PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “biosensor”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33Linked to original sources

Detection of water-borne E. coli O157 using the integrating waveguide biosensor.

Escherichia coli O157:H7, the most common serotype of enterohemorrhagic E. coli (EHEC), is responsible for numerous food-borne and water-borne infections worldwide. An integrating waveguide biosensor is described for the detection of water-borne E. coli O157, based on a fluorescent sandwich immunoassay performed inside a glass capillary waveguide. The genomic DNA of captured E. coli O157 cells was extracted and quantitative real-time PCR subsequently performed to assess biosensor-capture efficiency. In vitro microbial growth in capillary waveguide is also documented. The biosensor allows for quantitative detection of as few as 10 cells per capillary (0.075 ml volume) and can be used in conjunction with cell amplification, PCR and microarray technologies to positively identify a pathogen.

Biosensing Techniques↗

Palm tree peroxidase-based biosensor with unique characteristics for hydrogen peroxide monitoring.

Three amperometric enzyme electrodes have been constructed by adsorbing anionic royal palm tree peroxidase (RPTP), anionic sweet potato peroxidase (SPP), or cationic horseradish peroxidase (HRP-C) on spectroscopic graphite electrodes. The resulting H(2)O(2)-sensitive biosensors were characterized both in a flow injection system and in batch mode to evaluate their main bioelectrochemical parameters, such as pH dependency, I(max), K(M)(app), detection limit, linear range, operational and storage stability. The obtained results showed a distinctly different behavior for the plant peroxidase electrodes, demonstrating uniquely superior characteristics of the RPTP-based sensors. The broader linear range observed for the RPTP-based biosensor is explained by a high stability of this enzyme in presence of H(2)O(2). The higher storage and operational stability of RPTP-based biosensor as well as its capability to measure hydrogen peroxide under acidic conditions connect with an extremely high thermal and pH-stability of RPTP.

Arecaceae↗

Miniaturized glucose biosensor modified with a nitric oxide-releasing xerogel microarray.

An enzyme-based glucose biosensor modified to release nitric oxide (NO) via a xerogel microarray is reported. The biosensor design is as follows: (1) glucose oxidase (GOx) is immobilized in a methyltrimethoxysilane (MTMOS) xerogel layer; (2) a blended polyurethane/hydrophilic polyurethane coating prevents enzyme leaching and imparts selectivity for glucose; and (3) micropatterned xerogel lines (5 microm wide) separated by distances of 5 or 20 microm provide NO-release capability. This configuration allows for increased glucose sensitivity relative to sensors modified with NO-releasing xerogel films since significant portions of the sensor surface remain unmodified. Glucose diffusion to the GOx layer is thus less inhibited. The micropatterned NO-releasing biosensors generate sufficient NO levels to reduce both Pseudomonas aeruginosa and platelet adhesion without significantly compromising the enzymatic activity of GOx. The glucose response, linearity and stability of the NO-releasing micropatterned sensors are reported.

Absorption↗

Investigations of the antioxidant properties of plant extracts using a DNA-electrochemical biosensor.

In this work, the results of a method based on an electrochemical biosensor to detect DNA damage in vitro for the evaluation of the antioxidant properties of plant extracts are reported. The biosensor consisted of a dsDNA immobilized on a screen-printed electrode surface (SPE). DNA damage was promoted by the generation of the *OH radicals via Fenton-type reaction. The interaction of the radical species with immobilised DNA in the absence and presence of antioxidants was evaluated by means of changes in the guanine oxidation peak obtained by square wave voltammetry. The results demonstrated that the DNA-based biosensor is suitable as a rapid screening test for the evaluation of antioxidant properties of samples.

Antioxidants↗

Amperometric biosensor for hydrogen peroxide based on ferrocene-bovine serum albumin and multiwall carbon nanotube modified ormosil composite.

