PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “systems drift”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33Linked to original sources

The variance of sample heterozygosity.

The variance of sample heterozygosity, averaged over several loci, is studied in a variety of situations. The variance depends on the sampling implicit in the mating system as well as on that explicit in the loci scored and individuals sampled. There are also effects of allelic distributions over loci and of linkage or linkage disequilibrium between pairs of loci. Results are obtained for populations in drift and mutation balance, for infinite populations undergoing mixed self and random mating, and for finite monoecious populations with or without selfing. For unlinked loci in drift/mutation balance, variances appear to be lessened more by increasing the number of loci scored than by increasing the number of individuals sampled. For infinite populations under the mixed self and random mating system, however, the reverse is true. Methods for estimating the variance of sample heterozygosity are discussed, with attention being paid to unbalanced data where not all loci are scored in all individuals.

Alleles↗

Determinants of disability in illnesses related to agricultural use of organophosphates (OPs) in California.

Organophosphate (OP)-related illness data reported to the Worker Health and Safety Branch (WH&S) at the California Department of Food and Agriculture (CDFA, now Cal-EPA) in the years 1984-1988 were examined. Eight hundred and seventy-eight cases with systemic illness and 199 cases of skin disease or eye injury were identified. Systemic cases were divided into two outcome groups: (1) "severe," disability and/or hospitalization days (n = 361), and (2) "mild," no disability or hospitalization days (n = 372). For the remainder (n = 145) or 16.5% of the cases, illness severity could not be determined. Using multiple logistic regression, independent predictors of "severe" illness were identified among the systemic cases. Workers coming in contact with OP residue on commodities or in the field ("exposed to residue" or ER) (OR = 4.6, 95% CI = 3.03-7.07) and mixer/loaders/applicators (MLA) (OR = 4.1, 95% CI = 2.72-6.07) were at significantly increased risk of severe illness when compared with cases exposed to OP application drift. Cases with a Spanish surname were also at increased risk of severe illness (OR = 1.8, 95% CI = 1.25-2.73). Increased numbers of OPs per exposure were also associated with severe illness (p < 0.001). Among cases who were exposed to only one OP, severe systemic cases were more likely than mild systemic cases to be associated with exposure to diethyl than dimethyl compounds (OR = 1.6, 95% CI = 1.09-2.38). Severe systemic cases were also more likely than severe skin/eye cases to be associated with exposure to OPs with high toxicity (OR = 5.5, 95% CI = 2.42-12.60) and with exposure to diethyl groups (OR = 4.8, 95% CI = 1.90-12.00). These findings suggest that reducing exposure to OP residues, to OPs with diethyl groups, and to multiple OPs, and exposure during mixer/loader/applicator activities would reduce the risk of OP-related illness.

Adolescent↗

The role of social support systems in adolescent cancer amputees.

Amputation is often a component in the treatment of bone tumors such as osteogenic sarcoma, which is most prevalent in the adolescent age group. Adaptation to cancer and loss of a limb requires a significant multidimensional effort. To examine the role of social support systems, 27 adolescents who had undergone amputations for cancer were interviewed. Inquiries were made regarding patients' perceived social support providers and the impact of amputation upon their lives and independence. Parents, especially mothers, were perceived as realistic and most helpful at the time of surgery (80%), followed by professional hospital staff (59.3%), and siblings (59.3%). Friends of patients were less helpful, as many reported their friends felt sorry for them (65.4%), avoided them (33.3%), or drifted away (40%). Only 7.4% of the patients had a clear preference to be associated with other amputees. This study details other preferences and difficulties encountered by the adolescent amputees and the role of support systems in their adaptation to their disease and amputation.

Adolescent↗

Movement speed effects on limb position drift.

Previous research has shown that even when limb position drifts considerably during continuous blind performance, the topological and metrical properties of generated hand paths remain remarkably invariant. We tested two possible accounts of this intriguing effect. According to one hypothesis, position drift is due to degradation of limb-position information. This hypothesis predicted that drift of static hand positions at movement reversals should not depend on movement speed. According to the other hypothesis, position drift is due to degradation of movement information. This hypothesis predicted that drift of static hand positions at movement reversals should vary with movement speed. We tested these two hypotheses by varying the required movement speed when normal human adults performed back-and-forth manual positioning movements in the absence of visual feedback. Movement distance and direction were well preserved even though hand positions between movements drifted considerably. In accord with the movement error hypothesis, but not in accord with the position hypothesis, the rate at which hand positions drifted depended on movement speed. The data are consistent with the idea that hand position, which defines the origin of the trajectory control coordinate system, and movement trajectory are controlled by distinct neural mechanisms.

