PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Resolution”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 577 records · Page 32Linked to original sources

Spectral domain optical coherence tomography: ultra-high speed, ultra-high resolution ophthalmic imaging.

OBJECTIVE: To introduce a new ophthalmic optical coherence tomography technology that allows unprecedented simultaneous ultra-high speed and ultra-high resolution. METHODS: Using a superluminescent diode source, a clinically viable ultra-high speed, ultra-high resolution spectral domain optical coherence tomography system was developed. RESULTS: In vivo images of the retina, the optic nerve head, and retinal blood flow were obtained at an ultra-high speed of 34.1 microseconds (ms) per A-scan, which is 73 times faster than commercially available optical coherence tomography instruments. Single images (B-scans) consisting of 1000 A-scans were acquired in 34.1 ms, allowing video rate imaging at 29 frames per second with an axial resolution of 6 mum. Using a different source in a slightly slower configuration, single images consisting of 500 A-scans were acquired in 34 ms, allowing imaging at 29 frames per second at an axial resolution of 3.5 microm, which is 3 times better than commercially available optical coherence tomography instruments. The amount of energy directed into the eye in both cases, 600 microW, is less than that of the Stratus OCT3 and is safe for intrabeam viewing for up to 8 hours at the same retinal location. CONCLUSION: Spectral domain optical coherence tomography technology enables ophthalmic imaging with unprecedented simultaneous ultra-high speed and ultra-high resolution.

Adult↗

Ultrahigh-resolution optical coherence tomography of surgically closed macular holes.

OBJECTIVE: To evaluate retinal anatomy using ultrahigh-resolution optical coherence tomography (OCT) in eyes after successful surgical repair of full-thickness macular hole. METHODS: Twenty-two eyes of 22 patients were diagnosed as having macular hole, underwent pars plana vitrectomy, and had flat/closed macular anatomy after surgery, as confirmed with biomicroscopic and OCT examination findings. An ultrahigh-resolution-OCT system developed for retinal imaging, with the capability to achieve approximately 3-microm axial resolution, was used to evaluate retinal anatomy after hole repair. RESULTS: Despite successful closure of the macular hole, all 22 eyes had macular abnormalities on ultrahigh-resolution-OCT images after surgery. These abnormalities were separated into the following 5 categories: (1) outer foveal defects in 14 eyes (64%), (2) persistent foveal detachment in 4 (18%), (3) moderately reflective foveal lesions in 12 (55%), (4) epiretinal membranes in 14 (64%), and (5) nerve fiber layer defects in 3 (14%). CONCLUSIONS: With improved visualization of fine retinal architectural features, ultrahigh-resolution OCT can visualize persistent retinal abnormalities despite anatomically successful macular hole surgery. Outer foveal hyporeflective disruptions of the junction between the inner and outer segments of the photoreceptors likely represent areas of foveal photoreceptor degeneration. Moderately reflective lesions likely represent glial cell proliferation at the site of hole reapproximation. Thin epiretinal membranes do not seem to decrease visual acuity and may play a role in reestablishing foveal anatomy after surgery.

Aged↗

Improved resolution in the detection of oligonucleotides up to 60-mers in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry using pulsed-delayed extraction with a simple high voltage transistor switch.

Pulsed-delayed extraction using a simple high voltage transistor switch together with various sample purification approaches were used to enhance the resolution in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) of oligonucleotides up to 60 bases long. This switch can provide a 0-3 kV voltage pulse with a 75 ns fall time. A resolution of 500-900 was typically observed for samples from 5-mers to 60-mers using pulsed-delayed extraction (PDE) with the switch described herein. The resolution deteriorated to < 100 for oligonucleotides of > or = 65-mers. With the TOF acceleration region configuration used in this work, the resolution was found not to vary significantly over a delay range of 2-5 mus. As the DNA size increased to over 35-mer, HPLC purification was required to retain the enhancement in resolution provided by PDE MALDI-MS.

Chromatography, High Pressure Liquid↗

Resolution enhancement in single-shot imaging using simultaneous acquisition of spatial harmonics (SMASH).

