PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Device Removal”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34Linked to original sources

Use of horizontal alveolar distraction osteogenesis for implant placement in a narrow alveolar ridge: a case report.

Although alveolar distraction is a promising method for ridge augmentation involving the atrophic maxilla or mandible for implant placement, techniques of horizontal and oblique alveolar distraction for expanding a narrow alveolar ridge have not been established. A case of horizontal alveolar distraction for implant placement using a titanium mesh plate and a distraction screw is reported. Horizontal alveolar distraction was performed on a patient with an extremely atrophic alveolar ridge in the anterior mandibular region. Two transport segments using horizontal osteotomies were prepared, and 2 horizontal alveolar distraction devices were inserted. After a 7-day waiting period, the devices were activated and alveolar widening was performed labially (0.225 mm twice a day for 14 consecutive days). Three months after consolidation, the distraction devices were removed. The distracted areas were completely filled with newly formed solid bone tissue. Two months after the device was removed, 4 endosseous implants were placed and an implant-supported definitive prosthesis was placed. This method of horizontal alveolar distraction appears to be clinically useful for the placement of implants in atrophic or knife-edged alveolar ridges.

Alveolar Process↗

Healing of rabbit tibial fractures using external fixation. Effects of removal of the fixation device.

Bone healing after external fixation of rabbit tibial osteotomies was studied in order to throw light on the problem of the optimal time for removal of external fixation. The animals were divided into various groups according to different periods of time for removal of external fixation and sacrifice. The strength and stiffness of the healing bones at 12 weeks were greater in tibiae where the external fixator was removed at 4, 6 or 9 weeks than in those with the continuous presence of the fixator for 12 weeks. Although fixation is essential in the early healing period, it seems that bone healing is stimulated by the removal of the fixation after a certain period of time. The optimum time for removal of external fixation in the rabbit tibia was at 6 weeks of healing, when the bone had regained normal stiffness and about 50 per cent of normal strength. The clinical relevance of this investigation is that it might be rational to remove the external fixator before bone healing has been completed. If it is felt that healing is not secure when the fixator is removed, a tibial brace might subsequently be used for a short period.

Animals↗

Hamstring insertion site healing after anterior cruciate ligament reconstruction in patients with symptomatic hardware or repeat rupture: a histologic study in 12 patients.

PURPOSE: Our goal was to characterize the type of biologic anchor of hamstring tendons to the femoral tunnel in cases of transfixion fixation for the anterior cruciate ligament (ACL) reconstruction. The histologic bone-hamstring tendon anchorage is not yet clearly understood despite many experimental and some clinical studies. It constitutes the weak point of the ACL reconstruction. The type of fixation, either distant from the joint such as transfixion fixation or at the tunnel entrance such as aperture fixation will determine a specific tendon-bone healing process. TYPE OF STUDY: Histological study. METHODS: We performed ACL reconstruction with 4 strands of semitendinosus and gracilis tendons fastened by a transfixion fixation. Femoral fixation was secured by transfixion (Transfix; Arthrex, Naples, CA) and tibia fixation by a biodegradable interference screw and 2 staples. Between 3 and 20 months after surgery, we performed 12 hamstring tendon biopsies (in 9 men and 3 women; mean age, 29 years). Biopsies were performed 2 cm from the femoral outlet in 10 patients undergoing hardware removal or by coring the femoral tunnel in 2 cases of repeat rupture. In 8 cases, the femoral device was removed for persistent lateral pain, in 2 cases for instability of the hardware, and in 2 cases a repeat rupture of the graft occurred. The samples were taken by coring a tunnel 5 mm in diameter, with a tubular harvester, along the femoral Transfix axis. Each fragment was stained with H&E, Solochrome cyanine, or Masson-trichrome, and microscopical examination was performed, including polarized light. RESULTS: At 3 months (in 1 case), a fibrovascular interface was seen between the tendon and uncalcified osteoid with very few collagen fibers. At 5 and 6 months (in 2 cases), some Sharpey-like fibers and less immature woven bone was seen. Maturity of the secondary insertion was seen after at least 10 months in 5 cases. In 2 cases, no contact was seen at the biopsy site despite good clinical stability. The 2 remaining cases underwent repeat rupture at the midsubstance of the graft at 12 and 17 months after surgery. In the first case, the tendon-bone fixation was limited at the outlet of the femoral tunnel with no fixation inside the tunnel. In the second case, the fixation was continuous with Sharpey fibers along the tunnel. CONCLUSIONS: According to our histologic results in patients, the time to obtain a mature indirect anchorage at the top of the tunnel was 10 to 12 months, which is much longer than in reported animal models (6 to 24 weeks). To our knowledge, this is the first clinical study reporting the histologic type of femoral ligament insertion 2 cm from the outlet of the tunnel with hamstring autograft for ACL reconstruction.

