragments [n = 2]; retained catheter fragment and meningitis [n = 1]; isolated meningitis [n = 1]; and spinal headache [n = 1]). CONCLUSIONS: The CSF drainage in thoracic aortic surgery using ECC with full anticoagulation did not result in hemorrhagic complications. The permanent paraplegia rate in this complex patient population consisting of combined distal arch, thoracoabdominal aortic procedures were low, and lumbar CSF catheter-related complications had no permanent sequelae.

Adult↗

Evaluation of tests for heparin control during long-term extracorporeal circulation.

Two coagulation tests, Recalcified Activated Clotting Time (RACT) and Hemochron, were compared with the activated partial thromboplastin time (APTT) in in vitro heparinization experiments and in patients heparinized for long term extracorporeal circulation (ECC) to determine their suitability as guidelines for heparin administration. All tests had good precision, with a small variability between methods. There was satisfactory correlation with the heparin level in vivo (r = 0.77 for RACT; r = 0.80 for Hemochron and r = 0.82 for APTT) too, while the in vitro r was always greater than or equal to 0.94. Nevertheless, APTT values for plasma heparin levels higher than 1.5 U/ml were markedly prolonged, with a large standard deviation, and often "unclottable". The good correlation between the three tests, makes it possible to substitute RACT and Hemochron for APTT, during long-term ECC.

Analysis of Variance↗

[Enzymatic changes in the lymph in the thoracic duct and right lymphatic duct during extracorporeal circulation in the dog (author's transl)].

The authors analysed the various enzymes in the lymph of the thoracic duct and the right lymphatic duct in a series of 15 dogs submitted to extracorporeal circulation, the experimentors noted a series of diffuse cellular lesions which involved transiently the main organs. This lesion seems only to occur at first; independent of the duration of the by-pass, probably due to hypoxia following the rapid and massive introduction of priming. Our conclusion from this research is that lymph analysis is more revealing for knowledge of enzyme behaviour than blood analysis. A differential study of lymph in the right lymphatic duct and in the thoracic duct is surprisingly much less important.