PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Graphite”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32Linked to original sources

[Determination of minerals and trace elements in selenium tea from the Enschi district, People's Republic of China, and in its infusions using inductively coupled plasma-atomic emission spectrometry, graphite furnace atomic absorption spectrometry and instrumental neutron activation analysis].

The Enschi district in Hubei province, Peoples Republic of China is geochemically one of the two seleniferous regions, producing both selenium (Se) black tea and the Se green tea. Three samples of green tea with different Se contents and one non-Se tea were analysed. The following mineral and trace elements were determined by inductively coupled plasma-atomic emission spectrometry (ICP-AES): K, Ca, Mg, Na, P, S, Al, Mn, Fe, Ba, Sr, Co, Ni, Cu, Zn, Mo, and Cr. Except for Mo, Co, and Cr, all other elements in infusions of the samples analysed were also measured, since their concentrations are lying over their detection limits. The Se content in the tea samples and in the infusions were measured with graphite furnace atomic absorption spectrometry (GFAAS). The accuracy of Se determination was tested by measuring untreated tea samples with instrumental neutron activation analysis (INAA). The Se content in the measured samples was 1 to 8.5 micrograms/g. In addition to Se, 17 other elements were measured in the tea samples and 14 others in the infusions. With this data the extractable part of this elements in the infusion were calculated. Up to 10% of the Se was found in a first infusion.

China↗

Chromium, lead and cadmium in Danish milk products and cheese determined by Zeeman graphite furnace atomic absorption spectrometry after direct injection or pressurized ashing.

A method for the direct determination of chromium in homogeneous samples of milk and milk products is described. Minimum sample handling and prevention of contamination was given priority. After injection of the sample into the graphite furnace, the sample was ashed in a stream of oxygen at 650 degrees C and then further ashed at 1,100 degrees C with argon as the purge gas. Zeeman background correction was used in the atomisation step at 2,300 degrees C. The detection limit was 0.7 ng/g. Direct detection of chromium in milk, using only argon as purge gas, was inferior. Non-homogeneous and solid samples, e.g. yoghurt with fruit jam and cheese, were ashed under pressure with nitric acid before analysis. The same analytical principle as used for chromium was also used for the analysis of lead and cadmium in the samples. Analytical quality control was performed for both methods and the results are reported. The results for lead, cadmium and chromium in Danish milk and milk products were in the parts per billion or parts per trillion range and compare well with literature data. The intake of lead, cadmium and chromium from milk and milk products is less than 4% of the total Danish dietary intake of these elements. It is concluded that the contribution from milk and milk products to the total intake of lead and cadmium is toxicologically insignificant and that milk and milk products are only a minor source of the essential element chromium.

Animals↗

Direct determination of selenium in human blood plasma and seminal plasma by graphite furnace atomic absorption spectrophotometry and clinical application.

Direct determination of selenium (Se) in body fluids by graphite furnace atomic absorption spectrophotometry (GFAAS) may suffer from problems like severe background, matrix effects, preatomization losses, and spectral interferences. In this study we evaluate critically the influence on the accuracy of the direct determination of Se in blood plasma and seminal plasma by GFAAS, and propose a simple, rapid, and accurate method, suitable for routine clinical analysis. The method for blood plasma is mainly based on studies by the use of matched matrix and a Pd-Ni modifier, but for seminal plasma only a Pd modifier is required. The method developed was also applied to study the Se distribution in plasma protein fractions of patients with hepatocellular carcinoma. The Se in plasma of patients was significantly lower than that of the controls. The distribution pattern of Se in blood plasma fractions of patients was also different from that of the controls.

Adult↗

Serum nickel levels of diabetic patients and healthy controls by AAS with a graphite furnace.