Adult↗

Evaluation of the in-situ aerobic cometabolism of chlorinated ethenes by toluene-utilizing microorganisms using push-pull tests.

A series of transport, biostimulation, and activity push-pull tests were performed under induced and natural gradient conditions in a trichloroethene (TCE) and cis-dichloroethene (c-DCE) contaminated aquifer. Transport tests demonstrated the feasibility of injecting and recovering complex solute mixtures from the aquifer. During the biostimulation tests, decreases in toluene concentration and the production of o-cresol as an intermediate oxidation product indicated the presence of toluene-utilizing microorganisms. Activity tests demonstrated that the stimulated microbial community had the ability to transform injected c-DCE and trans-dichloroethene (t-DCE) at similar zero-order rates. Injected isobutene was oxidized to isobutene oxide, which indicated that a toluene ortho-monooxygenase enzyme system was likely responsible for the observed c-DCE and t-DCE transformations. c-DCE zero-order transformation rates in drift push-pull tests were similar to those obtained from traditional push-pull tests (about 0.1 microM/h). Analysis of drift test data using first-order kinetic analysis resulted in similar conclusions as those obtained using zero-order kinetic analyses. When 1-butyne, an inhibitor of toluene ortho-monooxygenase, was added to injected test solutions, the oxidation of toluene, and the transformation of isobutene, c-DCE, and t-DCE were inhibited. The results illustrate how a series of push-pull tests can be used in combination to detect, quantify and confirm in-situ cometabolic microbial transformations.

Aerobiosis↗

Influence of pinning effects on the electrochemical formation of silver patterns in agarose-containing sols and gels.

The formation of silver patterns via electrolysis from aqueous silver sulfate + x% w/v agarose sol and gel media, with and without supporting electrolyte, in a quasi-two-dimensional (2D) cylindrical cell at room temperature, is utilized as a reference system to investigate the complexity of pinning effects. From pattern morphology and electrochemical data, both delocalized and localized pinning in the bulk dominate the drift of the growth front, depending on the concentration of agarose in the heterogeneous media. Delocalized pinning results from mobile, small agarose aggregates at the growth front and from their accumulation by the front drift. For gels, localized pinning comes from their own percolated structure. A depinning/pinning transition is observed in going from sols to gels. The relative contribution of diffusion and advection in mass-transport-controlled silver electrodeposition depends on the plating bath composition. On the other hand, silver ion attachment to the cathode appears to be interfered with by some screening caused by weakly adsorbed, mobile agarose aggregates at the metal surface without slowing down the rate of the electron-transfer step at the cathode. Their relative contribution of a delocalized, localized pinning and screening effect to a great extent determines the morphology and transition in the growth mode of silver patterns in both media. The analysis of charge and current transients and the corresponding silver pattern morphologies for open and dense radial patterns is made. Results are qualitatively simulated with a novel, rather simple cellular automaton algorithm.

Electrochemistry↗

Dendritic synchrony and transient dynamics in a coupled oscillator model of the dopaminergic neuron.

Transient increases in spontaneous firing rate of mesencephalic dopaminergic neurons have been suggested to act as a reward prediction error signal. A mechanism previously proposed involves subthreshold calcium-dependent oscillations in all parts of the neuron. In that mechanism, the natural frequency of oscillation varies with diameter of cell processes, so there is a wide variation of natural frequencies on the cell, but strong voltage coupling enforces a single frequency of oscillation under resting conditions. In previous work, mathematical analysis of a simpler system of oscillators showed that the chain of oscillators could produce transient dynamics in which the frequency of the coupled system increased temporarily, as seen in a biophysical model of the dopaminergic neuron. The transient dynamics was shown to be consequence of a slow drift along an invariant subset of phase space, with rate of drift given by a Lyapunov function. In this paper, we show that the same mathematical structure exists for the full biophysical model, giving physiological meaning to the slow drift and the Lyapunov function, which is shown to describe differences in intracellular calcium concentration in different parts of the cell. The duration of transients was long, being comparable to the time constant of calcium disposition. These results indicate that brief changes in input to the dopaminergic neuron can produce long lasting firing rate transients whose form is determined by intrinsic cell properties.

