[Retrieval and failure analysis of surgical implants in Brazil: the need for proper regulation].

This paper summarizes several cases of metallurgical failure analysis of surgical implants conducted at the Laboratory of Failure Analysis, Instituto de Pesquisas Tecnológicas (IPT), in Brazil. Failures with two stainless steel femoral compression plates, one stainless steel femoral nail plate, one Ti-6Al-4V alloy maxillary reconstruction plate, and five Nitinol wires were investigated. The results showed that the implants were not in accordance with ISO standards and presented evidence of corrosion-assisted fracture. Furthermore, some of the implants presented manufacturing/processing defects which also contributed to their premature failure. Implantation of materials that are not biocompatible may cause several types of adverse effects in the human body and lead to premature implant failure. A review of prevailing health legislation is needed in Brazil, along with the adoption of regulatory mechanisms to assure the quality of surgical implants on the market, providing for compulsory procedures in the reporting and investigation of surgical implants which have failed in service.

Biocompatible Materials↗

Hydroxyapatite and fluor-hydroxyapatite layered film on titanium processed by a sol-gel route for hard-tissue implants.

A double-layered coating, consisting of a hydroxyapatite (HA) outer film and a fluor-hydroxyapatite (FHA) inner film, was produced on a Ti substrate by a sol-gel route to improve the biocompatibility and functionality of the system. Dissolution behavior of and in vitro cellular responses to the layered film were investigated. Calcium nitrate and triethyl phosphite were used for calcium and phosphate precursors, respectively, and ammonium fluoride was added as a fluorine-ion source for FHA. The FHA layer was deposited on Ti by spin coating and subsequent heat treatment at 550 degrees C for 30 min in air, and then the HA layer was laid down over the FHA-coated Ti under the same conditions. After heat treatment, characteristic apatite structures and phases were developed on both FHA and HA films. The cross-section view of the HA/FHA film clearly showed a double-layered structure on Ti with each layer approximately 0.6-0.8-microm thickness. The coating layer was highly uniform and dense, and adhered to Ti substrate strongly with an adhesion strength of about 40 MPa. The in vitro solubility of the HA/FHA layered film in a physiological solution was between that of HA and FHA pure film, and the dissolution profile was quite biphasic, that is, an initial rapid period and a slowdown with increasing time, reflecting the gradient solubility of the fast HA outer structure/slow FHA inner structure. The human osteoblast-like HOS TE85 cells cultured on the HA/FHA layered film attached, spread, and grew favorably. The proliferation rate of the cells on the layered film was significantly higher (considered at p < 0.05 for n = 6) than that on Ti substrate and was similar to that on pure HA film. The alkaline phosphatase (ALP) activity and osteocalcin (OC) produced by the cells on the layered film were significantly higher (considered at p < 0.05 for n = 6) than those on Ti substrate. Moreover, the ALP and OC levels of cells on the layered film showed the trends of HA outer/FHA inner structure with respect to culture period, that is, HA initially and FHA later. These observations suggest that the HA/FHA layered film on Ti obtained by a sol-gel route possesses gradient functionality in terms of solubility and cellular responses, and find that those parameters can be tailored for specific use in hard-tissue implants.

Biocompatible Materials↗

Initial contact angle measurements on variously treated dental/medical titanium materials.

The cell attachment to bioapplicable titanium surfaces is an important parameter in the area of clinical implant dentistry and medicine. A major consideration in designing implants has been to produce surfaces that promote desirable responses in the cells and tissues contacting the implants. In this study, three titanium materials (commercially pure titanium - CPT -, Ti-6Al-4V, and TiNi) were treated mechanically, chemically, mechano-chemically, and thermally to produce concave surfaces with varying roughness. Using four media (distilled water, 1% NaCl aqueous solution, a suspension of human neutrophils, and a suspension of the MG-63 osteoblast-like cells), the initial contact angles were measured. Six readings (three drops each measured by two observers) were collected for each material and for each medium. The interclass correlation coefficients were used for the group comparisons. A one-way analysis of variance (ANOVA) and Tukey's HSD (honestly significant difference) statistical analyses were employed. It was found, for CPT, that (1) statistically, there were no significant differences among four media in contact angles, (2) the contact angle increased linearly with average roughness when the angles were higher than 45 degrees, and (3) the contact angle decreased linearly with roughness when the angle was less than 45 degrees.