In this study, serum nickel levels of diabetic patients and healthy controls were determined by AAS with a graphite furnace. The serum nickel concentrations were found to be 1.15 +/- 1.89 micrograms/L in healthy controls and 0.82 +/- 0.74 microgram/L in diabetics. There was, however, no statistically significant difference between the two groups (p = 0.13). The relationship of nickel levels to diabetes type and duration, diabetic complications and treatment, sex, age, and heredity was investigated. However, again no significant differences were found, nor was there any correlation between serum nickel levels and blood sugar, HBa1c, fructosamine, sialic acid levels, and age.

Adult↗

Physiological chromium determination in serum by Zeeman graphite furnace atomic absorption spectrometry. A serious challenge.

Several authors have already underlined chromium implication in glucose and lipids metabolism of humans. In this field, physiological chromium determination in serum could be helpful, but the discrepancies reported in numerous papers are confusing. Here we report some results obtained by Zeeman correction Graphite Furnace Atomic Absorption Spectrometry. This technique includes a dilution of serum with 12.5 mM ultrapure nitric acid and 0.25% Triton X-100 (final concentrations). Some main features can be outlined: (1) the contamination constitutes a serious drawback and (2) the sensitivity of the technique is critical (characteristic mass found: 1.76 pg/0.0044 A.s). Our results obtained from 27 healthy subjects (2.01 +/- 0.77 nmol/L) agree with most recent studies and indicate that serum chromium level does not seem to be sex-related.

Chromium↗

Performance of permanent iridium modifier in the presence of corrosive matrix in graphite furnace atomic absorption spectrometry.

The influence of up to 16% HNO3, 28% HCl, and the mixture of both acids in aqua regia on the analytical performance of electrodeposited modifiers (Ir or Ir+Pd) was evaluated and discussed. Cadmium was used as an example of volatile elements often determined by graphite furnace atomic absorption spectrometry (GF AAS). In the presence of HCl, the maximum pyrolysis temperature that could be applied was found to be 600 degrees C. In the presence of HNO3 and aqua regia, both modifiers stabilized cadmium up to 800 degrees C. The long-term performance of electrodeposited Ir or Ir+Pd was not influenced by mineral acids; moreover the tube lifetime was significantly prolonged compared with a non-modified tube.

Journal Article↗

Graphite furnace atomic absorption spectrometry used for determination of total, EDTA and acetic acid extractable chromium and cobalt in soils.

Methods for determination of both the total and extractable content of Cr and Co in soil samples were investigated. For the total content of metal, ultrasonic slurry sampling graphite furnace atomic absorption spectrometry was used and compared with conventional analyses after microwave digestion. The influence of grinding, leaching and homogeneity for slurry sampling was also examined. The concentration of the elements in the analyzed materials were in the range: 50 microg g(-1)-0.4% for Cr and 8-14 microg g(-1) for Co. Relative standard deviations (slurry sampling) were in the range 3%-12% for Cr and 0.3%-6% for Co determinations. The detection limit and characteristic mass (peak-area measurements) for Co were 0.14 microg g(-1) and 12.6 pg, respectively. For Cr less sensitive wavelengths were used. Excellent agreement with certified reference material was found for total Cr and Co using slurry sampling. EDTA and acetic acid extractions were performed, using protocols given by the Measurement and Testing Programme of the European Commission. The percentages extracted for the different soil samples were 0.3-1.0 for Cr and 2.5-24 for Co. To validate the accuracy of the extractable Cr, CRM 483 Sewage sludge amended soil was analyzed. The values found were 37% and 32% higher than the certified value for EDTA and acetic acid extractable Cr, respectively. The precision for extractable concentration of Cr and Co was about 6% or less. External calibration with aqueous standards, matched to contain the same reagents as the samples, was employed.

Journal Article↗

Determination of total platinum in plasma and plasma ultrafiltrate, from subjects dosed with the platinum-containing N-(2-hydroxypropyl)methacrylamide copolymer AP5280, by use of graphite-furnace Zeeman atomic-absorption spectrometry.

