PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “continuous glucose monitoring”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33Linked to original sources

Technological advances in the treatment of diabetes mellitus: better bioengineering begets benefits in glucose measurement, the artificial pancreas, and insulin delivery.

The management of type 1 diabetes is being advanced by innovations in glucose measurement, development of an artificial pancreas, and in alternate routes of insulin delivery. Emerging technologies will allow insulin to be delivered more effectively. In the future, patients with type 1 diabetes will receive insulin in optimal quantities (because of more information about blood glucose values) at optimal times (because of better integration of blood glucose values with appropriate insulin dosages) by way of optimal routes into the body (because of needle-free routes of administration) in order to achieve optimal blood glucose control. Emerging technologies for improved care of patients with type 1 diabetes include: 1. new methods for monitoring glucose, including noninvasive, minimally invasive, continuous, and alternate site measurement technologies; 2. new methods for integrating glucose values and insulin dosages, known as the artificial pancreas; and 3. new routes of insulin administration, including inhaled, oral, buccal, nasal, and transdermal drug delivery systems. These new technologies will facilitate proper treatment of type 1 diabetes and improve the lives of affected patients.

Biomedical Engineering↗

[Use of the endocrine artificial pancreas (GCIIS; Biostator) in heart surgery].

It is well known that deep hypothermia used in open-heart surgery is usually associated with a marked reduction in carbohydrate tolerance, especially dangerous in the diabetic patient, since it might result in severe metabolic complications, namely ketosis and hyperosmolar coma. In order to prevent the occurrence of such complications we treated an insulin-dependent diabetic patient undergoing cardiovascular surgery, with a feed-back insulin infusion operated by an artificial pancreas (GCIIS, Biostator). The Biostator was then used to perform a continuous (minute by minute) blood glucose monitoring in 2 more patients, a type II (non insulin-dependent) diabetic and a non diabetic. Blood samples were drawn sequentially in order to determine plasma free insulin concentration. The glycemic profile observed in the insulin-dependent diabetic under artificial pancreas treatment was similar to that in the non-diabetic. Plasma free insulin levels dropped near to zero during by-pass cooling, returning toward basal level during the rewarming phase. Such results are then discussed by the Authors and given a pathogenetic interpretation.

Blood Glucose↗

New developments in the treatment of type 1 diabetes mellitus.

Treatment of type 1 diabetes mellitus has made tremendous advances within the last decades. With concern to insulin delivery there are two promising new approaches. One is the intrapulmonary insulin delivery which has become feasible by the development of new inhalation devices which provide a sufficient degree of intrapulmonary drug retention. Also oral insulin delivery seems feasible when surface active substances are used to cross the mucosal membrane in the gut. Clinical research has also focussed on coatings for the insulin molecules to solve the problem raised by the proteolytic activity of the digestive system. A very new agent produced by a fungus called Pseudomassaria has been demonstrated to reverse the clinical signs of diabetes mellitus in mice. The compound diffuses through the cell membrane, binds to the inner part of the insulin receptor and activates the insulin typical biological effects. Nowadays a variety of insulin analogs are designed and tested for their clinical use. By shifting the isoelectric point towards to a slightly acidic pH, HOE 901 precipitates at physiologic pH resulting in a constant and peakless insulin delivery. NN 304 is a 14-carbon aliphatic fatty acid acylated analog that binds to serum albumin resulting in a flatter time-action profile than NPH insulin. Also rapid acting insulin analogs are or will be launched in the near future aiming to ensure an improved postprandial glucose regulation. Glucagon-like peptide-1 (GLP-1) improves metabolic control by a variety of effects, e.g. the enhancement of insulin secretion and inhibition of glucagon secretion. Moreover, GLP-1 reduces food and water intake controlled by the brain, and inhibits gastric emptying. A disadvantage of GLP-1 is its very short half-life. Novel derivatives with the beneficial effects of GLP-1 but a better resistance against degradation have been designed. In addition substances have been developed inhibiting GLP-1 degradation or augmenting GLP-1 release from its abundant endogenous pool. Finally, there is a variety of interesting approaches aiming to improve or ease blood glucose self-monitoring. One is the development of subcutaneous catheters for continuous blood glucose control. In another system reverse iontophoresis is used for sampling interstitial fluid which reflects capillary blood glucose levels. Instead of using an electric current, a brandnew system creates micropores in the skin by a laser ablation system. Through these micropores a specific device performs a mild suction to obtain intersitial fluid. Further systems which measure blood glucose by near infrared spectroscopy are still investigated in order to improve their technical function and to reduce their weight. This article intends to give an overview over the new developments in the treatment and management of type-1-diabetes mellitus.

