PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Angiography, Digital Subtraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34Linked to original sources

Intravenous digital subtraction angiography in the pre-operative evaluation of coarctation of the thoracic aorta.

Many authors have previously advocated the use of intravenous digital subtraction angiography (IV-DSA) in the pre-operative evaluation of coarctation of aorta with excellent results and good surgical correlation. We have studied 20 patients with coarctation of aorta by IV-DSA and compared the angiographic findings with those seen at surgery in nine patients. The IV-DSA examinations were performed by utilizing small-volume (25 ml), bolus injections of an ionic, iodinated water soluble contrast medium delivered in the mid-right atrium. Good quality diagnostic arterial images were obtained in 14 patients (70 per cent). Associated cardiac decompensation and inability to profile the coarct segment due to overlap by surrounding dilated blood vessels were responsible for the unsuccessful examinations. Whereas most IV-DSA findings were confirmed at surgery, the calibre and length of the coarct segment at IV-DSA were found to be unreliable predictors of the actual severity of the coarctation. The IV-DSA images failed to detect a localized diaphragm at the coarct site in two patients. Even though IV-DSA is useful for the diagnosis of aortic coarctation, the surgeon must be aware of its pitfalls in assessing the calibre and length of the coarct segment.

Adolescent↗

Abdominal aortic aneurysm morphology in candidates for endovascular repair evaluated with spiral computed tomography and digital subtraction angiography.

PURPOSE: To analyze the morphology of abdominal aortic aneurysms (AAAs) and to study the usefulness of spiral computed tomography (CT) versus digital subtraction angiography (DSA) in the evaluation of patients for endovascular repair. METHODS: Of 133 AAA patients (120 men, mean age 67 years, range 52 to 84) evaluated preoperatively with CT imaging, 77 endograft candidates (68 men) were also assessed with intra-arterial DSA. Arterial parameters were measured on axial CT scans and angiographic films for comparison. RESULTS: Mean maximum AAA diameter was 58 +/- 11 mm (range 39 to 95). Aneurysmal neck diameter was consistently smaller on DSA than on CT (20.7 +/- 3.6 mm versus 23.0 +/ 3.5 mm, p < 0.0001). The distance from the most distal renal artery to the aortic bifurcation was longer on angiography than on CT (mean difference 10.0 mm, p < 0.0001). There was a positive correlation between the maximum AAA diameter and the AAA length (r = 0.49, p < 0.0001) and an inverse relationship between the neck length and the neck diameter (r = -0.36, p < 0.0001). No correlation was found between the maximum AAA diameter and maximum iliac diameter, angulation, or length. CONCLUSIONS: AAA anatomy varies widely and independently of the aneurysm size. Therefore, the maximum size of the aneurysm is a poor predictor of whether or not an aneurysm is suitable for endovascular repair. The discrepancy between angiographic and axial CT measurements suggests that neither alone is sufficient as a preoperative imaging technique when evaluating a patient for an endovascular graft procedure.

Aged↗

The measurement of internal carotid artery stenosis: comparison of duplex with digital subtraction angiography.

OBJECTIVES: To compare the subjective (eyeballed) method for measuring internal carotid artery (ICA) stenosis by non-selective intra-arterial digital subtraction angiography (IA-DSA) with objective and duplex methods. DESIGN: Retrospective study. MATERIALS AND METHODS: Fifty-three consecutive patients underwent IA-DSA prior to carotid endarterectomy providing 103 carotid angiograms. Objective assessment of ICA stenosis was by the North American Symptomatic Carotid Endarteectomy Trial (NASCET) criterion and the Carotid Stenosis Index (CSI). Duplex estimation of stenosis was derived from peak systolic and diastolic velocities in the ICA and common carotid artery (CCA). RESULTS: The coefficient of repeatability was poorest for NASCET stenosis estimates (40%), whilst the improved values for CSI (20%) were consistent with the lower variability recorded for measuring the CCA diameter. Correlation and agreement levels between subjective (r = 0.80, -41% to +33%) or objective assessments and duplex (NASCET: r = 0.76; -52 to +28%; CSI: r = 0.72; -27 to +39%) showed similar values. CONCLUSIONS: We conclude that the inter-observer variability for assessing angiograms obtained by arch injection is considerable and precludes high agreement when IA-DSA is compared with other methods. As the agreement of duplex ultrasound with IA-DSA is similar to the agreement between DSA methods, duplex can be offered as the first stage assessment of ICA stenosis, with the proviso that the duplex assessment is performed consistently by an experienced operator.