Animals↗

Re-engineering trust: the adoption and adaption of four models for external quality assurance of health care services in western European health care systems.

Accreditation, ISO, EFQLM and visitatie are, in essence, control mechanisms in health care systems. An analysis is provided of the way the four models have been adopted and adapted in European health care systems over the past decade. After a short discussion of the major reforms in the European health care systems in the direction of regulated markets, deregulation and decentralization, the features of the four models are highlighted and it is explained how each of them can help to fill the 'accountability gap' between health care providers on the one hand and patients, financiers and governments on the other. The quality system perspective of ISO, the quality management development perspective of EFQM, the health care organization perspective of accreditation and the professional perspective of visitatie can each be appropriate given the balance of power between parties in the health care system and the focus and scope of accountability. Although a general convergence between the four models can be observed, actual convergence will depend on their adoption in specific health system contexts. Potential pitfalls for further convergence are the differences in distribution of responsibilities for quality of care among the various European countries, the drift away from clinical decision making, bureaucratic tendencies and too much focus on efficiency and patient empowerment compared with attention to medical effectiveness.

Accreditation↗

An improved technique for the rapid continuous measurement of whole blood glucose, suitable for clinical application in an artificial endocrine pancreas.

An improved bedside technique for the continuous monitoring of glycemia is described. A linear relationship results between whole blood glucose concentration and plasma glucose levels, and allows the calibration of the system in terms of plasma glucose levels. In operation venous blood is withdrawn at a steady rate using a double-lumen catheter and directed to a continuous-flow laboratory analyzer, where glucose analysis is carried out using a modified glucose oxidase-peroxidase methodology. The improvements in this technique include: i) a reduction in the delay of the analyzer to 90 s, making it suitable for application in a system for blood glucose regulation, ii) a minimal blood requirement of 3 ml/h, permitting long-term monitoring, iii) elimination of the need for systemic anticoagulation, iv) an excellent correlation (r = 0.993) between the measured whole blood glucose and the actual plasma glucose concentration, v) an average baseline drift of +0.5 mg%/h, vi) a sensitivity loss of less than 0.1%/h, and vii) a reasonable operating cost. This technique was implemented as part of a clinical apparatus known as an artificial endocrine pancreas which has been reliably applied in clinical and animal studies.

Adult↗

Study on the stability of the calibration and normalization in PET and the influence of drifts on the accuracy of quantification.

With regard to the quality control of quantification in positron emission tomography some characteristics were examined, to develop a simple method for frequent monitoring. The stability and uniformity of the detector count rate was checked by plotting the RMS deviation of the non normalized count rate and the standard deviation of the normalized count rate, each normalized to its value after the calibration or normalization respectively. Switching off a single detector did not impair the image quality, but the normalized image pixel counts were reduced by 2%-3% when a detector block was switched off. Thus in case of need, a weak detector can still be used to perform a scan. A reduced count rate capability at specific activities above 5 x 10(4) Bq/ml (approximately 1.5 x 10(5) corrected true system counts/s or approximately 1.5 x 10(4)/s for a plane) was found compared to the maximum usable activity of 8 x 10(4) Bq/ml obtained 1 year earlier, indicating a drift in the count loss corrections. A variation of the room temperature changes the temperature distribution inside the gantry by 5% per degree C and the drift of the sensitivity (normalized image pixel counts) is 2% per degree C.

Temperature↗

[The genes of the Pascuense population].

