PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Solid Phase Microextraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 559 records · Page 31Linked to original sources

Development of gas chromatography-mass spectrometry with microwave distillation and simultaneous solid-phase microextraction for rapid determination of volatile constituents in ginger.

In this study, gas chromatography-mass spectrometry (GC-MS) following microwave distillation and solid-phase microextraction (MD-SPME) was developed for the analysis of essential oil compounds in fresh ginger. In the proposed method, the isolation, extraction and concentration of volatile components in ginger were carried out in one single step, using the MD-SPME technique, and the analytes on the SPME fiber were analyzed by GC-MS. Some parameters, including SPME fiber coating, microwave power and irradiation time, were optimized. The optimal experiment parameters obtained were: 65 microm PDMS/DVB SPME fiber, a microwave power of 400 W and an irradiation time of 2 min. To demonstrate its feasibility, MD-SPME was compared with conventional SPME for the extraction of essential oil compounds in fresh ginger. Using MD-SPME followed by GC-MS, 54 compounds were separated and identified in ginger, which mainly included geranial (5.25%), zingiberene (15.48%), beta-sesquiphellandrene (5.54%) and beta-phellandrene (22.84%), whereas only 39 compounds were separated and identified by conventional SPME followed by GC-MS. The relative standard deviation (R.S.D.) values of less than 10% show that the proposed method has good repeatability. The result show that MD-SPME, followed by GC-MS, is a simple, rapid, solvent-free method for the determination of volatile compounds in ginger.

Gas Chromatography-Mass Spectrometry↗

Separation and identification of aromatic acids in soil and the Everglades sediment samples using solid-phase microextraction followed by capillary zone electrophoresis.

The separation and identification of aromatic acids in soil and the Everglades sediment samples was carried out using solid-phase microextraction (SPME) followed by capillary zone electrophoresis (CZE). The soil and sediment samples were subject to a series of sample treatments including oxidative hydrolysis with molecular oxygen in a sodium hydroxide solution, acidification and filtration. The aromatic acids in the sample filtrate were extracted using SPME with a polyacrylate-coated fiber. The acids adsorbed on the fiber were subsequently desorbed in methanol. The desorbed acids were then separated by CZE. Several aromatic acids (e.g.. salicylic acid, p-coumaric acid, ferulic acid and vanillic acid) in both soil and sediment samples were separated, identified and quantified. The results of this study show that the combination of SPME with CZE is promising for environmental analysis.

Acids↗

On-fiber photodegradation after solid-phase microextraction of p,p'-DDT and two of its major photoproducts, p,p'-DDE and p,p'-DDD.

The potential of performing photochemical studies in solid phase microextraction (SPME) fibers, "photo-SPME", to study the photodegradation of p,p'-DDT and two of its major degradation products, p,p'-DDE and p,p'-DDD, is shown. Analyses were carried out by gas chromatography mass spectroscopy detection. DDT was extracted from aqueous solutions using five different commercial coatings. The fibers were then exposed to UV light emitted by a low-pressure mercury lamp. After 30 min of irradiation, the degradation of DDT only occurred in polydimethylsiloxane fibers. The on-fiber degradation kinetics of p,p'-DDT was studied from 2 to 60 min. A large number of photoproducts were generated and their kinetic behavior was studied. In order to clarify the possible photoreaction pathways for DDT, individual water solutions containing p,p'-DDD or p.p'-DDE were prepared and photo-SPME was performed for each compound at different irradiation times. On the basis of the photoproducts identified, some photodegradation pathways are proposed. Finally, aqueous photodegradation studies followed by SPME were performed and compared to the photo-SPME. This work will show the enormous potential of photo-SPME to perform photodegradation studies.

DDT↗

Headspace solid-phase microextraction analysis of volatile sulphides and disulphides in wine aroma.

Sulphur compounds (S-compounds) are important constituents of wine off-flavours. Headspace solid-phase microextraction (HS-SPME) combined with gas chromatography coupled to flame photometric detection (GC-FPD) was used to develop a suitable method to analyse volatile sulphides and disulphides. This is a very simple and fast technique which gives good reproducibility at microgram/l levels (relative standard deviations < 10%). The analytes were extracted from the headspace of the samples by using either polydimethylsiloxane or polyacrylate coated fused-silica fibers in an SPME unit. Then, the fiber was inserted into the injector of a gas chromatograph and the extracted S-compounds were thermally desorbed. The influence of different parameters, such as ionic strength, stirring, headspace volume, ethanol concentration, time and temperature of extraction, was studied. The extraction of the fibers varies considerably for the different sulphur compounds studied. The most volatile compounds were the least extracted by the coating fibers tested. The standard additions technique, applied to real samples, gave the recoveries > 94%. The detection limits range between 3 micrograms/l and 50 ng/l. The overall process was successfully applied to identify and quantify S-compounds in white and red wines.

