[Formalization of a choice procedure in dosimetric planning of tele-irradiation in gamma-ray therapy].

The authors proposed a model of assessment of the usefulness of any mode of distant irradiation in gamma-beam therapy chosen for the treatment of each individual patient. The criteria were defined, functions of the calculation of the criteria of assessment of dose field quality were defined, functions for the calculation of the significance of the criteria presented for each individual patient by a radiologist, was given. The use of a plotted model to compare two dosimetric programs of irradiation of lung cancer was described.

Humans↗

[Combination radiochemotherapy in the limited-disease stage of small-cell bronchial carcinoma. Results following high-dosage radiotherapy].

From 1980 through 1984, 72 patients with small cell bronchial carcinomas were treated by radiotherapy. Twenty-one patients who were in a limited disease stage (LD) received chemotherapy according to the ACO scheme and high-dose radiotherapy with 50 Gy. These patients had a complete remission rate of 67% and a partial remission rate of 33%. The median control period was 37 months. At the time of diagnosis, patients had a median survival time of ten months (six to 36 months). A recurrence in the irradiated region was seen in none of the patients, however, 14% of patients developed a recurrence beyond the irradiation field. The results are compared to literature and discussed.

Adult↗

Random search algorithm (RONSC) for optimization of radiation therapy with both physical and biological end points and constraints.

A new algorithm for the optimization of 3-dimensional radiotherapy plans is presented. The RONSC algorithm (Random Optimization with Non-linear Score functions and Constraints) is based on the idea of random search in the space of feasible solutions. RONSC takes advantage of some specific properties of the dose distribution and derivable information such as dose-volume histograms and calculated estimates of tumor control and normal tissue complication probabilities. The performance of the algorithm for clinical and test cases is discussed and compared with the performance of the simulated annealing algorithm, which is also based on the idea of random search.

Algorithms↗

Digital tumor fluoroscopy (DTF)--a new direct imaging system in the therapy planning for brain tumors.

Digital Tumor Fluoroscopy is an expanded x-ray video chain optimized to iodine contrast with an extended Gy scale up to 64000 Gy values. Series of pictures are taken before and after injection of contrast medium. With the most recent unit, up to ten images can be taken and stored. The microprogrammable processor allows the subtraction of images recorded at any moment of the examination. Dynamic views of the distribution of contrast medium in the intravasal and extravasal spaces of brain and tumor tissue are gained by the subtraction of stored images. Tumors can be differentiated by studying the storage and drainage behavior of the contrast medium during the period of examination. Meningiomas store contrast medium very intensively during the whole time of investigation, whereas astrocytomas grade 2-3 pick it up less strongly at the beginning and release it within 2 min. Glioblastomas show a massive but delayed accumulation of contrast medium and a decreased flow-off-rate. In comparison with radiography and MR-imaging the most important advantage of Digital Tumor Fluoroscopy is that direct information on tumor localization is gained in relation to the skull-cap. This enables the radiotherapist to mark the treatment field directly on the skull. Therefore it is no longer necessary to calculate the tumor volume from several CT scans for localization. In radiotherapy Digital Tumor Fluoroscopy a unit combined with a simulator can replace CT planning. This would help overcome the disadvantages arising from the lack of a collimating system, and the inaccuracies which result from completely different geometric relationships between a CT unit and a therapy machine.

Astrocytoma↗

High-performance computing in radiation cancer treatment.

In 1989 a consortium of the Radiation Oncology and Computer Science Departments at the University of North Carolina, BellSouth Corporation, GTE, and the MCNC was formed in response to the high-speed network initiative proposed by the National Science Foundation and the Defense Advanced Research Projects Agency. One of the purposes of this effort has been to demonstrate that applications exist that require gigabit per second networks. Our consortium, known as VISTAnet, proposed to use real-time radiation therapy treatment planning as the application that would require the use of a gigabit network. The plan was to develop a system that could rapidly calculate and display a three-dimensional radiation dose distribution for any configuration of radiation beams. The gigabit network would be used to tie the dose calculations done with the Cray Y-MP at the Research Triangle to the graphics engine at the Department of Computer Science (Pixel-Planes 5) and the medical workstation at Radiation Oncology. The system would then provide the radiation physician with the capability of considering hundreds of potential treatment plans, instead of the usual two or three, with the goal of arriving at a highly optimized plan within a few minutes.