Adult↗

Intravesical migration of intrauterine device resulting in pregnancy.

Spontaneous migration of an intrauterine device into the bladder is very rare. A 29-year-old woman in whom an intrauterine device had been placed 6 years previously, presented complaining of chronic pelvic pain and recurrent irritative urinary tract symptoms. One year after insertion she had became pregnant and given birth without complications. Intravesical migration of the intrauterine device was confirmed by sonography and cystoscopy. The intrauterine device was removed by suprapubic cystostomy.

Adult↗

Midterm follow-up of patients who underwent removal of a left ventricular assist device after cardiac recovery from end-stage dilated cardiomyopathy.

OBJECTIVE: Cardiac recovery in end-stage idiopathic dilated cardiomyopathy recently occurred after temporary support with a left ventricular assist device. We report the case histories of patients who underwent removal of the device more than 4 years ago. METHODS: Since June 1994, 23 patients with end-stage idiopathic dilated cardiomyopathy who were supported by a left ventricular assist device or biventricular assist device for 1 to 26 months (mean, 6 months) underwent removal of the device after complete or extensive cardiac recovery, as revealed by echocardiography. RESULTS: Seven patients (group A) had recurrent cardiac failure after 4 to 24 months. Transplantation was performed in 6 patients, and one died while on the waiting list. Three patients died of noncardiac causes within a period of 4 months and 3 days after removal of the assist device. Stable cardiac recovery occurred in 13 patients (group B) for 3 to 49 months (mean, 23 months). At the time of implantation, there were no significant differences between the groups with regard to age, hemodynamics, left ventricular ejection fraction, left ventricular internal diameter in diastole, and autoantibody levels. The increase of ejection fraction and the decrease of left ventricular internal diameter in diastole after 2 months were highly significant. The patients in group A had longer histories of heart failure and first cardiac symptoms and duration of assist when compared with group B. Group B demonstrated a quicker cardiac recovery on the assist device, and thus support was shorter. Also, the degree of recovery at assist device explantation was more complete in group B. The age at the time of device placement was the only influencing factor for duration on the assist device. The probability of recurrence of heart failure was influenced by the duration of heart failure. CONCLUSIONS: In selected patients with idiopathic dilated cardiomyopathy, lasting recovery can be achieved after unloading with a left ventricular assist device. Lasting cardiac recovery seems to be related to functional normalization and a more rapid recovery during the unloading period.

Adolescent↗

The Camino intracranial pressure sensor: is it optimal technology? An internal audit with a review of current intracranial pressure monitoring technologies.

OBJECTIVE: To audit the reliability of the Camino intracranial pressure (ICP) sensor (Camino Laboratories, San Diego, CA) in our clinical practice as part of a continuing quality assurance program, and to assess its relative usefulness as compared with currently available ICP monitoring technologies that we reviewed. DESIGN: Prospective audit of ICP device reliability and function in 50 patients with head injuries. METHODS: Zero drift was recorded immediately after the ICP device was removed from the patient. Dynamic frequency response bench testing of each functioning catheter from 0 to 30 Hz and static calibration testing from 0 to 100 mmHg during environmental temperature variation from 22 to 40 degrees C were carried out. RESULTS: Zero drift (range, -13 to 22 mmHg; median, -1 mmHg) was recorded immediately after the devices were removed from patients. Seventeen (50%) of the devices tested for zero drift had absolute drifts of at least 3 mmHg. There was no correlation between recorded zero drift and duration of monitoring (r = 0.154, P = 0.207). Five sensors (10% of those tested) failed during patient monitoring and were replaced. Static and dynamic calibration tests of the functioning sensors were within the manufacturer's specifications. However, the sensitivity of the devices to environmental temperature remains a problem. CONCLUSION: The Camino ICP sensor remains one of the most popular ICP monitoring devices for use in patients with traumatic brain injuries. However, our recent in-house assessment demonstrated the robustness of the device to be less than adequate during routine practice. In this study, more than 50% exhibited zero drift greater than 3 mmHg, which is unacceptable in a catheter tip ICP monitoring device in which zero drift and calibration cannot be checked in vivo. A review of the literature revealed that other available ICP monitoring devices may prove to be more reliable and thus more appropriate for routine clinical measurement of ICP.

