PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Power”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31Linked to original sources

The effects of length trajectory on the mechanical power output of mouse skeletal muscles.

The effects of length trajectory on the mechanical power output of mouse soleus and extensor digitorum longus (EDL) muscles were investigated using the work loop technique in vitro at 37 degrees C. Muscles were subjected to sinusoidal and sawtooth cycles of lengthening and shortening; for the sawtooth cycles, the proportion of the cycle spent shortening was varied. For each cycle frequency examined, the timing and duration of stimulation and the strain amplitude were optimized to yield the maximum power output. During sawtooth length trajectories, power increased as the proportion of the cycle spent shortening increased. The increase in power was attributable to more complete activation of the muscle due to the longer stimulation duration, to a more rapid rise in force resulting from increased stretch velocity and to an increase in the optimal strain amplitude. The power produced during symmetrical sawtooth cycles was 5-10 % higher than during sinusoidal work loops. Maximum power outputs of 92 W kg-1 (soleus) and 247 W kg-1 (EDL) were obtained by manipulating the length trajectory. For each muscle, this was approximately 70 % of the maximum power output estimated from the isotonic force-velocity relationship. We have found a number of examples suggesting that animals exploit prolonging the shortening phase during activities requiring a high power output, such as flying, jet-propulsion swimming and vocalization. In an evolutionary context, increasing the relative shortening duration provides an alternative to increasing the maximum shortening velocity (Vmax) as a way to increase power output.

Animals↗

The changes in power requirements and muscle efficiency during elevated force production in the fruit fly Drosophila melanogaster.

The limits of flight performance have been estimated in tethered Drosophila melanogaster by modulating power requirements in a 'virtual reality' flight arena. At peak capacity, the flight muscles can sustain a mechanical power output of nearly 80 W kg-1 muscle mass at 24 degrees C, which is sufficient to generate forces of approximately 150% of the animal's weight. The increase in flight force above that required to support body weight is accompanied by a rise in wing velocity, brought about by an increase in stroke amplitude and a decrease in stroke frequency. Inertial costs, although greater than either profile or induced power, would be minimal with even modest amounts of elastic storage, and total mechanical power energy should be equivalent to aerodynamic power alone. Because of the large profile drag expected at low Reynolds numbers, the profile power was approximately twice the induced power at all levels of force generation. Thus, it is the cost of overcoming drag, and not the production of lift, that is the primary requirement for flight in Drosophila melanogaster. By comparing the estimated mechanical power output with respirometrically measured total power input, we determined that muscle efficiency rises with increasing force production to a maximum of 10%. This change in efficiency may reflect either increased crossbridge activation or a favorable strain regime during the production of peak forces.

Animals↗

Gender differences in anaerobic power of the arms and legs--a scaling issue.

PURPOSE: Physiological variables must be scaled for body size differences to permit meaningful comparisons between groups. Using allometric scaling, this study compared the anaerobic performance, using both arms and legs, of men and women. Ten active male and 10 active female subjects performed the leg cycling and arm cranking in a 30-s all-out Wingate test (WAnT). Regional measurements of the legs, gluteal area, arms, and torso taken using dual-energy x-ray absorptiometry (DXA) served as indicators of lower body active musculature (LBAMM) and upper body (UBAMM) active musculature. RESULTS: Body mass (BM) was the best predictor (i.e., r = 0.93-0.96) for peak power (PP) and mean power (MP) generated from sprint cycling and arm cranking. Sex differences for leg and arm power (i.e., PP and MP) were identified in absolute terms and then expressed in ratio to BM(1.0). When the same data were allometrically scaled to BM and expressed as power function ratios (Power;BM(b)), the sex differences in PP and MP for sprint cycling were nullified (female:male ratio x 100: 100-103%), but remained for arm cranking (female:male power ratio x 100: 69-84%). CONCLUSIONS: These results confirmed that anaerobic power of the upper body and lower body were best normalized to BM and, when statistically appropriate methods were used to take into account differences in BM, PP, and MP generated from sprint cycling were similar for both men and women. In contrast, after allometric scaling for BM, men remained more powerful than women for the supramaximal arm cranking task. Qualitative differences in the upper body musculature between men and women are speculated to account for the more powerful performance of men, but confirmatory evidence using noninvasive techniques is warranted.

Adult↗

Effects of plyometric training and recovery on vertical jump performance and anaerobic power.