An analysis of the interaction of evolutionary factors such as migration, mutation, selection random drift, and consanguinity upon the genome of Easter islanders is attempted. As many primitive populations, the Easter islanders genome has at least 2/3 of genetic loci in an isogenic state. The HLA system is reduced; other polymorphisms present high genic frequencies differentiating Easter islanders from other Andean and european populations. They are more similar to polynesians, with whom they share language and culture. Migration has been the main factor affecting the Easter islanders genome, leading to a ten fold increase in population and a 60% caucasian admixture. A linkage disequilibrium of the HLA9, w10 haplotype exists. In XIX century generations consanguinity was very low (alpha coefficient 7 x 10(-5) which may be explained by the exogamic tradition of the population; this acted as a factor opposed to random drift. A recent decrease in infant mortality rate leads to a relaxation of natural selection and contributes to hybridization of the population.

Chile↗

Establishing and maintaining performance claims. A manufacturer's viewpoint.

Performance claims are the vehicle by which a manufacturer communicates the analytic capabilities of its methods to laboratory users and to regulatory agencies. Claims describe the expected performance of an analytic system. To be useful, claims must be meaningful, achievable, and verifiable. To ensure consistent interpretation, they must be stated in clear, unambiguous terms. There are no specific guidelines for stating claims. Consequently, comparing the performance of one system to another is difficult. Claims fall into three categories: clinical utility, analytical performance, and boundary conditions. This article focuses on the three basic analytical performance characteristics, precision, accuracy, and specificity, and describes how they are established, validated, maintained, and monitored by manufacturers and how they can be verified by end users. Precision claims describe the inherent variability of the system. They differ in the components of variance included, ranging from the short-term variables within a single run to the long-term variables experienced over time, such as lot changes, calibrations, instrument drift, and environmental fluctuations. Precision may be stated either as typical user experience or as the minimum performance expected. Accuracy claims describe the degree to which the results will approximate the true values. They are more difficult to establish and verify, given the lack of objective standards for many analytes. For this reason, few manufacturers make true accuracy claims, relying instead on comparisons with other marketed methods. A notable exception is cholesterol, for which a model reference system has been established to help laboratories ensure accuracy. External proficiency testing is handicapped by matrix effects from imperfect survey fluids. Specificity claims describe the method's freedom from interference and cross-reactivity. They are based on screening tests by the manufacturer, augmented by feedback from users. There are no agreed-on criteria for what constitutes clinically significant interference, and no consistent approach for disclosing interference information. The National Committee for Clinical Laboratory Standards, Villanova, Pa, is beginning to develop guidelines to promote greater consistency in performance claim statements.

Calibration↗

The management of children admitted to child welfare services in Ontario: a review and discussion of current problems and practices.

Children coming into the care of the Ontario Child Welfare System are generally older and more seriously disturbed. Foster parents and Children's Aid Societies have had to change in order to meet the needs of these troubled children. While the efficacy of foster care continues to be debated, there are ways to improve in-care management including: ways of preventing drift, appropriate assessment of parenting capacity, minimizing emergency placements, and more energetic and focused casework which deals appropriately both with the deficits and distortions internalized in the child as a result of previous damage and with the ongoing interactional stresses operative within the foster family system. The advantages of planned over emergency placements are discussed. The child separated from natural parents will mourn. Foster parents' and workers' roles in assisting the work of mourning in foster children are discussed. Soon after admission to care, the practicality of restoration to the natural family must be assessed, and management should then aim towards restoration or towards freeing the child for adoption or planned permanent foster care, should that represent the least detrimental available alternative. The family court system as presently constituted frequently and unnecessarily undermines rather than protects the adjustment and development of vulnerable children. Mechanisms by which this occurs and some proposed solutions are suggested. The paper concludes by suggesting that the traditional low priority given to child welfare services by governments is unlikely to be altered unless mental health professionals succeed in eliciting considerably more community support for adequate social services than is currently available.

Adoption↗

A pulse of endosulfan-contaminated sediment affects macroinvertebrates in artificial streams.

The toxicity of the organochlorine pesticide endosulfan to macroinvertebrate communities was tested using a system of 24 artificial streams. Macroinvertebrate communities in the streams were exposed to a range of endosulfan concentrations for a 12-h period and then monitored for 96 h. Endosulfan was prebound to fine river sediment and applied to the streams as a contaminated sediment slurry. This did not cause changes in the structure of benthic communities; however, significant changes (P<0.05) in the abundance of several macroinvertebrate taxa in drift were detected in the streams receiving the highest (6.14 microg/L) dose. Increased drift may have implications for recolonization processes in lowland rivers, and, as such, pulses of contaminated sediment are likely to result in significant effects on macroinvertebrate populations and communities. This study highlights the utility of artificial stream systems for detecting sublethal effects and the need for population and community-level endpoints to be included in such studies.

