Optimization of extraction conditions for low-molecular-weight analytes using solid-phase microextraction

A group of volatile analytes under a molecular weight of 90 and representing 11 organic classes are extracted using identical conditions with 6 different solid-phase microextraction fiber coatings. The amount of each of the analytes extracted by the various fibers is shown. The effects of sample modifiers, such as pH and ionic strength, on the recovery of the analytes are presented. A comparison of headspace and immersion extraction techniques is shown.

Journal Article↗

[Solid-phase microextraction coupled with capillary electrophoresis for doping analysis of propranolol enantiomers in urine using a sol-gel derived calix [4] arene fiber].

A new type fiber coated with diglycidyloxy calix [4] arene/hydroxy-terminated silicone oil (diglycidyloxy-C [4] arene/OH-TSO) made by sol-gel method was prepared for capillary electrophoresis (CE) sample pretreatment. By using headspace solid-phase microextraction (HS-SPME) combined with a novel back-extraction facility coupled off-line to capillary zone electrophoresis (CZE), the determination of propranolol enantiomers in urine was achieved with combination of ultrasonic back-extraction and field amplified sample injection (FASI) technologies. Extraction and back-extraction parameters were optimized. The clean-up effect and preconcentration effect were realized without derivatization during the SPME process in terms of this strongly polar and thermally stable compound. Preconcentration of the sample by calix [4] arene fiber increased the sensitivity, yielding a limit of detection (LOD) of 0.01 mg/L by CZE-diode array detection (DAD). Method repeatability (relative standard deviations (RSD) < 6.5%) and fiber reusability (> 150 extraction procedures) were observed over a wide linear range of propranolol (0.05 - 10 mg/L) in urine samples. Compared with commercial SPME stationary phases, the new coating showed higher extraction efficiency and this SPME-CZE-DAD procedures could meet the demand of minimum required performance limits (MRPL) set by the World Anti-Doping Agency (WADA) for the detection of propranolol in urine samples.

Animals↗

Headspace solid-phase microextraction for characterization of fragrances of lemon verbena (Aloysia triphylla) by gas chromatography-mass spectrometry.

Natural fragrances from lemon verbena (Aloysia triphylla) were studied by headspace solid phase microextraction (HS-SPME) techniques followed by gas chromatography-mass spectrometry (GC-MS), with six different fibre coatings being tested to evaluate the extraction efficiencies of several selected compounds. A total of 14 compounds were identified in the fragrances of lemon verbena. Geranial and neral were detected as major components and alpha-pinene, beta-pinene, beta-caryophyllene, and curcumene as minor components. Enantiomeric analysis of chiral compounds from lemon verbena was carried out on a chiral column. alpha-Pinene, limonene, and camphor in the fragrances emitted from lemon verbena were found in the (+), (-), and (-) forms, respectively.

Bicyclic Monoterpenes↗

Automated sample preparation using in-tube solid-phase microextraction and its application -- a review.

Sample preparation, such as extraction, concentration, and isolation of analytes, greatly influences their reliable and accurate analysis. In-tube solid-phase microextraction (SPME) is a new effective sample preparation technique using an open tubular fused-silica capillary column as an extraction device. Organic compounds in aqueous samples are directly extracted and concentrated into the stationary phase of capillary columns by repeated draw/eject cycles of sample solution, and they can be directly transferred to the liquid chromatographic column. In-tube SPME is an ideal sample preparation technique because it is fast to operate, easy to automate, solvent-free, and inexpensive. On-line in-tube SPME-performed continuous extraction, concentration, desorption, and injection using an autosampler, is usually used in combination with high performance liquid chromatography and liquid chromatography-mass spectrometry. This technique has successfully been applied to the determination of various compounds such as pesticides, drugs, environmental pollutants, and food contaminants. In this review, an overview of the development of in-tube SPME technique and its applications to environmental, clinical, forensic, and food analyses are described.

Automation↗

Fiber-in-tube solid-phase microextraction: a fibrous rigid-rod heterocyclic polymer as the extraction medium.

