Pulmonary embolism: diagnosis in 211 patients with use of selective pulmonary digital subtraction angiography with a flow-directed catheter.

PURPOSE: To evaluate image quality, safety, and clinical validity of selective, intraarterial, pulmonary digital subtraction angiography (DSA) with use of a flow-directed, balloon-tipped catheter in patients with suspected acute pulmonary embolism (PE). MATERIALS AND METHODS: Pulmonary DSA was performed in 211 patients with suspected PE. Subselective magnification series were obtained with nonionic contrast material. Clinical outcome of patients with a negative pulmonary DSA study was assessed by means of retrospective analysis of their medical records, with a minimum follow-up of 3 months. RESULTS: Among the 211 patients, DSA image quality was excellent in 129 (61.1%), adequate in 79 (37.4%), and poor in three (1.4%). Two angiograms (0.9%) were nondiagnostic. No complications occurred. Of 129 patients with negative DSA in whom anticoagulants were withheld, 16 died of disorders other than PE; one (0.9%, 95% confidence interval 0.0%, 4.2%) of 113 patients alive at 3 months returned after 3 weeks with possible PE. CONCLUSION: Pulmonary DSA with the flow-directed catheter is a safe procedure and provides good to excellent image quality. Anticoagulants can be withheld in patients suspected of having PE when pulmonary DSA results are negative.

Adult↗

Localization of small islet-cell tumors. Preoperative and intraoperative ultrasound, computed tomography, arteriography, digital subtraction angiography, and pancreatic venous sampling.

A total of 42 islet-cell tumors were examined between 1972 and 1984. Problems of localization were only encountered in 31 tumors less than 2 cm in diameter. Of 31 small tumors, 27 were correctly localized using a combined diagnostic approach: ultrasound was successful in 12/20 tumors, CT in 9/21, angiography in 20/31, intraarterial digital subtraction angiography in 1/2, and pancreatic venous sampling in 13/16. The smallest tumor found by ultrasound and CT was 7 mm in diameter. Intraoperative ultrasound demonstrated all 9 insulinomas examined. Currently, the most useful techniques for localizing small islet-cell tumors are ultrasound, CT, and angiography. CT is particularly useful for tumor staging. Improvement of non-invasive diagnostic techniques will obviate the need for transhepatic blood sampling.

Adenoma, Islet Cell↗

Evaluation of cerebral hemispheric contrast transit with intravenous digital subtraction angiography.

Thirty-six patients with varying degrees of stenosis of one internal carotid artery were studied using intravenous digital subtraction angiography, assessing relative hemispheric washin and washout of contrast medium. Ipsilateral delayed contrast transit was seen in 16 of 18 patients with a 70% or greater carotid artery stenosis. Decreased hemispheric peak contrast density was also seen in most of these patients. With further improvements in the computer program and faster imaging rates, intravenous digital subtraction angiography has the capability of providing valuable physiologic data along with anatomic information in patients with suspected cerebral ischemia.

Aged↗

Three dimensional digital subtraction angiography imaging of a ruptured aneurysm on the anterior communicating artery.

BACKGROUND: Although angiography is still gold standard for the diagnosis of cerebral aneurysms, false-negative angiograms in cases of subarachoid hemorrhage due to a rupture of an anterior communicating artery aneurysm have been previously reported. We now report a case of an anterior communicating aneurysm demonstrated by 3-dimensional digital angiography (3D-DSA) after a negative standard angiogram. CASE DESCRIPTION: A 41-year-old female was admitted in a comatose state. Computed tomography (CT) revealed intraventricular hemorrhage and a clot in the frontal interhemispheric fissure, suggestive of rupture of an anterior communicating artery aneurysm. Two days later, angiography was performed. Although standard 3-vessel angiogram with multiple views, using cross-compression on each carotid artery, was negative, 3D-DSA revealed an anterior communicating aneurysm. The aneurysm was successfully clipped based on the findings obtained from the 3D-DSA. The outcome was favorable, with mild memory disturbance. CONCLUSION: The standard angiogram sometimes fails to demonstrate aneurysms, especially those on the anterior communicating artery. In this case, 3D-DSA was useful for the diagnosis of the anterior communicating aneurysm which was not seen on standard angiogram.

Adult↗

Absolute volumetric coronary blood flow measurement with digital subtraction angiography.