Chromatography, Gas↗

Volatile fraction of milk: comparison between purge and trap and solid phase microextraction techniques.

The aim of this research was to validate the results obtained previously by purge and trap (PT) and to investigate the ability of solid phase microextraction (SPME), a more rapid and less expensive technique, to discriminate drinking milk subjected to different heat treatments (i.e., pasteurization, ultrahigh temperature, "in-bottle" sterilization) and produced at different factories. The data obtained by both methods were processed by multivariate statistical analysis. PT and SPME showed comparable repeatability, although with different performances for the yield of extraction, and allowed the three milk categories to be distinguished. Within the chemical class of methyl ketones, 2-heptanone was found to be the most discriminating compound, and the possibility of using the concentration of this volatile as a marker for heat treatment was investigated.

Adsorption↗

Measurement of gas-liquid partition coefficient and headspace concentration profiles of perfume materials by solid-phase microextraction and capillary gas chromatography-mass spectrometry

An empirical model describing the relationship between the partition coefficients (K) of perfume materials in the solid-phase microextraction (SPME) fiber stationary phase and the Linearly Temperature Programmed Retention Index (LTPRI) is obtained. This is established using a mixture of eleven selected fragrance materials spiked in mineral oil at different concentration levels to simulate liquid laundry detergent matrices. Headspace concentrations of the materials are measured using both static headspace and SPME-gas chromatography analysis. The empirical model is tested by measuring the K values for fourteen perfume materials experimentally. Three of the calculated K values are within 2-19% of the measured K value, and the other eleven calculated K values are within 22-59%. This range of deviation is understandable because a diverse mixture was used to cover most chemical functionalities in order to make the model generally applicable. Better prediction accuracy is expected when a model is established using a specific category of compounds, such as hydrocarbons or aromatics. The use of this method to estimate distribution constants of fragrance materials in liquid matrices is demonstrated. The headspace SPME using the established relationship between the gas-liquid partition coefficient and the LTPRI is applied to measure the headspace concentration of fragrances. It is demonstrated that this approach can be used to monitor the headspace perfume profiles over consumer laundry and cleaning products. This method can provide high sample throughput, reproducibility, simplicity, and accuracy for many applications for screening major fragrance materials over consumer products. The approach demonstrated here can be used to translate headspace SPME results into true static headspace concentration profiles. This translation is critical for obtaining the gas-phase composition by correcting for the inherent differential partitioning of analytes into the fiber stationary phase.

Journal Article↗

High operationally stable sol-gel diglycidyloxycalix[4]arene fiber for solid-phase microextraction of propranolol in human urine.

A simple, sensitive, and accurate method for the determination of propranolol in human urine has been developed based on solid-phase microextraction (SPME) followed by GC-flame ionization detection (FID). The sol-gel 5,11,17,23-tetra-tert-butyl-25,27-dihydroxy-26,28-diglycidyloxycalix[4]arene/hydroxy-terminated silicone oil (diglycidyloxy-C[4]/OH-TSO) fiber was prepared to accommodate to the harsh extraction conditions. It possesses excellent alkali-proof ability and retains its extraction characteristics intact even after treatment with highly alkaline (4 mol/L) NaOH solution. Direct chemical bonding of the coating to the fiber surface provides it with excellent solvent resistance and the introduction of calixarene enhances its thermal stability. The newly developed sol-gel calixarene coating was effectively used for the extraction of propranolol in human urine. No interference with the determination of propranolol was observed from the urine components. Standard curves were linear in the range 50-5000 microg/L for headspace-SPME (HS-SPME) and 25-25000 microg/L for direct-SPME (Dir-SPME) with correlation coefficients better than 0.9999. The detection limit was 0.275 microg/L for HS-SPME and 0.193 microg/L for Dir-SPME. The method was validated using standard addition methodology and recovery values were between 91.4 and 117% for both the sampling modes with the RSDs less than 6% at different concentration levels in the linear ranges. The results obtained by both the sampling modes were feasible, and no significant differences between them regarding accuracy, precision, and detection limits were seen.

