Hufnagel procedure reconverted by endovascular leaflet dislocation and extirpation.

Before the development of standard aortic valve replacement, Hufnagel treated aortic insufficiency by implanting a ball-valve prosthesis in the descending thoracic aorta. In a patient who, after four major thoracic procedures, ultimately received two mechanical bileaflet valves in series (one in the ascending and one in the descending aorta), the downstream prosthesis became progressively immobilized, with total blockage of the leaflets in the open position due to insufficient transvalvular negative pressure gradient. After evaluation of this particular situation in an experimental model, we predicted blockage of the downstream prosthesis, once the ascending valve had regained normal function, and easily cleared the blockage of the distal valve by removing the two leaflets using balloon inflation. Normal circulation was clinically restored in three separate steps. (a) Normal function was re-established surgically in the ascending aorta position. (b) A second thoracotomy was avoided by endovascular dislocation of both blocked descending thoracic leaflets through endovascular balloon inflation. (c) Both leaflets embolized to the level of the left common iliac artery, where the nearly intact leaflets were removed surgically, finally creating a near-normal circulatory situation.

Aorta, Thoracic↗

Optimal size of prostheses for functioning of the aortic prosthetic valve in aortic and mitral valve replacement with annular enlargement through Manouguian's technique.

There is not yet agreement about the optimal size of the prostheses in aortic and mitral valve replacement with Manouguian's technique. In this technique, the aortic prosthetic valve can be pushed upon the mitral prosthesis which may cause dysfunction of the aortic prosthetic valve. The aim of this study was to clarify the size of the prostheses needed to avoid dysfunction of the aortic prosthetic valve. Three patients underwent aortic and mitral valve replacement through this procedure. Two of them had active aortic and mitral valve endocarditis. Aortomitral continuity involved with abscesses could be approached and completely excised using this technique. All patients survived the operation, but 1 of them suffered aortic mechanical valve dysfunction for the reason stated. Anatomical analysis of the geometrical relation of the 2 prosthetic valves suggests that the mitral annulus should be enlarged less than 25 mm to avoid dysfunction of the aortic prosthetic valve.

Adult↗

Percutaneous transcatheter aortic disc valve prosthesis implantation: a feasibility study.

PURPOSE: Over the past 30 years there have been experimental efforts at catheter-based management of aortic valve regurgitation with the idea of extending treatment to nonsurgical candidates. A new catheter-based aortic valve design is described. METHODS: The new catheter-delivered valve consists of a stent-based valve cage with locking mechanism and a prosthetic flexible tilting valve disc. The valve cage is delivered first followed by deployment and locking of the disc. In acute experiments, valve implantation was done in four dogs. RESULTS: Valve implantation was successful in all four animals. The implanted valve functioned well for the duration of the experiments (up to 3 hr). CONCLUSION: The study showed the implantation feasibility and short-term function of the tested catheter-based aortic disc valve. Further experimental studies are warranted.

Animals↗

Reoperation is not an independent predictor of mortality during aortic valve surgery.

OBJECTIVE: Reoperations on aortic valves are associated with increased mortality, which may affect valve prosthesis selection at the time of initial aortic valve replacement. We analyzed our experience to determine whether reoperation itself independently predicts mortality during aortic valve surgery. METHODS: Demographic, intraoperative, and outcome data were collected prospectively on patients undergoing primary or redo aortic valve replacement or Bentall procedures after previous aortic valve replacement with or without concomitant coronary bypass grafting at a single institution from 1990 through 2002. Logistic regression analyses validated by means of bootstrap methodology identified the predictors of hospital mortality and the independent effect of reoperation. RESULTS: Of 2673 patients undergoing aortic valve surgery, 2375 were primary operations, 216 were reoperations, and 82 were Bentall-after-aortic valve replacement procedures. Of 298 reoperations, 32 were third and 5 were fourth procedures. Mortality was 2.3% for primary operations, 4.6% for redo aortic valve replacement, and 2.4% for Bentall-after-aortic valve replacement procedures. Most patients underwent elective procedures, with mortalities of 1.6%, 1.7%, and 2.5%, respectively. Hospital mortality was independently predicted by peripheral vascular disease (odds ratio, 3.6), active endocarditis (odds ratio, 2.9), worsening New York Heart Association class (odds ratio, 2.3), and need for annular enlargement (odds ratio, 2.1). Reoperation itself did not predict hospital mortality. CONCLUSIONS: The risk of mortality during aortic valve surgery is due mostly to active endocarditis, New York Heart Association class, and comorbidity. We failed to find a significant effect of reoperation on perioperative mortality. Mechanical valves, with their attendant anticoagulation-related morbidity, should not be implanted solely because of anticipated high mortality associated with bioprosthetic rereplacement.