The problems associated with visual interpretation of coronary arteriograms have been well-documented. There is a need for more physiologic means of assessing coronary artery stenosis during routine coronary arteriography. Volumetric coronary blood flow assessed as a function of time can be a valuable aid in the analysis of functional significance of arterial obstruction. A volumetric coronary blood flow measurement technique was investigated in a swine animal model using phase matched temporal subtraction images. The left anterior descending (LAD) coronary artery of swine animal models were instrumented with an ultrasound flow probe (US) and a vascular occluder producing stenosis. Contrast material injections (2-4 ml/sec for 3 sec) were made into the left coronary ostium during image acquisition. Phase-matched temporal subtraction (DSA) images were used to measure volumetric coronary blood flow in the LAD. In addition, a technique for automatic estimation of iodine calibration slope was also investigated. In 49 independent comparisons, the mean coronary blood flow (FPA) correlated extremely well with the mean US flow (FPA = 0.92US + 1.42 ml/min, r = 0.99, standard error of estimate (SEE) = 4.32 ml/min). Further more, the automatic iodine calibration technique was shown to be very accurate. In conclusion, accurate volumetric coronary blood flow measurements can be made before the onset of significant changes in coronary blood flow due to contrast injection.

Angiography, Digital Subtraction↗

Absolute phasic blood flow measurement in the brain using digital subtraction angiography.

RATIONALE AND OBJECTIVES: In this study, an angiographic method using first-pass distribution analysis was used for quantification of phasic volumetric blood flow. Studies were conducted in an angiographic perfusion phantom and in an animal model (rabbit) after intraarterial injection of contrast material. METHODS: Digital subtraction angiography and first-pass distribution algorithm were used to assess the absolute volumetric flow rates. The method, based on the conservation of contrast material in successive angiographic images, uses the videodensitometric information in the arterial bed. Measurements were made by summing the pixel values in the region of interest, covering the whole perfusion bed. A contrast pass curve was generated for a sequence of images to obtain instantaneous volumetric flow rates. RESULTS: Instantaneous and mean absolute volumetric flow measurements made in the angiographic perfusion phantom and the common carotid artery of the animal models correlated well with validation measurements made using ultrasound flowprobes. The measured (M) and known (K) flow rates in the carotid artery were related by M = 0.87 K + 2.50 mL/minute (r = 0.96, standard error of the estimate = 3.79 mL/minute, n = 25) and M = 0.92 K - 1.00 mL/minute (r = 0.98, standard error of the estimate = 4.04 mL/minute, n = 38) using the videodensitometric and entrance vessel calibration techniques, respectively. Conclusion. Results demonstrate the potential use of the first-pass distribution method in conjunction with digital subtraction angiography for measuring phasic arterial blood flow in vivo.

Algorithms↗

Improved densitometric measurement of left ventricular ejection fraction using dual-energy digital subtraction angiography.

The effects of misregistration artifacts and background corrections on the densitometric measurement of left ventricular ejection fraction (EF) from digital subtraction angiography (DSA) images were studied in 20 patients. Densitometric ejection fraction measurements were performed on both conventional time subtraction images and on dual-energy subtraction images. Dual-energy subtraction is not sensitive to the motion induced artifacts which often mar time subtraction images. While the time subtraction images had varying degrees of misregistration artifacts, none of the dual-energy studies contained significant misregistration artifacts. Densitometrically determined ejection fractions measured with and without correction for background signals were compared. Poor agreement between time subtraction ejection fractions determined with and without background correction (EFNO-BKG = 0.88 EFBKG - 6.0%, SEE = 8.1%, r = 0.83) demonstrated the sensitivity of time subtraction EFs to the performance of a background correction procedure. Conversely, densitometric measurement of ejection fraction using dual-energy subtraction was significantly less sensitive to the performance of a background correction (EFNO-BKG = 0.99 EFBKG - 5.3%, SEE = 4.3%, r = 0.96). Since background correction requires accurate definition of ventricular borders, but motion artifacts often preclude accurate border definition, it is concluded that dual-energy subtraction is a significantly more robust method for measuring left ventricular ejection fraction using densitometry. It is further concluded that identification of the systolic endocardial border is not required when performing densitometric EF measurements on dual-energy images. Drawing of the end-diastolic border alone is sufficient to produce an accurate ejection fraction measurement.

Adult↗

X-ray digital subtraction angiography with 1 mol/L gadobutrol: results from a comparative porcine study With iodinated contrast agents.

