PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Solid Phase Microextraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33Linked to original sources

Preparation and characteristics of sol-gel-coated calix[4]arene fiber for solid-phase microextraction.

5,11,17,23-Tetra-tert-butyl-25,27-diethoxy-26,28-dihydroxycalix[4]arene/hydroxy-terminated silicone oil coated fiber was first prepared and applied for solid-phase microextraction (SPME) with sol-gel technology. The possible sol-gel mechanism was discussed and confirmed by IR spectra. It showed wonderful selectivity and sensitivity to polar (aromatic amines), nonpolar (benzene derivatives, polycyclic aromatic hydrocarbons) and high boiling point compounds (phthalates) and the extraction equilibria were reached quite fast. The coating has high thermal stability (380 degrees C) and solvent stability (organic and inorganic), thus its lifetime is longer than conventional fibers. In addition, it has surprising fiber-to-fiber and batch-to-batch reproducibility. The detection limits were quite low and the linear ranges were pretty broad for all analytes.

Calixarenes↗

System for the generation of standard gas mixtures of volatile and semi-volatile organic compounds for calibrations of solid-phase microextraction and other sampling devices.

Standard gases are used for quality control and quality assurance, development of analysis methods and novel air sampling devices. The use of solid-phase microextraction (SPME) and other novel technologies for research in the area of air sampling and analysis requires systems/devices for reliable standard gas generation and sampling. In this paper we describe a new gas standard generating system for volatile organic compounds (VOCs) and semi-VOCs that was designed, built, and tested to facilitate fundamental and applications research with SPME. The system provided for the generation of a wide range of VOC/semi-VOC concentrations and mixing various standard gases, estimation of detection limits, testing the effects of sampling time, air temperature and relative humidity, testing the effects of air velocity and ozone on sampling/extractions. The system can be also used for calibrations of analytical instrumentation, quality control and quality assurance checks, and cross-validations of SPME with/and other sampling techniques.

Calibration↗

Advanced method using microwaves and solid-phase microextraction coupled with gas chromatography-mass spectrometry for the determination of pyrethroid residues in strawberries.

A microwave-assisted desorption method was developed and coupled with solid-phase microextraction and GC-MS for the analysis of pyrethroid residues in strawberries. In the first step, pyrethroid analytes were desorbed from the whole fruits in an aqueous acetonitrile solution at 50% under microwave assistance, so preventing these compounds to be captured with strong matrix effects by endogenous constituents. Then, the 100 microm poly(dimethylsiloxane)-coated fibre was exposed for 30 min in the obtained extracting solution. Calibration curves, realised from blank strawberries spiked at different concentrations with standards, showed a linear range between 1 microg/kg and 250 microg/kg with r2 > 0.992 and variation coefficients below 15%. Limits of detection and quantitation were found lower than 14 microg/kg and 40 microg/kg, respectively. Observed analysis results by using this method and relative to field incurred strawberry samples were also compared to those obtained by two accredited trading laboratories using traditional methods.

Adsorption↗

Investigation of photodegradation products generated after UV-irradiation of five polybrominated diphenyl ethers using photo solid-phase microextraction.

In this study, the photoinduced degradation of five polybrominated diphenyl ethers (PBDEs), BDE-47, BDE-100, BDE-99, BDE-154 and BDE-153, is studied using solid-phase microextraction polydimethylsiloxane fibers as photolytic support. PBDEs are extracted from aqueous solutions using SPME fibers that are subsequently exposed to UV irradiation for different times (from 2 to 60 min). Photodegradation kinetics of the five PBDEs, tentative identification and photochemical behavior of the generated photoproducts, as well as photodegradation pathways, have been studied employing this on-fiber approach technique (photo-SPME) followed by gas chromatography-mass spectrometry analysis. Aqueous photodegradation studies have also been performed and compared with photo-SPME. All the photoproducts detected in the aqueous experiments were previously found in the photo-SPME experiments. In this study, reductive debromination by successive losses of bromine atoms is confirmed as the main photodegradation pathway of PBDEs. A large number of PBDEs were obtained as photoproducts of the five target analytes. Other mechanism of photodegradation observed was intramolecular cyclization from the homolytic dissociation of the C-Br bond; thus, polybromo-dibenzofurans were generated. This work contributes to the study of the photodegradation of PBDEs and shows the potential of photo-SPME to evaluate the photo-transformation of organic pollutants.