Alloys↗

Surface analysis of failed oral titanium implants.

The aim of the present study was to investigate the surface topography, composition, and oxide thickness of consecutively failed, oral Brånemark implants in order to determine possible causes for failure. The failure criterion was lack of osseointegration manifested as implant mobility. Ten implants were retrieved before loading (early failures) and 12 during a period of function up to 8 years (late failures). At retrieval, early losses did not display any clinical sign of infection. All late failures were radiographically characterized by peri-implant radiolucency and did not show infectious signs with one exception. No implant seemed to be lost due to peri-implantitis (plaque-induced progressive marginal bone loss). Twelve implants were analyzed by scanning electron microscopy (SEM), Auger electron spectroscopy (AES), and depth profiling using a blind protocol. Two pristine fixtures, which underwent the same preparation as the failed implants, were used as controls. In the SEM, control samples were essentially free from macroscopic contamination, whereas failed implants contained varying amounts of tissue residues. AES showed that all surfaces consisted of Ti oxide and varying amounts of additional elements, with C dominating in most cases. Nitrogen and sometimes Na, Ca, P, Cl, S, and Si were detected. The Si contamination was most likely due to ion leaching from the glass vials used for storage. Depth profiles showed a typical oxide thickness of 5-8 nm for all samples. In conclusion, no significant changes in the oxide layer composition or thickness as a result of implantation were observed. The results do not indicate any material-related cause for the failures of these implants. Possible reasons for these failures were impaired healing, asymptomatic infection, and overload.

Adult↗

The effect of operative fit and hydroxyapatite coating on the mechanical and biological response to porous implants.

UNLABELLED: Femoral intramedullary implants were constructed by threading 4.0-millimeter-thick disks with a titanium-alloy (Ti-6Al-4V) porous bead coating onto a two-millimeter-diameter threaded rod. Each porous-coated disk, which was 6.0, 8.0, 9.0, or 10.0 millimeters in diameter, was separated by a two-millimeter-thick acrylic disk with a diameter of ten millimeters. Implants with and without a hydroxyapatite coating of twenty-five micrometers were inserted into fifteen skeletally mature adult mongrel dogs. The femoral canal was sequentially reamed bilaterally to a ten-millimeter diameter, resulting in uniform initial implant-bone interface gaps of 0.0, 0.5, 1.0, and 2.0 millimeters. Each animal received paired hydroxyapatite-coated and uncoated implants. Three animals each were killed at four, eight, twelve, twenty-four, and fifty-two weeks after the implantation. The harvested femora were sectioned through the acrylic spacers, transverse to the long axis, to produce individual push-out test specimens for mechanical testing. Characteristics of interface attachment were determined with test fixtures that supported the surrounding bone to within 150 micrometers of the interface. Histological sections were prepared, and the amount of bone within the porous structure and the amount of the original gap that was filled with new bone were quantified with a computerized video image-analysis system. Mechanical attachment strength and bone ingrowth were found to increase with the time after implantation and with a decrease in the size of the gap. Placement of the implant in proximal (cancellous) compared with distal (cortical) locations had no significant effect on the strength of attachment, bone ingrowth, or gap-filling. However, implants with a large initial gap (1.0 or 2.0 millimeters) demonstrated greater attachment strength in cancellous bone than in cortical bone. With a few exceptions, hydroxyapatite-coated implants with an initial gap of 1.0 millimeter or less demonstrated significantly increased mechanical attachment strength and bone ingrowth at all time-periods. Interface attachment strengths were positively correlated with bone ingrowth, the time after implantation, the use of a hydroxyapatite coating, and decreasing initial gap size. CLINICAL RELEVANCE: Initial implant-bone apposition is thought to be a prerequisite for good biological fixation. This apposition is often not achieved because of the design of the implant or instruments and the operative technique. Poor initial fit during the operation may decrease the longevity of the implant. The results of the present study indicate that attachment strength and bone ingrowth are significantly affected by gaps in the interface, particularly those of more than 1.0 millimeter.(ABSTRACT TRUNCATED AT 400 WORDS)

Alloys↗

In vitro crevice corrosion behavior of implant materials.