We examined the effects of 2 plyometric training programs, equalized for training volume, followed by a 4-week recovery period of no plyometric training on anaerobic power and vertical jump performance. Physically active, college-aged men were randomly assigned to either a 4-week (n = 19, weight = 73.4 +/- 7.5 kg) or a 7-week (n = 19, weight = 80.1 +/- 12.5 kg) program. Vertical jump height, vertical jump power, and anaerobic power via the Margaria staircase test were measured pretraining (PRE), immediately posttraining (POST), and 4 weeks posttraining (POST-4). Vertical jump height decreased in the 4-week group PRE (67.8 +/- 7.9 cm) to POST (65.4 +/- 7.8 cm). Vertical jump height increased from PRE to POST-4 in 4-week (67.8 +/- 7.9 to 69.7 +/- 7.6 cm) and 7-week (64.6 +/- 6.2 to 67.2 +/- 7.6 cm) training programs. Vertical jump power decreased in the 4-week group from PRE (8,660.0 +/- 546.5 W) to POST (8,541.6 +/- 557.4 W) with no change in the 7-week group. Vertical jump power increased PRE to POST-4 in 4-week (8,660.0 +/- 546.5 W to 8,793.6 +/- 541.4 W) and 7-week (8,702.8 +/- 527.4 W to 8,931.5 +/- 537.6 W) training programs. Anaerobic power improved in the 7-week group from PRE (1,121.9 +/- 174.7 W) to POST (1,192.2 +/- 189.1 W) but not the 4-week group. Anaerobic power significantly improved PRE to POST-4 in both groups. There were no significant differences between the 2 training groups. Four-week and 7-week plyometric programs are equally effective for improving vertical jump height, vertical jump power, and anaerobic power when followed by a 4-week recovery period. However, a 4-week program may not be as effective as a 7-week program if the recovery period is not employed.

Analysis of Variance↗

One- and 3-minute plaque removal by a battery-powered versus a manual toothbrush.

BACKGROUND: A new battery-powered toothbrush with a fundamentally different design than other powered toothbrushes has recently been introduced. The new toothbrush has a powered oscillating round head and a second powered head that translates back and forth. This study compared the plaque removal efficacy of a manual toothbrush to this new powered toothbrush. METHODS: This randomized, controlled, examiner-masked, four-period cross-over study examined plaque removal with the two toothbrushes following a single use in 40 subjects. Plaque was scored before brushing and after 1 and 3 minutes of brushing using the Turesky modification of the Quigley-Hein index. RESULTS: Baseline plaque scores were 2.98 prior to using the powered toothbrush and 2.99 prior to using the manual toothbrush. The powered toothbrush delivered a covariance-adjusted mean plaque score change from baseline of 0.61 after 1 minute of brushing and 0.93 after 3 minutes of brushing. The adjusted mean changes for the manual toothbrush were 0.43 and 0.62, respectively. The differences between treatment groups were statistically significant (P < 0.001) after both 1 and 3 minutes of brushing. The powered toothbrush had, on average, 42.1% and 49.6% greater plaque removal scores after 1 minute and 3 minutes of brushing, respectively. Both toothbrushes had statistically significantly greater plaque removal scores after 3 minutes than after 1 minute of brushing (P < 0.001). Plaque removal scores for each toothbrush after 3 minutes of brushing were about 50% higher than the scores after 1 minute of brushing. CONCLUSIONS: The powered toothbrush delivered statistically significantly superior plaque removal after both 1 and 3 minutes of brushing compared to the manual toothbrush. Both toothbrushes showed statistically significantly greater plaque removal following 3 minutes of brushing than following 1 minute of brushing, and the difference between the toothbrushes was greater following 3 minutes of brushing than following 1 minute of brushing.

Adult↗

Muscle power output properties using the stretch-shortening cycle of the upper limb and their relationships with a one-repetition maximum bench press.