Ethers↗

Determination of chromium(III) in water by solid-phase microextraction with a polyimide-coated fiber and gas chromatography-flame photometric detection.

A method for the determination of trace Cr(III) in aqueous solution by solid-phase microextraction (SPME) coupled with gas chromatography (GC)-flame photometric detection (FPD) was developed. Aqueous Cr(III) was first converted to the volatile chromium trifluoroacetylacetonate (Cr(tfa)3) by derivatization with 1,1,1-trifluoroacetylacetone (Htfa), followed by SPME extraction using a polyimide-coated silica fiber. The distribution constants (K) of derivatized cis- and trans-Cr(tfa)3 between the polyimide phase and aqueous phase were 2012 and 2214, respectively. The two Cr(tfa)3 isomers extracted can be efficiently separated by a DB-210 GC column within 9 min. Selective detection of Cr was performed by a FPD equipped with a 385-nm long-pass filter. Linearity (r> 0.99) over the concentration range 5-300 ng ml(-1) Cr was obtained and the limit of detection was 2 ng ml(-1) Cr. The relative standard deviation was 7% at 10 ng ml(-1) Cr (n = 5). Applicability of this method to water analysis was tested by analyzing the chromium content in a reference standard water sample and an industrial effluent.

Chromatography, Gas↗

Focused microwave-assisted extraction combined with solid-phase microextraction and gas chromatography-mass spectrometry for the selective analysis of cocaine from coca leaves.

An effective combination of focused microwave-assisted extraction (FMAE) with solid-phase microextraction (SPME) prior to gas chromatography (GC) is described for the selective extraction and quantitative analysis of cocaine from coca leaves (Erythroxylum coca). This approach required switching from an organic extraction solvent to an aqueous medium more compatible with SPME liquid sampling. SPME was performed in the direct immersion mode with a universal 100 microm polydimethylsiloxane (PDMS) coated fibre. Parameters influencing this extraction step, such as solution pH, sampling time and temperature are discussed. Furthermore, the overall extraction process takes into account the stability of cocaine in alkaline aqueous solutions at different temperatures. Cocaine degradation rate was determined by capillary electrophoresis using the short end injection procedure. In the selected extraction conditions, less than 5% of cocaine was degraded after 60 min. From a qualitative point of view, a significant gain in selectivity was obtained with the incorporation of SPME in the extraction procedure. As a consequence of SPME clean-up, shorter columns could be used and analysis time was reduced to 6 min compared to 35 min with conventional GC. Quantitative results led to a cocaine content of 0.70 +/- 0.04% in dry leaves (RSD <5%) which agreed with previous investigations.

Chemical Fractionation↗

Solid-phase microextraction for the determination of systemic and non-volatile pesticides in river water using gas chromatography with nitrogen-phosphorous and electron-capture detection.

A solid-phase microextraction (SPME) method combined with gas chromatography with nitrogen-phosphorous and electron capture detection for the analysis of the pesticides terbumeton, metribuzine, isomethiozine, pyridafenthion and triadimenol in river water has been developed. For this purpose, polyacrylate and polydimethylsiloxane coated fibres have been utilised and the factors affecting throughput, precision and accuracy of the SPME method have been investigated and optimised. These factors include: matrix influence, adsorption time, pH, salt effect, desorption time, temperature and also the lapse of time between sampling and injection. The performed analytical procedure showed detectability ranging from 2.0 ng l(-1) to 3.0 microg l(-1) and precision from 1.9 to 27.7% (as relative standard deviation) depending on the pesticide, the fibre and the detector used. The results demonstrate the suitability of the SPME method to analyse these non-volatile pesticides in river water.

Chromatography, Gas↗

Headspace solid-phase microextraction analysis of 3-alkyl-2-methoxypyrazines in wines.