The crevice corrosion susceptibility of cold-worked Type 316LVM stainless steel, cast Co-Cr-Mo, wrought Co-Cr-W-Ni, non-nitrided and nitrided Ti-6Al-4V ELI, and c.p. Ti, Grades 1 and 4, was studied in vitro by means of a crevice cell. Occlusion was created by interfacing a disc specimen and a Teflon bar. Specimens were mechanically prepared through 2-4 micron Al2O3 and passivated in 30% HNO3, followed by steam sterilization. Tests were performed in a deaerated Ringer's solution, maintained at pH = 7 and 37 degrees C. Anodic polarization was conducted potentiostatically at pre-selected levels, and resultant currents were monitored: stainless steel, 50 and 100 mV (S.C.E.), 450 min; non-stainless materials, 600 mV, 1000 min. Results for the stainless steel demonstrated that a HNO3 passivation treatment reduced its crevice corrosion susceptibility. For the non-stainless steel materials, no crevice corrosion susceptibility was observed, although a dulling and discoloration of c.p. Ti was evident. Recognizing that 600 mV is in excess of the O2 reduction potential in vivo, it was concluded that, in the absence of fretting, implants of these non-stainless steel materials would not experience significant corrosion loss under crevice conditions.

Aluminum↗

Stretch-mediated responses of osteoblast-like cells cultured on titanium-coated substrates in vitro.

Cyclic stretching experiments on osteoblast-like cells have proven to be a useful tool in understanding the underlying mechanisms of load transduction at the bone-implant surface. However, most experimental setups use silicone rubber substrates, which are atypical for orthopedic and dental implant materials. Therefore, we investigated the responses of osteoblast-like cells to loading on titanium (Ti)-coated versus plain silicone substrates. Ti-coated substrates were made by a radio-frequency magnetron sputtering process, and characterized using Rutherford backscattering spectrometry, X-ray photoelectron spectroscopy, and contact-angle measurements. Osteoblast-like cells cultured from rat bone marrow were seeded on both types of substrates and stretched for 1 h continuously. Subsequently, cell proliferation, alkaline phosphatase activity, and calcium content were measured for up to 24 days after seeding. In addition light-, scanning electron-, and confocal laser scanning micrographs were made. The results showed that our Ti coating had a thickness of 50 nm and contained Ti/oxygen as 1:1. However, further characterization proved that the silicone material had a tendency to resurface through the coating. Osteoblast-like cells proliferated faster on the Ti-coated substrates, but differentiation was slower compared with the silicone substrates. It was concluded that that there was a definitive influence of the substrate material in mechanical stress models. Therefore, extrapolation of results obtained using silicone substrates cannot be translated directly toward the situation of metallic implant materials.

Alkaline Phosphatase↗

Metal release from plates used in jaw fracture treatment. A pilot study.

This study investigated the occurrence of corrosion associated with the use of metallic implants to stabilize jaw fractures. Three different types of plates, Co-Cr and Ni-Cr alloys and Titanium, were connected in vivo to the mandibular bone surface of monkeys (Cercopithecus aethiops). The animals were killed after 3 and 6 months. The mucous membrane and bone tissue were analysed for concentrations of Co, Cr, Ni, Mo, Al, and Ti by atomic absorption spectrophometry and a radiochemical neutron activation technique. With the exception of Ti, higher concentrations of all the above elements were found in the tissue near the implants when compared with contralateral controls. However, no signs of corrosion, macroscopic or microscopic, were observed on the surface of the implants.

Animals↗

Structure and properties of Titanium-25 Niobium-x iron alloys.