Aged↗

[Value of early systematic transoesophageal ultrasonography after mitral valve replacement by Saint-Jude prosthesis].

The aim of this study was to assess the value of the routine multiplane transoesophageal echocardiography (TEE) in the early postoperative period after mitral valve replacement with a Saint Jude Médical (SJM) mechanical prosthesis. This prospective work enrolled 56 patients who have been operated between September 1999 and September 2001, all these patients had a multiplan TEE after 14.7 days (8-29 days) of post-operative. The effect of peri-prosthetic leaks was 59%. They were always minimal and asymptomatic. 68% of them disappeared at the late exam. An asymptomatic intermittent blockage of an leaflet had been noted in one patient. It appears to us today indispensable to achieve a systematic TEE in the early post operative period after mitral valve replacement. This exam remains little aggressive and comfortably supportable by the patient in look of information brought.

Adult↗

When is concomitant aortic valve replacement indicated in patients with mild to moderate stenosis undergoing coronary revascularization?

Mild to moderate aortic stenosis is a common finding in patients presenting for coronary artery bypass grafting (CABG), and its management is controversial. However, review of available data suggests a surgical strategy for these patients. Recent data demonstrate that 1) progression of aortic stenosis is more rapid in those with leaflet calcification; 2) the addition of aortic valve replacement to CABG in patients with mild to moderate stenosis does not increase hospital mortality when compared with bypass surgery alone; 3) hospital mortality for aortic valve replacement after previous bypass surgery has declined in recent years; 4) aortic valve replacement places the patient at risk for prosthesis-related complications; 5) the limited 10-year survival (competing risk of death) leaves only a minority of individuals with mild aortic stenosis alive and eligible for aortic valve replacement 10 years after bypass surgery; and 6) combined aortic valve replacement and CABG confers a survival benefit in those with moderate aortic stenosis but not in those with mild aortic stenosis. Therefore, in the coronary artery bypass patient with moderate aortic stenosis, leaflet calcification, and life expectancy greater than 5 years, concomitant aortic valve replacement is advised. In contrast, aortic valve replacement is rarely indicated in those with mild aortic stenosis.

Actuarial Analysis↗

A retrospective comparative study of aortic valve replacement with St. Jude medical and medtronic-hall prostheses: a 20-year follow-up study.