Animals↗

Biosensors for real-time in vivo measurements.

The current status of sensors capable of continuous measurement of analytes in biological media is reviewed. This review containing 173 references deals with devices whose use in single cells, tissue slices, animal models and humans has been demonstrated. In addition to sensors specific for glucose, lactate, glutamate, pyruvate, choline and acetylcholine, insights obtained from monitoring nitric oxide, Na(+), K(+), Ca(2+), and dopamine are presented. Performance criteria for sensor performance are described as is the subject of biosensor calibration. Biocompatibility issues are dealt with in some detail as is the status of continuous blood glucose monitoring in humans.

Biosensing Techniques↗

Heat flux measurements for the fast monitoring of dynamic responses to glucose additions by yeasts that were subjected to different feeding regimes in continuous culture.

Heat measurements have been successfully as an analytical tool for the study of the dynamics of energy metabolism of Saccharomyces cerevisiae and Candida utilis grown in continuous culture under fluctuating substrate supply. A low average dilution rate (D = 0.05 h-1) was maintained either by adding the medium as continuously (dropwise) as possible or (blockwise) by adding the medium at high speed during a short period (D = 0.5 h-1 for 40 s) and not at all during the following period (D = 0.00 h-1 for 360 s). The resulting biological activity was monitored on-line with conventional (O2 and CO2) off-gas analyses, DOT measurements, and heat flux measurements. In C. utilis cultures, the biomass-specific maximum oxygen consumption rate (qO2,max), the biomass yield (Ys,x), and the dynamic responses to a glucose pulse and to a change in feeding regime were not significantly affected by different preceding feeding regimes. In contrast, S. cerevisiae grown in continuous culture with blockwise feed showed a 50% increase in qO2,max and a 25% drop in Ys,x compared to the culture grown with dropwise feed. The dynamic response to a glucose pulse (0.6 g L-1) was slower for the continuous (dropwise) than for the blockwise grown S. cerevisiae. With a second testing method for the dynamic response of the yeasts, the feeding regime was changed. The blockwise fed S. cerevisiae proved to be better "trained" to cope with sudden changes in glucose supply and, therefore, was more "shockproof" toward a change in feeding regime. This clearly points to major differences in the intracellular metabolic flux control between the yeasts. These findings are of relevance for industrial baker's yeast production, where reactor mixing times of one to several minutes are not uncommon. The observed, heat production, together with the dissolved oxygen concentration, appeared to give the fastest response to actual changes in the culture. It is suggested that heat measurements can be a very useful tool to monitor and control the growth of S. cerevisiae in laboratory and industrial fermenter operations.

Biomass↗

Splanchnic retention of intraduodenal and intrajejunal glucose in healthy adults.

Estimates of the spanchnic retention and appearance in the systemic circulation of orally administered glucose vary among laboratories even after recently identified sources of error have been accounted for [Livesey, G., P. D. G. Wilson, J. R. Dainty, J. C. Brown, R. M. Faulks, M. A. Roe, T. A. Newman, J. Eagles, F. A. Mellon, and R. Greenwood. Am. J. Physiol. 275 (Endocrinol. Metab. 38): E717-E728, 1998]. We questioned whether, in healthy humans, D-glucose delivered intraluminally to the midjejunum appeared systemically as extensively as that delivered intraduodenally. Subjects were infused over a period of 90 min with 50 g of glucose in 1 liter of isotonic saline (incorporating 0.5 g D-[13C6]glucose) per 70 kg of body weight. Infusions were via enteral tubes terminating approximately 15 and 100 cm postpylorus. The systemic appearance of glucose was monitored by means of a primed-continuous intravenous infusion of D-[6,6-2H2]glucose. Whereas 98 +/- 2% (n = 7) of the duodenally infused glucose appeared in the systemic circulation, only 35 +/- 9% (n = 7) of midjejunally infused glucose did so, implying that 65 +/- 9% was retained in the splanchnic bed. Either glucose was less efficiently absorbed at the midintestinal site or hepatic glucose sequestration was increased 10-fold, or both. The proximal intestine plays a key role in the delivery of glucose to the systemic circulation, and the distal intestine potentially delivers more glucose to the liver.

Adult↗

The effect of maternal intravenous glucose administration on fetal activity.