Aged↗

New noninvasive assessment of regional left ventricular function by digital subtraction angiography without the use of contrast medium.

We have developed a new noninvasive method to evaluate regional left ventricular (LV) function by digital subtraction angiography (DSA) without the use of contrast medium. DSA images of the left ventricle with and without contrast medium were obtained from 35 patients with anterior myocardial infarction (MI) and from 35 control subjects. Using an image-processing computer, regional LV time-density curves were constructed for one cardiac cycle. Regional LV time-density curves obtained from DSA without the use of contrast medium presented a pattern similar to those from intravenous DSA. The amplitude of regional LV time-density curves in patients with MI decreased along with increasing severity of regional wall motion abnormality assessed by conventional left ventriculography. In attempting semi-quantitative evaluation by DSA without the use of contrast medium, the regional wall motion index (RWI) in the 6 segments of the left ventricle was calculated by normalizing segmental density changes to the maximal segmental density changes. When compared with control subjects, patients with MI have significantly lower RWIs in the anterolateral and apical regions. RWI showed a good correlation with the regional ejection fraction (REF) obtained from intravenous contrast DSA (r = 0.83). RWI decreased with increasing severity of regional wall motion abnormality by qualitative analysis in conventional left ventriculography, being consistent with REF. The diagnostic accuracy of RWI therefore seemed to be comparable to that of REF derived from intravenous contrast DSA. These results indicate that computerized analysis of DSA without the use of contrast medium is a valuable noninvasive method for semi-quantitative assessment of regional LV function.

Adult↗

Azotemia: gadopentetate dimeglumine as contrast agent at digital subtraction angiography.

In an azotemic patient with suspected renal artery stenosis, undiluted gadopentetate dimeglumine was administered in an aortic bolus to provide contrast at digital subtraction angiography of the aorta and renal arteries. The contrast material (5 mmol/mL) was power injected (rate, 15 mL/sec; total dose, 30 mL). Selective renal arteriography was also performed with 5 mL of undiluted gadopentetate dimeglumine hand injected into each renal artery (total dose, 40 mL). The patient tolerated the procedure without complication or worsening of renal function, and diagnostic angiographic images were obtained.

Aged↗

Three-dimensional rotation venography using the digital subtraction angiography unit with a flat-panel detector: usefulness for the transtemporal/transtentorial approaches.

We obtained the venograms using the two-dimensional digital subtraction angiography (2D DSA) images and three dimensional rotation venography (3D RV) images and investigated the potential usefulness of the 3D RV compared with venograms of 2D DSA using the newly developed three-dimensional rotation angiography unit with a flat-panel detector (FPD). This study included 26 sides (11 left, 15 right) in 20 cases (4 males and 16 females) who underwent radiographic examination for management of intracranial tumors and vascular diseases between May 2003 and December 2003. Each patient underwent diagnostic angiography performed on a DSA unit with a FPD. In all patients, the 2D DSA images, including anteroposterior view and lateral view of the carotid artery, were obtained in two stereoscopic views. The 3D RV was used to produce volume-rendered images. Two neuroradiologists investigated the venous configuration of 3D RV compared with that of 2D DSA about the relationship of the venous drainage system on the temporal lobe according to Guppy et al.'s classification. Twenty-four sides of the 26 sides enabled the precious visualization on 3D RV images. In investigation of 2D DSA, 9 sides (37.5%) were classified into type A, 13 (54.2%) into type B, two (8.3%) into type C, and no sides into types D, E, and F. In investigation of 3D RV images, 10 sides (41.7%) were classified into type A, 9 (37.5%) into type B, 1 (4.2%) into type C, 2 (8.3%) into type E, and 2 (8.3%) into type F. Seven of 24 sides demonstrated discrepancy in results between 2D DSA and 3D RV. The 3D RV could be performed by setting the adequate delay in between the injection of the contrast material and starting time of third rotation to acquire the opacified images. In Guppy et al.'s classification, the 3D RV images could demonstrate the precious venous drainage including the venous lakes with use of multiple views and variable reconstruction compared with 2D DSA. Our DSA system with FPD could provide good 3D RV images. These images are very useful for the skull-base surgery because we can understand the three-dimensional vascular anatomy preoperatively.

Adult↗

[Vascular pedicled pelvic bone span. Value of digital subtraction angiography in pre- and postoperative diagnosis].