Calixarenes↗

Headspace-solid-phase microextraction fast GC in combination with principal component analysis as a tool to classify different chemotypes of chamomile flower-heads (Matricaria recutita l.).

Headspace-solid-phase microextraction gas chromatography-principal component analysis (HS-SPME GC-PCA) is proposed as a complementary or alternative method to essential oil (EO) GC-PCA in order to discriminate between flower-heads of chamomile of different chemotypes. Ninety-two EOs and the headspaces sampled by HS-SPME of the corresponding chamomile flower-heads were examined by conventional GC and fast GC (F-GC) and the results submitted to statistical analysis by PCA. HS-SPME F-GC-PCA showed itself to be a rapid technique by which to distinguish chamomile flower-head chemotypes a produced results in agreement with the accepted EO classification. Using this method, the analysis time was reduced from at least 4.5 h with EO conventional GC to less than 1 h with HS-SPME F-GC. This approach can thus successfully be used as an analytical decision maker in order to reduce the number of time-consuming EO conventional GC analyses by limiting them to those samples that cannot unequivocally be classified. The EO conventional GC and HS-SPME F-GC results of PCA were very uniform, but they did not provide quantitative correlations between the components as determined by the two methods. A different statistical approach and a larger number of samples will be needed in order to correlate components in the headspace sampled by SPME and those in the corresponding EO quantitatively through a function.

Chromatography, Gas↗

Solid-phase microextraction combined with surface-enhanced laser desorption/ionization introduction for ion mobility spectrometry and mass spectrometry using polypyrrole coatings.

The successful application of polypyrrole (PPY) solid-phase microextraction (SPME) coatings as both an extraction phase and a surface to enhance laser desorption/ionization (SELDI) of analytes is reported. This SPME/SELDI fiber integrates sample preparation and sample introduction on the tip of a coated optical fiber, as well as acting as the transmission medium for the UV laser light. Using ion mobility spectrometry (IMS) detection, the signal intensity was examined as a function of extraction surface area and concentration of analyte. The linear relationship between concentration and signal intensity shows potential applicability of this detection method for quantitative analysis. Extraction time profiles for the fiber, using tetraoctylammonium bromide as test analyte, illustrated that equilibrium can be reached in less than one minute. To investigate the performance of the PPY coating, the laser desorption profile was studied. The fiber was also tested using a quadrupole time-of-flight (Q-TOF) mass spectrometer with leucine enkephalin as test analyte. Since no matrix was used, mass spectra free from matrix background were obtained. This novel SPME/SELDI fiber is easy to manufacture, and is suitable for studying low-mass analytes because of the intrinsic low background. These findings suggest that other types of conductive polymers could also be used as an extraction phase and surface to enhance laser desorption/ionization in mass spectrometry.

Journal Article↗

Speciation of butyltin compounds in marine sediments with headspace solid phase microextraction and gas chromatography mass spectrometry.

A method for the determination of organotin compounds (monobutyl = MBT, dibutyl = DBT, and tributyltin = TBT) in marine sediments by headspace Solid Phase Microextraction (SPME) has been developed. The analytical procedure involved 1) extraction of TBT, DBT and MBT from sediments with HCl and methanol mixture, 2) in situ derivatization with sodium tetraethylborate and 3) headspace SPME extraction using a fiber coated with poly(dimethylsiloxane). The derivatized organotin compounds were desorbed into the splitless injector and simultaneously analyzed by gas chromatography - mass spectrometry. The analytical method was optimized with respect to derivatization reaction and extraction conditions. The detection limits obtained for MBT, DBT and TBT ranged from 730 to 969 pg/g as Sn dry weight. Linear calibration curves were obtained for all analytes in the range of 30-1000 ng/L as Sn. Analysis of a standard reference sediment (CRM 462) demonstrates the suitability of this method for the determination of butyltin compounds in marine sediments. The application to the determination of TBT, DBT and MBT in a coastal marine sediment is shown.

Gas Chromatography-Mass Spectrometry↗

Rapid analysis of amphetamines in blood using head space-solid phase microextraction and selected ion monitoring.

A simple and rapid method for analysis of methamphetamine (MA) and amphetamine (AP) in blood was developed using head space-solid phase microextraction (HS-SPME) and gas chromatography-mass spectrometry/electron impact ionization-selected ion monitoring (GC-MS/EI-SIM). A vial containing a blood sample, sodium hydroxide, and pentadeuterated methamphetamine as an internal standard, was heated at 80 degrees C for 20 min. The extraction fiber of the SPME was exposed for 5 min in the head space of the vial. First, heptafluorobutyric anhydride solution was injected into the injection port of the GC-MS to make heptafluorobutyramide (HFB) derivatives of amphetamines, and compounds absorbed on the fiber were detached by exposing the fiber in the injection port. Straight calibration curves of MA and AP were obtained from 0.01 to 2 micrograms/g in blood, respectively. No interfering substances were found, and the time for analysis was 30 min for one sample.