Computer Communication Networks↗

Computer-aided medical decision making in radiotherapy.

Radiotherapy departments are becoming sophisticated in working with computers for isodose computations, treatment machine verifications and administrative and medical records. The next step lies in computer-assisted medical decision making. The logic for a patient's diagnostic work-up and treatment protocol can be stored in a computer. It can then be used as an aid in making the diagnosis, in prescribing the treatment and for quality control. For patients who fit established protocols the computer can select and list treatment using the logic of that protocol. Such a system has been implemented for the postoperative radiotherapy of breast cancer on a trial basis. Its potential usefulness is illustrated by results in 25 consecutive patients. Physician acceptance and costs of the program are under investigation.

Breast Neoplasms↗

Bayesian statistics: a guided tour.

An overview of Bayesian statistical decision theory is presented in the tutorial spirit. A section on fundamental principles is followed by selected applications of the Bayesian approach to parameter estimation, pattern recognition, image processing, computer-aided medical diagnosis, optimal diagnostic test selection, and radiotherapy treatment planning.

Decision Making↗

Investigating the potential of three-dimensional treatment planning.

3-D treatment planning has received a great deal of attention in the radiation therapy community over the last several years. This new technology makes use of the continuous improvements in computer hardware and graphics capabilities, along with major improvements in treatment planning software, to provide a fully three dimensional simulation of the patient, radiation beams, and dose distributions which are used for radiation therapy of various cancers. With these capabilities, the physician and treatment planner may now optimize the radiation beams used to treat the patient much more effectively than in the past, when only a limited description of the patient, beams, and doses was available. This paper describes several of the new capabilities of these 3-D planning systems, some research studies which are currently being performed to evaluate the usefulness of the new technology, and finally some of the costs associated with its implementation.

Computer Simulation↗

[Ultrasound in tumor diagnostics and treatment planning (author's transl)].

The fundamental requirements of irradiation planning are discussed delimitating the minimum and maximum demands of planning. Different possibilities to represent the topographic relations within the irradiation plane of the patient's cross-section are described. The computer-assisted system for irradiation planning, installed at our hospital by means of MAT construction, is discussed. A pathway is shown which leads to individual treatment planning and considers dosimetrically the actual conditions of the patient who will undergo radiation therapy. The possibilities and limits of ultrasonic cross-sectional imaging are demonstrated.

Diagnosis, Computer-Assisted↗

An interactive beam-weight optimization tool for three-dimensional radiotherapy treatment planning.

A computer software tool has been developed to aid the treatment planner in selecting beam weights for three-dimensional radiotherapy treatment planning. The program consists of a feasibility search algorithm embedded in an interactive, user-friendly driving program. The feasibility search algorithm is based on the iterative relaxation algorithm of Cimmino [La Ricerca Scientifica, Vol. I, pp. 326-333 (1938)] as applied to the radiotherapy inverse problem by Altschuler et al. [Med. Phys. 13, 590 (1986)]. Relative importances of structures based upon clinical considerations can be incorporated into the algorithm. In order to speed convergence, the relaxation parameter is made to vary, with its value based upon a measure of deviation from feasibility. The interactive driving program is designed so that the treatment planner can make reasonable judgments regarding the acceptability of a plan in the event that the dose constraints yield no feasible solution. An example of the use of this program applied to a problem in three-dimensional radiotherapy treatment planning is illustrated.

Algorithms↗

[Technical aspects of proton irradiation of intraocular tumors].