Spatial resolution in single-shot imaging is limited by signal attenuation due to relaxation of transverse magnetization. This effect can be reduced by minimizing acquisition times through the use of short interecho spacings. However, the minimum interecho spacing is constrained by limits on gradient switching rates, radiofrequency (RF) power deposition and RF pulse length. Recently, simultaneous acquisition of spatial harmonics (SMASH) has been introduced as a method to acquire magnetic resonance images at increased speeds using a reduced number of phase-encoding gradient steps by extracting spatial information contained in an RF coil array. In this study, it is shown that SMASH can be used to reduce the effects of relaxation, resulting in single-shot images with increased spatial resolution without increasing imaging time. After a brief theoretical discussion, two strategies to reduce signal attenuation and increase spatial resolution in single-shot imaging are introduced and their performance is evaluated in phantom studies. In vivo single-shot echoplanar imaging (EPI), BURST, and half-Fourier single-shot turbo spin-echo (HASTE) images are then presented demonstrating the practical implementation of these resolution enhancement strategies. Images acquired with SMASH show increased spatial resolution and improved image quality when compared with images obtained with the conventional acquisitions. The general principles presented for imaging with SMASH can also be applied to other partially parallel imaging techniques.

Computer Simulation↗

Three-dimensional high-resolution fast spin-echo coronary magnetic resonance angiography.

Due to SNR constraints, current "bright-blood" 3D coronary MRA approaches still suffer from limited spatial resolution when compared to conventional x-ray coronary angiography. Recent 2D fast spin-echo black-blood techniques maximize signal for coronary MRA at no loss in image spatial resolution. This suggests that the extension of black-blood coronary MRA with a 3D imaging technique would allow for a further signal increase, which may be traded for an improved spatial resolution. Therefore, a dual-inversion 3D fast spin-echo imaging sequence and real-time navigator technology were combined for high-resolution free-breathing black-blood coronary MRA. In-plane image resolution below 400 microm was obtained. Magn Reson Med 45:206-211, 2001.

Adult↗

Efficiency in nonenzymatic kinetic resolution.

The Walden memorial at the Technical University in Riga is pictured in the frontispiece to mark the recent centennial of the Walden inversion. This is a rare public monument to key events from the first era of exploration in stereocontrolled synthesis, and may be the only such monument to use the language of organic chemistry expressed at the molecular level. The reaction of racemic substrates with chiral nucleophiles is one of many methods currently known to achieve kinetic resolution, a phenomenon that ranks as the oldest and most general approach for the synthesis of highly enantioenriched substances. The first nonenzymatic kinetic resolutions as well as the original forms of the Walden inversion were studied in the 1890s. All of these investigations were conducted within the first generation following the demonstration that carbon is tetrahedral, and provided abundant evidence that the principles and importance of enantiocontrolled syntheses were understood. However, a reliable, rapid technique to quantify results and guide the optimization process was still lacking. Many decades passed before this problem was solved by the advent of HPLC and GLPC assays on chiral supports, which stimulated explosive growth in the synthesis of nonracemic substances by kinetic resolution. The Walden monument is accessible to passers-by for hands-on inspection as well as for contemplation and learning. In a similar way, kinetic resolution is experimentally accessible and can be thought-provoking at several levels. We follow the story of kinetic resolution from the early discoveries through fascinating historical milestones and conceptual developments, and close with a focus on modern techniques that maximize efficiency.

Journal Article↗

The application of hybrid mass spectrometry/mass spectrometry and high-resolution mass spectrometry to the analysis of fish samples for polychlorinated dibenzo-p-dioxins and dibenzofurans.

A hybrid mass spectrometer operated in low-resolution selected decomposition monitoring (SDM) mode was used for the analysis of whole fish samples for the 2,3,7,8-substituted polychlorinated dibenzo-p-dioxins and poly-chlorinated dibenzofurans (PCDD/Fs). These fish samples were previously analyzed for PCDD/Fs using a high-resolution mass spectrometer following EPA protocols. The hybrid tandem mass spectrometric method using loss of COCl gave similar quantification results to those obtained by high-resolution mass spectrometry and eliminated the interferences attributed to polychlorinated biphenyls that were encountered in the high-resolution mass spectrometric analysis. Comparison of the two methods shows that the high-resolution mass spectrometric method surpasses the tandem mass spectrometric method in other analytical figures of merit, such as detection limit, linearity and reproducibility.

Animals↗

Enhanced efficiency due to the use of achiral additives in the optical resolution of 1-phenylethylamine by its glutaric acid derivative.