RATIONALE AND OBJECTIVES: To evaluate prospectively diagnostic accuracy of 1 mol/L gadobutrol as a contrast agent for intraarterial x-ray digital subtraction angiography (DSA) in comparison to iodinated, nonionic contrast media and 0.5 mol/L gadolinium-DTPA. METHODS: Flush arteriograms (ascending, descending, abdominal aorta, iliac, and femoral arteries) and selective angiograms (carotid, renal, and visceral arteries) were obtained from bilateral femoral arterial access (5 F sheaths) in 10 domestic pigs (70 kg body weight). Digital subtracted angiograms were obtained during injection of undiluted 1 mol/L gadobutrol, 300 mg I/mL iopromide, or 0.5 mol/L gadopentetate. Injection parameters (volume and velocity) were similar for all three contrast agents. In paired arteries, two different contrast media were used during the same angiographic run. Diagnostic quality and accuracy of the angiograms were evaluated on a three-step scale by three independent blinded investigators. RESULTS: Sufficient nonselective angiographic images were obtained in 90% of cases using iodinated contrast material. Gadobutrol achieved sufficient nonselective angiograms in 64%. Selective angiograms were sufficient in 98% using iodinated contrast material, 90% using 1 mol/L Gadobutrol and 48% using 0.5 mol/L Gd-DTPA. Adverse reactions to any of the used contrast agents were not noted. CONCLUSION: One mol/L Gadobutrol solution allows x-ray digital subtraction angiography with a diagnostic accuracy equivalent to 300 mg/mL iodinated contrast media, if selective injections are performed. Flush aortograms are of inferior image quality to iodinated contrast material.

Angiography, Digital Subtraction↗

[Quantitative assessments of regional myocardial perfusion by digital subtraction angiography].

Regional myocardial perfusion was evaluated by computerized washout analysis of digital subtraction angiography (DSA) images. Diatrizoate meglumine (76% Urografin), 2 to 3 ml, was manually injected into the left main coronary artery. For 26 patients with ischemic heart disease (IHD), 14 patients with cardiomyopathy, and eight patients with normal coronary angiograms, DSA images of myocardial perfusions were obtained in the right anterior oblique projection. These were digitized into an image-processing computer. Time-density curves were constructed in four segments of the left ventricle perfused by the left anterior descending coronary artery (LAD) and the contrast decay half-lives (T1/2) were calculated from the decay phases of the curves, using mono-exponential least square fits. The mean T1/2 was significantly longer in patients with 75% or more LAD narrowing than in those with normal coronary arteries. By contrast, patients with 50% or less LAD narrowing had T1/2 comparable to those with normal coronary arteries. In patients with IHD, there was a significant curvilinear relationship of T1/2 with percent stenosis of the LAD. This indicates that a decrease in regional myocardial flow develops rapidly in coronary stenosis of 70-80% or more. In patients with comparable coronary stenosis, T1/2 was significantly longer in the asynergic regions than in those with normal wall motion, but T1/2 was shorter in regions perfused by collateral vessels. These findings indicate that left ventricular contraction and collateral flow could contribute to regional myocardial perfusion. In addition, patients with hypertrophic and dilated cardiomyopathy had prolonged T1/2 despite normal coronary angiograms, suggesting abnormalities in intramural coronary arteries. Thus, T1/2 derived by computerized washout analysis of DSA myocardial image proved to be a useful index for quantitative evaluation of regional myocardial perfusion.

Adult↗

[Radiation exposure of the ocular lens and thyroid gland in digital subtraction angiography of brain-supplying arteries].

PURPOSE: To find out the individual level of radiation exposure of the ocular lens and thyroid gland during DSA of arteries supplying the brain, considering the indication. MATERIAL AND METHOD: The study was conducted on 72 patients during aortic arch and cerebral artery angiographies using thermoluminescent dosimetry. RESULTS: During 20 aortic arch angiographies the measured values were within non-critical limits, whereas during carotid, vertebral or cerebral four-vessel angiography of the left ocular lens exposure values of more than 500 mGy (max. 782 mGy) were stated in two of 52 cases. The highest measured exposure relating to the right ocular lens was 126 mGy, to the thyroid gland 88 mGy. However, in 51 of 52 cases thyroid gland doses of below 51 mGy were measured. In 71 of 72 cases there was a lateral difference between right and left lens exposure up to twice the measured dose for the right ocular lens during aortic arch angiographies and up to sixteen-fold in respect of the left lens during cerebral angiographies. CONCLUSION: In addition to the fluoroscopic time, number of images, fade-in and zoom some other dose-influencing factors, radiation geometry is especially decisive for organ exposure. The risk of cataracts or thyroid gland carcinomas/hypothyrosis can be neglected with median values of 40 and 70 mGy relating to the ocular lens and 17 mGy for the thyroid gland during cerebral angiographies.

