Improved detection limit for a direct determination of 8-hydroxy-2'-deoxyguanosine in untreated urine samples by capillary electrophoresis with optical detection.

Method for a direct determination of 8-hydroxy-2'-deoxyguanosine (8OHdG) in untreated urine samples by capillary electrophoresis with optical detection was developed. Optimisation of conditions resulted in a significant lowering of the limit of detection (LOD) by a factor of 400 as compared to our previous study. Optimum separation of 8OHdG from other urine components was achieved using the separation electrolyte containing 80 mM 2-(cyclohexylamino)ethanesulfonic acid, 9 mM LiOH (pH 8.6), and 0.1 mM cetyltrimethylammonium bromide ensuring the electro-osmotic flow inversion. In the model aqueous samples, these conditions allow separating 8OHdG and 2'-deoxyguanosine (dG) from other nucleosides/nucleotides including 2'-deoxycitidine 5'-monophosphate (dCMP), thymidine 5'-monophosphate (TMP), adenosine (A), and thymidine (T). On the other hand, 2'-deoxyadenosine 5'-monophosphate (dAMP) and 2'-deoxyguanosine 5'-monophosphate (dGMP) migrate together, and guanosine (G), 2'-deoxyadenosine (dA), 2'-deoxycytidine (dC) are transported as neutral species with the electro-osmotic flow. In the spiked urine samples, 8OHdG and dG are well separated from each other and from other urine components and exhibit a linear calibration over the concentration range of 0.1-2.0 microM for 8OHdG (LOD = 42 nM) and 0.2-5.0 microM for dG (LOD = 86 nM), but urine metabolites interfere with the determination of dCMP, TMP, A and T. Method is applicable to untreated urine samples with slightly enhanced levels of 8OHdG compared to that found in healthy individuals.

8-Hydroxy-2'-Deoxyguanosine↗

Detection of d-Serine in rat brain by capillary electrophoresis with laser induced fluorescence detection.

A capillary zone electrophoresis method with laser induced fluorescence detection for the chiral separation of highly fluorescent enantiomeric derivatives of d/l-Serine from 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-d/l-Serine) was developed and optimized. Enantiomeric separation of NBD-d/l-Serine was accomplished by using 40 mM hydroxypropyl-beta-cyclodextrin (HP-beta-CD) contained in 100 mM borate buffer, pH 10.0. A 70 cm (effective length of 50 cm) uncoated fused-silica capillary at a voltage of 15 kV was used for the separation. The optimized electrophoretic conditions were subsequently applied to the analysis of d-Serine in rat brain, and satisfactory analytical results with respect to accuracy were obtained. This assay showed acceptable precision, with linearity in the d-Serine concentration range of 0.2-20.0 microM. The limit of detection for d-Serine was 3.0 x 10(-7)M.

4-Chloro-7-nitrobenzofurazan↗

NO-donors, part X [1] : investigations on the stability of pentaerythrityl tetranitrate (PETN) by HPLC-chemoluminescence-N-detection (CLND) versus UV-detection in HPLC.

HPLC in combination with chemoluminescence-N-detection (CLND) is very useful for the analysis of pentaerythrityl tetranitrate (PETN) and its possible biological and chemical degradation products pentaerythrityl trinitrate (PETriN), pentaerythrityl dinitrate (PEDiN) and pentaerythrityl mononitrate (PEMonoN). Quantification is more convenient and sensitivity of this method is about four times higher compared to UV-detection. The present study demonstrates that PETN is a chemically more stable compound in vitro than expected. No degradation was observed in aqueous buffers (37 degrees C, pH 5.6, 7.4), human plasma, and simulated intestinal or gastric fluid. On the other hand, the addition of increasing amounts of thioles (cysteine, thioglycolic acid) induced an increasing degradation of PETN.

Chromatography, High Pressure Liquid↗

[Early detection of hepatitis C virus infection using a new combined antigen-antibody detection assay: potential use in HIV co-infected individuals].

