Effect of angular traction on the performance of modern vacuum extractors.
Explore the source record for details and available documents.
SEARCH · PubMed Health
Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
We have studied the outcome of labor induction in 145 postterm pregnant women in whom gestational age was properly assessed by ultrasound scanning. The induction techniques were adapted to the cervical states of the patients. Seventy-five patients (32 nulliparous and 43 multiparous) with favorable cervical states were successfully induced with intravenous oxytocin. In this group the frequency of Caesarean section was 2%. Seventy patients (45 nulliparous and 25 multiparous) with unripe cervices received 0.5 mg PGE2 in viscous gel intracervically to prime the cervix and to induce labor; 38 (52%) were induced into labor after a single PGE2-gel application whereas 26 (48%) needed labor augmentation with intravenous oxytocin after PGE2-gel obtained cervical ripening. In 6 of the 20 patients the cervix did not ripen and the PGE2-gel application had then to be repeated. The frequency of cesarean sections was 11%. In 5 out of the 145 patients (4%) the fetuses had signs of intrauterine growth retardation (IUGR) as assessed by ultrasound scanning, and postmaturity as verified by pediatric examination at delivery. All these fetuses belonged to nulliparous women with unripe cervices and all had to be delivered instrumentally (3 by cesarean section and 2 by ventouse) indicating the fragility of these children. If postterm pregnancy is complicated by an unfavorable cervical state intracervical application of PGE2-gel seems to be an efficient method to prime the cervix and to induce labor. In most patients an uncomplicated vaginal delivery can be achieved by this procedure. However, nulliparous women with unfavorable cervices and signs of IUGR constitute a high risk group of patients at labor induction.
A total of 400 primiparous patients who were delivered by vacuum extractor were studied. The patients were divided in two groups: Group A included 200 patients who were delivered by metal cup vacuum extractor and Group B consisted of 200 patients who were delivered by rubber cup vacuum extractor. There were no statistically significant differences in the mean maternal age, mean gestational age, mean neonatal birth weight, indications for operative delivery, occipital positions and head stations between the two groups. No differences were found in the rates of birth canal trauma (11% vs. 12.5%), major neonatal scalp trauma (6.5% vs. 5.5%), neonatal jaundice (15.5% vs. 13.5%) and Apgar score. From this study we can conclude that both metal and silicone cups are equally satisfactory for vacuum extraction.
BACKGROUND: The vacuum extractor is being increasingly advocated as the instrument of first choice for assisted vaginal delivery. It is widely believed that the vacuum cup will dislodge before causing serious fetal trauma. CASE: Rotational delivery of a term infant was effected using a vacuum extractor. A 6-cm Malmström metal cup with a paramedian application was in place for 12 minutes. The vacuum pressure developed was 0.8 kg/cm2. Four traction efforts with contractions were required to deliver the fetal head. A neonatal skull x-ray the following day showed a comminuted parietal bone fracture at the vacuum cup application site. Management was conservative, and the infant's neurologic behavior remained normal. CONCLUSION: The vacuum extractor exerts considerable traction force. Fetal skull fracture can result, and its true incidence may be higher than expected, considering that few neonates with normal neurologic behavior undergo skull x-ray.
Twenty-one women in the 10th-12th week of pregnancy were treated prior to vacuum aspiration with vaginal suppositories containing 16, 16-dimethyl-PGE2 (free acid). An average total dose of 3.4 mg led to abortion or adequate cervical dilatation in all patients. Based upon previous experience with the compound, no prophylactic anti-emetic or anti-diarrhetic medication was given. Gastrointestinal side effects were minimal. Excessive bleeding was not observed. In two cases, slight temperature elevation was noted prior to abortion. The low incidence of side effects in combination with the effectiveness of the compound help to make this method an attractive therapeutic adjunct to vacuum aspiration beyond the 10th week of gestation. Under the experimental conditions of this study, the results suggest that vaginally administered 16, 16-dimethyl-PGE2 can be a safe and effective method for cervical dilatation before vacuum aspiration.
The vacuum extractor has become a widely used instrument in many settings. It has proven to be a reliable method of ensuring safe passage of the fetus and/or enhancing maternal effort during the second stage of labor. The principles of vacuum-assisted birth are learned relatively easily and have been incorporated into many nurse-midwifery practices. This article reviews the principles of vacuum extraction as they apply to the practice of nurse-midwifery. Vacuum extractors available to nurse-midwives are compared. Nurse-midwives are familiarized with vacuum extraction so that they can make an informed choice concerning the vacuum extractor as an appropriate tool within their practice. This article is not intended to teach nurse-midwives to use the vacuum extractor. It does, however, provide guidelines for credentialing those nurse-midwives choosing to incorporate the principles of vacuum extraction into their practice.