Animals↗

Antigenic drift in visna: virus variation during long-term infection of Icelandic sheep.

A group of 20 Icelandic sheep were infected intracerebrally with visna virus strain 1514, and 209 virus isolates were obtained from the blood, cerebrospinal fluid, and central nervous system (CNS) over a period of 7 years, during which eight animals developed clinical signs of visna necessitating sacrifice. (i) Using type-specific antisera, it was found that 12 (16%) of 76 isolates tested escaped neutralization. These 12 variant viruses were distributed randomly among animals and over time, and did not replace the infecting strain even though all sheep developed homotypic antibody within 3 months of infection. The one exception was sheep no. 1557 (an animal without clinical visna), where the last six isolates were variants. (ii) A total of 35 blood and CNS isolates from seven of these sheep (including five with clinical visna) were tested against serial samples of their own sera. Autologous antisera neutralized all isolates tested with the exception of isolates from sheep 1557. None of the isolates obtained at sacrifice from the five sheep with clinical visna escaped neutralization with autologous antisera. These data suggest that although variant viruses are encountered at considerable frequency during long-term infection of Icelandic sheep, the variants usually do not replace the infecting strain. Antigenic drift does not appear to be essential for virus persistence or for the development of clinically evident CNS lesions.

Animals↗

Calibration of ion-selective microelectrodes: flow-system and analysis program for the IBM PC.

A menu-driven program--written in C and Assembly language--has been developed for use with an IBM PC or compatible computer for calibration of ion-selective microelectrodes. Available features include (i) user-logical commands, (ii) rapid, accurate construction and display of calibration curves (fitted by least squares non-linear regression), (iii) analysis of data (stored either on- or off-line), with correction for drift and conversion from voltage or length to ion concentration or activity, (iv) calculation of selectivity coefficients, (v) optional storage and use of activity coefficients, and (vi) output of data, calculations and graphics to printer and plotter. A simple chamber and valve-activated flow-system for rapid change of solutions with either manual selection or computer control is also described.

Microelectrodes↗

Intra-arterial blood gas monitoring system: more accurate values can be obtained.

OBJECTIVE: To compare values measured by a continuous intra-arterial blood gas monitoring system with those measured by conventional blood gas analyzer for the assessment of the clinical performance of a new device for measurement of PaO2, PaCO2, and arterial pH. METHODS: Forty-six patients undergoing cardiopulmonary bypass were enrolled in this study. All patients had a continuous intra-arterial sensor (PB 3300) placed into the radial artery through a 20-gauge catheter. A total of 319 arterial blood gas and pH values were obtained for comparison with a conventional blood gas analyzer. The measurements were performed every 12 hrs after the initial in vitro calibration of the sensor for each patient. RESULTS: Measurements were made over a range of 12 to 192 hrs. The overall bias and precision determined by the two methods were 4.5 and 17.1 mmHg for PaO2; 4.5 and 6.2 mmHg for PaCO2; and 0.009 and 0.035 for pH, respectively. For the range of PO2 less than 150 mmHg, the bias and precision improved to 4.2 and 9.5 mmHg. The sensor-derived PCO2 value, PCO2 (IABG), increased significantly more than the conventional blood gas analysis value, PCO2(ABG), even within 72 hrs (2.8 and 4.1 mmHg). The relationship between the two measurements can be described as: PCO2(IABG)/PCO2(ABG) = 1 + 0.0026.t where t is the time period of use (in hours). By correcting the PCO2(IABG) value using this formula, the overall bias and precision of the values measured by two methods decreases to -0.4 and 3.6 mmHg. CONCLUSIONS: The PO2 and pH values derived from an intra-arterial blood gas monitoring system agreed well with the values measured by a conventional blood gas analyzer. However, the PCO2 value must be corrected due to an increase of drift, especially with extended use for more than 72 hours.

Blood Gas Analysis↗