A procedure to determine 3-alkyl-2-methoxypyrazines in wines is described. It is based on the headspace solid-phase microextraction (HS-SPME) technique after a clean-up of the sample by distillation (previously acidified to pH 0.5) to remove ethanol and other volatile compounds that can interfere in the SPME. Determination is performed by means of capillary gas chromatography using a nitrogen-phosphorus detector. The method allows quantification of 3-isobutyl-2-methoxypyrazine, 3-sec-butyl-2-methoxypyrazine and 3-isopropyl-2-methoxypyrazine at their natural concentration levels and below their sensory thresholds in Cabernet Sauvignon and Merlot wines. The method was successfully applied to experimental red wines and the evolution of their pyrazine contents during the winemaking process was monitored. Pyrazine content increased during the first maceration day but did not change significantly during alcoholic and malolactic fermentation. Final contents in wines were 12-27 ng/l of 3-isobutyl-2-methoxypyrazine and 5-10 ng/l of 3-sec-butyl-2-methoxypyrazine.

Chromatography, Gas↗

Determination of pyrimethanil and kresoxim-methyl in green groceries by headspace solid-phase microextraction and gas chromatography-mass spectrometry.

A method for determination of trace amounts of the fungicides pyrimethanil and kresoxim-methyl in green groceries, previous headspace solid-phase microextraction (HSSPME), was developed using gas chromatography-mass spectrometry and selected ion monitoring (GC-MS, SIM). Both fungicides were extracted with a fused-silica fiber coated with 85 microm polyacrylate. The effects of pH, ionic strength, extraction and desorption times as well as the extraction temperature were studied. The linear concentration range of application was 12.5-250 ng g(-1) for both compounds, with detection limits of 1.8-2.0 ng g(-1) for pyrimethanil and 2.8-3.1 ng g(-1) for kresoxim-methyl. SPME/GC-MS analysis yielded good reproducibility (RSD between 7.4 and 15.0%). It was applied to check the eventual existence of pyrimethanil and kresoxim-methyl above the detection limits on grapes, strawberries, tomatoes and ketchup samples. The method validation was completed with spiked matrix samples. It can be applied as a monitoring tool in grapes, strawberries, tomatoes and ketchup samples.

Fruit↗

High-speed gas chromatographic analysis of solvents in pharmaceuticals using solid phase microextraction.

A simple, inexpensive and rapid analytical approach for the determination of organic volatile impurities in pharmaceutical drug substances is developed, where sample preparation step was conducted using solid phase microextraction (SPME), followed by a fast GC separation. With an extraction time between 3 and 5 min and separation of 13 solvents in less than 3 min employing fast temperature programming using resistively heated column, organic volatile impurities can be analyzed within a total analysis time of 6-9 min. Various SPME phases were evaluated towards sensitivity and selectivity for the extraction of 13 commonly found solvents in drug substances dissolved in dimethyl sulfoxide and water. A 2-cm Carboxen/polydimethyl siloxane/divinylbenzene (Carboxen/PDMS/DVB) phase and a 65-microm DVB/PDMS phase showed better sensitivity towards these solvents when extracted from organic and aqueous matrix in comparison with the sensitivity obtained with direct injection approach. Extraction parameters such as extraction time, extraction stir rate, etc. are discussed. %RSD of peak area of replicate extraction was between 2 and 10% when 100 microm PDMS was used for extracting solvents from aqueous matrix. When DVB/PDMS fiber was evaluated for precision, %RSD of peak area from replicate extractions of solvents from organic matrix was between 2 and 8%. One-hundred micrometer PDMS showed excellent linearity from 10 to 500 microg/ml for analytes extracted from water solutions. On the other hand, DVB/PDMS phase showed better linearity than Carboxen/PDMS/DVB fiber when it was used to extract analytes in the concentration range of 10-5000 microg/ml from organic matrix.

Acetates↗

Application of solid-phase microextraction to the quantitative analysis of 1,8-cineole in blood and expired air in a Eucalyptus herbivore, the brushtail possum (Trichosurus vulpecula).

We have developed two solid-phase microextraction (SPME) methods, coupled with gas chromatography, for quantitatively analysing the major Eucalyptus leaf terpene, 1,8-cineole, in both expired air and blood from the common brushtail possum (Trichosurus vulpecula). In-line SPME sampling (5 min at 20 degrees C room temperature) of excurrent air from an expiratory chamber containing a possum dosed orally with 1,8-cineole (50 mg/kg) allowed real-time semi-quantitative measurements reflecting 1,8-cineole blood concentrations. Headspace SPME using 50 microl whole blood collected from possums dosed orally with 1,8-cineole (30 mg/kg) resulted in excellent sensitivity (quantitation limit 1 ng/ml) and reproducibility. Blood concentrations ranged between 1 and 1380 ng/ml. Calibration curves were prepared for two concentration ranges (0.05-10 and 10-400 ng/50 microl) for the analysis of blood concentrations. Both calibration curves were linear (r(2)=0.999 and 0.994, respectively) and the equations for the two concentration ranges were consistent.

