PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Angiography, Digital Subtraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33Linked to original sources

Automatic selection of mask and arterial phase images for temporally resolved MR digital subtraction angiography.

For time-resolved background-subtracted contrast-enhanced magnetic resonance angiography, the bright and sparse arterial signal allows unique identification of contrast bolus arrival in the arteries. This article presents an automatic filtering algorithm using such arterial characterization for selecting arterial phase images and mask images to generate an optimal summary arteriogram. A paired double-blinded comparison demonstrated that this automatic algorithm is as effective as the manual process.

Adult↗

[Value of intravenous digital subtraction angiography (DSA) for the assessment of surgical blood vessel reconstruction].

Intravenous digital subtraction angiography (DSA) was obtained in 55 cases after reconstructive procedures of the carotid arteries, the pelvic and lower limb arteries. In 48 cases (87%) the studies were of technically satisfactory or good quality. On DSA 32 vascular reconstructions were normal and 16 had typical complications like occlusions, stenoses, aneurysms and insufficient run-off. -Experience indicates that the spatial resolution of DSA is adequate for clinical purposes such as determining graft patency or the presence of postoperative complications. Because DSA is less invasive than catheter angiography, postoperative evaluation of patients having undergone peripheral surgical revascularization should start with DSA.

Aged↗

Digital subtraction angiography of the renal arteries. Prospective comparison with conventional arteriography.

Intravenous digital subtraction angiography (IV-DSA) of the aorta and renal arteries was compared with conventional arteriography of 40 patients with 92 renal arteries. Inadequate visualization of the vessel occurred in six renal arteries (6.5%). In arteries adequately imaged, for the evaluation of renal artery stenosis, the sensitivity of IV-DSA was 87.5% (28/32), the specificity 100% (54/54), and the accuracy 95.3% (82/86). Overall, accurate IV-DSA was obtained in 89.1% (82/92) of renal arteries and 85% (34/40) of the patients. IV-DSA is an accurate screening procedure for renal artery stenosis.

Angiography↗

Effectiveness of antiscatter grids in digital subtraction angiography.

An analysis of the potential value of antiscatter grids for digital subtraction angiography (DSA) is presented. Using the Rose criterion for signal detection, and assuming quantum limited statistical noise, it is shown that grid selectivity and primary transmission are the two most important parameters of grid performance for DSA. In comparison with conventional grids commonly in current use in radiology departments, a grid having a higher level of primary transmission, (approximately 90%) and a moderate level of selectivity (approximately 6) could provide comparable imaging signal-to-noise ratios, but with 20% to 45% smaller patient dose. Implications of these results are discussed.

Angiography↗

Comparison of iohexol and ioxaglate for intravenous digital subtraction angiography of the neck and head.

Two hundred patients undergoing intravenous digital subtraction angiography of the cerebral circulation were examined on a random basis with either iohexol 350 mg I/mL or ioxaglate 320 mg I/mL. The two low osmotic media provided equally satisfactory image quality and diagnostic possibilities. No significant differences were found in incidence and severity of adverse reactions.

Carotid Arteries↗

Complications of outpatient transbrachial intraarterial digital subtraction angiography. Work in progress.

To assess the safety of nonselective intraarterial digital subtraction angiography (DSA) performed from a brachial artery approach, the complications of 660 consecutive examinations, most of which (greater than 95%) were performed on outpatients, were studied. Contrast material injections into the aorta were made through a 4-F multiple side-hole pigtail catheter inserted percutaneously from the brachial artery. Two brachial artery complications severe enough to require surgery occurred (one hematoma and one arterial laceration/thrombosis), for a rate of 0.3%. No cerebrovascular complications were encountered. Delayed and minor complications were retrospectively studied in 137 patients; they included local arm pain in 24 patients (17.5%), transient paresthesia in ten (7.3%), ecchymosis in 69 (50.4%), and hematoma in 13 (9.5%). The transbrachial approach to nonselective intraarterial DSA is a safe alternative to the femoral artery approach.

Adolescent↗

Digital subtraction angiography: overview of technical principles.

The rapid development of equipment for digital subtraction angiography (DSA) has created a new diagnostic imaging method, the limits of which have not been scientifically determined. Yet through aggressive marketing, the technique is already beginning to permeate radiologic practice. The radiologist requires technical understanding of the instrumentation for informed judgment on clinical applications. DSA depends on the mating of high-resolution image-intensifier and television technology with computerized information manipulation and storage. In this overview, the individual components of the system are analyzed, from the generator to the image intensifier to the television system to the associated computer. By examining the role of each component, the current limitations and the areas of possible future development of DSA can be understood. This provides a basis for dealing with current technology and for evaluating the rapid technological changes that will occur over the next few years.