In much of the developing world, sharp curettage (SC) is the most commonly used technique for treating incomplete abortion. The procedure is usually performed in a hospital setting where physicians and operating theatres are available; it often involves light to heavy sedation for pain control and an overnight hospital stay for patient recuperation and monitoring. This study examined the hypothesis that use of manual vacuum aspiration (MVA)--a variation of vacuum aspiration (VA)--would be less costly than SC and thus be advantageous to healthcare systems with limited resources. The purpose of the study was to identify and, where possible, to explain the factors that contributed to cost differences between MVA and SC for treatment of incomplete abortion. To achieve this objective, researchers observed patient management and documented resource use at hospital sites in Kenya and Mexico. The results of the study support the researchers' hypothesis that, in most cases, treatment with MVA required a shorter patient stay and fewer hospital resources than SC, as the two techniques were practiced at the various study sites. The policy decision to adopt MVA, supported by procurement of instruments and incorporation of training in its use, is the basic prerequisite to achieving reduced levels of resource use. The study results also suggest that the full advantages of MVA can be realized only if it is introduced in conjunction with certain changes in patient management, such as offering outpatient treatment for incomplete abortion.
Explore the source record for details and available documents.
OBJECTIVE: Side-by-side comparisons of short-term maternal and neonatal outcomes for spontaneous vaginal delivery, instrumental vaginal delivery, planned caesarean section and caesarean section during labor in patients matched for clinical condition, age, and week of gestation are lacking. This case-controlled study was undertaken to evaluate short-term maternal and neonatal complications in a healthy population at term by mode of delivery. STUDY DESIGN: Four groups of healthy women, with antenatally normal singleton pregnancies at term, who underwent instrumental vaginal delivery (no. 201), spontaneous delivery (no. 402), planned caesarean section without labor (no. 402) and caesarean section in labor (no. 402) have been retrospectively selected. Outcome measures were maternal and neonatal short-term complications. Odds ratios (OR) and 95% confidence intervals (CI) were calculated. RESULTS: Maternal complications were mostly associated with forceps-assisted and vacuum-assisted instrumental deliveries (OR: 6.9; 95% CI: 2.9-16.4 and OR 3.0; 95% CI 1.1-8.8, respectively, versus spontaneous deliveries). No significant differences in overall complications were observed between spontaneous vaginal deliveries and caesarean sections, whether planned or in labor. By comparison with caesarean sections in labor, instrumental deliveries significantly increased the risk of complications (OR: 3.2; 95% CI: 1.6-6.5). Neonatal complications were also mostly correlated with forceps-assisted and vacuum-assisted instrumental deliveries (OR: 3.5; 95% CI: 1.9-6.7 and OR 3.8; 95% CI 2.0-7.4, respectively, versus spontaneous deliveries). By comparison with caesarean sections in labor, instrumental vaginal deliveries significantly increased the risk of complications (OR: 4.2; 95% CI: 2.4-7.4). CONCLUSIONS: In healthy women with antenatally normal singleton pregnancies at term, instrumental deliveries are associated with the highest rate of short-term maternal and neonatal complications.
OBJECTIVE: To evaluate risk factors associated with failed attempts of vacuum extraction and their outcomes. PATIENTS AND METHODS: All trial vacuum extractions (metal Minicup) from 1992 to 2000 in Besançon University Hospital Center were retrospectively analysed, namely 2447 cases. Univariate and multivariate analyses of failed vacuum extraction risk factors and descriptive analyse of outcomes were performed. RESULTS: The rate of failed vacuum extractions was 3.47% (85/2447). A multivariate analysis showed the following independent risks factors in failed extraction: extraction above pelvic level + 2 (OR = 1.8; CI 95%: 1.1-3), newborn weight (OR = 2.9; CI 95%: 1.8-4.9), parity >2 (OR = 0.08; CI 95%: 0.01-0.6). In case of failed vacuum extraction, newborns had a significantly higher rate of Apgar score <7 at 1 min (P = 0.0002), but not at 5 min. These newborns were most regularly admitted in pediatric care units (P = 0.01). CONCLUSION: The failed trial attempt vacuum extraction rate stays low. These failed instrumental extractions are more common in an extraction above pelvic + 2, a high fetal weight and an arrest during the second stage of labor. There is an increased adverse neonatal outcome. Clinical fetal weight estimation and diagnosis of presentation level in mother pelvis must be performed before vacuum extraction.