OBJECTIVE: To compare the long-term clinical outcome of patients who underwent aortic valve replacement with St. Jude Medical and Medtronic-Hall mechanical prostheses. DESIGN: From June 1978 to June 1982, 43 Medtronic-Hall and 48 St. Jude Medical mechanical valves were implanted in 90 consecutive patients with aortic valve disease, and their clinical outcome was retrospectively assessed. RESULTS: At 20 years in the St. Jude Medical group and in the Medtronic-Hall group the actuarial rates of overall survival were 50 and 49% (p = NS), of cardiovascular survival 66 and 63% (p = NS), of valve-related survival 95 and 91% (p = NS), of freedom from major valve-related complications 83 and 45% (p = 0.005), from major cerebrovascular events 93 and 71% (p =0.06), from valve thrombosis 97 and 89% (p = NS), from aortic valve reoperation 93 and 88% (p = NS), from major bleeding 96 and 82% (p = 0.04), and from endocarditis 93 and 82% (p = NS), respectively. The linearized rate of overall major aortic valve prosthesis-related complications was 3.47%/year in the Medtronic-Hall valve group and 1.53%/year in the St. Jude Medical valve group (p = 0.003). Multivariate analysis showed that the type of prosthesis was predictive of freedom from valve-related complications (p = 0.01; 2.849; C.I. 95%: 1.246-6.516). CONCLUSION: The aortic St. Jude Medical mechanical valve seems to be associated with a slightly lower rate of long-term valve-related morbidity than the aortic Medtronic-Hall mechanical valve. Because of the small patient population and the retrospective nature of the study, the choice between these two prostheses should not be made only on the basis of these findings. However, these results suggest a reappraisal for further comparative studies with such an extended follow-up.

Adult↗

Influence of bileaflet prosthetic mitral valve orientation on left ventricular flow--an experimental in vivo magnetic resonance imaging study.

OBJECTIVE: Orientation-related bileaflet mechanical valve flow and velocity studies in the downstream area are limited in mitral valve replacement studies. METHODS: In five sheep, ventricular blood flow was visualized prior to the implantation of a mitral Edwards Mira Bileaflet Mechanical Valve Model 9600. The implant orientation was either anatomic, with a 45 degrees rotation, or anti-anatomic, with a 90 degrees rotation. Sheep were positioned within an 1.5T field strength MR scanner (Magnetom Sonata; Siemens) to assess time-dependent three-dimensional blood flow velocities displayed as color-encoded vectors. RESULTS: The preoperative ventricular velocity profiles presented negligible individual variances. Streamlines passed homogeneously without any spatial differences into the left ventricle. Starting from the anatomical position, the areas with inhomogeneous and accelerated local blood velocities increased in comparison to the preoperative status. Rotating the prosthesis until it was in a 45 degrees position caused a significant increase in turbulence immediately downstream; fluids stagnated longer at the apex. In the anti-anatomic orientation, mean velocities decreased. In all three positions, but less so in the anatomical position, the flow pattern of the blood helix at the apex was disturbed. The intraventricular flow patterns between prostheses in the three orientations were, however, not significant when compared to the differences between physiologic intraventricular flow and any of the postoperative measurements. CONCLUSIONS: To achieve optimal hemodynamics, rotation of the mitral valve has to be considered carefully, as has long been known from aortic valve replacement studies. To this end, a method for qualitative assessment of left ventricular blood flow patterns was developed.

Animals↗

Echocardiographic imaging of stentless aortic valve prostheses.

UNLABELLED: Homografts and stentless xenografts are increasingly used in aortic valve surgery. Echocardiography technicians and cardiologists have to know what they will find when performing an echo-Doppler examination in patients who received a stentless valve. We therefore evaluated echocardiographic images of 74 patients who received a Freestyle stentless bioprosthesis with three techniques and a follow-up of 2 years in two high-volume hospitals. Of the patients studied, 81% were operated using the subcoronary technique, 12% using the root-inclusion technique, and 7% using the full-root technique. RESULTS: Transvalvular gradients across the stentless valves were low: 8.0 mmHg when implanted with the subcoronary technique, 8.2 +/- 5.1 mmHg using the root-inclusion technique, and 6.5 mmHg using the full-root technique. Trivial aortic insufficiency (grade 1) was observed in 10.7% of the patients (8.9% for the subcoronary technique, 13% for the root-inclusion technique, and 0% for the full-root technique). When the bioprosthesis was implanted using the subcoronary technique or the root-inclusion technique, the prosthesis was placed inside the recipient aortic root. Using these techniques, a lumen between the double layer of the xenograft and the aortic wall could be observed. With the root-replacement technique, the porcine root became the most proximal part of the ascending aorta. As the native aortic wall was removed, in most cases, no double lumen could be observed with imaging of the ascending aorta.