BACKGROUND: The aim of this study was to determine the clinical benefit of a new combined antigen-antibody immunoenzymatic assay (Monolisa HCV Ag-Ab Ultra, Biorad) in the setting of acute HCV infection in HIV infected patients. PATIENTS AND METHODS: The performance of this assay was first evaluated in 160 HIV positive samples from uninfected and chronically HCV infected patients. To assess the performance of the Ag-Ab assay in the context of acute hepatitis C, 94 stored frozen serums from 20 recently diagnosed cases were retrospectively tested for HCV-RNA and presence of anti-HCV antibodies, in parallel with the new assay. RESULTS: In HIV infected patients, the sensitivity and specificity of the Ultra assay was 100% with a strong discrimination between positive and negative samples. In HCV acutely infected patients, the Ag-Ab assay significantly reduced the seronegative period, allowing an earlier diagnosis compared to a 3rd generation ELISA in 65% of the cases. The combined assay became positive on the same bleed as the first HCV-RNA detection for 13 patients out of 20. Nevertheless, in one case, characterized by an absence of seroconversion over one year but a continuous viral replication above 1 million IU/ml, the combined assay did not improve HCV infection diagnosis. CONCLUSION: Use of this new assay as a first line screening would significantly reduce the long seronegative window period seen in HCV infection allowing earlier HCV diagnosis and rapid clinical management. However, in case of clinical acute hepatitis C, sensitive HCV-RNA detection should remain the gold standard.

Antigen-Antibody Complex↗

Solid-phase extraction of polar hydrophilic aromatic sulfonates followed by capillary zone electrophoresis-UV absorbance detection and ion-pair liquid chromatography-diode array UV detection and electrospray mass spectrometry.

A comprehensive comparison of four different polymeric solid-phase extraction (SPE) materials for the extraction of 22 different aromatic sulfonates of environmental concern was performed. The investigated adsorbents were the polystyrene-divinylbenzene materials LiChrolut EN from Merck, Isolute ENV+ from International Sorbent Technology, HR-P from Macherey-Nagel and the new Oasis HLB poly(divinylbenzene-co-N-vinylpyrrolidone) copolymer from Waters. Different SPE parameters like the elution solvent and the drying step of the cartridges were optimized. Analyses were performed by capillary zone electrophoresis-UV absorbance detection (CZE-UV) and ion-pair liquid chromatography-diode array UV detection coupled in series with electrospray mass spectrometry (IP-LC-DAD-ESI-MS) in the negative ionization mode. LC-MS offers a higher separation efficiency than CZE. The best adsorbents were LiChrolut EN and HR-P followed by Isolute ENV+ and Oasis HLB. The recoveries for most of the onefold negatively charged aromatic sulfonates were >50% for the extraction from spiked ground water at 50 microg/l. Recoveries for LiChrolut EN and HR-P were approximately 20% higher than for Isolute ENV+. Very hydrophilic sulfonates containing more than one negative sulfonate group could not be extracted by any of the tested adsorbents.

Calibration↗

Determination of quaternary alkylammonium compounds by capillary zone electrophoresis and indirect UV detection as a real alternative to ion chromatography with suppressed conductivity detection.

A capillary electrophoretic (CE) method for the determination of residual mid-chain alkyltrimethylammonium compounds in the pharmaceutical product Welchol (an alkylated, crosslinked polyallylamine) was developed, validated and compared with the existing ion chromatographic (IC) method with suppressed conductivity detection. Excellent reproducibilities of migration times (RSD<0.5% within a series of 55 sample injections) and relative peak areas (RSD<2%) make the method suitable for quality control as a real alternative to IC. Limits of quantification of 0.01% w/w of each impurity in the active substance were achieved. Buffer systems for indirect UV detection based on creatinine as visualization reagent with different inorganic and organic acids (phosphoric, sulfuric, formic, acetic, oxalic and citric acid) and their effect on selectivity to ten quaternary ammonium compounds were studied. Selectivity changes were observed for the di- and trivalent analytes depending on the buffer applied. Also, the influence of acetonitrile, methanol, 1,4-dioxane and tetrahydrofuran on selectivity was investigated. In addition, CE-MS experiments were carried out in order to identify several impurities in the product.

Chromatography, Liquid↗

Surface and wastewater quality monitoring: combination of liquid chromatography with (geno)toxicity detection, diode array detection and tandem mass spectrometry for identification of pollutants.