A novel amperometric biosensor for hydrogen peroxide (H(2)O(2)) was developed by entrapping horseradish peroxidase (HRP) in a new ormosil composite doped with ferrocene monocarboxylic acid-bovine serum albumin conjugate and multiwall carbon nanotubes (MWNTs). The ormosil was prepared using 3-(aminopropyl)triethoxysilane and 2-(3,4 epoxycyclohexyl)-ethyltrimethoxy silane as monomers. The encapsulated conjugate showed excellent electrochemistry and acted as an electron transfer mediator. The presence of MWNTs improved the conductivity of the composite film. This matrix showed a biocompatible microenvironment for retaining the native activity of the entrapped HRP and a very low mass transport barrier to the substrate, which provided a fast amperometric response to H(2)O(2). The proposed H(2)O(2) biosensor exhibited a linear range of 0.02-4.0 mM with a detection limit of 5.0 microM (S/N = 3) and a K(M)(app) value of 2.0 mM. It could be used for flow injection analysis of hydrogen peroxide with a liner range from 0.02 to 4.5 mM, sensitivity of 0.042 microA/mM and analytical time of 20 s per sample. This biosensor possessed good analytical performance and storage stability.

Adsorption↗

Development of a disposable pyruvate biosensor to determine pungency in onions (Allium cepa L.).

A disposable prototype pyruvate biosensor was constructed using pyruvate oxidase immobilised on mediated meldolas blue electrodes to determine pungency in onions (Allium cepa L.). The optimum operating potential was +150 mV (versus Ag/AgCl). A strong correlation between the biosensor response and untreated onion juice of known pyruvate concentration 2-12 micromol/g fresh weight (FW) was demonstrated. The biosensor was able to differentiate between low and high pungency onions. The detection limit using 1 unit of pyruvate oxidase was 1-2 micromol/g FW. Optimum concentrations of co-factors TPP, FAD and MgSO4 comprising the enzyme cocktail were determined as being 0.04, 0.1 and 30 mM, respectively.

Biosensing Techniques↗

Facile preparation of amperometric laccase biosensor with multifunction based on the matrix of carbon nanotubes-chitosan composite.

The carbon nanotubes-chitosan (CNTs-CS) composite provides a suitable biosensing matrix due to its good conductivity, high stability, and good biocompatibility. Enzymes can be firmly incorporated into the matrix without the aid of other cross-linking reagents. The composite is easy to form insoluble film in solution above pH 6.3. Based on this, a facilely fabricated amperometric biosensor by entrapping laccase into the CNTs-CS composite film has been developed. At pH 6.0, the fungi laccase incorporated into the composite film remains better catalytic activity than that dissolved in solution. The system is in favor of the accessibility of substrate to the active site of laccase, thus the affinity to substrates is improved greatly, such as 2,2'-azino-bis-(3-ethylbenzthiazoline-6-sulfonic acid) diammonium salt (ABTS), catechol, and O2 with Km values of 19.86 microM, 9.43 microM, and 3.22 mM, respectively. The major advantages of the as-prepared biosensor are: detecting different substrates (ABTS, catechol, and O2), possessing high affinity and sensitivity, durable long-term stability, and facile preparation procedure. On the other hand, the system can be applied in fabrication of biofuel cells as the cathodic catalysts based on its good electrocatalysis for oxygen reduction. It can be extended to immobilize other enzymes and biomolecules, which will greatly facilitate the development of biosensors, biofuel cells, and other bioelectrochemical devices.

Biosensing Techniques↗

Detection of clinically relevant point mutations by a novel piezoelectric biosensor.