The purpose of this study was to examine the output properties of muscle power by the dominant upper limb using SSC, and the relationships between the power output by SSC and a one-repetition maximum bench press (1 RM BP) used as a strength indicator of the upper body. Sixteen male athletes (21.4+/-0.9 yr) participated in this study. They pulled a load of 40% of maximum voluntary contraction (MVC) at a stretch by elbow flexion of the dominant upper limb in the following three preliminary conditions: static relaxed muscle state (SR condition), isometric muscle contraction state (ISO condition), and using SSC (SSC condition). The velocity with a wire load via a pulley during elbow flexion was measured accurately using a power instrument with a rotary encoder, and the muscle power curve was drawn from the product of the velocity and load. Significant differences were found among all evaluation parameters of muscle power exerted from the above three conditions and the parameters regarding early power output during concentric contraction were larger in the SSC condition than the SR and ISO conditions. The parameters on initial muscle contraction velocity when only using SSC significantly correlated with 1 RM BP (r=0.60-0.62). The use of SSC before powerful elbow flexion may contribute largely to early explosive power output during concentric contraction. Bench press capacity relates to a development of the above early power output when using SSC.

Adult↗

Strength and power assessment. Issues, controversies and challenges.

Athletic strength and power refer to the forces or torques generated during sporting activity. Their assessment can be used for strength diagnosis or talent identification, to monitor the effects of training interventions and to estimate the relative significance of strength and power to particular athletic pursuits. However, strength and power assessment is a difficult task. Reasons for this include: the fledgling status of research within the area, our limited understanding of the mechanisms underpinning strength and power performance and development, and limitations associated with various forms of dynamometry. This article describes a frame work for the collection of data which may ultimately lead to recommendations for the assessment of strength and power in sporting contexts. Such a framework will be evolutionary and depends upon synergistic improvements in our understanding of: the physiological mechanisms underpinning strength and power development; the effect that various training regimens have upon the development of strength and power; and factors influencing the validity and reliability of dynamometry. Currently, isometric, isoinertial and isokinetic dynamometry are employed in assessment. Each form has its supporters and detractors. Basically, proponents and critics of isokinetic and isometric dynamometry emphasis their apparently high internal and apparently low external [corrected] validity respectively. While the converse applies for isoinertial dynamometry. It appears that all 3 modalities can have acceptable reliability, however this should be established rather than assumed, as the reliability of each can be threatened by a number of considerations (e.g. instruction for isometric tasks, the impact of weight used during weighted jumping tasks, and the effects of gravity and feedback on isokinetic performance). While reliability is a seminal issue in assessment, it is not the only critical issue. Specifically, there has been little research into the correlation between strength and power measures and athletic performance. This work is central to the use of such indices in talent identification. To date, this work has generally been limited to heterogeneous rather than homogeneous groups. More work is required in this area. Furthermore, not all modes of assessment are sensitive or similarly sensitive to various training interventions. This suggests that these modalities are measuring different neuromuscular qualities. How these qualities relate to performance requires more work, and will determine the contexts in which various strength and power assessment modalities and protocols are used.(ABSTRACT TRUNCATED AT 400 WORDS)

Biomechanical Phenomena↗

Reliability of power in physical performance tests.

The reliability of power in tests of physical performance affects the precision of assessment of athletes, patients, clients and study participants. In this meta-analytic review we identify the most reliable measures of power and the factors affecting reliability. Our measures of reliability were the typical (standard) error of measurement expressed as a coefficient of variation (CV) and the percent change in the mean between trials. We meta-analysed these measures for power or work from 101 studies of healthy adults. Measures and tests with the smallest CV in exercise of a given duration include field tests of sprint running (approximately 0.9%), peak power in an incremental test on a treadmill or cycle ergometer (approximately 0.9%), equivalent mean power in a constant-power test lasting 1 minute to 3 hours on a treadmill or cycle ergometer (0.9 to 2.0%), lactate-threshold power (approximately 1.5%), and jump height or distance (approximately 2.0%). The CV for mean power on isokinetic ergometers was relatively large (> 4%). CV were larger for nonathletes versus athletes (1.3 x), female versus male nonathletes (1.4 x), shorter (approximately 1-second) and longer (approximately 1-hour) versus 1-minute tests (< or = 1.6 x), and respiratory- versus ergometer-based measures of power (1.4 to 1.6 x). There was no clear-cut effect of time between trials. The importance of a practice trial was evident in studies with > 2 trials: the CV between the first 2 trials was 1.3 times the CV between subsequent trials; performance also improved by 1.2% between the first 2 trials but by only 0.2% between subsequent trials. These findings should help exercise practitioners and researchers select or design good measures and protocols for tests of physical performance.

Ergometry↗

Challenges in understanding the influence of maximal power training on improving athletic performance.