Identification of unknown water pollutants with liquid chromatography and tandem mass spectrometry (LC-MS-MS) is often more complex and time consuming than identification with gas chromatography and mass spectrometry (GC-MS). In order to focus the identification effort on relevant compounds, unknown peaks need to be selected carefully. Based on its frequency of occurrence in the LC-Diode Array Detection (LC-DAD) chromatograms of surface and infiltrated waters, an unknown peak was selected for identification with LC-MS-MS. This compound was identified as hexamethoxymethylmelamine (HMMM), a chemical often used in the coating industry. This is the first time the presence of this chemical in surface waters has been reported. In addition to HMMM, two other structurally related compounds were found to be present in the investigated surface water. A standard mixture of HMMM and its by-products did not exhibit (geno)toxicity under the test conditions applied in this study. In another example, a genotoxic fraction of an industrial wastewater was isolated and examined by LC-MS-MS using a modern quadrupole-orthogonal acceleration-time-of-flight mass spectrometer (Q-TOF). Four compounds were detected. The structures of two compounds present are proposed to be 9-amino-2-hydroxy-acridine and 9-hydroxy-acridine-N-oxide or its structural isomer dihydroxy-acridine. Confirmation with standards could not be carried out, as pure compounds are not available. The other two compounds (structural isomers) could not be identified based on the data available within this study.

Chromatography, High Pressure Liquid↗

Fractionation of starch hydrolysates into dextrins with narrow molecular mass distribution and their detection by high-performance anion-exchange chromatography with pulsed amperometric detection.

Low levels of high-molecular-mass dextrins in starch hydrolysates can be detected by high-performance anion-exchange chromatography with pulsed amperometric detection in spite of their low responses by dialysis of the starch hydrolysate and fractionation of the resulting adialysate with ethanol (final concentration 30-80% at 6 degrees C). In doing so, dextrin fractions with a relatively narrow molecular mass distribution were obtained.

Anion Exchange Resins↗

Dextrin characterization by high-performance anion-exchange chromatography--pulsed amperometric detection and size-exclusion chromatography--multi-angle light scattering--refractive index detection.

Starch hydrolysis products, or dextrins, are widely used throughout the food industry for their functional properties. Dextrins are saccharide polymers linked primarily by alpha-(1 --> 4) D-glucose units and are prepared by partial hydrolysis of starch. Hydrolysis can be accomplished by the use of acid, enzymes, or by a combination of both. The hydrolysis products are typically characterized by the "dextrose equivalent" (DE), which refers to the total reducing power of all sugars present relative to glucose. While the DE gives the supplier and buyer a rough guide to the bulk properties of the material, the physiochemical properties of dextrins are dependent on the overall oligosaccharide profile. High-performance anion-exchange chromatography (HPAEC) with pulsed amperometric detection and size-exclusion chromatography (SEC) with multi-angle light-scattering and refractive index detection were used to characterize dextrins from commercial sources. HPAEC was used to acquire the oligosaccharide profile, and SEC to obtain an overall molar mass distribution. These methods in combination extended our understanding of the relationship between oligosaccharide profile, DE, and the hydrolysis process. Data from the two techniques enabled a method for estimating the DE that gave results in reasonable agreement with the accepted titration method.

Anions↗

Determination of trichothecene mycotoxins in wheat by use of supercritical fluid extraction and high-performance liquid chromatography with diode array detection or gas chromatography with electron capture detection.

The extraction behaviour of the Fusarium mycotoxin deoxynivalenol (DON) and some related type B trichothecenes from spiked seasand, spiked wheat flour and naturally contaminated wheat flour with modified supercritical CO2 has been investigated and optimized under several conditions. The extraction fluid was decompressed over a solid-phase trap and the amount of deposited analytes was determined by HPLC-diode array detection (DAD) or GC-electron capture detection (ECD) without any further clean-up. Recovery rates as high as 90.1 +/- 10.7% were achieved for spiked wheat samples and 53.0 +/- 3.2% for naturally contaminated samples. The performance of the optimized supercritical fluid extraction (SFE) method was compared with an already well established analytical method employing extraction on a rotary shaker in combination with Mycosep clean-up. Moreover, the SFE procedure developed for naturally DON contaminated wheat was employed for the simultaneous extraction of 5 type B trichothecenes by GC-ECD. This work represents the first successful approach in obtaining an SFE-method for the extraction of Fusarium mycotoxins from wheat with reasonable recoveries and good precision.

Chromatography, Gas↗

Intra-arterial calcium stimulation test for detection of insulinomas: detection rate, responses of pancreatic peptides, and its relationship to differentiation of tumor cells.