Piezoelectric sensing is here applied to point mutation detection in human DNA. The mutation investigated is in the TP53 gene, which results inactivated in most cancer types. TP53 gene maps on chromosome 17 (17p13.1). It contains 11 exons and codifies for the relative protein, involved in cell proliferation. The TP53 gene has a wide mutation spectrum that is related to different tumours. In particular, those occurring in the structurally important L2 and L3 zinc-binding domains, have been linked to patient prognosis and more strongly to radiotherapy and chemotherapy resistance in several major cancers. For this reason, the identification of these mutations represents an important clinical target and biosensors could represent good candidate for fast mutation screening. In this paper, a DNA-based piezoelectric biosensor for the detection of the TP53 gene mutation at codon 248 is reported. A biotinylated probe was immobilised on the sensor surface via dextran-streptavidin modified surfaces. The sensor was optimised using synthetic oligonucleotides. Finally, the sensor system was successfully applied to polymerase chain reaction (PCR)-amplified real samples of DNA extracted from two cell lines, one normal (wild-type) and one mutated, carrying the mutation at codon 248 of the TP53 gene. The results obtained demonstrate that the DNA-based piezoelectric biosensor is able to detect the point mutations in PCR-amplified samples showing the potentialities of this approach for routine analysis.

Biosensing Techniques↗

Point-of-care biosensor systems for cancer diagnostics/prognostics.

With the growing number of fatalities resulting from the 100 or so cancer-related diseases, new enabling tools are required to provide extensive molecular profiles of patients to guide the clinician in making viable diagnosis and prognosis. Unfortunately with cancer-related diseases, there is not one molecular marker that can provide sufficient information to assist the clinician in making effective prognoses or even diagnoses. Indeed, large panels of markers must typically be evaluated that cut across several different classes (mutations in certain gene fragments--DNA; over/under-expression of gene activity as monitored by messenger RNAs; the amount of proteins present in serum or circulating tumor cells). The classical biosensor format (dipstick approach for monitoring the presence of a single element) is viewed as a valuable tool in many bioassays, but possesses numerous limitations in cancer due primarily to the single element nature of these sensing platforms. As such, if biosensors are to become valuable tools in the arsenal of the clinician to manage cancer patients, new formats are required. This review seeks to provide an overview of the current thinking on molecular profiling for diagnosis and prognosis of cancers and also, provide insight into the current state-of-the-art in the biosensor field and new strategies that must be considered to bring this important technology into the cancer field.

Biomarkers, Tumor↗

Structure and biosensor characteristics of complex between glucose oxidase and plasma-polymerized nanothin film.

The structure and biosensor characteristics of complex between glucose oxidase (GOD) and plasma-polymerized nanothin film (PPF), in which the thickness is several nanometers, were investigated by atomic force microscopy (AFM) and electrochemical measurement. The GOD molecules were densely adsorbed onto the PPF surface treated by nitrogen plasma and the individual GOD molecules were observed. Subsequently, the GOD densely packed array on the PPF surface was subsequently treated by plasma polymerization (overcoating). AFM image showed that the thicker film gave the smoother surface, indicating that the GOD adsorbed on the surface was embedded more deeply in PPF. The amperometric biosensor characteristics of the GOD-PPF complex on a platinum electrode showed the current increment due to the enzymatic reaction with glucose addition, indicating that enzyme activity was retained although the enzyme has been exposed to the plasma gas related to diffusion of the substrate. This means that under mild exposure to organic plasma, the enzyme does not become seriously dysfunctional. Amperometric biosensor characteristics were strongly affected by monomer and thickness of PPF overcoating related with the diffusion of the substrate (glucose). Considering that the film deposition was performed using microfabrication-compatible organic plasma, our new method for protein architecture has a great potential of enabling high throughput production of bioelectronic devices.

Biosensing Techniques↗

Amperometric phenol biosensor based on laponite clay-chitosan nanocomposite matrix.

A novel strategy to fabricate an amperometric biosensor for phenol determination based on chitosan/laponite nanocomposite matrix was described. The composite film was used to immobilize PPO on the surface of a glassy carbon electrode. Chitosan was utilized to improve the analytical performance of the pure clay-modified bioelectrode. The biosensor exhibited a series of properties: good affinity to its substrate (the apparent Michaelis-Menten constant for the sensor was found to be 0.16 mM), high sensitivity (674 mA M(-1)cm(-2) for catechol) and remarkable long-term stability in storage (it retains 88% of the original activity after 60 days). In addition, optimization of the biosensor construction as well as effects of experimental variables such as pH, operating potential and temperature on the amperometric response of the sensor were discussed.