Equipment Design↗

[Surface changes in the dental enamel resulting from acid etching and the bonding and removal of orthodontic fixation devices (based on data from scanning electron microscopy)].

The effect of acid etching of the enamel, its adhesion with Concise compound, and the state of enamel after removal of orthodontic fixing rods attached right to the dental enamel, were studied on 32 teeth extracted for orthodontic reasons. Best conditions for retention were achieved with 2-min etching with 40% phosphoric acid. This ensured the concise penetration into the enamel to 60 microns depth. The fixing rods removal did not lead to irreversible enamel damage.

Acid Etching, Dental↗

Hysteroscopic management of intra-uterine devices with lost strings.

We report a series of 38 patients with intra-uterine devices with lost strings where hysteroscopic aid was required after routine retrieval procedures failed. Thirty-five intra-uterine devices could be removed easily with hysteroscope. In one patient a fragmented Lippes Loop was removed piecemeal hysteroscopically. Laparotomy was required in only one patient, for an extra-uterine Copper T. Hysteroscopy is thus a simple, safe and effective method for removing misplaced intra-uterine devices.

Adult↗

Etonogestrel implant (Implanon) for contraception.

Levonorgestrel 38 mg subdermal implant (Norplant), intended to provide contraception for 5 years, was withdrawn in the UK in 1999 due to unwanted effects (menstrual disturbances) and difficulties in removing the device. Since then, [symbol: see text]etonogestrel implant (Implanon-Organon), another progestogen--only subdermal contraceptive device, has become available in the UK. The manufacturer claims that etonogestrel implant provides contraception for up to 3 years and is easy to insert and remove. Here, we consider the place of etonogestrel implant.

Contraceptive Agents, Female↗

Removal of UroLume endoprosthesis: experience of the North American Study Group for detrusor-sphincter dyssynergia application.

PURPOSE: We present the experience of the North American UroLume Multicenter Study Group with removal of the UroLume endoprosthesis. MATERIALS AND METHODS: A total of 160 neurologically impaired patients were enrolled in the North American UroLume Multicenter Study Group for detrusor external sphincter dyssynergia application. Analysis was performed in 2 groups of patients in which the device was removed during insertion and after implantation, respectively. RESULTS: Device retrieval was required during insertion in 21 patients (13%) mainly due to misplacement or migration in 17. Extraction was done with minimal complications and in all but 2 cases subsequent UroLume implantation was successful. Of 158 men with the device in place 31 (19.6%) required removal. In 34 procedures 44 devices were removed, mainly due to migration. Time from implantation to removal ranged from 4 days to 66 months (mean 22 months). The UroLume was removed en bloc in 20 cases and in parts or wire by wire in 19. The majority of patients had no or minimal complications after extraction. Only 2 patients had serious temporary complications, including bleeding and urethral injury, with no lasting consequences. No malignancy developed as a result of UroLume insertion. CONCLUSIONS: While there is a potential for urethral injury and bleeding, UroLume endoprosthesis removal is largely a simple procedure with minimal complications and consequences.

Humans↗

PEG ileus. A preventable complication.

Percutaneous endoscopic gastrostomy (PEG) tube placement is an established procedure in the nutritional management of patients. There are numerous reports in the literature describing the techniques for placing PEG tubes. However, there are few reports that discuss the proper methods for removing these devices and the complications that may result from incorrectly removing a PEG tube. An increasing number of patients with PEG tubes are being cared for by individuals who are not familiar with these devices and their proper method of removal. The use of an incorrect method to remove a PEG tube may result in significant morbidity to the patient. We report a case of bowel obstruction resulting from the incorrect removal of a PEG tube that required laparotomy. To prevent similar complications, PEG tubes should be removed using the appropriate method by individuals familiar with the device.

Aged↗

Hysteroscopic removal of occult intrauterine contraceptive device.