A novel "fiber-in-tube" configuration has been applied to the extraction tube of solid phase microextraction (SPME), and the direct coupling of the extraction process to liquid chromatography (LC) has been accomplished for the analysis of n-butylphthalate in wastewater. By using this fiber-in-tube SPME/LC system the preconcentration factor for the phthalate was about 160 with 20 min extraction and no interference peak was observed in the chromatogram. The results also showed the potential applications of this fiber-in-tube SPME/LC for the analysis of sub-ppb level (i.e., lower than 1 ng/mL) of various organic analytes in aqueous sample matrix without a large solvent consumption during the preconcentration process.

Journal Article↗

Analysis of total propionic acid in feed using headspace solid-phase microextraction and gas chromatography.

A method is described to analyze total propionic acid content (free propionic acid + sodium, ammonium, calcium salts, etc.) in feed, using headspace solid-phase microextraction (HS-SPME) of a feed suspension in salted and acidified water. Optimization of the extraction variables was done by simplex method after choosing a polyacrilate fiber to enhance the response of this acid. Separation was made by capillary gas chromatography (GC), using a special free fatty acid phase (FFAP) column for acids and a flame ionization detector (FID). Some of the chromatograms were also done, injecting the SPME fiber in a GC-mass spectrometry (MS) system, working with some specific ions for propionic acid, to be selective enough to avoid confusing the propionic acid peak with interferences of those complex matrixes. The method was tested for linearity and repeatability. Detection and quantification limits were also calculated. The method was applied to commercial feed samples, very variable in composition, quantifying by standard addition method. No major interferences were observed.

Animal Feed↗

Determination of aromatic hydrocarbons in asphalt release agents using headspace solid-phase microextraction and gas chromatography-mass spectrometry.

The possibility of quantitative analysis of aromatic hydrocarbons in oil-based asphalt release agents was investigated using headspace solid-phase microextraction (HS-SPME) followed by gas chromatography-mass spectrometry (GC-MS). The target analytes studied were benzene, toluene, ethylbenzene, p-, m-, and o-xylene (BTEX) and 1,3,5-trimethylbenzene and 1,2,4-trimethylbenzene. Experimental parameters influencing HS-SPME efficiency were studied (equilibration time between sample and headspace and between headspace and SPME fiber, sample amount and sample matrice effects). A HS-SPME method using hexadecane as a surrogate matrice was developed. The detection limit was estimated as 0.03-0.08 ppm (w/w) for the target analytes investigated. Good linearity was observed (R2 > 0.999) for all calibration curves at high, medium and low concentration level. The repeatability of the method (RSD, relative standard deviation) was found to be less than 10% (generally less than 5%) in triplicate samples and approximately 2% at eight consecutive tests on one and the same sample. The accuracy of the method given by recovery of spiked samples was between 85 and 106% (generally between 95 and 105%). The HS-SPME method developed was applied to four commercially available asphalt release agents. External calibration and standard addition approaches were investigated regarding accuracy. The results showed that standard addition generates higher accuracy than external calibration. The contents of target aromatic hydrocarbons in the asphalt release agents studied varied greatly from approximately 0.1-700 ppm. The method described looks promising, and could be a valuable tool for determination of aromatic hydrocarbons in different types of organic matrices.

Benzene↗

Rapid determination of butyltin species in water samples by multicapillary gas chromatography with atomic emission detection following headspace solid-phase microextraction.

A procedure for the rapid determination of mono-, di- and tributyltin in water samples is described. The analytes are simultaneously ethylated and concentrated on a solid-phase microextraction fibre placed in the headspace over the sample for 2 min. The ethylated species are then separated and selectively quantified in only 90 s using a multicapillary gas chromatography column combined with atomic emission detection. The influence of blank signals and sampling conditions on the sensitivity of the method is described. Detection limits of 1-5 ng/l and relative standard deviations of 6-10% at concentrations of 20 ng/l were obtained.