Angiography, Digital Subtraction↗

Rotational digital subtraction carotid angiography: technique and comparison with static digital subtraction angiography.

Recent advances in angiography equipment have allowed the development of rotational digital subtraction carotid angiography. We give the first description of this technique applied to the extracranial carotid circulation, using the Phillips Integris V3000 release 11. Forty-three patients undergoing conventional digital subtraction angiography were compared with 63 patients who had rotational digital subtraction angiography for examination of the extracranial carotid circulation. The parameters compared were: total procedure time, volume of contrast injection, number of contrast injections, total data acquisition time, image quality, radiation dose and patient comfort. There was a reduction in the total procedure time, improvement in patient comfort, data acquisition time and a reduction in the number of injections. Conventional DSA may underestimate stenoses in 65% of cases. There is no significant change in the total volume of contrast injected. There is, however, an increase in the radiation dose during data acquisition.

Angiography, Digital Subtraction↗

Left atrial function in ischemic heart disease assessed by intravenous digital subtraction angiography.

To investigate changes in left atrial morphology and dimensions during the cardiac cycle, the atrium was visualized by intravenous digital subtraction angiography (DSA). The study subjects consisted of 22 male patients whose average age was 54.5 +/- 8.6 years. They had ischemic heart disease without mitral valve disease and were in sinus rhythm. They were 11 patients with old myocardial infarction (OMI group) and 11 who had chest pain without evidence of infarction (AP group). DSA was performed in the continuous mode. Contrast material (35 ml) was injected at a rate of 18 ml/sec via a catheter in the superior vena cava and subtraction images were obtained at a speed of 30 frames/sec in the right anterior oblique projection. The left atrial and left ventricular margins were traced manually, their areas were calculated, and fractional changes in area were analyzed. The left ventricular ejection fraction (LVEF) was calculated by densitometry. Cardiac catheterization was performed in 16 patients and the left ventricular end-diastolic pressure (LVEDP) and mean pulmonary arterial wedge pressure (PAWP) were measured. The entire left atrium was clearly imaged using DSA. Phase analysis of the time-area curves in the right anterior oblique projection revealed that the left atrial area was maximal during left ventricular end-systole (%LA1 = 100%), it decreased during early left ventricular diastole (%LA2), and then increased slightly again during mid-diastole (%LA3). After left atrial contraction, the minimum area was obtained (%LA4). The left atrium showed a two-stage decrease in the area due to passive emptying and active contraction during left ventricular diastole. Passive emptying (%LA1-%LA2) was significantly less in the OMI group than in the AP group (6.3 +/- 3.6 vs 13.3 +/- 4.8%, p < 0.01, respectively). In all 22 subjects, passive emptying correlated with LVEF (r = 0.70, p < 0.001) and LVEDP (r = -0.58, p < 0.05). There was no difference in active contraction (%LA3-%LA4) between the 2 groups (26.0 +/- 5.7% in the OMI group, 28.2 +/- 8.4% in the AP group), and it did not correlate with LVEF or LVEDP. The ratio of passive emptying to active contraction [(%LA1-%LA2)/(%LA3-%LA4)] correlated with LVEF (r = 0.63, p < 0.01). These findings suggested that impaired left ventricular diastolic function and a relative increase in atrial contraction were present in patients with a lower LVEF. The %LA4 correlated with LVEDP and PAWP (r = 0.65, r = 0.63, p < 0.01, respectively). In conclusion, DSA proved to be a useful method for investigating left atrial morphology and function.

Aged↗

Intra-arterial digital subtraction angiography (DSA) as an outpatient screening method for the follow-up of graft patency in coronary surgery.

In order to determine whether intra-arterial digital subtraction angiography (= DSA) is a suitable screening method to visualise graft patency and to determine whether DSA can be performed on an outpatient basis, we studied 73 patients shortly after coronary bypass surgery. In two patients DSA was precluded due to technical problems. The patency of the grafts was adequately visualised by means of DSA in 68 of the remaining 71 patients. During the DSA procedure complications occurred in two patients without serious consequences and bleeding at the puncture site was not observed in any patient whether mobilised at 24 or only 2 hours. We conclude that intra-arterial DSA is a suitable screening method to visualise patency in coronary bypass grafts and that it can be performed safely on an outpatient basis.