Adult↗

Comparison of solid-phase microextraction and stir bar sorptive extraction for determining six organophosphorus insecticides in honey by liquid chromatography-mass spectrometry.

Two approaches based on sorptive extraction, solid-phase microextraction (SPME) and stir bar sorptive extraction (SBSE), in combination with liquid chromatography (LC)-atmospheric pressure chemical ionization mass spectrometry (MS) have been assayed for analyzing chlorpyriphos methyl, diazinon, fonofos, phenthoate, phosalone, and pirimiphos ethyl in honey. In both, SPME and SBSE, enrichment was performed using a poly(dimethylsiloxane) coating. Significant parameters affecting sorption process such as sample volume, sorption and desorption times, ionic strength, elution solvent, and dilution (water/honey) proportion were optimized and discussed. Performance of both methods has been compared through the determination of linearity, extraction efficiencies, and limits of quantification. Relative standard deviations for the studied compounds were from 3 to 10% by SPME and from 5 to 9% by SBSE. Both methods were linear in a range of at least two orders of magnitude, and the limits of quantification reached ranging from 0.04 to 0.4 mg kg(-1) by SBSE, and from 0.8 to 2 mg kg(-1) by SPME. The two procedures were applied for analyzing 15 commercial honeys of different botanical origin. SPME and SBSE in combination with LC-MS enabled a rapid and simple determination of organophosphorus pesticides in honey. SBSE showed higher concentration capability (large quantities of sample can be handled) and greater accuracy (between 5 and 20 times) and sensitivity (between 10 and 50 times) than SPME: thus, under equal conditions, SBSE is the recommended technique for pesticide analysis in honey.

Chromatography, Liquid↗

Application of solid-phase microextraction to virgin olive oil quality control.

Volatiles of olive oils from 'tree-picked', 'ground-picked' and both mixed olives were analysed by solid-phase microextraction and gas chromatography with flame ionisation detection (FID). Headspace sampling was carried out for 30min of fibre exposition at 40 degrees C of sampling temperature by the selected 74 microm polydimethylsiloxane/divinylbenzene (PDMS/DVB) fibre. Chromatographic data were analysed by principal components analysis (PCA) and then selected 14 compounds from x-loading of first principal component that provides a differentiation of oils accord its sensorial characterisation. Compounds such as 4-ethylphenol and styrene were identified by gas chromatography-mass spectrometry (GC-MS) in 'ground-picked' olive oils.

Chromatography, Gas↗

Use of solid-phase microextraction followed by on-column silylation for determining chlorinated bisphenol A in human plasma by gas chromatography-mass spectrometry.

In this study, a solid-phase microextraction (SPME) method based on poly(acrylate)-coated fibres has been developed for detection and quantification of chlorinated bisphenol A in human plasma due to the need for an assessment of human exposure to them. After desorption of the analytes for 7 min at 300 degrees C, they were directly derivatized in the GC injector port by injection of 2 microL of diluted bis(trimethylsilyl)trifluoroacetamide (BSTFA). The formation of trimethylsilylate derivatives improves the selectivity, sensitivity and performance of the chromatographic properties obtained when the analytes are directly separated. Quantification was carried out using single-ion monitoring (SIM). The respective chloroderivative molecular ions appear at 406, 440, 474 and 508 m/z; whereas the base peaks corresponding to a loss of a methyl group in all cases appear at 391, 425, 459 and 493 m/z for mono-, di-, tri- and tetrabisphenol A, respectively. Deuterated bisphenol A (BPA-d16) was used as an internal standard. The method was applied to the determination of Cl-BPA, Cl2-BPA, Cl3-BPA and Cl4-BPA at very low concentration levels in plasma. Recovery efficiencies were close to 100% in all cases.

Benzhydryl Compounds↗

Rapid determination of tramadol in human plasma by headspace solid-phase microextraction and capillary gas chromatography-mass spectrometry.