Air↗

Optimization of solid-phase microextraction analysis for studying change of headspace flavor compounds of banana during ripening.

The changes of headspace flavor compounds of banana during ripening were studied by a solid-phase microextraction (SPME) method. Three temperatures, 20, 25, and 30 degrees C, were used to investigate the temperature effect on the changes of headspace flavor compounds of banana during ripening over a period of 8 days. Banana juice concentration, salt concentration, time, and temperature were investigated for optimizing the SPME method. The most suitable concentrations of banana juice and salt were 33.3 and 20%, respectively. The optimal temperature and time are about 50 degrees C and 48 min, respectively. Increasing ripening temperature could accelerate ripening rate. Ethanol developed most rapidly at 30 degrees C, whereas amounts of the other investigated flavor compounds stored at 25 degrees C were greater than those of the ones stored at 20 or 30 degrees C.

Chemistry Techniques, Analytical↗

Screening procedure for 21 amphetamine-related compounds in urine using solid-phase microextraction and gas chromatography-mass spectrometry.

A specific, sensitive, and rapid procedure for the screening of 21 amphetamine-related compounds in urine is developed using solid-phase microextraction (SPME) and gas chromatography-mass spectrometry. Very clean extracts are obtained in one step with SPME using silica fibers coated with a 100-micron polydimethylsiloxane stationary phase. Temperature, time, pH, and salt saturation are optimized to obtain consistent extraction. An excellent chromatographic separation of the underivatized analytes is obtained with a specially treated nonpolar capillary column (Supelco PTA-5, 30 m x 0.32-mm i.d., 0.5-micron film thickness) dedicated to amino compounds. Selected ion monitoring of three fragments per analyte and one for each of the three deuterated internal standards elicits a high selectivity and detection limits between 1 and 50 ng/mL (i.e., low enough to verify positive results obtained with immunochemical assays). The method is linear in a narrow range (from the detection limit up to 500 ng/mL) when all the amphetamines are assayed together but shows a good linearity up to 2000 ng/mL when the molecules are determined individually. Repeatability is not satisfactory for all compounds but could probably be improved by strictly controlling the extraction time (e.g., by automating the whole procedure using an autosampler). The use of SPME reduces the interference due to urinary low-volatility organic compounds and avoids the risks related to the use of organic solvents. To our knowledge, this technique is the first one allowing the sensitive determination of such a number of amphetamine analogs.

Amphetamine↗

A convenient method for epichlorohydrin determination in water using headspace-solid-phase microextraction and gas chromatography.

A simple procedure for epychlorohydrin determination in water is presented. In order to optimize the epichlorohydrin extraction conditions in water using headspace (HS)-solid-phase microextraction (SPME), followed by gas chromatography, an experimental design in two steps is performed. Firstly, a 2(5-2) fractional factorial design for screening the significant variables is used. Secondly, a central composite design for optimizing them is carried out. The best experimental conditions are the followings: poly(dimethysiloxane)-divinylbenzene coating fiber; 20 min extraction time; 5 degrees C extraction temperature; 300 g/L sodium chloride; and 20 mL HS volume in a 40-mL vial. Using the previous extraction conditions with gas chromatography (GC)-flame ionization detection equipment, a limit of detection (LOD) of 1.8 microg/L and a relative standard deviation (RSD) of 3.8% (for 25 microg/L) are obtained. With a GC electron capture detection equipment the RSD is 6.6% (for 5 microg/L), and the LOD found is lower (0.08 microg/L). The method is applied to the analysis of water from four treatment plants at the entrance and effluent stream. The standard addition method is used to quantitate the epichlorohydrin that is found in the raw water of the three wastewater treatment plants.

Chromatography, Gas↗

Analysis of ethanol and methanol in human body fluids by headspace solid phase microextraction coupled with capillary gas chromatography.