AP5280 is an N-(2-hydroxypropyl)methacrylamide (HPMA) copolymer to which are linked tetrapeptide side chains containing bioactive platinum complexes at their C-terminal sides. We have developed and validated a rapid and sensitive analytical assay for the determination of total platinum concentrations in plasma, and free platinum of an AP5280 origin in plasma ultrafiltrate (PUF), of subjects dosed with AP5280. The total platinum levels were determined by use of graphite-furnace atomic-absorption spectrometry (GF-AAS) with Zeeman correction after appropriate dilution of the plasma sample with plasma-hydrochloric acid 0.2 mol L(-1) (1:5) as diluent. The limit of quantitation of this assay is 0.25 micromol L(-1) platinum in plasma. Linear calibration curves were obtained over the concentration range 0.25-5.0 micromol L(-1). Accuracy was between 87.7% and 104.2% and precision was 15.3% at the lowest concentration and less than 14% for all other levels tested. Accuracy and precision were thus in accordance with generally accepted criteria for analytical methods. Analysis of samples obtained from patients receiving AP5280 demonstrated the applicability of the described assay. Analysis of free platinum in PUF was performed by use of a previously validated and reported assay from our institute in which the same instrumental method is used.

Acrylamides↗

Influence of experimental parameters on the determination of antimony in seawater by atomic absorption spectrometry using a transversely heated graphite furnace with Zeeman-effect background correction.

Spectroscopic and electrothermal conditions for the determination of antimony in seawater using a transversely heated graphite furnace with Zeeman-effect background correction have been optimized with the use of an a priori calculation of the detection limit. The lowest limit of detection was obtained with a 2 nm spectral curvatures bandwidth and the use of an electrodeless discharge lamp; however, these experimental conditions resulted in strong premature curvature of calibration curves. Pd(NO(3))(2) can be recommended as a chemical modifier because seawater interference effects are minimized and pretreatment curves up to 1500 degrees C can be used permitting the removal of the major part of the saline matrix before atomization. Under optimized spectroscopic and electrothermal conditions the obtained limit of detection of Sb in seawater was about 0.4 microg L(-1).

Antimony↗

Method development for the determination of iron in milligram amounts of rice plants (Oryza sativa L.) from cultivation experiments using graphite furnace atomic absorption spectrometry.

The amount of sample that is available for analysis in laboratory plant cultivation experiments is usually very limited. Highly sensitive analytical techniques are therefore required, even for elements that are present in the plants at mg g(-1) concentrations, and graphite furnace atomic absorption spectrometry (GFAAS) was chosen in this work because of its micro-sampling capability, and its relatively simple operation. Four micro-methods were investigated for the determination of iron in roots and leaves of rice plants: i) a micro-digestion with nitric and hydrochloric acids, ii) a slurry procedure using tetramethylammonium hydroxide (TMAH) tissue solubilizer, iii) a slurry prepared in 1.4 mol L(-1) nitric acid, and treated in an ultrasonic bath, and iv) the direct analysis of solid samples. The micro-digestion was suffering from high blank values and contamination problems, so that it could not be recommended for routine purposes. The TMAH method exhibited poor precision and occasional low recoveries, particularly for real samples. Direct solid sampling analysis gave results similar to those obtained with the slurry technique with ultrasonic agitation for the determination of iron in certified reference materials with iron content up to about 100 microg g(-1), but was too sensitive for the investigated rice plants, which had an iron content up to several mg g(-1). The slurry technique with ultrasonic treatment of the samples, suspended in dilute nitric acid, was finally adopted as the method of choice. The method was then applied for the determination of iron in the leaves and in different compartments of the roots of two rice cultivars, one sensitive to iron toxicity, an important nutritional disorder, and the other one resistant to iron toxicity. The results suggest that the higher resistance to iron toxicity of the second cultivar is due to a smaller uptake of iron from the soil, resulting in lower iron levels in all compartments of the plant.