A simple, rapid and sensitive method for determination of tramadol in plasma samples was developed using headspace solid-phase microextraction (HS-SPME) and gas chromatography with mass spectrometry (GC-MS). The optimum conditions for the SPME procedure were: headspace extraction on a 65-microm polydimethylsiloxane/divinylbenzene (PDMS/DVB) fiber; 0.5 mL of plasma modified with 0.5 mL of sodium hydroxide (0.1 M); extraction temperature of 100 degrees C, with stirring at 2000 rpm for 30 min. The calibration curve showed linearity in the range of 1-400 ng mL(-1) with regression coefficient corresponding to 0.9986 and coefficient of the variation of the points of the calibration curve lower than 10%. The detection limit for tramadol in plasma was 0.2 ng mL(-1). The proposed method was successfully applied to determination of tramadol in human plasma samples from 10 healthy volunteers after a single oral administration.

Electrophoresis, Capillary↗

Determination of herbicides, including thermally labile phenylureas, by solid-phase microextraction and gas chromatography-mass spectrometry.

A method for the determination of 10 herbicides, including thermally unstable compounds, has been developed. The method uses solid-phase microextraction (SPME) with a polyacrylate fibre. Separation, identification and quantification were accomplished with gas chromatography-mass spectrometry. The herbicides chosen belong to different chemical groups and were alachlor, atrazine, chlorotoluron, diclofop, diflufenicam, ethofumesate, isoproturon, linuron, terbutryn and trifluralin. In the present work we studied the chromatographic behaviour of three phenylureas as a function of the medium and injection mode employed. The compounds generated as a function of the solvent used in direct injection of the phenylureas (ethyl acetate, methanol and methanol-water) and those obtained when injection was accomplished using the polyacrylate fibre were determined. The results allow us to propose a method for the determination of stable and thermally unstable herbicides as long as a preconcentration step involving SPME is carried out. In the proposed method, the limits of detection varied between 0.02 microg/l for ethofumesate and 0.11 microg/l for chlorotoluron. The method was applied to the determination of these herbicides in surface and ground water samples, performing quantification by standard addition calibration. The contents of chlorotoluron and atrazine found were significantly equal to those obtained using HPLC after a preconcentration stepwith styrene-divinylbenzene sorbents.

Gas Chromatography-Mass Spectrometry↗

Simple and simultaneous analysis of fenfluramine, amphetamine and methamphetamine in whole blood by gas chromatography-mass spectrometry after headspace-solid phase microextraction and derivatization.

A simple and sensitive method for the simultaneous analysis of fenfluramine, amphetamine and methamphetamine in whole blood was developed using a headspace-solid phase microextraction (SPME) and derivatization. A 0.5 g whole blood sample, 5 microl d(5)-methamphetamine (50 micrig/ml) as an internal standard, and 0.5 ml sodium hydroxide (1 M) were placed into a 12 ml vial, and sealed rapidly with a silicone septum and an aluminum cap. Immediately after the vial was heated to 70 degrees C in an aluminium block heater, the needle of the SPME device was inserted through the septum of the vial, and the extraction fiber was exposed in the headspace for 15 min. First, heptafluorobutyric anhydride was injected into the injection port of the GC-MS, and the compounds extracted by the fiber were then desorbed and derivatized simultaneously by exposing the fiber in the injection port. The calibration curves, using an internal standard method, demonstrated good linearity throughout the concentration range from 0.01 to 1.0 microg/g. The detection limits of this method were 5.0 ng/g for fenfluramine and methamphetamine, and 10 ng/g for amphetamine. No interferences were found, and the time for analysis was about 30 min for one sample. This method was applied to a suicide case in which the victim ingested fenfluramine. Fenfluramine was detected in the blood sample collected from the victim at the concentration of 7.7 microg/g.

Adult↗

Monoterpene composition of essential oil from peppermint (Mentha x piperita L.) with regard to leaf position using solid-phase microextraction and gas chromatography/mass spectrometry analysis.

Monoterpene compounds of leaf pairs and flowers of Mentha x piperita have been studied by direct headspace sampling using solid-phase microextraction coupled with gas chromatography/mass spectrometry (SPME-GC/MS). The content of peppermint-characteristic compounds such as menthol, menthyl acetate, and neomenthol increased in a basipetal direction (older plant parts), whereas menthone and isomenthone showed higher levels in the acropetal direction (younger plant parts). Higher levels of menthofuran were found in peppermint flowers in contrast to the leaves. SPME sampling resulted in relatively higher amounts of high-volatile monoterpenes and lower detection of less volatile compounds such as menthol and menthone, compared to solvent-based samples from essential oil distillation.

Gas Chromatography-Mass Spectrometry↗