Aortic Valve↗

Fatal leaflet escape in an Edwards TEKNA aortic prosthesis.

The case is reported of a 26-year-old male patient who died eight years after the replacement of an aortic valve with a bileaflet mechanical valve (TEKNA; Edwards, USA). Following prosthesis implantation, the patient had been in a good state of health, and his death occurred unexpectedly. Forensic autopsy revealed a leaflet escape, with two fragments of the leaflet being found bilaterally in the common iliac arteries. Death occurred due to an acute cardiac insufficiency. Immunohistochemical investigations revealed fresh myocardial fiber necroses. Stereomicroscopic and scanning electron microscopic investigations demonstrated surface erosions of the leaflet. Although the valve was withdrawn from the market in June 2000, it had previously been implanted in over 18,000 patients. Thus, from a clinical viewpoint, the question of using a prophylactic replacement in affected patients must be discussed.

Adult↗

Clinical and hemodynamic performance of the 19-mm medtronic mosaic bioprosthesis.

BACKGROUND AND AIM OF THE STUDY: The Medtronic Mosaic valve (MMV) is a latest generation supra-annular stented porcine valve, which combines a low-profile stent, leaflet fixation at zero pressure in a predilated aortic root, and amino-oleic acid anti-mineralization treatment for improved hemodynamics and durability. A study was conducted to evaluate the clinical and hemodynamic performances of the MMV in patients with a small aortic root (19 mm aortic annulus). METHODS: Between 1998 and 2004, 81 consecutive patients (69 females, 12 males; mean age 78.0 +/- 5.5 years) underwent aortic valve replacement using the 19-mm MMV. Concomitant coronary artery bypass grafting was performed in 28 patients (29.2%), and mitral valve surgery in one patient (1.2%). RESULTS: The 30-day mortality rate was 9.9% (eight deaths). Postoperative actuarial survival estimates were 90.1 +/- 3.3%, 78.5 +/- 4.6% and 69.1 +/- 5.5% at one month, one year and two years, respectively. After a mean follow up of 2.7 +/- 1.9 years, no cases of structural dysfunction, non-structural dysfunction or valve thrombosis were noted. Four ischemic cerebral complications (2.0% per patient-year (pt-yr)), five bleeding complications (2.0%/pt-yr) and two prosthetic valve infections (1.0%/pt-yr) were observed. No reoperation on a MMV was performed. Postoperatively, the mean systolic gradient was 23.4 +/- 7.0 mmHg, and the effective orifice area (EOA) 1.06 +/- 0.33 cm2. Valve prosthesis-patient mismatch (VP-PM) was moderate (indexed EOA > 0.65 cm2/m2 and < or = 0.85 cm2/m2) in 40 patients (49.4%), and severe (indexed EOA < or = 0.65 cm2/m2) in 41 (50.6%). CONCLUSION: Although providing acceptable clinical results, implantation of the 19-mm MMV resulted in a high incidence of postoperative VP-PM. Hence, this valve should be reserved for patients in whom the projected indexed EOA calculated preoperatively is deemed acceptable, given the patient's clinical condition.

Aged↗

Structural valve deterioration in mitral replacement surgery: comparison of Carpentier-Edwards supra-annular porcine and perimount pericardial bioprostheses.