Racemic 1-phenylethylamine was optically resolved by its own derivative formed with glutaric acid namely (+)-(R)-N-(1-phenylethyl)glutaramic acid. The amide acid resolving agent was synthesized from (+)-(R)-1-phenylethylamine by N-derivatization. The glutaric acid derivative was the next in a homologous series of dicarboxilic acid derivatized resolving agents of racemic 1-phenylethylamine. Resolution results obtained with the oxalic, malonic, and succinic acid derivatives were previously discussed(1). Each of the above derivative resolving agents could be successfully applied as resolving agents of 1-phenylethylamine. The efficiency of the present optical resolution using (+)-(R)-N-(1-phenylethyl)glutaramic acid resolving agent was remarkably inferior to the results obtained by its shorter chained homologues(1). Use of achiral additives, like urea, thiourea, N-methylurea, and N,N'-dimethylurea caused large increase in the efficiency of the resolution by (+)-(R)-N-(1-phenylethyl)glutaramic acid resolving agent. Precipitated salts obtained in the resolutions performed in the presence of the additives were investigated by thermoanalysis, X-ray powder diffraction, and optical microscopy. Based on the analytical data, the improvement of the resolution results was attributed to the influence of the additives on the crystal nucleation processes of the diasteromeric salts.

Journal Article↗

Effects of anomalous migration and DNA to protein ratios on resolution of equilibrium constants from gel mobility-shift assays.

Numerical resolution of binding constants from data generated by the gel mobility-shift assay is dependent on the experimental resolution of the different ligation states of the DNA. Previously we showed that the populations of the intermediate ligation states at partial saturation with the protein ligand are extremely sensitive to cooperativity (Senear, D. F. and Brenowitz, M. J. Biol. Chem. 1991, 266, 13661-13671). This makes accurate gel mobility-shift data extremely useful to the demonstration of cooperativity. However, the accuracy with which the intermediate ligation state populations are resolved has been questioned. Thus, two additional and related questions are now considered. First, what information is available if the intermediate ligation state populations are not used in the analysis of binding constants. Second, is accurate information obtained from those states under conditions of high DNA concentration. These questions are addressed by using the interactions of the lambda cI repressor protein with the three site operator, OR, and the interaction of the E. coli GalR protein with the single site operator, OE. Both simulated and experimental data are analyzed. The results point to two conclusions. First, precise resolution of all macroscopic constants for binding of proteins to DNA is critically dependent on the intermediate ligation state populations; resolution is limited to at most two DNA sites if these states are not used in the analysis. Second, when the DNA and protein concentrations used in the titrations are comparable, the resolution of binding constants is extremely sensitive to experimental uncertainty in the macromolecule concentrations.

Binding Sites↗

Improved resolution with microchip-based enhanced field inversion electrophoresis.

We present an improvement of the field inversion electrophoresis (FIE) method in which the passage of sample such as DNA back and forth within a short length of a microchannel can provide a similar resolution to that of a significantly longer microchannel. In constant field FIE the application of an alternating potential (e.g., +/- V) over short periods of time (e.g., several Hz) can provide enhanced separations of DNA fragments. In contrast, the present method consists of a series of separations, each of much longer duration, under high and low fields in such a way that the resolution is enhanced. This method is readily modeled and allows improved resolution to be obtained from extremely short microchannels (e.g., 8 mm) while requiring relatively low applied voltages (e.g., less than 600 V). An additional advantage is that this method can allow for the same equipment to be used in a rapid, low-resolution mode or in a slower, high-resolution mode through what might be referred to as an automated "zoom" capability. We believe that this method may facilitate the integration of microfluidic devices and microelectronic devices by allowing these devices to be of a similar small scale (< 1 cm).

DNA↗

Capillary zone electrophoresis with a dynamic double coating for analysis of carbohydrate-deficient transferrin in human serum: impact of resolution between disialo- and trisialotransferrin on reference limits.

Capillary electrophoresis with a dynamic double coating formed by charged polymeric reagents represents a very effective tool for the separation of iron-saturated transferrin (Tf) isoforms and thus the determination of carbohydrate-deficient transferrin (CDT) in human serum. The resolution between di- and trisialo-Tf is dependent on the applied voltage and capillary temperature. With a 50 microm inside diameter (ID) capillary of about 60 cm total length mounted into the P/ACE MDQ, 28 kV and 40 degrees C, the resolution of the two Tf isoforms is shown to be between 1.0 and 1.4, whereas with reduced voltage and/or temperature, increased resolution at the expense of elongated run times is observed. Best data with complete resolution (Rs > or = 1.4) are obtained at 20 kV and 30 degrees C. For the determination of CDT in serum, incomplete separation of di- and trisialo-Tf is demonstrated to have an impact on the reference limits. Analysis of the sera of 54 healthy individuals with no or moderate alcohol consumption and using valley-to-valley peak integration, the upper (lower) reference limits for CDT in relation to total Tf at the two power levels are 1.33 (0.52) and 1.57 (0.81)%, respectively, representing intervals that are significantly different (P < 0.001). Furthermore, the reference intervals are shown to be strongly dependent on the peak integration approach used. Valley-to-valley peak integration should only be employed for conditions with complete resolution between disialo- and trisialo-Tf.

