[A new process for the determination of chlorides in body fluids].
Explore the source record for details and available documents.
SEARCH · PubMed Health
Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
BACKGROUND: Hypovolaemia stimulates the sympathoadrenal and renin systems and water retention. It has been proposed that in congestive heart failure reduction of cardiac output and any associated decrease in blood pressure cause underfilling of the arterial compartment, which promotes and perpetuates neurohumoral activation and the retention of fluid. This study examined whether an intravascular volume deficit accounts for patterns that largely exceed the limits of a homoeostatic response, which are sometimes seen in advanced congestive heart failure. METHODS AND RESULTS: In 22 patients with congestive heart failure and water retention the body fluid mass was reduced by ultrafiltration and the neurohumoral reaction was monitored. A Diafilter, which was part of an external venous circuit was regulated to produce 500 ml/hour of ultrafiltrate (mean (SD) 3122 (1199) ml) until right atrial pressure was reduced to 50% of baseline. Haemodynamic variables, plasma renin activity, noradrenaline, and aldosterone were measured before and within 48 hours of ultrafiltration. After ultrafiltration, which produced a 20% reduction of plasma volume and a moderate decrease in cardiac output and blood pressure (consistent with a diminished degree of filling of the arterial compartment), there was an obvious decrease in noradrenaline, plasma renin activity, and aldosterone. In the next 48 hours plasma volume, cardiac output, and blood pressure recovered; the neurohumoral axis was depressed; and there was a striking enhancement of water and sodium excretion with resolution of the peripheral oedema and organ congestion. The neurohumoral changes and haemodynamic changes were not related. There were significant correlations between the neurohumoral changes and increase in urinary output and sodium excretion. CONCLUSIONS: In advanced congestive heart failure arterial underfilling was not the main mechanism for activating the neurohumoral axis and retaining fluid. Because a decrease in circulating hormones was associated with reabsorption of extravascular fluid it is likely that hypoperfusion and/or congestion of organs, such as the kidney and lung, reduce the clearance of circulating noradrenaline and help to keep plasma concentrations of renin and aldosterone raised. A positive feedback loop between fluid retention and plasma hormone concentrations may be responsible for progression of congestive heart failure.
Leukemia inhibitory factor (LIF) has many biological actions which parallel those of IL-1, IL-6 and tumor necrosis factor-alpha, but its role in the pathogenesis of human disease is unknown. A specific radioreceptor competition assay capable of detecting LIF at concentrations above 1 ng/ml (45 pM) was developed. To identify disease states in which LIF might be involved, a cross-sectional survey of serum and body fluids from approximately 1,500 subjects with a variety of diseases was performed using the LIF radioreceptor competition assay. Serum LIF concentrations were transiently elevated (2-200 ng/ml) in six subjects with meningococcal or Gram-negative septic shock, and in a subject with idiopathic fulminant hepatic failure. Moderately elevated LIF concentrations (> 10 ng/ml) were detected in cerebrospinal fluid from subjects with bacterial meningitis, in effusions associated with pneumonia and peritonitis, and in amniotic fluid from a woman with chorioamnionitis. Low LIF concentrations (1-10 ng/ml) were present in synovial fluid from subjects with inflammatory arthritis, amniotic fluid from women in labor, and some reactive, chronic inflammatory and malignant effusions and cyst fluids, but rarely in transudates. These initial findings suggest that LIF might be involved in the pathogenesis of inflammation and septic shock.
Bulk metallic glasses (BMGs) of Zr(65 - x)Nb(x)- Cu(17.5)Ni(10)Al(7.5) with Nb = 0, 2, and 5 at % were prepared by copper mold casting. Compression tests reveal that the two BMGs containing Nb exhibited superior strength and plasticity to the base alloy. The corrosion behavior of the alloys obtained was investigated in artificial body fluid by electrochemical measurements. It was found that the addition of Nb significantly enhanced the corrosion resistance of the Zr-based BMG, as indicated by a remarkable increase in corrosion potential and pitting potential. XPS analysis revealed that the passive film formed after anodic polarization was enriched in aluminum oxide and depleted in phosphate ions for the BMGs containing Nb, which accounts for the improvement of corrosion resistance. On the other hand, metal-ion release of different BMGs were determined in PPb (ng/mL) level with inductively coupled plasma mass spectrometry (ICP-MS) after being immersed in artificial body fluid at 37 degrees C for 20 days. It was found that the addition of Nb considerably reduced the ion release of all kinds of metals of the base system. This is probably attributed to the promoting effect of Nb on a rapid formation of highly protective film.
