PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “DAMPs”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32Linked to original sources

Influence of a stressing constraint on stiffness and damping functions of a ski simulator's platform motion.

The aim of this study was to assess the effect of stress on a previously acquired motor coordination. Following a longitudinal learning experiment, four participants performed oscillations on a ski simulator, either in normal or stressful conditions. The results showed that the amplitude of the oscillations decreased under stress, but no significant effect was seen regarding coordination, suggesting the strong resistance to stress of overlearned behaviour. Nevertheless, for one participant, a transient regression towards a former stage of learning was observed. This result was consistent with the regression hypothesis formulated by Fuchs (1962).

Adult↗

A damped oscillation in the intramembranous charge movement and calcium release flux of frog skeletal muscle fibers.

Asymmetric membrane currents and calcium transients were recorded simultaneously from cut segments of frog skeletal muscle fibers voltage clamped in a double Vaseline-gap chamber in the presence of high concentration of EGTA intracellularly. An inward phase of asymmetric currents following the hump component was observed in all fibers during the depolarization pulse to selected voltages (congruent to -45 mV). The average value of the peak inward current was 0.1 A/F (SEM = 0.01, n = 18), and the time at which it occurred was 34 ms (SEM = 1.8, n = 18). A second delayed outward phase of asymmetric current was observed after the inward phase, in those experiments in which hump component and inward phase were large. It peaked at more variable time (between 60 and 130 ms) with amplitude 0.02 A/F (SEM = 0.003, n = 11). The transmembrane voltage during a pulse, measured with a glass microelectrode, reached its steady value in less than 10 ms and showed no oscillations. The potential was steady at the time when the delayed component of asymmetric current occurred. ON and OFF charge transfers were equal for all pulse durations. The inward phase moved 1.4 nC/microF charge (SEM = 0.8, n = 6), or about one third of the final value of charge mobilized by these small pulses, and the second outward phase moved 0.7 nC/microF (SEM = 0.8, n = 6), bringing back about half of the charge moved during the inward phase. When repolarization intersected the peak of the inward phase, the OFF charge transfer was independent of the repolarization voltage in the range -60 to -90 mV. When both pre- and post-pulse voltages were changed between -120 mV and -60 mV, the equality of ON and OFF transfers of charge persisted, although they changed from 113 to 81% of their value at -90 mV. The three delayed phases in asymmetric current were also observed in experiments in which the extracellular solution contained Cd2+, La3+ and no Ca2+. Large increases in intracellular [Cl-] were imposed, and had no major effect on the delayed components of the asymmetric current. The Ca2+ transients measured optically and the calculated Ca2+ release fluxes had three phases whenever a visible outward phase followed the inward phase in the asymmetric current. Several interventions intended to interfere with Ca release, reduced or eliminated the three delayed phases of the asymmetric current.(ABSTRACT TRUNCATED AT 400 WORDS)

Animals↗

Sequence comparison by exponentially-damped alignment.

We describe a new method of comparing sequences, based on the Needleman-Wunsch sequence alignment algorithm, which can detect similarities that are interrupted by insertions or deletions in either sequence. The sequences are compared by calculating for each pair of residues a score which represents the best local alignment bringing those residues into correspondence; smooth localisation is achieved by reducing the contribution of distant parts of the alignment path by a factor which decreases exponentially with their distance from the point in question. The calculated values are used to draw a line graph in which regions of local similarity are shown by diagonal lines. Examples are shown of the application of the method to nucleic acid and amino acid sequences.

Animals↗

Biphasic shocks compared with monophasic damped sine wave shocks for direct ventricular defibrillation during open heart surgery.

BACKGROUND: Biphasic waveform shocks are more effective than monophasic shocks for transchest ventricular defibrillation, atrial cardioversion, and defibrillation with implantable defibrillators but have not been studied for open chest, intraoperative defibrillation. This prospective, blinded, randomized clinical study compares biphasic and monophasic shock effectiveness and establishes intraoperative energy dose-response curves. METHODS: Patients undergoing cardiothoracic surgery with bypass cardioplegia were randomly assigned to the monophasic or biphasic shock group. Ventricular fibrillation occurring after aortic clamp removal was treated with escalating energies of 2, 5, 7, 10, and 20 J until defibrillation occurred. If ventricular fibrillation persisted, a 20-J crossover shock of the other waveform was used. RESULTS: Cumulative defibrillation success at 5 J, the primary end point of the study, was higher in the biphasic group than in the monophasic group (25 of 50 vs. 9 of 41 defibrillated; P = 0.011). In addition, the biphasic group required lower threshold energy (6.8 vs. 11.0 J; P = 0.003), less cumulative energy (12.6 vs. 23.4 J; P = 0.002), and fewer shocks (2.5 vs. 3.5; P = 0.002). Crossover-shock effectiveness did not differ between groups. Dose-response curves show biphasic shocks to have higher cumulative success rates at all energies tested. CONCLUSIONS: Biphasic shocks are substantially more effective than monophasic shocks for direct defibrillation. The dose-response curve guides selection of first-shock energy for traditional step-up protocols. Starting at 5 J optimizes for lowest threshold and cumulative energy, whereas 10 or 20 J optimizes for more rapid defibrillation and fewer shocks.

Adult↗