The selective intra-arterial calcium stimulation test has greatly facilitated the precise regionalization of insulinomas smaller than 2 cm, which noninvasive techniques (ultrasound [US], computed tomography [CT], magnetic resonance imaging [MRI]) often fail to localize. This study examined not only the role of the test in the localization of insulinomas, but also the responsiveness of 3 beta-cell peptides (insulin, C peptide, and proinsulin) and their relationship to the degree of differentiation of the tumor cells, using percentage decrease of both proinsulin/insulin (P/I) and proinsulin/C peptide (P/C) ratios after stimulation as indices. Ten consecutive surgically proven insulinoma patients each received an injection of calcium into the arteries supplying the pancreas after standard selective angiography and beta-cell peptide levels were measured in samples taken from the right hepatic vein before and 30, 60, 90, 120, and 180 seconds after each injection prior to operation. After surgery, the expressions of the calcium sensing receptor (CaSR) on the resected tumors were assessed by immunohistochemistry. Intra-arterial calcium stimulation with sampling either for insulin or for C peptide correctly predicted the site of insulinoma in 8 of 9 patients or in 7 of 8 patients if the 2 big malignant insulinomas were excluded; thus, the detection rate of this test was 89% and 88%, respectively. Calcium administration stimulated a marked and prompt release of insulin and C peptide simultaneously. Both peaked within 30 to 60 seconds, then declined gradually thereafter, remaining above the baseline at 180 seconds. The magnitude of increase correlated well with the corresponding percentage decrease of P/I and P/C ratios. The response of proinsulin was much less. Immunohistochemistry demonstrated variable membraneous staining for CaSR in normal pancreatic islets and in about 9% of the total normal beta cells, whereas staining in tumor cells was only minimally detectable. We conclude that selective intra-arterial calcium stimulation with hepatic venous sampling either for insulin or for C peptide is a highly sensitive method for the preoperative localization of small insulinomas. Calcium injection stimulates a brisk response of insulin, C peptide, and proinsulin simultaneously and the magnitude of increase of both insulin and C peptide appears to be correlated well with the degree of differentiation of the tumor cells. The exact mechanism by which calcium provokes the release of beta-cell peptides is less clear and whether the CaSR is involved in the mechanism of its action requires further study.

Adult↗

The incidence of clinical malaria detected by active case detection in children in Ifakara, southern Tanzania.

Between July 2000 and June 2001, we used weekly active case detection (ACD) of clinical malaria episodes in 618 children aged < 5 years to describe the epidemiology of malaria in Ifakara, southern Tanzania. Plasmodium falciparum-positive blood slides prepared from children with axillary temperature 37.5 degrees C were used to define clinical malaria and a rolling cross-sectional survey documented the prevalences of parasitaemia and anaemia. A random subsample of children was visited daily for 1 month at the end of the study to assess the effect of more frequent visits on estimated incidence rates. Only 50 (8%) children had 1 or more episodes of clinical malaria during the year, an overall incidence of 0.275 episodes/100 child-weeks-at-risk, with no age dependence. The maximum parasite prevalence of 25% was reached in children aged 4 years. The incidence of illness was significantly lower in children visited daily than in those visited weekly, suggesting a marked effect of frequent visits on estimated incidence rates. We conclude that the age pattern of malaria detected through ACD is a more robust epidemiological indicator than absolute incidence rate estimates and that, in contrast to the surrounding area, Ifakara town is subject to only moderate perennial malaria transmission.

Anemia↗

Speciation of aluminium in forest soil extracts by size exclusion chromatography with UV and ICP-AES detection and cation exchange fast protein liquid chromatography with ETAAS detection.

Aluminium speciation was studied in forest soil extracts by size exclusion chromatography (SE) with UV and inductively coupled plasma-atomic emission spectrometric (ICP-AES) detection and cation exchange fast protein liquid chromatography (FPLC) with ETAAS detection. Size exclusion chromatography was performed on a Superdex HR75 10/30 column. Isocratic clution with 0.15 mol dm(-3) NaCl in TRIS-HCl buffer (pH = 5.5) was applied over 100 min at a flow rate of 0.35 cm(3) min(-1). The chromatographic run was followed at 278 nm and separated Al species also determined 'off line' in 0.875 cm3 fractions by ICP-AES. The analytical procedure enabled speciation of high molecular weight Al complexes. Cation exchange FPLC was performed on a Mono S HR 5/5 column. Aqueous 8 mol dm(-3) NH4NO3 linear gradient elution was applied over 10 min at a flow rate of 1 cm3 min(-1). Separated Al species were collected in 0.5 cm3 fractions and Al determined 'off line' by ETAAS. The analytical procedure enabled speciation of some positively charged monomeric Al species. Negatively charged species were eluted with the solvent front. The combination of the two analytical techniques was successfully employed in speciation of Al in forest soil extracts. Water was used as an extracting solution. It was found experimentally that 80-95% of Al in aqueous extracts of forest soils exists in monomeric Al forms. Water soluble Al (30-40%) is bound to high molecular weight complexes with humic substances. The remaining monomeric Al in the low molecular weight fraction exists as AIF2+, Al-oxalate and Al-citrate species.