OBJECTIVE: The study was designed to objectively evaluate the effect of maternal intravenous glucose infusion on fetal activity. STUDY DESIGN: Twenty-one volunteers at 30.7 +/- 3.0 weeks' gestation were objectively evaluated for fetal activity with a Doppler monitor before and during an intravenous glucose test. Baseline fetal activity monitoring began 10 minutes before a fasting blood glucose level was obtained. A standard 1-hour intravenous glucose tolerance test was then performed, and fetal activity monitoring was continued for the duration of the test. Twenty-one women at 29.8 +/- 3.0 weeks' gestation volunteered to serve as controls and were continuously monitored for fetal activity. The control patients did not receive intravenous glucose. RESULTS: Linear regression analysis revealed an increase in fetal activity in both groups; however, the increase in the glucose infusion group was significantly greater than in the control group. CONCLUSIONS: Maternal glucose infusion causes short-term stimulation of fetal activity; however, some other factor in the monitoring process also stimulates fetal activity.

Blood Glucose↗

Conference on insulin pump therapy in diabetes. Multicenter study of effect on microvascular disease. The pump life. Patient responses and clinical and technological problems.

As part of a randomized, prospective trial in subjects with insulin-dependent diabetes assigned to either continuous subcutaneous insulin infusion (CSII) or to their unchanged conventional insulin treatment (CIT) for 8 mo, patients completed questionnaires dealing with general responses and clinical and technological problems. Although there was no significant difference between treatment groups with respect to the number of patients experiencing severe hypoglycemia (i.e., requiring intravenous glucose or intramuscular glucagon injection), there were nine episodes in six patients during CSII compared with one episode during CIT. Diabetic ketoacidosis occurred significantly more often in the CSII group (nine episodes in eight patients) than in the CIT group (no episodes). A number of CSII-related failures occurred, including omission of premeal bolus, needle dislodgement, pump accidentally turned off, and leakage at the infusion site. At 8 mo, 85% of CSII-treated patients wished to continue indefinitely on the pump, and almost all would continue with self-monitoring of blood glucose even if they stopped CSII.

Canada↗

Impact of an instructional program on nurses' accuracy in capillary blood glucose monitoring.

This experiment examined the accuracy of capillary blood glucose monitoring using the visual glucose oxidase strip (Chemstrip) procedure. Also, the effects of a certification program for nurses on the accuracy of glucose oxidase strip monitoring by registered nurses were analyzed. Seventy nurses and 123 patients participated. Data were collected from nurses' recordings of visual Chemstrip procedure results and from the concurrent laboratory blood glucose determinations for 3 months. The data included 70 Chemstrip recordings and 70 concurrent laboratory blood glucose recordings in the experimental group and 68 Chemstrip and 68 concurrent laboratory glucose recordings in the control group. Data analysis revealed that the accuracy of the nurses' performance of the glucose oxidase strip procedure was inadequate. A certification program did, however, dramatically improve the accuracy of the procedure. Proximity of time between the certification program and the performance of the glucose oxidase strip procedure did not affect accuracy.

Blood Glucose↗

Assessment of in-line near-infrared spectroscopy for continuous monitoring of fermentation processes.

The application of NIR in-line to monitor and control fermentation processes was investigated. Determination of biomass, glucose, and lactic and acetic acids during fermentations of Staphylococcus xylosus ES13 was performed by an interactance fiber optic probe immersed into the culture broth and connected to a NIR instrument. Partial least squares regression (PLSR) calibration models of second derivative NIR spectra in the 700-1800 nm region gave satisfactory predictive models for all parameters of interest: biomass, glucose, and lactic and acetic acids. Batch, repeated batch, and continuous fermentations were monitored and automatically controlled by interfacing the NIR to the bioreactor control unit. The high frequency of data collection permitted an accurate study of the kinetics, supplying lots of data that describe the cultural broth composition and strengthen statistical analysis. Comparison of spectra collected throughout fermentation runs of S. xylosus ES13, Lactobacillus fermentum ES15, and Streptococcus thermophylus ES17 demonstrated the successful extension of a unique calibration model, developed for S. xylosus ES13, to other strains that were differently shaped but growing in the same medium and fermentation conditions. NIR in-line was so versatile as to measure several biochemical parameters of different bacteria by means of slightly adapted models, avoiding a separate calibration for each strain.

Acetic Acid↗

Monitoring of early postnatal glucose homeostasis and cerebral function in newborn infants of diabetic mothers. A pilot study.