Chromatography, Gas↗

Method based on solid-phase microextraction--high-performance liquid chromatography with UV and electrochemical detection to determine estrogenic compounds in water samples.

We determined a group of estrogenic compounds by solid-phase microextraction (SPME) coupled to high-performance liquid chromatography (HPLC) with both ultraviolet (UV) and electrochemical detection (ED). A modified liquid chromatograph was used. Polyacrylate fibers (85 microns) were used to extract the analytes from the aqueous samples. Dynamic and static modes of desorption were compared and the variables affecting both absorption and desorption processes in SPME-HPLC were optimized. Static desorption gave the best recoveries and peak shapes. The performance of the SPME-HPLC-UV-ED method was checked with river water and wastewater. The method enabled estrogenic compounds to be determined at low-microgram l-1 levels in real water samples. Limits of detection were between 0.3 and 1.1 micrograms l-1 using UV detection and between 0.06 and 0.08 microgram l-1 using ED. beta-Estradiol was found in samples from a wastewater treatment plant at concentrations between 1.9 and 2.2 micrograms l-1.

Chromatography, High Pressure Liquid↗

Headspace solid phase microextraction (SPME) analysis of flavor compounds in wines. Effect of the matrix volatile composition in the relative response factors in a wine model.

The application of headspace solid phase microextraction (SPME) for flavor analysis has been studied. Headspace SPME sampling was tested for nine common wine flavor compounds in 10% (v/v) aqueous ethanol: linalool, nerol, geraniol, 3-methyl-1-butanol, hexanol, 2-phenylethanol, ethyl hexanoate, ethyl octanoate, and ethyl decanoate. The chemical groups (monoterpenoids, aliphatic and aromatic alcohols, and esters) showed specific behavior in SPME analysis. SPME sampling parameters were optimized for these components. Relative response factors (RRFs), which establish the relationship between the concentration of the compound in the matrix liquid solution and the GC peak area, were estimated for all compounds. Log(10)(RRF) varied from 0 (3-methyl-1-butanol) to 3 (ethyl decanoate), according to their molecular weight. Quantification by SPME was shown to be highly dependent on the matrix composition; the compounds with higher RRF were the less affected. As a consequence, the data obtained with this methodology should be used taking into consideration these limitations, as shown in the analysis of four monovarietal Bairrada white wines (Arinto, Bical, Cerceal, and Maria Gomes).

Chromatography, Liquid↗

Optimization of headspace solid-phase Microextraction (SPME) for the odor analysis of surface-ripened cheese.

Fifty volatile compounds of surface smear-ripened cheese were detected and identified using headspace solid-phase microextraction (HS-SPME) and vacuum distillation coupled to gas chromatography-mass spectrometry. Changes in the headspace of aroma compounds were monitored over the whole packaging period (47 days) using the HS-SPME method. Initially, the concentration of methanethiol increased before reaching a plateau. This evolution could be linked to the growth of Brevibacterium linens. During the shelf life of cheese, levels of acetic acid and 3-methylbutanoic acid remained constant, whereas butane-2,3-dione, 3-hydroxybutan-2-one, and hydroxypropan-2-one levels gradually declined and acetone and 3-methylbutanol levels dropped sharply to a plateau. Changes in odor could be related to changes of the rind, which behaved as a barrier, strongly influencing the distribution of volatile compounds in the headspace. Using a gas chromatography-olfactometry technique without separation, it was shown that the SPME extract was representative of the cheese odor.

Brevibacterium↗

Improved malonaldehyde assay using headspace solid-phase microextraction and its application to the measurement of the antioxidant activity of phytochemicals.

