The uncemented porous-coated anatomic total hip prosthesis. Two-year results of a prospective consecutive series.

Fifty uncemented porous-coated total hip prostheses were implanted in forty-seven patients whose mean age was fifty-eight years. Clinical hip-rating scores, as described by Harris, were determined and anteroposterior and frog-leg lateral radiographs were made preoperatively, shortly postoperatively, and at three months, six months, one year, and two years postoperatively. The mean hip-rating score was 92 points (range, (range, 74 to 100 points) at one year and 92 points (range, 69 to 100 points) at two years. The thigh was slightly painful in nine patients (18 per cent) at one year and in eight (16 per cent) at two years. Fourteen hips (28 per cent) (in thirteen patients) caused a moderate or severe limp two years postoperatively; however, this complication appears to have been related more to the direct lateral approach that was used than to the prosthesis. Six (13 per cent) of the patients walked with a cane at one year and five (11 per cent) still required a cane at two years. Serial radiographic evaluations revealed that, between the first and second postoperative years, a progressive radiodense femoral line developed in twenty hips (41 per cent); a progressive acetabular line, in four hips (8 per cent); and progressive femoral sclerosis, in twelve hips (24 per cent). There was progressive loosening of beads from twelve (24 per cent) of the femoral components and from nine (18 per cent) of the acetabular components. The position of one acetabular and one femoral component changed. Two femoral shafts fractured, one intraoperatively and one fourteen months postoperatively. We concluded that the clinical results were encouraging in these patients at the end of two years. We are concerned, however, about the progressive radiodense lines, sclerosis, and loosening of beads as well as the slight, but persistent, pain in the thigh in eight patients.

Acetabulum↗

21-year results of the uncemented fully textured lord hip prosthesis.

We report the updated results for a previously evaluated patient cohort who had uncemented total hip arthroplasties using the Lord femoral component. The original cohort consisted of 114 total hip arthroplasties (110 patients) performed from 1979 to 1984. The patients were followed up for an average of 21 years postoperatively. We describe the radiographic findings of 57 hips. At the last followup 11 (9.6%) of the 114 femoral components were revised or removed. Excluding infection there was an 83% 21-year survival according to Kaplan-Meier analysis. No significant radiographic changes occurred since the last publication. The prostheses are very well-fixed with no signs of loosening. Our current findings show the durability of the uncemented Lord femoral component indicating this prosthesis provides good long-term results.

Adult↗

Effect of slide track shape on the wear of ultra-high molecular weight polyethylene in a pin-on-disk wear simulation of total hip prosthesis.

Prosthetic joints appear to show a strong relationship between the type of relative motion and wear, requiring careful consideration in the design of wear simulators. This relationship was studied with a 12-station pin-on-disk device, specifically adapted for the wear simulation of prosthetic hip joints. Each station had a unique motion, characterized by the so-called slide track, the track of the pin on the disk. The slide track shapes included 10 ellipses, their aspect ratio (AR) varying from 1.1 to 11.0, and a circle and a straight line as extreme cases. Hence for the first time in hip wear simulation, the motion was systematically varied over a wide range. Conventional UHMWPE pins were tested against polished CoCr disks in diluted calf serum three times for 3 million cycles. Below the AR value of 5.5, the polyethylene wear factor and wear mechanisms agreed with clinical observations. Above this value, the wear factor decreased to unrealistically low values, and the wear surface topography differed from that of retrieved acetabular cups. The wear particles, however, were similar to those isolated from periprosthetic tissues, irrespective of the AR value. In conclusion, it is recommended that the AR value be kept well below the critical point of 5.5.

Animals↗

Metallosis due to impingement between the socket and the femoral head in a total hip prosthesis. A case report.

Metallosis is usually defined as aseptic fibrosis, local necrosis, or loosening of a device secondary to metallic corrosion and release of wear debris. It is an occasional but characteristic clinical finding in patients who have a metal-on-metal design of total hip replacement, or when metal surfaces contact after a failure or erosion of the polyethylene component. We report the case of a patient who had severe metallosis caused by wear of the femoral head with the titanium socket, after the complete erosion and destruction of the polyethylene cup, with failure of the accetabular component. Breakage of the acetabular cup constitutes one of the possible long-term complications occurring as a result of a total hip replacement. This extremely rare complication can occur at any time postoperatively and may not be associated with symptoms or other problems for a long time.

Aged↗

[Computer-assisted, robot-assisted hip prosthesis--standard procedure or specialty indication?].

Approximately 150,000 total hip replacements annually are performed in Germany, with an increasing incidence of implants carried out on young subjects. Due to aseptic loosening, this group will undergo some revision arthroplasty after 15 years. Therefore, a permanent fixation appears mandatory. In case of posttraumatic or postoperative anatomical changes, exact preoperative planning by x-rays is extremely difficult. This might result in a higher rate of complications (e.g., displacement of the implanted prosthesis, fractures of the proximal femur), as documented by the available literature. The preoperative planning with CT images obtained at the 3D workstation shows the exact cortical situation, while the robot-assisted surgery allows the precise execution of the preoperative plan during surgery. By this point of time, long-term results of computer-guided, robot-assisted implantation of endoprosthesic devices are still lacking. However, the preliminary data indicate good results by means of anatomical position of the endoprosthesis and perioperative complications.

Arthroplasty, Replacement, Hip↗

[Cementless hip prosthesis design: a basic study and analysis of the proximal femur in normal Japanese people].

Using CT images the proximal part of 50 femora was morphologically analysed in 28 normal Japanese adults. The purpose was to determine the normal stem size and shape in order to manufacture an artificial hip joint. The results were as follows: 1) The periosteal shape and the size of the normal femur were proportional. 2) The endosteal shape and the size of the normal femur were less proportional than the periosteal shape and size. 3) The endosteal width 20 mm distal from the lesser trochanter of the normal femur was 18.2 +/- 2.7 mm. 4) The femoral head offset of the normal femur was 41.8 +/- 4.8 mm. 5) The taper angle was 4.9 degrees on average, but the tapering of the proximal medullary canal was different from the tapering of the distal medullary canal.

Adolescent↗

[A study of the mechanical properties of alumina-on-alumina total hip prosthesis (author's transl)].

The authors describe the results obtained between 1970 and 1980 (more than 1205 cases) with an original prosthesis made of alumina (aluminium oxide) for the frictional torque. In the first stage some failures were encountered due to disruptures between the ball and the stem. A new type of union was designed in which the ball is peroperatively placed on a titanium alloy stem by conical fixation. This ceramic material exhibits a very low friction, negligible wear and excellent biocompatibility. These prosthesis can be inserted with or without cement.

Aged↗