The pedicled pelvic bone graft is a new operative technique for the treatment femoral head necrosis. 29 femoral head necroses were examined by i.a. DSA before a pedicled pelvic bone graft was implanted. 11 pedicled pelvic bone grafts were investigated postoperatively. The pre- and postoperative findings are presented. I. a. DSA is a valuable method for the evaluation of the vascularisation of the femoral head before and after surgery.

Adult↗

Thoracic aortic rupture: advantages of intraarterial digital subtraction angiography.

Sixty-one consecutive patients with blunt thoracic trauma underwent intraarterial digital subtraction angiography (IA-DSA) of the thoracic aorta because of obscuration of the aortic knob or mediastinal widening on chest radiographs. Ten of these patients had aortic ruptures diagnosed by IA-DSA. Digital subtraction aortography proved 100% accurate as indicated by results of surgery, conventional arteriography, serial chest radiography, and clinical follow-up. The method was 50% faster compared with conventional aortography and saved significantly on film costs. The potential for use of smaller caliber catheters and a decrease in contrast requirements also make this method safer than conventional arteriography. We recommend IA-DSA as the procedure of choice when emergency aortography is warranted.

Accidents, Traffic↗

[An invariant approach for image registration in digital subtraction angiography].

In modern medicine, DSA is a powerful technique in visualizations of blood vessels of X-ray images. In DSA, the most important way for motion correction is image registration. In this paper, a new approach to the registration is used. It is based on means of template matching according to a combined invariants-based similarity measure and TPS image warping. Furthermore it has been improved through practice. and tests have proved to remove the motion artifacts effectively and rapidly.

Algorithms↗

Microdroplet tracking using biplane digital subtraction angiography for cerebral arteriovenous malformation blood flow path and velocity determinations.

High-speed biplane angiography is used to determine the path and velocity of microdroplets of contrast material in three dimensions. By allowing more accurate determination of detailed blood flow in feeding vessels and draining veins of cerebral arteriovenous malformations than available with standard angiography, the new method offers the potential for more accurate treatment and further study of neurovascular/cerebrovascular hemodynamics. The first study of the method is presented.

Angiography, Digital Subtraction↗

[Clinical studies on treatment of patients with malignant spinal tumors by percutaneous vertebroplasty under guidance of digital subtraction angiography].

OBJECTIVE: To investigate the clinical therapeutic effects on malignant spinal tumors treated by percutaneous vertebroplasty (PVP) under the guidance of the digital subtraction angiography (DSA). METHODS: A retrospective analysis was performed in 196 patients (99 males and 97 females, aged 23-85 years, averaged 60.4 years) with malignant spinal tumors, who underwent the PVP treatment combined with standard chemotherapy and other comprehensive treatment from January 2002 to January 2005. The malignant spinal tumors had their origins as follows: lung cancer (66 cases), breast cancer (55 cases), liver cancer (19 cases), colon cancer (15 cases), stomach cancer (9 cases), prostate cancer (12 cases), multiple myeloma (16 cases), and malignant lymphoma of the spine (4 cases). The metastatic tumors involved the cervical vertebra (32 cases), thoracic vertebra (93 cases), lumbar vertebra (71 cases), and spinal column, including 1 vertebral segment (135 cases), 2 segments (50 cases), and more than 3 segments (11 cases). During the follow-up survey, changes in the visual analogue pain scale (VAS) and changes in the X-ray measurements of the average anterior height, midline height, and posterior height of the diseased vertebra were observed. RESULTS: The follow-up for 6 months to 3 years revealed that the percutaneous vertebroplasty on 279 vertebral segments had a success with an operational success rate of 100%. Bone cement was injected into the lesions 1-9 ml per segment of the spine. The postoperative X-ray and CT evaluations revealed that spinal stabilization was obtained in all the patients. After operation, 193 (98.5%)patients had an obvious decrease or disappearance of the pain in the lower back, and only 3 (1.5%) patients had no obvious improvement in the pain. There was a significant statistical difference in the VAS scores between before operation and after operation (P < 0.05). There were also significant statistical differences in the average anterior height of the diseased vertebra between before operation and after operation (15.71 +/- 2.80 mm vs. 16.61 +/- 3.01 mm), in the midline height (13.65 +/- 2.93 mm vs. 14.52 +/- 2.72 mm), and in the posterior height (23.67 +/- 2.81 mm vs. 23.70 +/- 3.13 mm, P < 0.05). The patients with lung or liver cancer had a mean survival time of 9 months after PVP; the patients with breast cancer, stomach cancer, prostate cancer, lymphoma, or other metastatic tumors had a mean survival time of 18 months. The patients with multiple myeloma had a mean survival time of 27 months. The differences were statistically different (P < 0.01). CONCLUSION: PVP under the guidance of the DSA is an easier operation with a small wound and few complications. It can effectively alleviate the patient's pain due to metastatic spinal tumor, stabilize the spine, improve the patient's quality of life, and reduce the incidence of paraplegia.