The aims of this pilot study were to evaluate a new technique in the monitoring of postnatal glucose homeostasis (microdialysis) and also to study possible associations between early postnatal hypoglycaemia and influences on cerebral function monitoring (CFM) in 12 newborn infants of diabetic mothers. In order to study the postnatal glucose homeostasis, frequent dialysate samples were obtained from a subcutaneous microdialysis catheter for measurements of glucose. In addition, we also received samples of dialysate lactate and glycerol. Dialysate glucose concentrations were correlated to capillary blood glucose levels, measured by a glucose oxidase method. The cerebral function monitor was applied postnatally and a registration was obtained continuously. Capillary blood glucose decreased initially, and seven newborns received intravenous glucose infusions due to glucose concentrations less than 2.2 mmol/l. Dialysate glucose concentrations were, on average, 0.4 mmol/l higher than corresponding concentrations in capillary blood. The correlation coefficient between the two measurements was 0.63 and the coefficient of variation was 19.2%. Dialysate lactate and glycerol levels increased significantly, with peak values 3-4 h postnatally. No significant overall influence of hypoglycaemia was detectable in the CFM tracing. We conclude that a relatively poor correlation was observed between glucose measurements in capillary samples and microdialysis. However, using the microdialysis technique saw indication of marked lipolysis and increased lactate production, which may be of importance for cerebral postnatal adaptation. The mild postnatal hypoglycaemia in infants of diabetic mothers does not seem to give visually detectable influences on CFM.

Adult↗

Effects of QD insulin detemir or neutral protamine Hagedorn on blood glucose control in patients with type I diabetes mellitus using a basal-bolus regimen.

OBJECTIVE: The purpose of this trial was to compare the effects of QD basal insulin replacement using insulin detemir versus neutral protamine Hagedorn (NPH) insulin in basal-bolus therapy in combination with regular human insulin (HI) in patients with type 1 diabetes mellitus (DM). METHODS: This was a 6-month, prospective, randomized, open-label, controlled, parallel-group trial conducted at 92 sites in Europe and Australia. The trial population included men and women with type 1 DM for at least 1 year aged > or = 18 years with glycosylated hemoglobin (HbA(1c)) <== 12% already taking QD basal-bolus treatment with an intermediate- or long-acting insulin and a fast-acting human insulin or insulin analogue as bolus insulin. Patients were randomly assigned (2:1) to 6 months of treatment with insulin detemir or NPH at bedtime in combination with HI with main meals. Main outcome measures were blood glucose control as assessed by HbA(1c), fasting plasma glucose (FPG), 9-point self-monitored blood glucose (SMBG) profiles, 24-hour continuous blood glucose profiles, hypoglycemia, weight gain, and adverse events. RESULTS: Of the 749 patients randomized to treatment, 747 were exposed to trial products and included in the intent-to-treat analysis set. Seven hundred patients completed the trial: 465 (94.7%) in the insulin detemir group and 235 (91.8%) in the NPH group. After 6 months, FPG was lower with insulin detemir than with NPH (-1.16 mmol/L difference; P = 0.001), whereas HbA(1c) did not differ significantly between treatments (-0.12% [95% CI, -0.25 to 0.02]; P = NS). Day-to-day variability in self-measured fasting blood glucose was lower with insulin detemir (SD, 2.82 vs 3.60 mmol/L; P < 0.001). The overall shape of the 9-point SMBG profiles differed significantly between treatments (P = 0.006), with lower glucose levels before breakfast with insulin detemir than with NPH (P < 0.001). There was a 26% reduction in the relative risk of nocturnal hypoglycemia with insulin detemir compared with NPH (P = 0.003). Gain in body weight was significantly lower after 6 months with insulin detemir than with NPH (-0.54 kg difference; P = 0.024). The frequency and type of adverse events were similar between treatment groups. CONCLUSIONS: In this study, QD administration of insulin detemir at bedtime resulted in lower fasting blood glucose levels with less day-to-day variability and less fluctuation from ean blood glucose levels over 24 hours than NPH insulin, combined with an overall reduction in the risk of nocturnal hypoglycemia. These findings suggest that evening administration of insulin detemir may provide an opportunity to further improve fasting blood glucose targets.

Adult↗

Using audit to change practice for routine glucochecks.

Glucochecks are commonly used on admission to hospital to pinpoint patients who may have diabetes. This summary paper describes two clinical audits assessing action following glucocheck results and staff education to improve follow-up. The full audit paper can be accessed at nursingtimes.net.

Blood Glucose Self-Monitoring↗

Bacterial growth inhibition by amniotic fluid. VIII. Evaluation of a radiometric bioassay for rapid, in vitro demonstration of phosphate-sensitive bacterial growth inhibitor in amniotic fluid.