Aluminum↗

Detection of HLA polymorphisms by ligase detection reaction and a universal array format: a pilot study for low resolution genotyping.

We present our results in the identification of polymorphic sites within the second exon of the human leukocyte antigen A (HLA-A) region using the DNA microarray technology. Allele specific detection was performed by polymerase chain reaction followed by ligase detection reaction (LDR) in combination with a universal array, a powerful method for high throughput DNA sequence analysis. By this approach we confirmed 32 human samples previously characterized by direct DNA sequencing, thus demonstrating the interest of this approach.

DNA Ligases↗

Combination of liquid chromatography with ultraviolet detection and gas chromatography with electron-capture detection for the determination of delta 9-tetrahydrocannabinol-11-oic acid in urine.

A method is described for the determination of delta 9-tetrahydrocannabinol-11-oic acid (delta 9-THC-11-oic acid) in urine by using a combination of liquid chromatography and glass capillary gas chromatography with electron-capture detection. Prior to extraction, the glucuronide conjugate of delta 9-THC-11-oic acid was enzymatically converted to the free acid and delta 8-THC-11-oic acid added as an internal standard. An aliquot of the extract was separated by liquid chromatography and one eluate fraction containing delta 8-THC-11-oic and delta 9-THC-11-oic acids was collected. Before gas chromatographic analysis the acids were converted to their pentafluoropropyl-pentafluoropropionyl derivatives. Authentic urine samples, positive with the EMIT cannabinoid assay, were analysed and the results compared with those obtained from an earlier described gas chromatographic-mass spectrometric method. The detection limit for the overall method was approximately 20 ng/ml. The precision was 8% for a sample concentration of 90 ng/ml of delta 9-THC-11-oic acid in urine.

Chromatography, Gas↗

Development of an analytical method for penicillin G in bovine milk by liquid chromatography with ultraviolet-visible detection and confirmation by mass spectrometric detection.

A liquid chromatographic (LC) method with ultraviolet-visible photodiode array (UV-VIS PDA) detection was developed to measure penicillin G in bovine milk. A liquid chromatographic-mass spectrometric (LC-MS) procedure was divised to confirm the LC method. The method involved diluting milk with a drug-releasing solvent consisting of acetonitrile-methanol-water and ultrafiltration through a 10,000 dalton cutoff filter. Penicillin G was separated from other components in the ultrafiltrate by ion-paired LC using a reversed-phase microbore column eluted with a 25% acetonitrile solution. The LC method was confirmed by thermospray LC-MS. The detection limit for penicillin G determination in milk was estimated to be 10 ppb for LC with UV-VIS PDA and 100 ppb for LC-MS.

Animals↗

Determination of catecholamines in human plasma by high-performance liquid chromatography: comparison between a new method with fluorescence detection and an established method with electrochemical detection.

We report a sensitive fluorimetric method, in which catecholamines are concentrated from plasma by liquid-liquid extraction and derivatized with the selective fluorescent agent 1,2-diphenylethyl-enediamine prior to chromatography. Optimal conditions for extraction, derivatization and chromatography were investigated. With alpha-methylnorepinephrine as internal standard, the chromatographic separations are complete within 6 min. Limits of detection are 0.3 pg for norepinephrine and epinephrine and 0.5 pg for dopamine. Coefficients of variation are low (3-7%). Comparison of plasma catecholamine values determined with this method and with an established method with electrochemical detection (n = 135) shows good correlation (r = 0.94-1.00), and regression lines are close to lines of identity.

Chromatography, High Pressure Liquid↗

Liquid chromatography with electrochemical detection for the determination of choline and acetylcholine in plasma and red blood cells. Failure to detect acetylcholine in blood of humans and mice.

An assay is described for the measurement of choline in plasma and red blood cells using liquid chromatography, an enzyme reactor and electrochemical detection after a simple sample pretreatment. The intra-assay coefficient of variation for choline was 6.2 and 3.8% in plasma and in red blood cells, respectively. Using this method we have re-investigated the presence of acetylcholine in blood constituents. We were not able to demonstrate acetylcholine with a limit of detection of 10 pmol per ml of plasma or per ml of red blood cells.

Acetylcholine↗