Journal Article↗

Preconcentration of copper, cadmium, and lead with a thiacalix[4]arenetetrasulfonate-loaded Sephadex A-25 anion-exchanger for graphite-furnace atomic-absorption spectrometry.

A rapid column-adsorption method has been developed for concentrating traces of copper, cadmium, and lead in water prior to their determinations by graphite-furnace atomic-absorption spectrometry. The adsorbent used was prepared by loading a strongly basic anion-exchanger QAE-Sephadex A-25 (50 mg) with thiacalix[4]arenetetrasulfonate (20 micromol). Two-hundredfold preconcentration of the analyte elements was achieved by passing 100 mL of sample solution (pH 8.0) through a column packed with the adsorbent (6 mm i.d. x 7 mm high) at a flow rate of 10 mL min(-1) and by the subsequent elution with 500 microL of aqueous nitric acid solution (1 mol L(-1)). The practical applicability of the proposed method was evaluated by analyzing certified reference seawater samples.

Journal Article↗

Determination of cadmium in coal using solid sampling graphite furnace high-resolution continuum source atomic absorption spectrometry.

This work describes the development of a method to determine cadmium in coal, in which iridium is used as a permanent chemical modifier and calibration is performed against aqueous standards by high-resolution continuum source atomic absorption spectrometry (HR-CS AAS). This new instrumental concept makes the whole spectral environment in the vicinity of the analytical line accessible, providing a lot more data than just the change in absorbance over time available from conventional instruments. The application of Ir (400 microg) as a permanent chemical modifier, thermally deposited on the pyrolytic graphite platform surface, allowed pyrolysis temperatures of 700 degrees C to be used, which was sufficiently high to significantly reduce the continuous background that occurred before the analyte signal at pyrolysis temperatures <700 degrees C. Structured background absorption also occurred after the analyte signal when atomization temperatures of >1600 degrees C were used, which arose from the electron-excitation spectrum (with rotational fine structure) of a diatomic molecule. Under optimized conditions (pyrolysis at 700 degrees C and atomization at 1500 degrees C), interference-free determination of cadmium in seven certified coal reference materials and two real samples was achieved by direct solid sampling and calibrating against aqueous standards, resulting in good agreement with the certified values (where available) at the 95% confidence level. A characteristic mass of 0.4 pg and a detection limit of 2 ng g(-1), calculated for a sample mass of 1.0 mg coal, was obtained. A precision (expressed as the relative standard deviation, RSD) of <10% was typically obtained when coal samples in the mass range 0.6-1.2 mg were analyzed.

Cadmium↗

Determination of cobalt in sewage sludge using ultrasonic slurry sampling graphite furnace atomic absorption spectrometry.

Cobalt in sludge of domestic and industrial origin, with high iron contents (> 17 g/kg), was determined by slurry sampling graphite furnace atomic absorption spectrometry (GF-AAS). Slurries prepared by ultrasonic stirring were adequately diluted to cover the variation in cobalt content in the sludge samples. The diluent was 5% HNO3. Standard atomisation conditions for cobalt determination were used and no matrix modifier was applied. Slurry sampling GF-AAS results in the sludge were verified by analysing totally digested samples by inductively coupled plasma atomic emission spectrometry (ICP-AES) and by GF-AAS. The procedure was validated by analysing the certified reference material BCR 146 R, a sewage sludge of industrial origin. Recoveries for cobalt in the spiked slurried sludge samples ranged from 92 to 96%, with a relative standard deviation of 10%. Recoveries in the certified sludge using slurry sampling GF-AAS technique were about 103% for a cobalt content of 7.39 mg/kg.

Cobalt↗

Graphite furnace-atomic absorption spectrophotometric determination of palladium in soil.