The present work studies the effect of iron on microstructure, mechanical properties and corrosion behavior of Ti-25Nb based system with emphasis on improving strength/modulus ratio. Experimental data shows that cast Ti-25Nb-3Fe has a beta phase with a entirely of dendrite morphology. The bending strength/modulus ratio is 24.6 higher than Ti-6Al-4V (17.4) by 41.4% and than c.p. Ti (9.3) by 165%. The critical anodic current density of the metal in 37 degrees C Hank's solutions is lower than approximately 100 microA/cm(2). Ti-25Nb-3Fe alloy has a great potential for use as an implant material.

Journal Article↗

Midterm results of the Salto Total Ankle Prosthesis.

The Salto Total Ankle Prosthesis is noncemented with mobile bearings and is characterized by an anatomic design and a dual Ti-HA coating. Between 1997 and 2000, 98 consecutive Salto prostheses were implanted. At last followup, two patients were deceased, one patient was lost to followup, and two prostheses were removed in two patients. Ninety-three implants in 91 patients were available with a mean followup of 35 months (range, 24-68 months). Survivorship at 68 months, with the end point implant removal, then was 98% (favorable scenario) to 94.9% (unfavorable scenario). The American Orthopaedic Foot and Ankle Society score was 32.3 points preoperatively and 83.1 points at followup. Seventy-two patients are pain-free, 54 patients walk unlimited distances, and 25 patients have limitation but walk more than 1 km. Sixty-seven patients have no limp but seven need walking aids. Fifty-eight patients can walk on tiptoes, 49 patients can walk on uneven ground, 14 patients can run, 76 patients ascend stairs normally, and 63 patients descend stairs normally. Range of motion as measured on stress radiographs improved from 15.2 degrees preoperatively to 28.3 degrees at followup. Preliminary results of the Salto prosthesis are encouraging and validate the concept of anatomic replacement.

Adult↗

Radiographic parameters as prognostic indicators for healing of class II furcation defects.

OBJECTIVE: To evaluate radiographic measurements for use as prognostic indicators for healing of class II furcation defects following regenerative therapy. MATERIAL AND METHODS: In 17 patients (eight females), 33 class II furcation defects (mandibular buccal (n=10) and lingual (n=12), and maxillary buccal (n=11)) were treated using the barrier membrane technique. Twenty-six furcations were treated using a bioabsorbable membrane, while a nonresorbable membrane was used to treat the remaining seven furcation defects. Clinical parameters and standardized radiographs were obtained before as well as 6 and 24 months after therapy. All radiographs were digitized and evaluated by an examiner blinded to the clinical data. The following distances were measured: cemento-enamel junction line (CEJ-line) to alveolar crest (AC) at the furcation site (AC-CEJ line), CEJ-line to the furcation fornix (Fx-CEJ line), width of the furcation at the level of the AC (FW) as well as the distance from Fx to a straight line between the AC mesial and distal of the tooth (Fx-AC line). RESULTS: Statistically significant (p<0.001) horizontal attachment gains could be observed 6 and 24 months after therapy (6 months: 1.49+/-0.85 mm; 24 months: 1.14+/-0.91 mm). However, a small but statistically significant (p=0.031) attachment loss of 0.35 mm was observed between the 6 and 24 months examination. Multilevel regression analyses identified baseline probing depth (p=0.0017) and 3 of the radiographic distances as prognostic factors: Fx-CEJ line (p=0.014), FW (p=0.0535), Fx-AC line (p=0.0827). CONCLUSION: The analysis of presurgical radiographs may yield information on the success of the regenerative therapy of buccal and lingual class II furcation defects. A long root trunk, a wide furcation entrance and an Fx coronal to the AC have negative influences on the success of therapy. Further, a deep probing depth at the furcation site at baseline increases the likelihood for more favourable horizontal attachment gain in furcations.

Absorbable Implants↗

[15 years experience with the Ti-6Al-7Nb alloy for joint prostheses].