BACKGROUND: Bioprostheses preserved with glutaraldehyde, both porcine and pericardial, have been available as second-generation prostheses for valve replacement surgery. The performance with regard to structural valve deterioration with the Carpentier-Edwards supra-annular (CE-SAV) porcine bioprosthesis and the Carpentier-Edwards Perimount (CE-P) pericardial bioprosthesis (Baxter Healthcare Corp, Edwards Division, Santa Ana, Calif) was evaluated to determine whether there was a difference in mitral valve replacement. METHODS: The CE-SAV bioprosthesis was implanted in 1266 overall mitral valve replacements (isolated mitral, 1066; mitral in multiple, 200) and the CE-P bioprosthesis in 429 overall mitral valve replacements (isolated mitral, 328; mitral in multiple, 101). The mean age of the CE-SAV population was 64.2 +/- 12.2 years and that of the CE-P population, 60.7 +/- 11.7 years (P =.0001). For the study, structural valve deterioration was diagnosed at reoperation for explantation. RESULTS: The freedom from structural valve deterioration was evaluated to 10 years, and the freedom rates reported are at 10 years. For the overall mitral valve replacement groups, the actuarial freedom from deterioration was significant (P =.0001): CE-P > CE-SAV for 40 years or younger, 80% versus 60%; 41 to 50 years, 91% versus 61%; 51 to 60 years, 84% versus 69%; 61 to 70 years, 95% versus 75%. The older than 70-year group was 100% versus 92% (no significant difference). The actual freedom from structural valve deterioration also demonstrated the same pattern at 10 years: 40 years or younger, CE-P 82% versus CE-SAV 68%; 41 to 50 years, 92% versus 70%; 51 to 60 years, 90% versus 80%; 61 to 70 years, 97% versus 88%; and older than 70 years, 100% versus 97%. The independent risk factors of structural valve deterioration for the overall mitral valve replacement group were age and age groups and prosthesis type (CE-SAV > CE-P). The prosthesis type either in isolated replacement or in multiple replacement was not predictive of structural valve deterioration. The pathology of structural valve deterioration was different: 70% of CE-P failures were due to calcification and 57% of CE-SAV failures were due to combined calcification and leaflet tear. CONCLUSION: The actuarial and actual freedom from structural valve deterioration, diagnosed at reoperation, is greater at 10 years for CE-P than for CE-SAV bioprostheses. The mode of failure is different, and the cause remains obscure. Long-term evaluation is recommended, because the different modes of failure may alter the clinical performance by 15 and 20 years.

Adolescent↗

Mitral valve replacement using bileaflet mechanical prosthetic valve in the first year of life.

OBJECTIVE: The operative management and long term outcome of mitral valve replacement in infancy remain a therapeutic challenge. The selection of a prosthetic valve for this particular age group might affect the clinical outcome. Here we present our experience of mitral valve replacement in 6 infants using small bileaflet mechanical prosthetic valves. METHODS: Between January 1994 and August 1997, 6 infants (their age ranged from 3 months to 11 months, and their body weight from 2978 g to 7403 g) underwent mitral valve replacement using a mechanical valve prosthesis (16 mm CarboMedics prosthetic valve in 5, and 17 mm St. Jude Medical prosthetic valve Hemodynamic Plus in 1). The preoperative morphological features of the mitral valve were stenosis in 1, regurgitation in 3, and a combination of these in 2. The prosthesis was fixed at the annulus in 3, and at the supra-annular position in 3. Anticoagulation was performed using warfarin. RESULTS: There was no operative mortality. Postoperative catheterization revealed an acceptable wedge pressure in the pulmonary arteries, ranging from 10 to 12 mmHg. During the mean follow-up period of 36 months, late death due to residual pulmonary hypertension occurred in 1 patient at 10 months after surgery. Excluding this patient, all remaining patients are doing well with no need for repeated operation with no thromboembolic complication. The actuarial survival rate and the reoperation free rate at 70 months are 83 +/- 15% and 100%, respectively. CONCLUSION: Mitral valve replacement using a small size bileaflet mechanical prosthetic valves in infancy can be performed with low operative mortality and with satisfactory mid-term results.

Follow-Up Studies↗

[St Jude's bi-leaflet aortic valve prosthesis throughout two decades. Quality profile and risk factors].

