PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Automation, Laboratory”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33Linked to original sources

Relationship of depression and diabetes self-care, medication adherence, and preventive care.

OBJECTIVE: We assessed whether diabetes self-care, medication adherence, and use of preventive services were associated with depressive illness. RESEARCH DESIGN AND METHODS: In a large health maintenance organization, 4,463 patients with diabetes completed a questionnaire assessing self-care, diabetes monitoring, and depression. Automated diagnostic, laboratory, and pharmacy data were used to assess glycemic control, medication adherence, and preventive services. RESULTS: This predominantly type 2 diabetic population had a mean HbA(1c) level of 7.8 +/- 1.6%. Three-quarters of the patients received hypoglycemic agents (oral or insulin) and reported at least weekly self-monitoring of glucose and foot checks. The mean number of HbA(1c) tests was 2.2 +/- 1.3 per year and was only slightly higher among patients with poorly controlled diabetes. Almost one-half (48.9%) had a BMI >30 kg/m(2), and 47.8% of patients exercised once a week or less. Pharmacy refill data showed a 19.5% nonadherence rate to oral hypoglycemic medicines (mean 67.4 +/- 74.1 days) in the prior year. Major depression was associated with less physical activity, unhealthy diet, and lower adherence to oral hypoglycemic, antihypertensive, and lipid-lowering medications. In contrast, preventive care of diabetes, including home-glucose tests, foot checks, screening for microalbuminuria, and retinopathy was similar among depressed and nondepressed patients. CONCLUSIONS: In a primary care population, diabetes self-care was suboptimal across a continuum from home-based activities, such as healthy eating, exercise, and medication adherence, to use of preventive care. Major depression was mainly associated with patient-initiated behaviors that are difficult to maintain (e.g., exercise, diet, medication adherence) but not with preventive services for diabetes.

Body Mass Index↗

The association of comorbid depression with mortality in patients with type 2 diabetes.

OBJECTIVE: We assessed whether patients with comorbid minor and major depression and type 2 diabetes had a higher mortality rate over a 3-year period compared with patients with diabetes alone. RESEARCH DESIGN AND METHODS: In a large health maintenance organization (HMO), 4,154 patients with type 2 diabetes were surveyed and followed for up to 3 years. Patients initially filled out a written questionnaire, and HMO-automated diagnostic, laboratory, and pharmacy data and Washington State mortality data were collected to assess diabetes complications and deaths. Cox proportional hazards regression models were used to calculate adjusted hazard ratios of death for each group compared with the reference group. RESULTS: There were 275 (8.3%) deaths in 3,303 patients without depression compared with 48 (13.6%) deaths in 354 patients with minor depression and 59 (11.9%) deaths among 497 patients with major depression. A proportional hazards model with adjustment for age, sex, race/ethnicity, and educational attainment found that compared with the nondepressed group, minor depression was associated with a 1.67-fold increase in mortality (P = 0.003), and major depression was associated with a 2.30-fold increase (P < 0.0001). In a second model that controlled for multiple potential mediators, both minor and major depression remained significant predictors of mortality. CONCLUSIONS: Among patients with diabetes, both minor and major depression are strongly associated with increased mortality. Further research will be necessary to disentangle causal relationships among depression, behavioral risk factors (adherence to medical regimens), diabetes complications, and mortality.

Black or African American↗

Warfarin use among ambulatory patients with nonvalvular atrial fibrillation: the anticoagulation and risk factors in atrial fibrillation (ATRIA) study.

BACKGROUND: Warfarin dramatically reduces the risk for ischemic stroke in nonvalvular atrial fibrillation, but its use among ambulatory patients with atrial fibrillation has not been widely studied. OBJECTIVE: To assess the rates and predictors of warfarin use in ambulatory patients with nonvalvular atrial fibrillation. DESIGN: Cross-sectional study. SETTING: Large health maintenance organization. PATIENTS: 13428 patients with a confirmed ambulatory diagnosis of nonvalvular atrial fibrillation and known warfarin status between 1 July 1996 and 31 December 1997. MEASUREMENTS: Data from automated pharmacy, laboratory, and clinical-administrative databases were used to determine the prevalence and determinants of warfarin use in the 3 months before or after the identified diagnosis of atrial fibrillation. RESULTS: Of 11082 patients with nonvalvular atrial fibrillation and no known contraindications, 55% received warfarin. Warfarin use was substantially lower in patients who were younger than 55 years of age (44.3%) and those who were 85 years of age or older (35.4%). Only 59.3% of patients with one or more risk factors for stroke and no contraindications were receiving warfarin. Among a subset of "ideal" candidates to receive warfarin (persons 65 to 74 years of age who had no contraindications and had previous stroke, hypertension, or both), 62.1% had evidence of warfarin use. Among our entire cohort, the strongest predictors of receiving warfarin were previous stroke (adjusted odds ratio, 2.55 [95% CI, 2.23 to 2.92]), heart failure (odds ratio, 1.63 [CI, 1.51 to 1.77]), previous intracranial hemorrhage (odds ratio, 0.33 [CI, 0.21 to 0.52]), age 85 years or older (odds ratio, 0.35 [CI, 0.31 to 0.40]), and previous gastrointestinal hemorrhage (odds ratio, 0.47 [CI, 0.40 to 0.57]). CONCLUSIONS: In a large, contemporary cohort of ambulatory patients with atrial fibrillation who received care within a health maintenance organization, warfarin use was considerably higher than in other reported studies. Although the reasons why physicians did not prescribe warfarin could not be elucidated, many apparently eligible patients with atrial fibrillation and at least one additional risk factor for stroke, especially hypertension, did not receive anticoagulation. Interventions are needed to increase the use of warfarin for stroke prevention among appropriate candidates.