A modified malonaldehyde (MA) assay for antioxidant activity, which involves derivatization and headspace solid-phase microextraction (HS-SPME) was developed and validated. The recovery of MA as 1-methylpyrazole (product of MA and N-methylhydrazine) from a headspace of an aqueous solution containing MA, buffer, surfactant, and cod liver oil using HS-SPME with a PDMS/DVB fiber was 91.3 +/- 3.38%. MA was analyzed by a gas chromatograph with a nitrogen-phosphorus detector, and its detection limit was 0.0103 nmol/mL. The antioxidant activities of natural compounds were determined as the percentage inhibition of MA formed from cod liver oil oxidized by Fenton's reagents in the above aqueous solution. Sesamol inhibited MA formation most (86.1%), followed by eugenol (84.4%), capsaicin (80.7%), ethylvanillin (45.3%), and vanillin (31.6%) at a level of 50 microg/mL. This method did not require any organic solvents and is a simple, fast, and a highly sensitive method for MA determination.

Antioxidants↗

Determination of lidocaine in hair of drug fatalities by headspace solid-phase microextraction.

The local anesthetic lidocaine was determined in hair by hydrolysis of the samples with 4% NaOH in the presence of excessive Na2SO4 and subsequent headspace solid-phase microextraction with a 65-microm Carbowax/divinylbenzene fiber, and gas chromatography-mass spectrometry measurement with etidocaine as the internal standard. The calibration curve was linear between 0.1 and 1000 ng/mg. The detection and quantitation limits were 0.1 and 0.4 ng/mg, respectively. The method was applied to hair samples of 49 drug fatalities, and positive results were obtained in 32 cases with lidocaine concentrations between 0.4 and 400 ng/mg and 675 ng/mg in one extreme case. For comparison, morphine, 6-acetylmorphine, codeine, dihydrocodeine, methadone, cocaine, and benzoylecgonine were also determined by usual methods. From segmental investigations in four of the cases and from comparison with the hair concentrations of the other drugs, it follows that lidocaine was consumed for a longer period of time as an adulterant of cocaine and heroin preparations.

Adolescent↗

Traceability of Asiago mountain cheese: a rapid, low-cost analytical procedure for its identification based on solid-phase microextraction.

The traceability of Asiago mountain cheese was established by analyzing samples of herbaceous species, milk, and cheese of mountain origin using the head-space solid-phase microextraction sampling procedure coupled with gas chromatography-mass spectrometry. As preliminary work had highlighted the characteristic presence of sesquiterpenes in Asiago mountain cheese, these species were considered effective markers of mountain origin. Systematic qualitative analysis, carried out using a carboxen/polydimethylsiloxane fiber, revealed several sesquiterpenes in mountain herbage and milk, in particular beta-caryophyllene and alpha-humulene, in Asiago mountain cheese, confirming sesquiterpenes as markers of cheese produced from animals grazing on mountain pastures. Analysis was performed on 19 samples of herbage, 8 of milk, and 8 of cheese, collected in summer from 4 mountain farms on the Asiago plateau. For quantitative analysis of caryophyllene in cheese, polydimethylsiloxane fiber sampling, coupled with the standard addition method to eliminate matrix effect, was preferred. The amount of beta-caryophyllene found ranged from 21 to 65 microg/kg.

Altitude↗

Determination of organochlorine pesticides and polychlorinated biphenyls in human serum using headspace solid-phase microextraction and gas chromatography-electron capture detection.

A simple procedure for the determination of organochlorine pesticides (OCPs) and polychlorinated biphenyls (PCBs) in human serum using headspace solid-phase microextraction (HS-SPME) was developed. The analysis was carried out by gas chromatography (GC) equipped with electron capture detector (ECD). A 2(7-4) Plackett-Burman reduced factorial design for screening and a central composite design for optimizing the significant variables were applied. A 100 microm PDMS fiber, 3/5 headspace ratio (3 ml in 5 ml vial), 85 degrees C extraction temperature, 50 min extraction time, and 1 ml of acidic solution (pH 3) added to 1 ml of diluted serum (1:1) were chosen for the best response in HS extraction mode. The detection limits found were from 1 pg/ml (PCB 167) to 52 pg/ml (beta-HCH), the relative standard deviation for the procedure varied from 3% (PCB 52) to 12% (PCB 189) and the accuracy was checked by using validated solid-phase extraction (SPE) procedure. The method that avoids the use of clean-up steps and the hazardous solvents enabled reliable determinations of the OCPs and the PCBs except beta-HCH. The method was applied to the analysis of 33 human serum samples. The most abundant target compound was p-p'-DDE (range, 0.3-8.0 ng/ml; median value, 2.1 ng/ml). Among the PCBs the prevalent congeners were 138, 153 and 180.