A new and sensitive procedure for the graphite furnace-atomic absorption spectrophotometric (GF-AAS) determination of Pd in soil at nanogram level is described. The method is based on prior separation and enrichment of the metal as Pd(II)-SnCl3- -N-butylacetamide (BAA) complex into 1-pentanol (PN) by solvent extraction method. The value of the molar absorptivity of the complex in three solvents, i.e. ethyl acetate, 1-pentanol, chloroform, lie in the range of (0.70-2.75) x 10(4) L mol(-1) cm(-1) at lambda(max) 360-440 nm. The metal could be enriched into organic solvent, i.e. PN, up to 10-folds. The sensitivity (A = 0.0044) of the method in the term of the peak height was 0.5 ng Pd/mL of the aqueous solution at an enrichment factor (EF) of 5. Optimization of analytical variables during enrichment and GF-AAS determination of the metal are discussed. The method has been applied for the analysis of Pd to soil samples derived from roads and highways in Germany.

Palladium↗

Surface-renewable cobalt(II) hexacyanoferrate-modified graphite organosilicate electrode and its electrocatalytic oxidation of thiosulfate.

Cobalt(II) hexacyanoferrate (CoHCF) was deposited on graphite powder by an in situ chemical deposition procedure and then dispersed into methyltrimethoxysilane-derived gels to prepare a surface-renewable CoHCF-modified electrode. The electrochemical behavior of the modified electrode in different supporting electrolyte solutions was characterized by cyclic voltammetry. In addition, square-wave voltammetry was employed to investigate the pNa-dependent electrochemical behavior of the electrode. The CoHCF-modified electrode showed a high electrocatalytic activity toward thiosulfate oxidation and could thus be used as an amperometric thiosulfate sensor.

Journal Article↗

Cadmium analysis in soil by microwave acid digestion and graphite furnace atomic absorption spectrometry.

The need to determine micronutrients and toxic elements in soils has grown in recent years and cadmium is of special interest. A method has been developed for the determination of cadmium in soils based on a prior acid digestion of the samples with nitric acid in closed Teflon vessels, into a microwave over. The cadmium determination was carried out by graphite furnace atomic absorption spectrometry (GFAAS) with L'vov platform. Optimum operating conditions, analyte modifiers and matrix interferences have been investigated. The best matrix modifier was found to be ammonium dihydrogen phosphate. The interferences are greatly reduced under these operating conditions and calibration can be performed with simple aqueous solutions of the metal standard. The method is rapid and provides accurate and precise results that agree with certified values for two reference materials: BCR 141 (calcareous loam soil) and BCR 277 (estuarine sediment).

Journal Article↗

Intracavity laser atomic absorption spectrometry with graphite furnace atomizer or pulsed laser sampler.

An absorption intracavity laser spectrometer with two types of sample vaporization systems (graphite furnace electrothermal atomizer or laser sampler) is described that can be used for the determination of trace amounts of metals (Al, Cr, Fe and Mn) in liquid samples and at the surface of solid targets. The limits of detection for the elements tested are lower than those obtained by modern conventional spectrometers. The examined technique provides a wide dynamic range of linear standard calibration curves.

Journal Article↗

Instrumentation for simultaneous multielement atomic absorption spectrometry with graphite furnace atomization.

Graphite furnace-atomic absorption spectrometry (GF-AAS) is restricted to the determination of 4 to 6 elements simultaneously due to the limitations of hollow cathode lamps. However, a consideration of prototype continuum source instruments and recent advances in the fields of spectrometer and detector technology suggests that a multielement GF-AAS instrument, with the multielement versatility associated with atomic emission spectrometry, is possible. Such a multielement instrument would employ a continuum source and provide 1.) multielement determinations for 30 to 40 elements, 2.) wavelength and time integrated absorbance measurements which are independent of the source width, 3.) detection limits comparable to line source AAS with the potential for another order of magnitude improvement using atomization at elevated pressures, 4.) extended calibration ranges limited only by the memory of the atomizer, and 5.) high resolution inspection of the spectra surrounding the analytical wavelength. Such an instrument could provide figures of merit comparable to inductively coupled plasma-mass spectrometer with considerably less complexity.

Journal Article↗