The ability to optimise muscular power output is considered fundamental to successful performance of many athletic and sporting activities. Consequently, a great deal of research has investigated methods to improve power output and its transference to athletic performance. One issue that makes comparisons between studies difficult is the different modes of dynamometry (isometric, isokinetic and isoinertial) used to measure strength and power. However, it is recognised that isokinetic and isometric assessment bear little resemblance to the accelerative/decelerative motion implicit in limb movement during resistance training and sporting performance. Furthermore, most people who train to increase power would have limited or no access to isometric and/or isokinetic dynamometry. It is for these reasons and for the sake of brevity that the findings of isoinertial (constant gravitational load) research will provide the focus of much of the discussion in this review. One variable that is considered important in increasing power and performance in explosive tasks such as running and jumping is the training load that maximises the mechanical power output (Pmax) of muscle. However, there are discrepancies in the research as to which load maximises power output during various resistance exercises and whether training at Pmax improves functional performance is debatable. There is also some evidence suggesting that Pmax is affected by the training status of the individuals; however, other strength variables could quite possibly be of greater importance for improving functional performance. If Pmax is found to be important in improving athletic performance, then each individual's Pmax needs to be determined and they then train at this load. The predilection of research to train all subjects at one load (e.g. 30% one repetition maximum [1RM]) is fundamentally flawed due to inter-individual Pmax differences, which may be ascribed to factors such as training status (strength level) and the exercise (muscle groups) used. Pmax needs to be constantly monitored and adjusted as research suggests that it is transient. In terms of training studies, experienced subjects should be used, volume equated and the outcome measures clearly defined and measured (i.e. mean power and/or peak power). Sport scientists are urged to formulate research designs that result in meaningful and practical information that assists coaches and strength and conditioning practitioners in the development of their athletes.

Biomechanical Phenomena↗

Computing asymptotic power and sample size for case-control genetic association studies in the presence of phenotype and/or genotype misclassification errors.

It is well established that phenotype and genotype misclassification errors reduce the power to detect genetic association. Resampling a subset of the data (e.g, double-sampling) of genotype and/or phenotype with a gold standard measurement is one method to address this issue. We derive the non-centrality parameter (NCP) for the recently published Likelihood Ratio Test Allowing for Error (LRTae) in the presence of random phenotype and genotype errors. With the NCP, power and sample size can be analytically determined at any significance level. We verify analytic power with simulations using a 2**k factorial design given high and low settings of: case and control genotype frequencies, phenotype and genotype misclassification probabilities, total sample size, ratio of cases to controls, and proportions of phenotype and/or genotype double-samples. We also perform example applications of our method assuming equal costs for the LRTae method and the standard method that does not use double-sample information (LRTstd) to determine if power gain due to double-sampling a proportion of samples outweighs the reduction in sample size due to additional costs in obtaining double-samples. Our results showed a median difference of at most 0.01 between analytic and simulation power for the factorial design settings, with maximum difference of 0.054. For our cost/benefits analysis calculations, results for genotype errors are that double-sampling appears most beneficial (in terms of power gain) when cost of double-sampling is relatively low, irrespective of the proportion of individuals double-sampled. In the presence of phenotype error, there is always power gain using the LRTae method for the parameter settings considered. We have freely available software that performs power and sample size calculations for the LRTae method and cost/benefits analyses comparing power for LRTae and LRTstd methods assuming equal costs.

Journal Article↗

Assessment of vascularity in hepatic tumors: comparison of power Doppler sonography and intraarterial CO(2)-enhanced sonography.

OBJECTIVE: The purpose of the study was to compare power Doppler sonography with intraarterial CO(2)-enhanced sonography for revealing vascularity in treated and untreated hepatic tumors. SUBJECTS AND METHODS: Fifty-five patients with 93 liver tumors were prospectively examined with power Doppler sonography and CO(2)-enhanced sonography. These tumors included 29 hepatocellular carcinomas in patients with no previous treatment, 26 treated hepatocellular carcinomas, and 38 hemangiomas. The vascular depiction of power Doppler sonography was compared with that obtained in the early phase of CO(2)-enhanced sonography. The results of angiography were also recorded for comparison. RESULTS: In the hepatocellular carcinomas, power Doppler sonography was the same as CO(2)-enhanced sonography in 18 (62%) of 29 tumors, was inferior to CO(2)-enhanced sonography in nine (31%) of 29 tumors, and was superior to CO(2)-enhanced sonography in two (7%) of 29 tumors. In the treated hepatocellular carcinomas, power Doppler sonography was the same as CO(2)-enhanced sonography in 15 (58%) of 26 tumors and was inferior in 11 (42%) of 26 tumors. In hemangiomas, the same vascularity was found in both studies in 15 (39%) of 38 tumors, CO(2)-enhanced sonography was superior in 22 (58%) of 38 tumors, and power Doppler sonography was superior in one (3%) of 38 tumors. As a whole, 45% of the 93 tumors showed better vascular depiction on CO(2)-enhanced sonography. However, 19.4% of tumors were hypovascular using power Doppler sonography but hypervascular using CO(2)-enhanced sonography. CONCLUSION: Power Doppler sonography is a useful technique for screening hepatic tumor vascularity. CO(2)-enhanced sonography is superior to power Doppler sonography in depicting tumor vascularity in treated hepatocellular carcinomas and in hemangiomas, especially small hemangiomas.