Ambulatory Care↗

Monitoring of pancreas-graft perfusion by radionuclide and digital subtraction angiography.

The vascularity of a kidney transplant can be evaluated by intravenous radionuclide angiography. A normal functioning transplant should have an isotope histogram with a well-defined peak. Accordingly, a transplanted pancreas may be evaluated in the same way. By intravenous digital subtraction angiography and small amounts of contrast medium, arterial and venous structures can be visualized without catheterization of the arterial system. Five patients had combined kidney and pancreas transplantation. Intravenous angiography with 99mTc-pertechnetate was performed three times a week for the first 5 postoperative wk. Digital subtraction angiography with an intravenous bolus of 80 ml of a low-osmolar nonionic contrast medium (iopamidol) was performed late in the postoperative course or when severe impairment of pancreas-graft perfusion was discovered by radionuclide angiography. One patient had two episodes and three patients one episode of rejection of both kidney and pancreas. Impairment of the pancreas-graft perfusion always preceded or was associated with deterioration of the graft function. In all patients, digital subtraction angiography demonstrated the graft vessels in sufficient detail. No thrombotic complications were observed. We conclude that these two methods can be used for monitoring the kidney and pancreas-graft perfusion. The methods may be of great value, especially in the early postoperative period, when problems with organ function are frequent and early intervention is essential.

Contrast Media↗

Time-of-flight MR angiography targeted to coiled intracranial aneurysms is more sensitive to residual flow than is digital subtraction angiography.

BACKGROUND AND PURPOSE: For intracranial aneurysms treated with Guglielmi detachable coils, long-term follow-up is mandatory because coil compaction may occur and aneurysms may recur. The purpose of this study was to establish a noninvasive technique to visualize residual flow in coiled aneurysms. METHODS: We designed a 3D time-of-flight (3D-TOF) MR angiography (MRA) technique targeted to depict coiled aneurysms that employed a very short TE (1.54-1.60 ms) and a high spatial resolution (0.3 x 0.3 x 0.3 mm3 with zero-filling) to diminish spin dephasing. To diminish spin saturation, image volume was carefully positioned so that the neck of the targeted aneurysm was within 2 cm of the inflow portion along the stream of blood. Fifty-one MRA images of 39 coiled aneurysms in 39 patients were compared with digital subtraction angiography (DSA) images. DSA and MRA findings were interpolated retrospectively for parent and branch arteries' patency, as well as residual flow in aneurysms. In the latest 11 MR studies, a dark-blood 3D turbo spin-echo sequence was added to MRA to negate the effect high-signal-intensity thrombus. RESULTS: MRA visualized all parent and branch arteries with DSA confirmation. MRA visualized residual flow more frequently (38 studies) than did DSA (25 studies). Residual flow space visualized with MRA was always similar to or larger than that with DSA. The dark-blood sequence completely suppressed intraluminal high signal intensity on MRA images and confirmed that the high signal intensity was not due to thrombus. CONCLUSION: TOF MRA targeted to depict coiled intracranial aneurysms is noninvasive and superior to DSA in visualization of residual flow and, hence, useful for follow-up of coiled aneurysms.

Aged↗

Is distortion correction necessary for digital subtraction angiography in the Gamma Knife treatment of intra-cranial arteriovenous malformations?

OBJECTIVE: The published literature maintains that distortion correction of digital subtraction angiography is essential for accurate definition of the arteriovenous malformation (AVM) nidus when performing Gamma Knife radiosurgery. However, as Gamma Knife treatments usually involve small volume targets, which are purposely positioned as close to the centre of the frame as possible, we postulated that the angiographic target images should be minimally distorted. Thus, the use of uncorrected images would not significantly compromise the accuracy of the treatment. We investigated this postulate. DESIGN: Patient and phantom images with and without distortion correction were assessed. The errors measured in the angiograms were compared to those of MR and CT images of the same subjects. Any errors less than 0.5 mm in any modality were accepted as intrinsic. RESULTS: All errors measured in the study were sub-millimetre. In the patient group, errors with distortion correction averaged 0.13 mm (range 0-0.3 mm). Without distortion correction, errors averaged 0.34 mm (range 0.1-0.6 mm). By comparison, the average error for intracranial MR imaging was 0.3 mm, with a maximum of 0.6 mm. CONCLUSION: For small, intracranial AVMs distortion correction did not significantly reduce the errors associated with the definition of the stereotactic co-ordinates. We suggest that prior to the purchase of this software, similar in-house testing should be performed.

Angiography, Digital Subtraction↗