INTRODUCTION: The St Jude standard aortic bi-leaflet disc valve is still the most widespread. With almost 20 years of follow-up, the present material may describe the quality profile of the valve and the relevant risk factors throughout the remainder of most patients' lives. MATERIAL AND METHODS: A 100% complete follow-up was conducted of 694 adult patients who had an aortic valve replacement with the St Jude valve during 1980-1993. The Cox regression analysis was used to identify independent risk factors. RESULTS: Survival was 79%, 58%, 39%, and 37% at 5, 10, 15, and 18 years, respectively. Only 12% of the deaths (0.60%/patient-year) were valve-related with a 15-year freedom of 91%. Embolism (1.18%/patient-year) and anticoagulant-related bleeding (2.24%/patient-year) were the dominant complications with 15-year freedoms of 80% and 72%. Valve thrombosis was noted in two patients (0.04%/patient-year) who were off anticoagulation. Mechanical failure was not observed. Endocarditis (0.42%/patient-year) had a 15-year freedom of 92% compared with 72% and 54%, respectively, for major valve (2.33%/patient-year) and all valve-related complications together (4.33%/patient-year) and 96% for aortic valve reoperation (0.36%/patient-year). Age of the patient and heart-related variables were identified as independent risk factors for mortality and valve-related complications. CONCLUSION: With a follow-up of almost two decades showing a low incidence of valve-related deaths, acceptable thrombogenicity, and absence of mechanical failure, the St Jude bi-leaflet aortic disc valve sets the standard for contemporary mechanical valves.

Adult↗

Aortic root abscess and secondary infective mitral valve disease: results of surgical endocarditis treatment.

OBJECTIVE: Mortality in active infective endocarditis (AIE) is substantial and reinfection can strongly influence outcome. Assessment of factors influencing mortality is important. We studied 108 (33%) patients suffering from root abscess out of a total of 327 AIE patients admitted to the Deutsches Herzzentrum Berlin for surgical treatment between 1996 and 2003. Among them were 53 (25.5% of all patients) who were diagnosed as having secondary infective mitral valve disease (SMVD). Mean age was 53+/-14.2 years; there were 37 men and 16 women. METHODS: Risk factors were assessed on the basis of clinical, hemodynamic, echocardiographic and surgical information. Mean follow-up was 325+/-251 days with complete echocardiographic examination performed in patients with double valve surgery. The differences between groups were analyzed using Student's t-test. Multivariate analysis for the whole group suffering from abscess was performed to identify independent factors influencing mortality. RESULTS: In 19 (35.8%) patients suffering from SMVD mitral valve reconstruction was undertaken and mitral valve replacement was performed in 34 (64.2%) patients. There were 27 patients treated with a Shelhigh prosthesis: 18 with double valve replacement (both Shelhigh) and nine with an aortic Shelhigh prosthesis and concomitant mitral valve reconstruction. Homografts were used in 17 patients, with mitral reconstruction in 10 and a stented mitral prosthesis in seven. In nine cases two stented valve prostheses were used. The calculated mean Doppler gradient for homografts and Shelhigh in aortic position was 12 (+/-5.7) and 15 (+/-4.6), respectively (NS). The following predisposing factors for mortality were assessed: severe damage of aortic annulus (OR 4.65, CI 1.22-17.1, P=0.0159); septic shock (OR 3.44, CI 0.85-13.9, P=0.07) and poor ejection fraction (<40%), and dilated LV. CONCLUSIONS: Excessive mortality reaching 29% was noted in patients suffering from AIE with aortic ring abscess and SMVD requiring double valve surgery. Double valve surgery with semi-stented Dacron-free valve prostheses is associated with a low rate of reinfection and good function of the implants. The most potent independent risk factors for death were septic shock and severe aortic root destruction.

Abscess↗

Percutaneous aortic valve implantation retrograde from the femoral artery.