Adult↗

Power spectral analysis of heart rate variation in diabetic patients with neuropathic foot ulceration.

OBJECTIVE: To evaluate the relationship between diabetic autonomic neuropathy and diabetic neuropathic foot ulceration, we used power spectral analysis (PSA) of heart rate variation, which provides the accurate simultaneous quantification of parasympathetic and sympathetic activities, to assess autonomic function in diabetic patients. RESEARCH DESIGN AND METHODS: We studied 55 NIDDM patients including 10 diabetic patients without neuropathy, 23 diabetic patients with neuropathy and no history of foot ulceration, and 22 diabetic patients with neuropathic foot ulceration. We performed PSA of 100 R-R intervals at rest and analyzed the results by fast Fourier transformation. RESULTS: The low frequency (LF) power, which reflects sympathetic activity, and the high frequency (HF) power, which reflects parasympathetic (vagal) activity, were inversely correlated with the duration of diabetes and the fasting plasma glucose (FPG) levels. By multiple regression analysis, the FPG remained with significant influence on both LF and HF powers. The LF and HF powers were positively correlated with motor nerve conduction velocity (MCV) and sensory nerve conduction velocity (SCV) in the upper and lower limbs and the coefficient of variation of R-R intervals. The LF and HF powers were significantly reduced in patients with neuropathy and patients with foot ulceration compared with patients without neuropathy. Although the median MCV and SCV were similar between diabetic patients with neuropathy and patients with foot ulceration, both the LF and HF powers were significantly decreased in patients with foot ulceration compared with patients with neuropathy. There was no difference in the value of the LF:HF ratio, an index of sympathovagal balance, among three subgroups. We observed a positive correlation between LF and HF power in all subjects; however, the LF and HF powers were not correlated in the subgroups of patients with foot ulceration. CONCLUSIONS: These results showed that diabetic patients with neuropathic foot ulceration have a greater impairment in spectral indexes of autonomic activity obtained by PSA than patients with neuropathy and no history of foot ulceration, whereas no difference was present in nerve conduction velocities.

Age Factors↗

The power of tests for bioequivalence in feed experiments with poultry.

Several studies have compared the feeding of genetically modified (GM) grains and conventional grains to poultry. The general conclusion has been that there were no significant differences detected in the biological performance of the birds (i.e., the grains were bioequivalent). However, the question has been posed whether the experimental designs used in the studies had sufficient statistical power to detect treatment differences. The power of tests can be used to determine the ability of an experimental design to detect treatment differences. The definition of statistical power is the probability of rejecting the null hypothesis when it is false and should be rejected. The complement of statistical power is the Type II error (beta). That is, accepting the null hypothesis that there is no difference in treatments when there is one. A priori power analysis can indicate the probability at which the sampling regimen or experiment can actually detect an effect if a difference exists. Post hoc power analysis indicates the sufficiency or the sample size needed for an experiment that has already been conducted. In the current study, the power of tests for experiments published in the literature where significant and nonsignificant differences were reported between control birds and birds fed new feed grains was examined. With some exceptions, the power of tests is rarely formally considered or mentioned in poultry research. The results of the survey of the literature showed, in general, low power of statistical tests for feeding experiments involving non-GM grains or in those cases when GM and non-GM grains were compared in poultry feeding experiments. These results suggest that care needs to be taken when designing experiments for bioequivalence of grains fed to poultry.

Animal Feed↗

[Electromyographic study on the external urethral sphincter of the male--power spectrum analysis with fast Fourier transformation].