OBJECTIVES: This study compares the gynaecological symptoms of women who have undergone an induced abortion to those who have not. We also compare the gynaecological side effects, in particular the infectious symptoms, following an induced abortion, according to the abortion technique, medical and surgical, in the year after the abortion. PATIENTS AND METHODS: A representative sample of 2863 women, aged 18 to 44, was interviewed by telephone between September 2000 and January 2001. Of these women, 401 declared an abortion in the last 5 years. Analysis of the gynaecological side effects according to the abortion technique was performed among the 199 women who terminated their pregnancy before the 8th week of amenorrhoea. RESULTS: Women with a history of induced abortion had a higher sexual risk profile than those with no such history. They also more frequently reported genital infectious symptoms. The comparison between medical and surgical abortions shows that women who had a medical abortion were more likely to report heavy and prolonged bleeding. On the contrary, we found no difference of infectious symptoms between the two techniques. DISCUSSION AND CONCLUSION: Our study does not support the idea of a reduction of infectious complications related to medical as opposed to surgical abortions. However, given the rapid diffusion of medical abortion, it seems important to carry on the investigations on the side effects related to medical abortions, in order to prevent them if necessary.
OBJECTIVE: To identify, from the best available evidence, underutilized and promising technologies that may reduce maternal mortality from obstructed labor. METHODS: The author sought systematic reviews of randomized trials, individual randomized trials, and, in the absence of randomized data, non-randomized studies and clinical consensus. Data were presented according to the level of the evidence. RESULTS: Obstructed labor causes approximately 8% of maternal deaths, and indirectly contributes to a greater percentage. Proven or widely accepted technologies that help reduce mortality from obstructed labor include contraception, external cephalic version, the partogram, augmentation of labor, selective amniotomy, selective episiotomy, vacuum extraction, caesarean section, symphysiotomy, and destructive procedures for non-viable fetuses. Technologies of uncertain usefulness include maternal height and shoe size, vaginal cleansing, upright posture for delivery and vaginal lubrication. Unuseful technologies include pelvimetry, estimating fetal weight, early labor induction, routine amniotomy and augmentation, routine episiotomy, and starvation during labor. CONCLUSION: Access to well-established technologies, particularly safe caesarean section, can reduce maternal mortality in resource-poor countries.
Explore the source record for details and available documents.
OBJECTIVE: To evaluate whether the traction force indicator in a ventouse device gave an accurate estimation of the force applied. METHODS: The study was carried out at the Derby City Hospital. An estimate of measurement errors was made by analyzing the standard deviation of the residuals for 30 Kiwi OmniCup devices (Clinical Innovations, Abingdon, Oxfordshire, England) and a standard industrial spring balance. RESULTS: The measurement errors for the traction forces were very small and acceptable for the OmniCup. The overall estimate of measurement errors was 0.45 kg (1.35 lb). CONCLUSION: The overall measurement error for the traction force indicator of the OmniCup was found to be very small. Injuries associated the ventouse, such as cephalohematomas and subgaleal hemorrhages, may be minimized if the recommended limits for a safe traction force are not exceeded.
OBJECTIVE: Is vacuum extraction-the method of first choice for assisting vaginal delivery in case of prolonged labor-losing ground in the developing world? And if it is, why? The paper tries to answer these disturbing questions, and examine their consequences. METHODS: A rapid Knowledge-Attitude-Practice (KAP) survey was conducted during 2003-2004 on the question of assisted vaginal delivery (AVD) by the use of the vacuum extractor. Public health specialists and obstetricians from 121 developing countries were consulted about their knowledge of the method in their country, its reputation (i.e. their attitude) and its use (practice). RESULTS: Overall 48% of the respondent countries have confirmed knowledge, positive attitude, teaching and countrywide use of the method, while 37% said the method is known and used by only a limited number of specialists who do not teach it, and 15% admitted no knowledge and therefore no use. CONCLUSION: Given the evidence-based international recognition of the benefits of vacuum extraction (if practiced correctly and for appropriate indications), it is unjust to deprive women with prolonged labor (and their fetuses) of a simple intervention that can contribute to reducing life threatening complications. This unsophisticated worldwide survey, while not providing in-depth explanations, calls for rehabilitation of vacuum extraction in countries where it is disappearing and surgical extraction is not yet readily accessible to all women with prolonged labor.
OBJECTIVE: Our objective was to describe the effect of off-axis traction on the performance of modern vacuum extractors. STUDY DESIGN: Eight vacuum extractors were examined in the laboratory with a force indicator and fetal cephalic model. Devices evaluated included the 6 cm Malmstrom, Mity-Vac, M-Type, O'Neil, Posterior, Silc, Tender-Touch, and silicone elastomer. Maximal tractive force (pop-off) was measured for each device at 10-degrees increments from the vertical. RESULTS: Multivariate regression analysis described the best model as follows: Maximal tractive force = Constant + Angle + Vacuum (p < 0.05). The partial regression coefficients for angle were negative in all devices except the Posterior cup. At increasing angles of off-axis traction, maximal tractive force decreased in the following order: Silc, silicone elastomer, Tender-Touch, M-Type, Mity-Vac, O'Neill, Malmstrom, and Posterior. CONCLUSIONS: Application of oblique traction resulted in a linear decline in maximal tractive force. An understanding of in vitro performance may allow tailoring of cup selection to the clinical situation.
Explore the source record for details and available documents.