Blood Chemical Analysis↗

Effects of G-quartet DNA stationary phase destabilization on fibrinogen peptide resolution in capillary electrochromatography.

The migration of fibrinogen peptides in capillaries coated with G-quartet-forming DNA oligonucleotides in open-tubular CEC (OTCEC) was studied, in order to investigate factors affecting the retention of peptides on G-quartet DNA stationary phases. At 25 degrees C, the peptides eluted in the same order in OTCEC using a two-plane G-quartet DNA stationary phase as in CZE, including two peptides that were completely overlapped. It was found that baseline resolution of the coeluting peptides could be achieved in the OTCEC experiment, but not in CZE, at run temperatures of 35-40 degrees C. A stationary phase formed by a scrambled-sequence oligonucleotide that does not form a G-quartet did not provide any resolution of the two coeluting peptides, even at the higher temperatures, indicating that some destabilization of the G-quartet enhances resolution but that some degree of G-quartet structure is necessary. The effects of destabilization were further explored through variation of the cations (sodium or potassium) used in attachment of the G-quartet oligonucleotide to the capillary surface and in the mobile-phase buffer. Resolution was lower when a more stable, four-plane G-quartet stationary phase was used, supporting the conclusion that some flexibility in the G-quartet structure facilitates differential interactions that resolve otherwise coeluting peptides. The increase in peptide resolution upon destabilization of the G-quartet structure could prove to be an important factor in the application of G-quartet DNA stationary phases for nonaffinity-based separation of native proteins and peptides.

Amino Acid Sequence↗

Practical limits of resolution in confocal and non-linear microscopy.

Calculated and measured resolution figures are presented for confocal microscopes with different pinhole sizes and for nonlinear (2-photon and second harmonic) microscopes. A modest degree of super-resolution is predicted for a confocal microscope but in practice this is not achievable and confocal fluorescence gives little resolution improvement over widefield. However, practical non-linear microscopes do approach their theoretical resolution and therefore show no resolution disadvantage relative to confocal microscopes in spite of the longer excitation wavelength.

Animals↗

Molecular recognition in synthetic polymers. Enantiomeric resolution of amide derivatives of amino acids on molecularly imprinted polymers.

Molecular imprints were prepared using L-phenylalanine anilide as the print molecule and methacrylic acid as the functional monomer. Methacrylic acid interacts ionically with the primary amine of the print molecule and via hydrogen bonding with the amide function. In the HPLC mode such polymers were shown to exhibit efficient enantiomeric resolution of a racemic mixture of the original print molecule. Enantiomeric resolution was shown to be dependent on the ratio of methacrylic acid to print molecule in the pre-polymerization mixture and specific for the presence of both print molecule and functional monomer. Further analyses showed the importance of both the primary amino and amide functions in the correct stereochemistry for recognition and enantiomeric resolution of compounds on such polymers. Other amide derivatives of amino acids including p-nitroanilides, beta-naphthylamides and amides were recognized by such polymers, and enantiomeric resolution was obtained for amide derivatives of amino acid ranging from alanine to tryptophan on a single polymer. The implications of these findings with respect to the mechanism of recognition and the ability to predict enantiomeric resolution of molecules on molecularly imprinted polymers will be discussed.

Amino Acids↗

High-resolution three-dimensional MR angiography of rodent tumors: morphologic characterization of intratumoral vasculature.