The paper is concerned with the description of some technical aspects of irradiation of intraocular melanomas of the preequatorial and retroequatorial localizations with a proton beam on a synchrotron at the Institute of Theoretical and Experimental Physics. Potentialities of a program of design of irradiation of intraocular tumors were considered. The parameters of an optimized plan of irradiation were determined by analysis of computer-simulated dose topographic and anatomic situations at different variants of irradiation. Reproducibility of an optimized plan of irradiation was no worse than 1 mm.

Eye Neoplasms↗

Computer-assisted 3D-reconstruction and statistics of the limbic system. 1. Computer-assisted 3D-reconstruction of the hippocampal formation, the fornix, and the mamillary bodies.

The hippocampal formation of eight perfusion-fixed human brains was examined using new methods according to stereotactic and morphometric principles (macrovibratome and computer-aided 3D reconstruction). The reconstructions form part of a neuroanatomical reference system (NeuRef). This reference system allows for 3D visualisation of the brain and its components on a computer graphic workstation, as well as for the presentation of the union set based on a neuroanatomical structure taken from this sample of brains. This retrievable knowledge of neurofunctional systems is important for the preoperative planning of neurosurgeons and the adjustment of radiotherapy.

Adult↗

3-D superposition for radiotherapy treatment planning using fast Fourier transforms.

Currently used radiotherapy treatment planning algorithms based on effective path length or scatter function methods do not model electron ranging from photon interaction sites. The superposition (or convolution) technique does model this effect, which is especially important at higher (linear accelerator) energies since the electron range is significant. Another advantage of this method is that it is conceptually simple and models the physical processes directly, rather than using empirically derived methods. A major disadvantage of superposition lies in the large amount of computer time required to generate a plan, especially in three dimensions. To help solve this problem, superposition using an invariant dose spread array (kernel) can be achieved by performing a convolution in Fourier space using fast Fourier transforms (FFTs). A method for 3 dimensional calculation of dose using FFTs is presented. Dose spread arrays are calculated using the EGS Monte Carlo code, and convolved with the TERMA (total energy released per unit mass). In both cases a 10 MV nominal beam energy is modelled by a 10 component spectrum, which is compared to the result obtained using monochromatic energy only (3.0 MeV at the surface). The FFT technique is shown to be significantly faster than standard convolution for medium to large TERMA and dose spread array sizes. The method is shown to be highly accurate for small fields in homogeneous media. For larger fields the central axis depth dose is accurate but the profile shape in the penumbral region becomes slightly distorted. This is because photons incident near the beam edges are not parallel to the cartesian coordinate system used as the convolution framework. However, this effect is sufficiently small to indicate that the convolution method is suitable for use in routine treatment planning.

Fourier Analysis↗

Testing a 3-D radiation therapy planning program.

This report describes a systematic effort to test all functions of a large 3-D radiation therapy planning program, including graphics and user interaction. Previous studies in quality assurance for radiation therapy programs do not adequately address the problem of programming errors. They compare dose estimates calculated by planning programs to actual doses measured in phantoms, so they cannot distinguish programming errors from measurement errors or physical unsoundness of the beam model. Moreover, they fail to exercise graphics and user interaction functions. This report describes a different methodology: test cases are derived from the program specification, results are calculated by an independent technique, and compared to program output. Derivation of test cases is described in detail. Effectiveness of testing is assessed by reporting the number of errors revealed by testing and comparing to the number of errors discovered during routine use in five successive program versions. The size of the test set is related to the total program size, and the effort devoted to deriving and performing tests is compared to the total program development effort. We conclude that systematic testing can reveal errors that are not found by informal testing, routine program use, or comparison with measurements. However, additional errors remain that are only discovered during use. This study suggests that a typical large planning system may include more than 100 errors when it is released for clinical use. Methods for increasing testing effectiveness are recommended.