Gas Chromatography-Mass Spectrometry↗

Determination of anatoxin-a in environmental water samples by solid-phase microextraction and gas chromatography-mass spectrometry.

In the present work, a method was developed and optimized aiming at the determination of anatoxin-a in environmental water samples. The method is based on the direct derivatization of the analyte by adding hexylchloroformate in the alkalinized sample (pH = 9.0). The derivatized anatoxin-a was extracted by a solid-phase microextraction (SPME) procedure, submersing a PDMS fiber in an amber vial for 20 min under magnetic stirring. GC-MS was used to identify and quantify the analyte in the SIM mode. Norcocaine was used as internal standard. The following ions were chosen for SIM analyses (quantification ions in italics): anatoxin-a: 191, 164, 293 and norcocaine: 195, 136, 168. The calibration curve showed linearity in the range of 2.5-200 ng/mL and the LOD was 2 ng/mL. This method of SPME and GC-MS analysis can be readily utilized to monitor anatoxin-a for water quality control.

Bacterial Toxins↗

Determination of phenothiazines in human body fluids by solid-phase microextraction and liquid chromatography/tandem mass spectrometry.

Eleven phenothiazine derivatives with heavy side-chains were found to be extractable from human whole blood and urine samples by solid-phase microextraction (SPME) with a polyacrylate-coated fiber. The fiber was then injected into the desorption chamber of an SPME-liquid chromatography (LC) interface for LC/tandem mass spectrometry (MS/MS) with positive ion electrospray (ES) ionization. All compounds formed base peaks due to [M + 1](+) ions by LC/ES-MS/MS. By use of LC/ES-MS/MS, the product ions produced from each [M + 1](+) ion showed base peaks due to side-chain liberation. Selected reaction monitoring (SRM) and selected ion monitoring (SIM) were compared for the detection of the 11 phenothiazine derivatives from human whole blood and urine. SRM showed much higher sensitivity than SIM for both types of sample. Therefore, a detailed procedure for the detection of drugs by SRM with SPME-LC/MS/MS was established and carefully validated. The extraction efficiencies of the 11 phenothiazine derivatives spiked into whole blood and urine were 0. 0002-0.12 and 2.6-39.8%, respectively. The regression equations for the 11 phenothiazine derivatives showed excellent linearity with detection limits of 0.2-200 ng ml(-1) for whole blood and 4-22 pg ml(-1) for urine. The intra- and inter-day precisions for whole blood and urine samples were not greater than 15.1%. The data obtained after oral administration of perazine or flupentixol to a male subject are presented.

Adult↗

A novel headspace solid-phase microextraction method for the exact determination of organochlorine pesticides in environmental soil samples.

A novel method of determining organochlorine pesticides (OCPs) is described. It is based on solid-phase microextraction (SPME) and gas chromatography-electron capture detection. During the development of the method, soil samples were prepared, spiked with standard solution, and then aged for some time. Extraction conditions such as the extraction time, the NaCl content, the volume of water, the extraction temperature and the desorption time were investigated and optimized. The limits of detection obtained using the method ranged from 0.10 to 0.51 ng g(-1), and relative standard deviations were lower than 10% for most organochlorine pesticides. Real soil samples were successfully analyzed using the proposed method. The results from the method developed here were in good agreement with those obtained using ultrasonic extraction. The result demonstrates that aging soils spiked with standard solution is an important method development step, because the soil samples obtained using this approach are more like real soils than those obtained when aging is not used.

Adsorption↗