PURPOSE: To evaluate high-resolution three-dimensional MR angiography (MRA) for the visualization and morphologic characterization of intratumoral vasculature. MATERIALS AND METHODS: Two subcutaneous rodent tumor models (human skin carcinoma HaCaT-ras-A-5RT3 grown in nude mice and rat prostate carcinoma R3327-AT1 grown in Copenhagen rats) were examined with a clinical 1.5 T MR-system. For MRA a dedicated high-resolution three-dimensional gradient echo pulse sequence with a voxel size of 166 x 206 x 320 microm(3) was performed after injection of Gadomer-17. The image analysis included a correlation of intratumoral vessels with histology. Signal intensity measurements were performed in the vena cava, the tumor underlying muscle, and in various regions of the tumor. Signal-to-noise-ratios (SNR) and contrast-to-noise-ratios (CNR) were calculated from this measurement. RESULTS: High-resolution MRA allowed a clear distinction of intratumoral blood vessels. The mouse tumor model tended to be strongly vascularized with several intratumoral blood vessels clearly displayed by MRA. When correlated with histology, these intratumoral blood vessels had a size in the range of 300 to 400 microm. In contrast, rat tumors had only sparse capillary intratumoral blood vessels that could only be demonstrated by histology. In both tumor models, dilated blood vessels were observed in the subcutaneous tissue near the tumor. In general, areas with a strong contrast enhancement correlated with viable, well vascularized tumor regions, whereas non-enhancing tumor areas correlated with tumor necrosis or hypoxic areas. CONCLUSION: High-resolution three-dimensional MRA allows the visualization of intratumoral vasculature in rodent models. With minimal hardware and software modifications, high-resolution MRA could be performed on a clinical 1.5 T MRI scanner. Morphologic characterization of intratumoral blood vessels could add important insights into the process of tumor angiogenesis.

Animals↗

Spatial resolution of numerical models of man and calculated specific absorption rate using the FDTD method: a study at 64 MHz in a magnetic resonance imaging coil.

PURPOSE: To examine how fine a model resolution is necessary for calculation of specific energy absorption rate (SAR) for the human head in regions as small as 1 g. MATERIALS AND METHODS: Here we perform a simple study comparing the maximum SAR averaged over any 1 cm(3) and SAR averaged over the entire head for several models of the same human head within the same radiofrequency coil, but with spatial resolutions varying from 8-100 Yee cells per cm(3). RESULTS: Over the range of model resolutions from 8-100 Yee cells per cm(3), there is only a 16% variation in maximum SAR in any 1 cm(3) of tissue in the head, and only a 7% variation in SAR averaged over the entire head. CONCLUSION: While it is always desirable to perform SAR calculations with the greatest possible accuracy, in calculations of the maximum SAR levels in any 1 cm(3) of tissue, spatial resolutions greater than 5 mm may not yield notably different results than those with a spatial resolution of 5 mm.

Head↗

Fast and high-resolution MR sialography using a small surface coil.

PURPOSE: To establish a fast and high-resolution MR sialographic technique that provides fast and high-resolution imaging. MATERIALS AND METHODS: MR sialography was performed on a 1.5-T MR imager using a small (47-mm) surface coil. We determined appropriate sequence parameters, and then applied the technique to the salivary glands of 143 patients with xerostomia (including those with Sjögren's syndrome or hyperlipidemia) or salivary gland inflammation. We compared the high-resolution MR sialography with conventional x-ray sialography in the patients with xerostomia to evaluate the effectiveness of the MR sialography technique. RESULTS: We found that a single-shot, single-slice MR sialography (TR/TR/number of signal acquisitions [NSA] = 8000 msec/1000 msec/6) using a small surface coil provides excellent duct images that are clinically feasible with fast (imaging time of 56 seconds) and high-resolution images. An alternative three-dimensional MR sialography technique provided better details of the branches at the expense of imaging time. The MR sialography technique using a small surface coil depicted effectively the ductal changes in the salivary glands in patients with or without Sjögren's syndrome, reflecting the severity of the diseases. CONCLUSION: We conclude that MR sialography can be performed using a fast and high-resolution sequence.

Adult↗

Perfusion-based high-resolution functional imaging in the human brain at 7 Tesla.

Perfusion-based MRI measures cerebral blood flow (CBF) at the capillary level and can be used for functional studies based on the tight spatial coupling between brain activity and blood flow. Obtaining functional CBF maps with high spatial resolution is a major challenge because the CBF signal is intrinsically low and the SNR is critical. In the present work, CBF-based functional imaging was performed at a considerably smaller voxel size than previously reported in humans. High-resolution CBF maps were obtained with voxel sizes as small as 0.9 x 0.9 x 1.5 mm(3) in the human brain. High sensitivity was made possible by signal-to-noise gains at the high magnetic field of 7 T and by using a novel RF combination coil design. In addition, a reduction of the field-of-view was critical to achieve 0.9-mm in-plane resolution with gradient-echo echo-planar imaging in a single shot. Functional CBF data were compared with functional BOLD data to reveal that, for CBF, large contrast- to-noise gains were obtained at high spatial resolution, indicating that the functional CBF response was more localized. High-resolution functional CBF imaging is significant for neuroscience research because it provides better localization and more specific information than BOLD for monitoring brain function.

Cerebrovascular Circulation↗