A new method for extraction and analysis of ethanol and methanol in human whole blood, urine and saliva samples based on headspace solid phase microextraction (SPME) using silver sulfide (Ag(2)S) and polyvinyl chloride (PVC) coated on silver wire is described. Unlike commercial fibers, which are coated on fused silica, the proposed fiber has a metallic base to which the coating adheres very strongly. Due to metallic base, this fiber is very durable and is thermally stable up to 250 degrees C. After optimization of coating composition and microextraction conditions, the fiber was used for sampling of methanol and ethanol from human body fluids prior to capillary gas chromatographic analysis. The high recovery (>94%), low detection limits (5.6 mg/L for ethanol and 12.8 mg/L for methanol) and excellent linearity (>0.9900) of calibration graphs made the proposed method suitable for this purpose.

Body Fluids↗

Analysis of anatoxin-a in biological samples using liquid chromatography with fluorescence detection after solid phase extraction and solid phase microextraction.

Anatoxin-a is a naturally occurring, potent neurotoxin produced by some species of cyanobacteria in freshwaters. This toxin, which is a potential health hazard, especially to animals, has been determined in different biological matrices such as several cyanobacterial cultures and water samples and carps and mussels tissue using a sensitive High Performance Liquid Chromatography with Fluorescence detection method. Sonication was the technique selected for the extraction of intracellular anatoxin-a and solid phase extraction using weak cation exchange was used for the concentration and purification of the samples. 4-Fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F) was used to convert anatoxin into a highly fluorescent derivative. Recovery experiments were performed for each type of matrix used in this work, and adequate values were obtained (71-87%). Limits of detection for anatoxin-a were estimated to be in the ng/L and ng/g level for water and cyanobacterial samples, respectively. The results obtained were also compared with those obtained after using solid phase microextraction, as an alternative for the extraction and purification of the samples. Advantages and disadvantages regarding to the efficiency for impurities removal, simplicity and rapidity and the potential for concentration enhancement of using both methodologies have been also discussed.

Chromatography, High Pressure Liquid↗

Electrospray mass spectrometry of trimethyllead and triethyllead with in-tube solid phase microextraction sample introduction

A study of positive ionization electrospray mass spectrometry (ES-MS) was performed on trimethyllead (TML) and triethyllead (TEL). The system consisted of in-tube solid phase microextraction (SPME) coupled directly to an electrospray mass spectrometer. Fragmentation patterns of compounds were observed by applying different fragmentation voltages. High voltages produced sufficient fragmentation to elucidate the dissociation of the trialkyllead compounds. Electrospray mass spectrometry has been shown to be a suitable detection system for organolead speciation. Applying fragmentation energy programming, it might be possible to obtain in parallel the molecular and atomic signals of lead compounds. Copyright 1999 John Wiley & Sons, Ltd.

Journal Article↗

Evaluation of solid-phase microextraction with PDMS for air sampling of gaseous organophosphate flame-retardants and plasticizers.

As an inexpensive, simple, and low-solvent consuming extraction technique, the suitability of solid-phase microextraction (SPME) with polydimethylsiloxane (PDMS) sorbent was investigated as a quantitative method for sampling gaseous organophosphate triesters in air. These compounds have become ubiquitous in indoor air, because of their widespread use as additive flame retardants/plasticizers in various indoor materials. Results obtained by sampling these compounds at controlled air concentrations using SPME and active sampling on glass fibre filters were compared to evaluate the method. A constant linear airflow of 10 cm s(-1) over the fibres was applied to increase the extraction rate. For extraction of triethyl phosphate with a 100-microm PDMS fibre, equilibrium was achieved after 8 h. The limit of detection was determined to be less than 10 pg m(-3). The PDMS-air partition coefficients, Kfs, for the individual organophosphate triesters were determined to be in the range 5-60 x 10(6) at room temperature (22-23 degrees C). Air measurements were performed utilising the determined coefficients for quantification. In samples taken from a lecture room four different airborne organophosphate esters were identified, the most abundant of which was tris(chloropropyl) phosphate, at the comparatively high level of 1.1 microg m(-3). The results from SPME and active sampling had comparable repeatability (RSD less than 17%), and the determined concentrations were also similar. The results suggest that the investigated compounds were almost entirely associated with the gaseous phase at the time and place sampled.

Adsorption↗