The Ti-6Al-7Nb alpha-beta alloy, Protasul-100 was developed between 1978 and 1982, and proved to be highly biocompatible. In 1985 the TiAlNb material was approved for clinical use. Over the last ten years, more than 200 tons of semi-finished bar material has been processed, mainly for the production of cementless femoral stem systems and elastically deformable cup shells. For uncemented femoral components of knee prostheses made of TiAlNb, a special oxygen diffusion hardening process was developed that enables a surface hardness of up to 1200 HV and 600 HV at a depth of 20 microns, as compared with 350 HV in the case of the TiAlNb base material. This ODH-treated, polished surface is extremely scratch and wear resistant, and forms a good articulating surface with UHMW polyethylene. This surface-hardened TiAlNb, Tribosul, has been in clinical use in femoral knee components since 1990, and a multicentric clinical study involving femoral heads for hip prostheses has been ongoing since 1992. These different applications in hip and knee joint prostheses may suffice to demonstrate that the custom-made Ti-6Al-7Nb alpha-beta alloy is a real alternative to the well-known Ti-6Al-4V alloy, which has been used for decades as an implant material. Both national and international standards are available, and the alloy was already approved by the FDA in 1987.

Alloys↗

[The LSP test for determining oscillation resistance of spinal implants].

QUESTION: New spinal implants need to be tested for primary stability in vitro under standardized laboratory conditions. To ensure the reliability of the test procedures, quality assurance standards in accordance with ISO 9000 were introduced to standardize testing including experimental set ups, loading and test frequency. These standards, however, require a relatively long time to implement. METHOD: The LSP test was used to compare various surface treatments by different shot peening processes applied to spinal rods for dorsal spine implant systems. 6 rods made of two different cp-Titanium materials (Ti-2 and Ti-4) were tested. Dynamic tests were performed with the MTS 810 mono-axial servo-hydraulic test equipment. Beginning with a load of 200 N the rods were subjected to tensile and compressive loads, which were increased in steps of 100 N after every 50.000 cycles until rod failure. RESULTS: Results were available after one to two weeks. The best results (LSP 167 million) were achieved with Ti-4 rods shot peened with steel balls and glass beads. In comparison, the lowest LSP value of 81 million was found with Ti-2 rods shot peened with glass beads only. CONCLUSION: This high speed testing method has reduced the development time from two years to 6 months.

Biomechanical Phenomena↗

[Bone mineral density and biomechanical characters of the augmented alveolar ridge by distraction osteogenesis using Ti-Ni shape memory alloy distractor].

OBJECTIVE: To evaluate the quality of the alveolar ridge augmented by Ti-Ni shape memory alloy (Ti-Ni SMA) distractor. METHODS: All of the mandibular premolars and the first molars were extracted from 12 adult mongrel canines. One month later, box-shaped osteotomy was carried out in the left mandibles and Ti-Ni SMA distractors were imbedded. The right sides served as blank control. The canines were killed 3 or 6 months later and specimens were taken from corresponding area of the experiment sides and the control. Bone mineral density and biomechanical function were measured. RESULTS: Bone mineral density, ultimate compressive strength and Young's Modules of the augmented ridge were lower than the blank control three months after distraction. But the indexes increased and showed no significant difference with the control six months after distraction. CONCLUSIONS: The canines mandibular posterior alveolar ridge could be augmented by distraction osteogenesis using Ti-Ni SMA distractor, and the new bone is strong enough for implant placement.

Alveolar Ridge Augmentation↗

Monocyte viability on titanium and copper coated titanium.

The role of apoptosis/cell death in the inflammatory response at the implanted materials is unexplored. Two surfaces with different cytotoxic potential and in vivo outcomes, titanium (Ti) and copper (Cu) were incubated in vitro with human monocytes and studied using a method to discriminate apoptotic and necrotic cells (Annexin V/PI staining). Further, staurosporine, a potent inducer of apoptosis, was added to the surface adherent monocytes. Lactate dehydrogenase (a marker of cell membrane injury) and TNF-alpha and IL-10, cytokines, previously suggested to play a major role in the monocyte apoptosis, were assayed in the culture medium. The results demonstrated that Ti surfaces displayed enhanced monocyte survival and production of IL-10 and TNF-alpha. Cu adherent cells exhibited apoptotic signs as early as 1h after incubation. In contrast to Ti, after 48 h the predominance of apoptotic cells switched to apoptotic/necrotic cells on Cu surfaces. Staurosporine treatment of Ti adherent cells mediated similar type of cell death. LDH and cytokine contents were low around Cu surfaces, partly explained by interference between Cu ions and LDH and cytokines. This study suggests that material properties rapidly influence the onset of human monocyte apoptosis and progression to late apoptosis/necrosis. Early detection of apoptosis and cell death may be important for the understanding of the biological response to implanted materials.