Angiography↗

Intravenous digital subtraction angiography in the assessment of patients for carotid endarterectomy.

Preoperative intravenous digital subtraction angiography (IV DSA) was compared with the operative findings in 54 patients who underwent a total of 57 carotid endarterectomies, to evaluate the accuracy of preoperative IV DSA in predicting the lesion found at surgery. Four studies early in the series were technically unsatisfactory, leaving 50 patients with 53 procedures for evaluation. Severe carotid artery stenosis was accurately predicted in all cases. Deep ulceration in the absence of severe carotid stenosis was reliably shown by IV DSA, although it was not reliably demonstrated by either IV DSA or carotid angiography if severe stenosis was also present. As severe carotid stenosis or deep ulceration are the major radiological indications for carotid endarterectomy, the authors have found that technically satisfactory IV DSA is an adequate preoperative imaging technique.

Arterial Occlusive Diseases↗

Somatic and genetic radiation exposure of the patient in digital subtraction angiography (DSA)

The somatic and genetic radiation exposure of patients undergoing Digital Subtraction Angiography (DSA) and traditional Film Arteriography (FA) of cranial, cervical, thoracic and abdominal vascular territories are compared. The radiation doses absorbed within the critical organs--red bone marrow, lung, thyroid gland and female breast--and in the gonads were measured using an anthropomorphic Alderson phantom. A Somatic Dose Index was calculated in order to estimate the somatic radiation risk. The somatic radiation exposure depends upon the location of the critical organs with respect to the entrance site of the x-ray beam, and can be reduced by an appropriate choice of the angiographic projection. Under this condition, the radiation exposure of the patient during DSA can be lower than during FA. For renal DSA an a.p. projection, the use of an abdominal compression device and careful caudal shielding of the field are advocated.

Cerebrovascular Disorders↗

Digital subtraction angiography of the carotid bifurcation.

This report described the results of digital subtraction angiography (DSA) in the diagnosis of arteriosclerotic disease of the extracranial arteries, especially the distal part of the common- and proximal part of the internal carotid arteries compared to the catheter angiography. 50 patients underwent DSA and conventional angiography. In 85% of the patients, the quality of the DSA examination was good. For the internal carotid arteries the standard sensitivity was 91% and the standard specificity 93%. In all patients both vertebral arteries were visualized on DSA. All patients underwent the non-invasive tests (OPG, Doppler, Duplex). These tests and the DSA together cannot always replace the catheter-angiography in case of carotid pathology. We started an investigation to assess in which cases the catheter-angiography can be replaced by DSA to arrive at the same diagnosis. The preliminary results indicate that replacement of the conventional angiography by DSA is possible in 80% of this patients group.

Adult↗

Isolated intrapetrous carotid canal atraumatic internal carotid artery dissection: MRI and digital subtraction angiography findings.

A case of spontaneous internal carotid artery (ICA) dissection confined to the intrapetrous carotid canal that was confirmed by angiography and magnetic resonance imaging is presented. Isolated dissection involving the intrapetrous ICA is rare; however, whenever arterial dissection is a consideration, specific review of imaging in this region is warranted.

Adult↗

Color-coded image-directed Doppler sonography compared with digital subtraction angiography in the follow-up of percutaneous vascular endoprostheses.

Color-coded image-directed Doppler sonography (CCIDS) was used in the follow-up of self-expandable vascular endoprostheses and was compared with the results of digital subtraction angiography and Doppler pressure indices. The stents were implanted in iliac and femoral arteries or hemodialysis fistulae of 26 patients. The aim of the study was to evaluate the potential of the new imaging method to identify local flow patterns inside of vascular endoprostheses. The stents were identified by sonography in all cases; laminar flow was represented in CCIDS by homogeneous Doppler signals. In case of a distinctly reduced lumen, intravenous digital subtraction angiography (DSA) and CCIDS were both able to identify the stenotic process; however, CCIDS was superior in the demonstration of minute flow irregularities. No different flow patterns were detected in comparing recent with older vascular implants.

Angiography, Digital Subtraction↗

Effect of radiographic techniques (kVp and mAs) on image quality and patient doses in digital subtraction angiography.