Adsorption↗

Deep-probe metal-clad waveguide biosensors.

Two types of metal-clad waveguide biosensors, so-called dip-type and peak-type, are analyzed and tested. Their performances are benchmarked against the well-known surface-plasmon resonance biosensor, showing improved probe characteristics for adlayer thicknesses above 150-200 nm. The dip-type metal-clad waveguide sensor is shown to be the best all-round alternative to the surface-plasmon resonance biosensor. Both metal-clad waveguides are tested experimentally for cell detection, showing a detection limit of 8-9 cells/mm2.

Biosensing Techniques↗

Fibre-optic bacterial biosensors and their application for the analysis of bioavailable Hg and As in soils and sediments from Aznalcollar mining area in Spain.

Fibre-optic biosensors for Hg and As were developed by attaching alginate-immobilised recombinant luminescent Hg- and As-sensor bacteria onto optical fibres. The optimised biosensors (consisting of seven layers of fibre-attached bacteria pre-grown till mid-logarithmic growth phase) enabled quantification of environmentally relevant concentrations of the target analytes: 2.6 microg l-1 of Hg(II) and 141 microg l-1 of As(V) or 18 microg l-1 of As(III). The highest viability and sensitivity for target analyte was obtained when fibre tips were stored in CaCl2 solution at -80 degrees C. Applicability of the fibre-optic biosensors in parallel to the respective non-immobilised sensors was assessed on 10 natural soil and sediment samples from Aznalcollar mining area (Spain). On the average 0.2% of the total Hg and 0.87% of the total As proved bioavailable to fibre-attached bacteria. Interestingly, about 20-fold more Hg and 4-fold more As was available to non-immobilised sensor bacteria indicating the importance of direct cell contact (possible only for non-immobilised cells) for enhanced bioavailability of these metals in solid samples.

Arsenic↗

Pathogen detection: a perspective of traditional methods and biosensors.

The detection of pathogenic bacteria is key to the prevention and identification of problems related to health and safety. Legislation is particularly tough in areas such as the food industry, where failure to detect an infection may have terrible consequences. In spite of the real need for obtaining analytical results in the shortest time possible, traditional and standard bacterial detection methods may take up to 7 or 8 days to yield an answer. This is clearly insufficient, and many researchers have recently geared their efforts towards the development of rapid methods. The advent of new technologies, namely biosensors, has brought in new and promising approaches. However, much research and development work is still needed before biosensors become a real and trustworthy alternative. This review not only offers an overview of trends in the area of pathogen detection but it also describes main techniques, traditional methods, and recent developments in the field of pathogen bacteria biosensors.

Animals↗

A third-generation H2O2 biosensor based on horseradish peroxidase-labeled Au nanoparticles self-assembled to hollow porous polymeric nanopheres.

A novel third-generation biosensor for hydrogen peroxide (H2O2) was developed by self-assembling gold nanoparticles to hollow porous thiol-functionalized poly(divinylbenzene-co-acrylic acid) (DVB-co-AA) nanospheres. At first, a cleaned gold electrode was immersed in hollow porous thiol-functionalized poly(DVB-co-AA) nanosphere latex to assemble the nanospheres, then gold nanoparticles were chemisorbed onto the thiol groups of the nanospheres. Finally, horseradish peroxidase (HRP) was immobilized on the surface of the gold nanoparticles. The immobilized horseradish peroxidase exhibited direct electrochemical behavior toward the reduction of hydrogen peroxide. The resulting biosensor showed a wide linear range of 1.0 microM-8.0mM and a detection limit of 0.5 microM estimated at a signal-to-noise ratio of 3. Moreover, the studied biosensor exhibited high sensitivity, good reproducibility, and long-term stability.