Aged↗

Housing mice in a caging system with automatic flushing.

Male Har:(ICR)BR mice were housed 8 wk in wire bottom cages over paper, in wire bottom cages over an automatic cascade flushing system, or in solid-bottom plastic cages with bedding material. There were no substantial differences in general health or weight gain. Pentobarbital LD50 values were lower for the mice housed in wire bottom cages than for the mice in solid bottom cages with bedding. This difference was probably related to gastrointestinal content. It appears that the automatic cascade flushing system is suitable for housing mice for periods up to 8 wk.

Animals↗

[Thyroxine (T4) and tri-iodothyronine (T3) determinations: techniques and value in the assessment of thyroid function].

Hormonal production of the thyroid gland is constituted of thyroxine or T4 (80%) and triiodothyronine or T3 (20%). In the circulation, whole T4 originates from thyroid secretion but most of T3 (80%) is produced extrathyroidally from T4 deiodination. Conversion of T4 to T3 may be influenced by various conditions and circulating T3 is a less reliable reflection of thyroid hormone production than T4. In serum most of T4 and T3 is bound to binding proteins and only 0.02% of T4 and 0.3% of T3 is free. Because of their higher diagnostic performance, free T4 (FT4) and free T3 (FT3) measurements have superseded total (free + bound) hormone determination. Total hormone measurements remain useful for research studies or in case of severe hyperthyroidism. Equilibrium dialysis/RIA is considered as the reference method for free hormone measurements. Routine clinical laboratories use automated direct two-step or one-step immunoassays with a high molecular weight ligand or labelled antibody. Free hormone measurement remains technically demanding, especially in sera from severe non-thyroid ill patients with low serum thyroxine binding capacity. Interference from anti-thyroid hormone antibodies and familial dysalbuminemic hyperthyroxinemia depends on the assay method, but is now less marked and less frequently detected. To be able to correctly interpret the results of an assay, it is necessary to assess its performance in biologically and clinically well-characterised serum samples. FT4, and FT3 measurements, if FT4 is normal and hyperthyroidism suspected, are used to confirm and assess the level of hypo and hyperthyroidism (overt or subclinical). When the thyroidal status is unstable (first months of a thyroid treatment, altered L-T4 dose, subacute thyroiditis) or when the hypothalamic-pituitary function is disturbed (central hypothyroidism), TSH determination is diagnostically misleading and only free hormone measurements are reliable for thyroid function assessment.

Humans↗

Progress in improving state and local disease surveillance--United States, 2000-2005.

In September 2000, states began receiving federal funding to plan and implement integrated electronic systems for disease surveillance. CDC and state and local health departments had recognized the importance of such systems and of uniform standards to improve the usefulness of public health surveillance and the timeliness of response to outbreaks of disease. Previously, state health departments received most case-report forms by mail and then entered the data into computer systems, sometimes weeks after the cases of notifiable disease had occurred, including cases that warranted immediate public health investigation or intervention. In addition, depending on the disease, only 10%-85% of cases were reported, and more than 100 different systems were used to transmit these reports from the states to CDC (CDC, unpublished data, 2005). This report summarizes progress since the initial funding in 2000 in improving state and local disease surveillance through secure, Internet-based data entry and automated electronic laboratory results (ELR) reporting. Both are components of the National Electronic Disease Surveillance System (NEDSS), the surveillance and monitoring component of the broader Public Health Information Network (PHIN) initiative. Local, state, and national public health officials should continue to improve the timeliness and completeness of disease surveillance.