Radiotherapy, Computer-Assisted↗

[Three-dimensional reconstructions in neuroanatomy].

Computer-aided 3D reconstructions of neurofunctional systems and structures are generated as a reference for neuroimaging (CT, MRI, PET). The clinical application of these 3D reconstructions requires a coordinate system and conditions resembling the intravital neuroanatomy as far as possible. In this paper the neuroanatomical Reference System (NeuRef) of the Department of Neuroanatomy of Hannover Medical School is presented. This consists of methods to record brain structures from serial sections with minimal error (less than 1 mm) and to display 3D brain models derived from such a data base. In addition, NeuRef is able to generate sections through, for instance, the visual and pyramidal system and to transfer these data onto a corresponding CT image. Therefore, this method can serve as a diagnostic aid in neuroradiology, in operation planning, and radiotherapy. It can also be used in PACS.

Brain↗

New methods of imaging in diagnostic radiology Sylvanus Thompson Memorial Lecture.

A brief history of the recent developments in computer-assisted tomography (CAT) is presented. The development of whole-body scanners from the basic brain scanner, the trend towards higher-speed scanners using multiple detectors in a fan-type geometry, and some of the unsolved problems related to CAT scanners are discussed, as well as the potential use of whole-body scanning in radiotherapy treatment planning and in radiobiology. A review of recent developments in electrostatic imaging is presented and a new method of imaging called ionography is described in detail. It is shown how a single exposure can be used to produce a number of copies, each with a different amount of edge contrast, under the control of the radiologist. Further, it is shown how this can be done using a closed system so that the ionography chamber never needs to be opened. Some of the recent commercial developments in this field are described. It is suggested that in the future radiology departments may be replaced by departments of imaging, which will include all ways of obtaining diagnostic information and where such a department would be problem oriented rather than technique oriented. The need for basic scientific support by a medical physics and engineering group in such a department is emphasized.

Electrons↗

True three-dimensional dose computations for megavoltage x-ray therapy: a role for the superposition principle.

The objective of radiation therapy is to concentrate a prescribed radiation dose accurately within a target volume in the patient. Major advances in imaging technology have greatly improved our ability to plan radiation treatments in three dimensions (3D) and to verify the treatment geometrically, but there is a concomitant need to improve dosimetric accuracy. It has been recommended that radiation doses should be computed with an accuracy of 3% within the target volume and in radiosensitive normal tissues. We review the rationale behind this recommendation, and describe a new generation of 3D dose algorithms which are capable of achieving this goal. A true 3D dose calculation tracks primary and scattered radiations in 3D space while accounting for tissue inhomogeneities. In the past, dose distributions have been computed in a 2D transverse slice with the assumption that the anatomy of the patient dose not change abruptly in nearby slices. We demonstrate the importance of computing 3D scatter contributions to dose from photons and electrons correctly, and show the magnitude of dose errors caused by using traditional 2D methods. The Monte Carlo technique is the most general and rigorous approach since individual primary and secondary particle tracks are simulated. However, this approach is too time-consuming for clinical treatment planning. We review an approach that is based on the superposition principle and achieves a reasonable compromise between the speed of computation and accuracy in dose. In this approach, dose deposition is separated into two steps. Firstly, the attenuation of incident photons interacting in the absorber is computed to determine the total energy released in the material (TERMA). This quantity is treated as an impulse at each irradiated point. Secondly, the transport of energy by scattered photons and electrons is described by a point dose spread kernel. The dose distribution is the superposition of the kernels, weighted by the magnitude of the TERMA impulse for all interaction sites. In this review, we demonstrate the capabilities of the superposition method, particularly for situations of charged particle disequilibrium, and we report on the progress made by several research groups in adapting this method to clinical treatment planning. In the future, the superposition method will have a significant role in dose optimization for conformal irradiation techniques because of its close correspondence to image reconstruction by filtered back-projection.

Image Processing, Computer-Assisted↗