Biosensing Techniques↗

Spreeta-based biosensor assays for endocrine disruptors.

The construction and performance of an automated low-cost Spreeta-based prototype biosensor system for the detection of endocrine disrupting chemicals (EDCs) is described. The system consists primarily of a Spreeta miniature liquid sensor incorporated into an aluminum flow cell holder, dedicated to support a Biacore chip frame, in combination with a simple pressurized air-driven fluid system. During the optimization, a monoclonal antibody (MAb)-based immunoassay for the estrogenic compound bisphenol A (BPA) was used as a model. After the optimization two thyroxine transport protein inhibition assays for thyroid endocrine disruptors were implemented. The average noise of the system for 1 min of baseline was 1.1 microRIU (refractive index units) and it could be operated in the range of 18-22 degrees C with a minimum baseline drift (5-10 microRIU/100 min). Optimum signal to noise ratio (S/N R) was obtained using a flow cell height of 100 microm and a flow rate of 180 microl/min. The sensitivity of the Spreeta-based biosensor inhibition assays implemented (50% inhibition concentration (IC50) of 30.2 nM for BPA using MAb12 and 12.3 and 11.6 nM for thyroxine (T4) using thyroxine-binding globulin (TBG) and recombinant transthyretin (rTTR), respectively) was comparable to the sensitivity previously obtained using a Biacore 3000 (IC50 of 39.9 nM for BPA and 8.6 and 13.7 nM, respectively, for T4). The results indicate that the alternative prototype system can be used in combination with ready-to-use biosensor chip surfaces and it is potentially a useful tool for the bioeffect-related screening of EDCs.

Benzhydryl Compounds↗

Bacterial oxygenases: in vivo enzyme biosensors for organic pollutants.

An in vivo enzyme-based biosensor platform was developed that uses specific oxygenase enzymes to detect aromatic compounds in water. Bacteria capable of degrading highly reduced hydrocarbons initiate substrate oxidation using well-characterised oxygenase enzymes, which due to their specificity, stability and high activity can be applied in vivo as biosensor components. Oxygenase enzyme activity was determined in vivo using BD Oxygen Biosensor plates to measure oxygenase-mediated oxygen depletion in the presence of specific aromatic analytes. The BTEX family of compounds (benzene, toluene, ethylbenzene and the three isomers of xylene) were used as model compounds. Detection limits and sensitivity achieved using this approach (microM detection range) was similar to levels achieved with oxygen electrode-based and some recombinant DNA-based approaches. No significant signals were detected with hydrocarbons that were not substrates of the initial oxygenases.

Bacteria, Aerobic↗

Flexible biosensors on spirally rolled micro tube for cardiovascular in vivo monitoring.

New flexible biosensors on a spirally rolled micro tube have been designed, fabricated and characterized for microcatheter-based cardiovascular in vivo monitoring. With this new microfabrication method, sensors, wires and circuits can be fabricated first on the flexible polymer substrate (Kapton film) and then rolled spirally to make micro tubes with different diameters. This approach provides a unique method for mounting multiple sensors on both the inside and outside the tube. So, the new spirally rolled polymer tube flexibly conceives physical, biomedical and physiological microsensors, elevating most problems arisen from wiring and assembling of microsensors in conventional microcatheters. As a demonstration vehicle, we fabricated glucose biosensors on the 25 microm thick Kapton film first, then the film was spirally rolled to make a polymer micro tube with the glucose sensors on the inside wall of the tube. To verify the performance of the spirally rolled glucose biosensor, we characterized it both in a planar unrolled and rolled conditions and compared their performances. The spirally rolled glucose sensors showed good performance in the typical glucose concentration range in human blood from 60 mg/dL to 120 mg/dL with different rolled diameters at different working temperature.

Biosensing Techniques↗