Adult↗

A dynamic phantom for generation of contrast bolus curves for the evaluation of digital subtraction angiography systems.

A solid dynamic phantom has been constructed, which allows quantitative measurements of the signal-to-noise ratios in processed images from digital subtraction angiography (DSA) units. Profiles of silicone rubber placed in concentric circles on a plate which is rotated in the image plane generates bolus curves with five different transit times in each examination. The phantom is suited for measurement on DSA units working with matched or recursive filtering.

Angiography, Digital Subtraction↗

[Destructive bladder mole--follow-up by human chorionic gonadotropin (HCG), ultrasound and digital subtraction angiography (DSA)].

A case report of a mola destruens is presented including the clinical monitoring and the therapeutical conclusions. Control parameters were the HCG, ultrasound and DSA. The DSA in a new and improved technique, provided helpful information during a critical phase of the disease, when changing from mono- to polychemotherapy was necessary. Furthermore, the excellent vascular mapping enables planning of radiological interventions. In case of tumour bleeding hysterectomy can be avoided by embolisation. There may thus be more time for conservative treatment by chemotherapy.

Adult↗

Bilateral renal cell carcinoma in a horseshoe kidney: preoperative assessment with MRI and digital subtraction angiography.

Renal cell carcinoma in a horseshoe kidney is an unusual entity. To our knowledge, only 123 cases have been published to date. We report the first bilateral case of two clear-cell carcinomas in an asymmetrically fused kidney. Optimum preservation of renal function after radical tumor removal requires accurate preoperative imaging. Since the vascular supply in fusion anomalies is extremely variable, angiography is mandatory. Magnetic resonance imaging was most suitable to predict the tumor extent and localization, because it simultaneously gave the most comprehensive anatomical overview of the malformation.

Adenocarcinoma, Clear Cell↗

Digital subtraction angiography in musculoskeletal tumors and other conditions.

One hundred and forty consecutive DSA examinations of various musculoskeletal diseases were analyzed with respect to the contributions and/or limits of this modern diagnostic imaging modality. Angiography remains the imaging tool of choice for many benign and malignant orthopedic conditions of bones and soft tissues, mainly when MRI is still not generally available. It remains indispensable for embolization and/or local chemotherapy. DSA has the advantage of being less invasive and it also surpasses analog arteriography in better visualization of vascular patterns hidden in hyperostosis, sclerosis, and metallic shadows. Angiographic investigations, when necessary, should therefore start with DSA.

Adolescent↗

[Digital subtraction angiography for congenital heart disease].

From January 1988 to May 1989, ten infant patients (15 times) with congenital heart disease were studied by digital subtraction angiography (DSA) pre and/or postoperatively. The diagnoses of the patients include total anomalous pulmonary venous return (TAPVR), transposition of great arteries, patent ductus arteriosus with pulmonary hypertension, giant hemangioma of the left leg, asplenia (two cases), tetralogy of Fallot (two), and tricuspid atresia (two). Two newborn patients (TAPVR, giant hemangioma) were in critical condition preoperatively, but were diagnosed precisely and nonivasively by DSA. Ten cases were studied for estimation of operative repair and consequently five of them were diagnosed to require reoperation. It is concluded that DSA is of use for diagnosis of congenital heart diseases and for postoperative evaluation of infant patients under critical condition.

Angiography, Digital Subtraction↗

Clinical experience with iobitridol 250-300 in digital subtraction angiography. Double-blind randomized studies vs. iopromide and iohexol.

Iobitridol was clinically tested in DSA against iopromide (i.v. DSA) or iohexol (i.a. DSA) in 139 patients. Seven patients participated in the i.v. DSA trial and 60 in the i.a. DSA study. Each examination was rated as diagnostic or not and the image quality was noted. Nature, onset, intensity and outcome of each adverse reaction were recorded. There was no significant difference in imaging quality and side effect occurrence between the 2 groups. We conclude that iobitridol is a safe and efficient contrast medium, which can be recommended for DSA examinations.

Angiography, Digital Subtraction↗