BACKGROUND: Percutaneous aortic valve implantation by an antegrade transvenous approach has been described but is problematic. Retrograde prosthetic aortic valve implantation via the femoral artery has potential advantages. Percutaneous prosthetic aortic valve implantation via the femoral arterial approach is described and the initial experience reported. METHODS AND RESULTS: The valve prosthesis is constructed from a stainless steel stent with an attached trileaflet equine pericardial valve and a fabric cuff. After routine aortic balloon valvuloplasty, a 22F or 24F sheath is advanced from the femoral artery to the aorta. A steerable, deflectable catheter facilitates manipulation of the prosthesis around the aortic arch and through the stenotic valve. Rapid ventricular pacing is used to reduce cardiac output while the delivery balloon is inflated to deploy the prosthesis within the annulus. Percutaneous aortic prosthetic valve implantation was attempted in 18 patients (aged 81+/-6 years) in whom surgical risk was deemed excessive because of comorbidities. Iliac arterial injury, seen in the first 2 patients, did not recur after improvement in screening and access site management. Implantation was successful in 14 patients. After successful implantation, the aortic valve area increased from 0.6+/-0.2 to 1.6+/-0.4 cm2. There were no intraprocedural deaths. At follow-up of 75+/-55 days, 16 patients (89%) remained alive. CONCLUSIONS: This initial experience suggests that percutaneous transarterial aortic valve implantation is feasible in selected high-risk patients with satisfactory short-term outcomes.

Aged↗

Prediction of stentless aortic bioprosthesis size with transesophageal echocardiography and magnetic resonance imaging.

BACKGROUND AND AIMS OF THE STUDY: During stentless bioprosthetic aortic valve replacement, ischemic time may be decreased by the non-invasive prediction of bioprosthesis size, allowing earlier commencement of prosthesis preparation. In this study we examine whether the addition of transesophageal echocardiography (TEE) to transthoracic echocardiography (TTE) aids in the prediction of stentless bioprosthesis aortic valve size. We also report our preliminary experience with the use of magnetic resonance imaging (MRI) in bioprosthetic valve size prediction. METHODS: Eight patients in whom elective aortic valve replacement with a Toronto SPV valve was planned underwent preoperative TTE and MRI, and intraoperative TEE. RESULTS: In all cases the combination of TTE and TEE correctly predicted the size of Toronto SPV valve inserted. In three cases, TEE led to a revision of the TTE-based prediction. The need for sinotubuloplasty in two patients was correctly predicted by both TTE and TEE. MRI of the aortic annulus correctly predicted valve size in three of four cases, but could not reliably identify the sinotubular junction. CONCLUSIONS: In aortic valve replacement the accuracy of prediction of stentless bioprosthesis size is improved by the addition of TEE to TTE.

Aortic Valve↗

Rupture of an aortic dissection into the right atrium in a patient with a previous aortic valve replacement: a case report.

We report the case of a 73-year-old man with a history of previous aortic valve replacement in 1990 and rupture of an aortic dissection into the right atrium. The patient was admitted to the emergency room because of chest pain, stopped not long after. The electrocardiogram did not show any signs of ischemia and myocardial enzymes were not increased. Transthoracic echocardiography revealed aortic root dilation (maximum diameter 60 mm) extended to the aortic arch, and the presence of a flow from the ascending aorta to the right atrium (evocative of a fistula between the two chambers). The aortic valvular prosthesis function was good. Transesophageal echocardiography confirmed an aorta-right atrium fistula. Cardiac catheterization did not show any luminal obstructions in the coronary arteries; there was a small shunt from the aorta to the right atrium. The ascending aorta and the aortic root were replaced with a Dacron graft. Right and left sinuses were reimplanted to the graft. The fistula was repaired with 4-0 pledgeted Prolene sutures. The surgeon's diagnosis was "type A aortic dissection in a patient with an ascending aorta aneurysm and an old ascending aorta-right atrium fistula".

Aged↗