Many of the major alterations in plasma proteins characteristic of the hepatic acute phase response are regulated by IFN-beta 2/IL-6. Using a specific bioassay for IFN-beta 2/IL-6, which relies on the induction of the hepatic acute phase plasma protein alpha 1-antichymotrypsin in the human hepatoma cell line Hep3B clone 2 and its inhibition by anti-rIFN-beta 2/IL-6 antiserum, we have detected high levels of IFN-beta 2/IL-6 in the body fluids of patients with acute bacterial infections. Cerebrospinal fluid from four patients with acute bacterial meningitis (Streptococcus pneumoniae, Staphylococcus aureus, two cases of Listeria monocytogenes) all had high levels of IFN-beta 2/IL-6 (up to 500 ng/ml). Two of these patients with concomitant bacteremia had lower concentrations of IFN-beta 2/IL-6 in the serum (5 to 70 ng/ml). Three additional patients with Escherichia coli, Pseudomonas aeruginosa, and Neisseria meningitidis bacteremia had high levels of serum IFN-beta 2/IL-6, as did the ankle fluid of a patient with Streptococcus canis arthritis. Normal cerebrospinal fluid and serum had little detectable IFN-beta 2/IL-6. A combination of immunoaffinity chromatography and immunoblotting procedures were used to characterize the IFN-beta 2/IL-6 species present in a representative sampling of serum and cerebrospinal fluids. Multiple immunoreactive species of IFN-beta 2/IL-6 in the size range 23 to 30 kDa as well as immunoreactive complexes in the range 60 to 70 kDa were detected in human body fluids. This is the first demonstration that previous descriptions of heterogeneity in human IFN-beta 2/IL-6 species produced in cell culture correspond to observations in the infected host.
An immunoaffinity capillary electrophoresis (ICE) system for rapidly quantifying recombinant cytokines in human body fluids has been developed. Cytokines within biological fluids were labeled with a red light emitting fluorochrome and injected into the capillary. Selected cytokines were captured by immobilized antibodies on the internal surface of the capillary, and held while unbound materials were purged. The cytokines were then eluted electrophoretically in acidic buffer. Individual cytokine peaks were detected by on-line laser-induced fluorescence detection coupled to a computerized fiber-optic spectrometer, and analyzed by integration of the eluted peaks. The comparison of the results of ICE to routine assays used for these cytokines demonstrates that ICE provides a fast and accurate procedure for defining these cytokines in complex biological samples. Immunoaffinity separations can be used for any material to which a specific antibody can be raised, making this procedure applicable to a wide range of molecules of biomedical interest.
In this study, breakdown potentials were measured for unpolished and mechanically polished nitinol wires in simulated body fluids. These wires are similar to those used in the manufacture of stents. Considerable scatter was observed in the results indicating a variable surface state. After appropriate heat treatments, the measured breakdown values were lower but more reproducible for the mechanically polished samples. Significantly higher breakdown potentials were observed for cross-section wire samples. Some wires were tested in human blood and the breakdown values were higher than in Ringer and 0.9% NaCl solutions. Energy dispersive X-ray analysis of the surface layers indicated that oxide thickening occurred after heat treatments. Dynamic secondary ion mass spectroscopy also revealed thickened surface oxides on the wires. The oxide was predominantly made up of TiO(2) with a very thin layer of NiO at the outer surface. Galvanic corrosion tests were performed on nitinol wires coupled with gold, elgiloy/phynox, and stainless steel. Nitinol was found to be anodic in all cases yet the currents measured were small. In tests in which nitinol-gold couples were immersed in 0.9% NaCl for periods up to 12 months, only very small amounts of nickel (in the part per billion range) were released into solution and scanning electron microscopy examination revealed no corrosion.
Cartilage oligomeric matrix protein (COMP) is a high-molecular-weight glycoprotein found at a high concentration in articular cartilage. Recent studies have shown that the joint fluid and serum levels of antigenic COMP, measured by an enzyme-linked immunosorbent assay (ELISA) which uses a polyclonal antiserum raised against bovine COMP, provide important information about metabolic changes occurring in the cartilage matrix in joint disease. In this report, we describe the specificity of three monoclonal antibodies (mAbs) to human COMP and their usefulness in quantifying antigenic COMP fragments in body fluids. Two of the mAbs (16-F12 and 18-G3) recognized both oligomeric and monomeric forms of COMP, but the third (17-C10) reacted positively only with the former. Immunoblots of human COMP, predigested with trypsin for up to 6 h, showed that the three mAbs are directed against different epitopes identified on small tryptic fragments of 30 kDa (16-F12), 25 kDa (17-C10), and 40 kDa as well as 30 kDa (18-G3), respectively. The antibodies also recognized a different pattern of fragments in human pathological synovial fluids. This was particularly striking in the case of the medium size fragments (16-F12: 90 and 110 kDa; 17-C10: 70 and 90 kDa; 18-G3: up to five bands from 70 to 130 kDa). Competitive indirect inhibition ELISAs developed with mAbs 16-F12 and 17-C10 revealed further differences in the specificities of these antibodies. Thus, while mAb 16-F12 can be used only to quantify antigenic COMP in human synovial fluid and serum, mAb 17-C10 is useful in addition when analyzing canine and horse synovial fluid as well as canine serum. The results of analyses of synovial fluid samples from patients with osteoarthritis and rheumatoid arthritis provided preliminary evidence in support of the contention that measurement of the different COMP epitopes recognized by these mAbs in body fluids could prove useful in the clinical assessment of patients with joint disease.