Dilatation and curettage or hooking an occult intrauterine contraceptive device (IUD) may fail to recover the device on occasion. Theoretically, endoscopic observation should enable the controlled removal of this type of device. Of 200 patients who underwent hysteroscopic examination, 10 had an occult IUD. In 8 cases, the device was visible through the hysteroscope, and in 6 patients a successful removal was accomplished with this endoscopic technic. Failures and problems are discussed, and the importance of adequate preoperative study is stressed. Hysteroscopy is an effective procedure in the recovery of the occult intrauterine contraceptive device in selected nonpregnant patients.

Adult↗

[A simple and rapid method for removal of broken unreamed tibial nails].

By using UTN in the treatment of very distal tibia fractures delayed fracture-healing and pseudarthrosis with breakage of the nail are described. The removal of the distal solid part of the nail shows a special difficulty. We report about two cases of broken UTN in 1997. A simple extraction device to remove the distal part of the broken nail is demonstrated.

Adult↗

Eradication by surfactant irrigation of Staphylococcus aureus from infected complex wounds.

Treatment of infected orthopaedic hardware usually requires the removal of the appliance. When the device is removed and immediately replaced, persistent infection frequently complicates this exchange procedure. We modeled the exchange procedure in rats by passing a wire suture through a posterior spinous process and then contaminating the wound with Staphylococcus aureus. We then investigated whether a sequence of surfactant enriched irrigation solutions (Castile soap followed by benzalkonium chloride, sequential surfactant irrigation) had a greater capacity to eradicate Staphylococcus aureus from the experimental wound than did the standard wound irrigant, normal saline. When we left the wire in place through the 2-week course of the study, sequential surfactant irrigation showed only a modest advantage over normal saline (staphylococci recovered from 39% versus 58% of wound cultures respectively). Simple removal of the wire 24 hours after implantation and bacterial contamination prevented wound infection in most animals (with the wire removed, 38% of the animals remained infected versus 85% with the wire left in place), without regard to the irrigation solution. Alternatively, when we removed the wire after 24 hours, irrigated the wound, and then placed a fresh wire back into the wound, sequential surfactant irrigation showed a significant advantage over NS (54% of the animals irrigated with sequential surfactants remained infected versus 100% of the animals irrigated with normal saline). Our findings confirm the importance of a contaminated medical device for promoting foreign body infection; our findings also show that sequential surfactant irrigation has therapeutic value in a rat model of orthopaedic device infection; this irrigation protocol should be studied further as a potential agent for the treatment of infected orthopaedic wounds.

Animals↗

Fluorescence imaging microscopy of cellular markers in ischemic vs non-ischemic cardiomyopathy after left ventricular unloading.

BACKGROUND: The heart undergoes repair and initiates protective mechanisms via ventricular unloading. We examined the presence of 2 markers in pre-unloaded and post-unloaded human cardiac tissue that are important indicators of cardiac failure, tumor necrosis factor-alpha and inducible nitric oxide synthase. We also measured 2 nuclear transcription factors, NFkappaB50 and NFkappaB65, comparing quantities and localizations to determine if mechanical unloading reduced their presence, as these markers are also thought to be indicators of impending heart failure. Amounts and localizations in patients that had been diagnosed with either ischemic or non-ischemic cardiomyopathy were compared after mechanical unloading with a left ventricular assist device. To establish that unloading had been achieved, levels of atrial natriuretic protein were determined. METHODS: Core biopsies were harvested at assist device implantation and removal. Fluorescence deconvolution microscopy image reconstructions of fluorescence probes were correlated with data obtained by western Blot and electrobility shift assays. RESULTS: Statistically significant differences in localization and amounts of tumor necrosis factor and nitric oxide synthase were seen between pre- and post-assist device samples. Amounts of tumor necrosis factor and nitric oxide synthase in ischemic tissue were increased at the time of assist device removal, but decreased in dilated or idiomyopathic samples. Ventricular unloading resulted in reduced levels of natriuretic protein, with the greatest reduction being seen in ischemic tissue. Both NFkappaB50 and NFkappaB65 increased in ischemic tissue, but only NFkappaB50 in non-ischemic samples. CONCLUSIONS: Changes in localization of the factors and altered levels of cytokine and nitric oxide synthase indicate that the heart switches to a "protective and repair" mode, and mechanical unloading allows this transition to occur. Observed changes were dependent on the etiology of the disease.

Atrial Natriuretic Factor↗