We investigated how varying the x-ray tube voltage and image receptor input exposure affected image quality and patient radiation doses in interventional neuroradiologic imaging. Digital subtraction angiography (DSA) images were obtained of a phantom with 1 mm diameter vessels containing iodine at concentrations between 4.5 and 50 mg/cc. The detection threshold concentration of iodine was determined by inspecting DSA images obtained at a range of x-ray tube voltages and input exposure levels. Surface doses were obtained from measured x-ray tube output data, and corresponding values of energy imparted were determined using the exposure-area product incident on the phantom. In one series of experiments, the air kerma at the image intensifier (X) was varied between 0.44 microGy per frame and 8.8 microGy per frame at a constant x-ray tube voltage of 70 kVp. In a second series of experiments, the tube voltage was varied between 50 and 100 kVp, and the mAs adjusted to maintain a constant exposure level at the input of the image intensifier. At a constant x-ray tube voltage, the surface dose and energy imparted were directly proportional to the input exposure per frame used to acquire the DSA images. On our DSA system operated below 2.2 microGy per frame, the threshold iodine concentration was found to be proportional to X(-0.57), which is in reasonable agreement with the theoretical prediction for a quantum noise limited imaging system. Above 2.2 microGy per frame, however, the threshold iodine concentration was proportional to X(-0.26), indicating that increasing the input exposure above this value will only achieve modest improvements in image quality. At a constant image intensifier input exposure level, increasing the x-ray tube voltage from 50 kVp to 100 kVp reduced the surface dose by a factor of 6.1, and the energy imparted by a factor of 3.5. The detection threshold iodine concentration was found to be proportional to kVp(n), where n was 2.1 at 1.1 microGy per frame, and 1.6 at 3.9 microGy per frame. For clinical situations that can be modeled by a uniform phantom, reducing the x-ray tube voltage rather than increasing the exposure level would best achieve improvements on our DSA imaging system performance.

Angiography, Digital Subtraction↗

Carbon dioxide digital subtraction angiography in oncological-interventional radiology.

AIMS AND BACKGROUND: The aim of this work is to demonstrate the usefulness of carbon dioxide, used as contrast agent, in special indications in vascular interventional oncological procedures. METHODS: We studied 40 patients with digital subtraction angiography enhanced with CO2 as a contrast agent. At the same time we utilized also, in all cases, jodinated contrast agent to evaluate the different opacification gradient, the different viscosity range and the different perfusion. RESULTS: The low viscosity of CO2 allows demonstration of the presence of even minimal blood losses in gastrointestinal tumors and enhances arteriovenous shunts in hepatocellular carcinoma. Carbon dioxide can also be employed to assess the patency of small-sized catheters for chemotherapy infusion which do not allow easy injection of the traditional iodinated contrast agents characterized by high viscosity. CONCLUSION: Carboangiographic study combined to digital subtraction angiography can clear some diagnostic problems and is further method to assess the outcome of angiographic interventional procedures in oncology.

Adult↗

Intra-arterial digital subtraction angiography of the pulmonary arteries using a flow-directed balloon catheter in the diagnosis of pulmonary embolism.

Selective intra-arterial digital subtraction angiography (IA-DSA) of the pulmonary vessels was performed in 70 patients suspected of acute pulmonary embolism. A flow-directed Swan-Ganz pulmonary angiography catheter was used. The spatial resolution of the equipment used was 3.3 lp/mm for DSA and 6.0 lp/mm for conventional pulmonary angiography (CPA). Image quality of the angiograms was assessed by determining the highest visible branching division of the main pulmonary artery. The mean visible branching division for IA-DSA was 4.71 (range 3-7). In 10 patients where IA-DSA and CPA were performed during the same procedure there was no difference in visualization of peripheral arteries (mean 4.70 visible order for both modalities). IA-DSA makes the procedure rapid, saves on films and contrast material and allows good visualization of areas where exposure is difficult. The spatial resolution of state-of-the-art equipment permits sufficient definition of subsegmental vessels. The use of the flow-directed balloon catheter makes the examination easy to perform and minimizes the risk of catheter induced cardiac arrhythmias.

Adult↗

Bilateral internal carotid aneurysms presenting as a nonpulsatile parapharyngeal mass: complementary diagnosis by CT, MR imaging, and digital subtraction angiography.

SUMMARY: We report fusiform aneurysms in both internal carotid arteries in a 74-year-old man who presented with a nonpulsatile retropharyngeal mass. Both helical CT and MR imaging disclosed the nature of the lesions. Arteriography, required for therapeutic decisions, confirmed the diagnosis. Because of the rarity of this condition and the potential for misdiagnosis, we describe the findings on complementary radiologic examinations.

Aged↗

[Digital subtraction angiography (DSA) in the diagnosis of orbital diseases].

DSA was used in confirming the diagnoses of 3 cases of arteriovenous aneurysm, 3 cases of arteriovenous communication in the orbit or the cavernous sinus, and 1 case each of internal carotid aneurysm and granular myoblastoma. The technique provided basis for the selection of surgical approaches. One case each of orbital apex inflammation, ophthalmic Graves disease and orbital varix displayed normal findings with DSA.

Adolescent↗