Different assays are employed to monitor the concentration of immunosuppressive drugs in biological fluids. None of these methods gives direct and precise information on the actual level of immunosuppression in the patient. Here we describe the use of an interleukin-2 (IL-2) reporter-gene assay (IL-2 RGA) to monitor the concentrations of immunosuppressants in body fluids. This assay is based on a chimeric gene construct in which the human IL-2 promoter drives the expression of a reporter gene. Upon mitogenic stimulation the reporter gene is expressed and can be easily quantified. The assay is very sensitive and selective for immunosuppressive compounds inhibiting IL-2 gene expression such as cyclosporine (CsA) and FK506, their active metabolites and derivatives, but not for others such as rapamycin. High reproducibility, fast performance time, and high capacity are additional characteristics of the assay. The assay was developed to monitor immunosuppressive drug levels in human volunteers or in animals receiving CsA analogues as the only immunosuppressive drugs. This assay is sensitive to CsA or ascomycin/FK506 analogues and metabolites, for which there are presently no specific monoclonal antibodies available. The IL-2 reporter-gene assay may be more suitable than other in vitro systems such as MLR or mitogen stimulated PBMC which were previously used to study the immunosuppressive activity of drugs in body fluids.
Chronic hypoxemia is associated with a decreased growth rate and a decreased rate of cell division. In lambs with experimental cyanotic heart disease, the gain in body mass was decreased. In this study, we determined to what extent the lower body mass in these lambs was related to alterations in body fluid compartment volumes, specifically whether intracellular volume was decreased. Therefore, fluid compartment volumes were studied in nine lambs, after 3 to 4 wk of experimental cyanotic heart disease, and in 13 control lambs. Hypoxemic lambs had a lower arterial oxygen saturation (65 +/- 11 versus 91 +/- 2%, p < 0.001) and a higher Hb concentration (142 +/- 16 versus 101 +/- 8 g.L-1, p < 0.001). The lower body mass in hypoxemic lambs (10.5 +/- 2.3 versus 13.0 +/- 2.8 kg) could be mainly accounted for by a decrease in intracellular water volume (4.7 +/- 1.3 versus 6.6 +/- 1.5 L, p < 0.01). Total body water (753 +/- 27 versus 780 +/- 40 mL.kg-1) and extracellular water volume (307 +/- 25 versus 277 +/- 15 mL.kg-1) in hypoxemic lambs were not significantly different from those in control lambs, but intracellular water volume was decreased (445 +/- 27 versus 501 +/- 35 mL.kg-1, p < 0.01). The ratio of extracellular to intracellular water volume was higher in hypoxemic lambs (0.69 +/- 0.10 versus 0.55 +/- 0.04, p < 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)
This paper reviews immunoaffinity CE procedures developed since 1998 for drug, hormone, and disease marker analyses of body fluids and tissues. Immunoaffinity CE and related techniques are described. Examples of clinical applications are included.
Eleven diphenylmethane antihistaminic drugs and their analogues were tested for their detection by capillary gas chromatography (GC) with surface ionization detection (SID). The GC-SID response was highest for doxylamine, diphenhydramine and orphenadrine and lowest for terodiline, clemastine and pipethanate. The detection limits for drugs with the highest response were 2-5 pg (ca. 6-20 fmol) on-column (100-250 pg/ml of body fluid). The detection limits with GC-SID were 10-100 times higher than those with GC with nitrogen-phosphorus detection. A detailed procedure for the isolation of the antihistaminics from human whole blood and urine by the use of Sep-Pak C18 cartridges, prior to GC-SID, is also presented. The recoveries of the drugs (50 or 500 pmol), which had been added to 1 ml of body fluids, were > 60%. The baselines remained steady as the column temperature was increased and the background was clean, especially for whole blood extracts.