Humans↗

[Confirmation of pipetting performances for fully-open automatic biochemistry analyzers].

This paper introduces a kind of evaluation method in pipetting performance on new fully automated biochemistry analyzers by experiments. The performance of sample pipetting volume is confirmed by dye dilution method, the performance of reagent pipetting volume and dummy volume is done by weighing method. Meanwhile, researches and comparative researches on dummy volumes in different conditions have been made, providing valuable reference for clinical applications of automatic biochemistry analyzers.

Automation, Laboratory↗

[A method of measuring the triboluminescence of blood using the TRA-2 rapid analyzer].

The procedure of triboluminescent analysis of blood lipid peroxidation processes using TRA-2 express analyzer is described. 0.02 ml of the blood is sufficient for analysis that takes 40 seconds; all the measurements are automated, no laboratory assistants participate here; no special chemical reagents are necessary. Results of laboratory clinical trials evidence good prospects of employing this method for the differential diagnosis between oncologic and inflammatory diseases.

Adult↗

The dependence of the International Sensitivity Index on the coagulometer used to perform the prothrombin time.

This study was designed to detect any effect that different types of coagulation instrument may have on the International Sensitivity Index (ISI) of a thromboplastin. Manufacturers of commercial thromboplastins now calibrate their reagents against the World Health Organization international reference preparation to assign them an ISI. This enables the prothrombin time (PT) estimated with that reagent to be expressed as an International Normalised Ratio (INR). One batch of Thromborel S was calibrated against the Australasian Reference Thromboplastin (ART). The Thromborel S was used on three photo-optical instruments, the Automated Coagulation Laboratory (ACL) (Instrumentation Laboratory), the Cobas Fibro (Roche), and the Coag-a-Pet (General Diagnostics). PTs using ART were performed manually using the reference method. The ISIs calibrated in our laboratory when the ACL and Cobas Fibro were used were not significantly different at the 95% level, being 1.102 +/- 0.018 and 1.134 +/- 0.022 respectively. The ISI with the Coag-a-Pet of 1.223 +/- 0.023 was significantly different to that of the ACL and the Cobas Fibro at the 95% level. The flowcharts for a computer program to perform the necessary calculations are provided. The program allows for the entry and editing of data from the calibration procedure, and provides a mean normal PT and normal range, the ISI and 95% confidence limits of the calibration, and a chart for the conversion of the test PTs to INRs. The authors have made available an IBM compatible program for the calibration of thromboplastins.

Blood Coagulation Tests↗

Feasibility of centralized measurements of glycated hemoglobin in the Diabetes Control and Complications Trial: a multicenter study. The DCCT Research Group.

A method for measuring glycated hemoglobin (Hb A1c) and an accompanying method of specimen transport to a central laboratory were developed for the multicenter Diabetes Control and Complications Trial (DCCT). In the DCCT, results for Hb A1c are used to assess chronic glycemic control for data collection and patient management. During the feasibility phase of the trial, central (CHL) and backup laboratories using automated, "high-performance" ion-exchange liquid-chromatographic methods were established. Whole-blood samples were stored (4 degrees C) at each of the 21 clinical centers for up to 72 h before air-express shipment to the CHL. Quality-control procedures included daily analyses of three calibration specimens. A pooled hemolysate was assayed frequently over time as a long-term quality control (LTQC). After 18 months, within- and between-run CVs were less than 6%. Mean values for split duplicate samples assayed in a masked fashion at the CHL were nearly identical. LTQC results indicated no significant assay drift over time. More than 6000 samples were assayed (mean interval between obtaining the blood sample and completing the assay: less than six days). Hb A1c evidently can be precisely and reliably measured in the context of a long-term, multicenter trial such as the DCCT.

Adult↗

[Automation in hematology (author's transl)].

A special meeting of the French Hematological Society, held on October 4 and 5, 1976, was devoted to automation in hematology. Six topics were discussed: description of the apparatus and discussion of the results of hemostasis (ELECTRA 600 D, COAGULOMETER, COAG A PET, THROMBOLAB and AUTO FI DADE); automation in blood group determination (Technicon auto-analyzer, Groupamatic MG 50, and picture analysis by the QTM 720); automatic differential white cell counts with presentation of and results obtained with the HEMA-LOG D, CORNING LARC, GEOMETRIC DATA, HEMATRAK and PERKIN ELMER DIFF 3 systems; the value of cell volume analysis in the study of red blood cells, platelets, normal lymphocytes, lymphocytes in chronic lymphocytic leukemia and blast cells; contribution of new picture analysis apparatus in the study of fibrosis and bone marrow insufficiency; the place of automation in laboratory management.

Autoanalysis↗