In 23 male patients, the electrical activity of external urethral sphincter muscle was sampled before examination of cystometry (Rest), at first desire to void (FDV), maximum desire to void (MDV) and during urination (Void) by means of electromyography (EMG). Sampling time of each event was 2400 msec. The electrical activity was amplified with a lower limiting frequency of 20 Hz and an upper limiting frequency of 10000 Hz, and recorded on magneto-optical desk. Spectra were obtained using a Hamming window. The action potential of the muscle was quantitatively analyzed and power spectrum of the needle EMGs were analyzed from the magneto-optical disk by a spectrum analyzer using fast Fourier transformation (FFT, Sande-Tukey method). From each power spectrum, mean power frequency (MPF) was obtained from a calculator connected to the spectrum analyzer. Twenty three patients were divided into three groups as follows: 8 patients without any neurological abnormality (normal group), 7 patients with neurogenic bladder showing detrusor-sphincter-dyssynergia (DSD+ group) and 8 patients with neurogenic bladder without detrusor-sphincter-dyssynergia (DSD- group). The results obtained were as follows: 1) The motor unit potentials at Rest had the mean amplitude of 210 +/- 59.4 microV, 329.3 +/- 157.1 microV and 177.6 +/- 132.8 microV in normal group, DSD+ group and DSD- group, respectively. The mean duration were 4.3 +/- 0.2 msec, 5.9 +/- 1.9 msec, and 7.3 +/- 4.5 msec., respectively. The mean phases were 2.8 +/- 0.6, 2.8 +/- 0.5 and 2.5 +/- 0.3, respectively. Statistically there was no difference in amplitude, duration and phase among three groups. 2) In normal group, the power over than -20 dB was distributed from 150 to 220 Hz windows at Rest and FDV. The needle EMGs at MDV showed interference pattern and the power increased over -20 dB in all windows. The power of high frequency area relatively increased. The action potential of the muscle disappeared during urination and the power also disappeared. The average MPF was 103 Hz, 102 Hz, 150 Hz and 98 Hz at Rest, FDV, MDV and Void, respectively. 3) In DSD+ group, the needle EMGs showed interference pattern in MDV and Void, and the power increased only in low frequency area. The average MPF was 104 Hz, 105 Hz, 114 Hz and 120 Hz at Rest, FDV, MDV and Void, respectively. 4) Because of damage to nerves, the action potential of the muscle was difficult to obtain from 3 patients of DSD- group, and the power was not demonstrated.(ABSTRACT TRUNCATED AT 400 WORDS)

Adult↗

Human muscle power generating capability during cycling at different pedalling rates.

The effect of different pedalling rates (40, 60, 80, 100 and 120 rev min-1) on power generating capability, oxygen uptake (O2) and blood lactate concentration [La]b during incremental tests was studied in seven subjects. No significant differences in O2,max were found (mean +/- S.D., 5.31 +/- 0.13 l min-1). The final external power output delivered to the ergometer during incremental tests (PI,max) was not significantly different when cycling at 60, 80 or 100 rev min-1 (366 +/- 5 W). A significant decrease in PI,max of 60 W was observed at 40 and 120 rev min-1 compared with 60 and 100 rev min-1, respectively (P < 0.01). At 120 rev min-1 there was also a pronounced upward shift of the O2-power output (O2-P) relationship. At 50 W O2 between 80 and 100 rev min-1 amounted to +0.43 l min-1 but to +0.87 l min-1 between 100 and 120 rev min-1. The power output corresponding to 2 and 4 mmol l-1 blood lactate concentration (P[La]2 and P[La]4 ) was also significantly lower (> 50 W) at 120 rev min-1 (P < 0.01) while pedalling at 40, 60, 80 and 100 rev min-1 showed no significant difference. The maximal peak power output (PM, max) during 10 s sprints increased with pedalling rate up to 100 rev min-1. Our study indicates that with increasing pedalling rate the reserves in power generating capability increase, as illustrated by the PI,max/PM,max ratio (54.8, 44.8, 38.1, 34.6, 29.2%), the P[La]4/PM,max ratio (50.4, 38.9, 31.0, 27.7, 22.9%) and the P[La]2/PM,max ratio (42.8, 33.5, 25.6, 23.1, 15.6%) increases. Taking into consideration the O2,max, the PI,max and the reserve in power generating capability we concluded that choosing a high pedalling rate when performing high intensity cycling exercise may be beneficial since it provides greater reserve in power generating capability and this may be advantageous to the muscle in terms of resisting fatigue. However, beyond 100 rev min-1 there is a decrease in external power that can be delivered for an given O2 with an associated earlier onset of metabolic acidosis and clearly this will be disadvantageous for sustained high intensity exercise.