Annexin A5↗

Mechanical wear behavior of nanocrystalline and multilayer diamond coatings on temporomandibular joint implants.

We used microwave plasma chemical vapor deposition to deposit nanocrystalline and multilayer (nanocrystalline/microcrystalline/nanocrystalline) diamond thin films on Ti-6AI-4V substrates imitating the condyle and fossa components of the temporomandibular joint. We tested the condyle/fossa pairs for wear in a mandibular movement simulator for an equivalent of two years of clinical use. Analysis of the wear surfaces by optical microscopy, scanning electron microscopy (SEM), and Raman spectroscopy showed that damage in both the films was minimal, no loss of film occurred and the wear performance was superior for the multilayer film. Comparisons with an uncoated condyle/fossa pair showed that the coated temporomandibular joint pairs had improved wear performance.

Diamond↗

The cell attachment and morphology of neonatal rat calvarial osteoblasts on the surface of Ti-6Al-4V and plasma-sprayed HA coating: effect of surface roughness and serum contents.

The biocompatibility of material plays an important role in the bone-implant interface for the prosthetic implant fixation. The biocompatibility of implants is associated with the chemical composition, surface topography, surface energy and surface roughness of biomaterials. The effects of two factors, surface roughness and serum contents, on osteoblast behavior at the surface of Ti-6Al-4V and plasma sprayed HA coating were investigated in the experiment. The osteoblasts derived from neonatal rat calvarial were cultured in Dulbecco's modified Eagle medium (DMEM) with fetal bovine serum (FBS) on the surface of polished Ti-6Al-4V (Ti-p), grit-blasted Ti-6Al-4V (Ti-b), polished HA coating (HAC-p), and as-sprayed HA coating (HAC). Under culture medium containing 4% FBS, the level of cell attachment to the polished surface is significantly higher than the rough surface of the same experimental materials during all culture periods. Increasing the contents of FBS up to 10%, the difference of osteoblast attachment is not found between Ti-p and Ti-b. Under 4% serum condition, the cell morphology attached to smooth surfaces (Ti-p and HAC-p) is spread faster and are more flattened than the one to rough surface of the same experimental materials by SEM. After 24 h culture, the corroded cracks are easily observed at the surface of polished HA coatings, and the cell morphology on HAC-p coatings are elongated and less flattened compared with Ti-p. The result is consistent with statistical difference of cell attachment between Ti-p and HAC-p under 4% serum condition.

Journal Article↗

Hydroxyapatite coatings on Ti produced by hot isostatic pressing.

Plasma spraying is a technique currently used in the production of HA-coated titanium implants. These coatings have been shown to be porous; they dissolve and have a weak bond to the substrate. The long-term interface strength has been questioned in particular. The aim of the present work was to produce HA coatings without the shortcomings of those produced by plasma spraying. Hot isostatic pressing (HIP) at 850 degrees C and 1000 bar with no holding time was applied for this purpose. Initially, the HA powder was mixed with water and air sprayed on the Ti substrate. The Ti specimens were then cold-pressed, enclosed by a protective Pt foil, and encapsulated in an evacuated glass ampulla. Subsequent to HIP, the glass and the Pt foil were removed. These coatings were denser than those produced by plasma spraying. The bonding was measured to be > 62 MPa, which is considered to be satisfactory. The structure of the coating was checked by X-ray diffraction and IR spectroscopy, and was found to correspond to that of HA. Some cracks were observed in the coating running predominantly vertical to the surface. Whether these are acceptable has to be verified by in vivo experiments.

Biocompatible Materials↗