A radiometric bioassay based on the continuous monitoring of 14CO2 released from labeled glucose in the presence of amniotic fluid or amniotic fluid with added phosphate has been employed to detect the presence of a phosphate-sensitive bacterial inhibitor in amniotic fluid near term. The time required for detection of the inhibitory activity is approximately 12 hours, in contrast to approximately 36 hours required for a previously reported technique. Application of this radiometric bioassay to demonstrate bacterial growth inhibition by amniotic fluid and physicochemical properties of the inhibitory activity yielded results comparable to those obtained with the older method of plate counts of viable bacteria. By the new technique it was possible to demonstrate that the inhibitory activity was phosephate sensitive, heat stable, inactivated by metal chelation, removed by bentonite, and present in a low-molecular-weight fraction of amniotic fluid.

Amniotic Fluid↗

Exogenous ATP and carbohydrate metabolism in the rat liver.

The present study analyzed the actions of exogenous ATP on liver carbohydrate metabolism by using both isolated perfused rat livers and hepatocytes as model systems. The metabolic parameters measured in the perfused livers were glucose production, lactate production, oxygen consumption, and K+ movement. All parameters were monitored continuously during the perfusions in order to assess transient effects. ATP increased both glucose and lactate production in the isolated rat liver when perfused with either constant pressure or constant flow. ATP increased oxygen consumption in the perfused liver at a low concentration (10 microM) but was inhibitory at high concentrations (40 and 160 microM). ATP also increased K+ efflux in the isolated perfused liver. ATP did not alter basal glucose production in isolated hepatocytes; however, it did inhibit glucagon-stimulated glucose output by hepatocytes. ATP inhibited lactate production in the isolated hepatocytes. Extracellular ATP has the potential to modify basal as well as hormonal modulation of hepatic carbohydrate metabolism during shock.

Adenine Nucleotides↗

Superior efficacy of pulsatile versus continuous hormone exposure on hepatic glucose production in vitro.

To elucidate the potency of continuous vs. intermittent exposure to hormonal stimuli, hepatic glucose production of isolated perfused rat livers was monitored in response to glucagon and insulin infusion. Using a nonrecirculating perfusion system, continuous exposure to glucagon (35 pM) induced a rise in hepatic glucose production from basal 0.33 +/- 0.03 mmol/(96 min X 100 g BW) to 0.65 +/- 0.02 mmol/(96 min X 100 g BW), while intermittent exposure (3 min on/off intervals; total dose 50%) to the same glucagon concentration elicited an almost identical rise in hepatic glucose production to 0.59 +/- 0.12 mmol/(96 in X 100 g BW). Insulin (100 mU/liter) given continuously and intermittently (3 min on/off intervals) inhibited glucagon-stimulated (70 pM) hepatic glucose production to the same extent, i.e. by 37.4% and 41.1%, respectively. Doubling the off period to 6 min and thereby reducing the total hormone dose to 33% did not diminish insulin's suppressive effect on glucagon-stimulated hepatic glucose release (34.6%). When the latter infusion protocol was applied with insulin at 300 mU/liter, hepatic glucose production during the first 40 min of glucagon infusion was more restrained (P less than 0.01) than during continuous delivery of 100 mU/liter, although the same amount of insulin was infused per period of time. In parallel, glucagon-stimulated cAMP release was similarly suppressed by insulin in all experiments. From this we conclude that the effect on hepatic glucose production of pulsatile administration of glucagon as well as of insulin, depending on the applied time interval of hormone exposure, is equipotent or even superior to the respective hormones' continuous infusion even if the hormone load is significantly reduced.

Animals↗

Hormonal and metabolic responses of fetal lamb during cardiopulmonary bypass.

OBJECTIVE: To study the hormonal and metabolic responses of fetal lamb during cardiopulmonary bypass. METHODS: Six pregnant ewes underwent fetal cardiopulmonary bypasses with artificial oxygenators and roller pumps for 30 minutes, which maintained the blood gas value at the fetal physiological level. The fetal blood pressure, heart rate, pH value and blood lactate levels were monitored. The levels of catecholamine, cortisol and insulin were measured pre-bypass and then again 30 minutes later. The blood glucose and free fatty acid levels were monitored continuously during the bypass. Fetal hepatic PAS staining was also carried out. RESULTS: There were no changes before and during the bypass in fetal blood pressure, heart rate and blood gas. However, pH values decreased and blood lactate levels increased (P < 0.05). The fetal catecholamine and cortisol levels increased significantly (P < 0.01), while the levels of insulin did not change. The blood glucose and free fatty acid levels increased at the beginning of the bypass (P < 0.01), and then gradually slowed down during the bypass. The fetal hepatic PAS staining showed that hepatic glycogen was consumed in large amounts. After 30 minutes of bypass, the fetal lamb would not survive more than 1 hour. CONCLUSION: The fetal lamb has a strong negative reaction to cardiopulmonary bypass.

Animals↗