Adult↗

Human muscle power output during upper- and lower-body exercises.

The purpose of this study was to evaluate the use of traditional resistance training equipment in the measurement of muscular power. This was accomplished by measuring the velocity of movement through a measured distance during maximal effort lifts using a Smith rack. The reliability of the method was established using 10 male volunteers who performed both bench press and squat exercises in a Smith rack. Maximal power output was determined at 30, 40, 50, 60, 70, 80, and 90% of the subject's 1 repetition maximum (1RM). Test-retest power values were not statistically different. Another 15 male volunteers who had previous muscle biopsy data from the vastus lateralis muscle performed the same maximal power output evaluation. There were no significant relationships between peak power outputs and fiber-type expressions when linear regressions were performed. The power curve produced by graphing power output vs. the percentage of 1RM indicates that peak power output occurs between 50 and 70% of 1RM for the squat and between 40 and 60% of 1RM for the bench press. These data indicate that this method of evaluation of muscle power is reliable, although it is not predictive of muscle fiber-type percentages.

Adult↗

[Assessment of pre-term uterine contractions by characterization of the power spectra of abdominal surface potentials (ASP)].

The prognosis of pre-term labor in the absence of complications such as PROM is dependent on the strength of the uterine contractions, which are dependent on the sensitivity of the myometrium, expressed in terms of bio-electric potentials. Our electromyography were obtained from pregnant ewes, and these were correlated with abdominal surface potentials (ASP) obtained from human volunteers, to see if impending premature labor could be detected and the prognosis predicted. 1) The EMG tracings obtained from pregnant ewes were submitted to a power spectrum analysis. 2) EMG tracings revealed an increase in power output with the advance of labor, but power spectra varied with the stage of labor. 3) Uterine contractions not leading to cervical ripening had a low power output with a low frequency range. 4) Ewes in true labor had EMG's at a high power output of low frequency waves. 5) Ewes in pre-term labor leading to cervical ripening had power outputs similar to ewes in true labor, but the power spectra of the former were wider in range. 6) ASP tracing revealed an increasing power output with increasing uterine contractile activity and power spectra correlated well with the EMGs obtained from ewes. In conclusion, since ASP findings were in good correlation with EMGs obtained directly from the myometrium, we hope that this method may be developed into a practical non-invasive method for detecting and assessing uterine contractions.

Abdomen↗

[Effects of power-frequency magnetic fields exposure on phosphorylation and enzymatic activity of stress-activated protein kinase and its upstream kinase].

OBJECTIVE: To study the effects of 50 Hz power-frequency magnetic fields on signal transduction pathway of stress-activated protein kinase(SAPK), and explore the cellular signal transduction mechanism of the biological effects induced by power-frequency magnetic fields. METHODS: Chinese hamster lung(CHL) cell line was exposed to power-frequency magnetic fields with two intensities for different exposure durations. The cytoplasmic protein was extracted and the phosphorylated portion of SAPK and SEK1/MKK4 was measured with Western blotting analysis. The SAPK enzymatic activity was measured by the solid-phase kinase assay in cells exposed to power-frequency magnetic fields for 15 min. RESULTS: Both 0.4 mT and 0.8 mT power-frequency magnetic fields could enhance the phosphorylation of SAPK in a time-relative course manner, and reached the maximum extent at 15 min, with an increase of 20% and 17% respectively. The solid-phase kinase assay showed that the enzymatic activities of SAPK were also increased, which were 2.9 +/- 0.4 and 2.1 +/- 0.9 times of control respectively. However, the duration of SAPK phosphorylation induced by 0.8 mT was longer than that of 0.4 mT, while the duration and extent of SAPK dephosphorylation was remarkably shorter than that of 0.4 mT. The power-frequency magnetic fields under equal conditions could not phosphorylate(activate) the SEK1/MKK4. CONCLUSION: Power-frequency magnetic fields could activate the SAPK, but not SEK1/MKK4. It is suggested that power-frequency magnetic fields may activate SAPK signal transduction pathway through a kinase other than SEK1/MKK4. The activation mechanism of SAPK of power-frequency magnetic fields needs to be identified in more detail.

Animals↗