PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Particle Size”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34Linked to original sources

Genetic heterogeneity of plasma lipoproteins in the mouse: control of low density lipoprotein particle sizes by genetic factors.

In order to assess the genetic control of sizes and concentrations of mouse plasma low density (LDL) and high density lipoproteins (HDL), we used gel permeation fast protein liquid chromatography (FPLC) and nondenaturing gradient polyacrylamide gel electrophoresis to measure the particle sizes of LDL and HDL. Using chromatography we also quantified LDL-cholesterol and HDL-cholesterol concentrations in plasma and used them as indexes of plasma concentrations of the respective particles among 10 inbred strains (AKR/J, BALB/cByJ, C3H/HeJ, C57BL/6J, C57BL/6ByJ, C57L/J, DBA/1LacJ, 129/J, NZB/BINJ, SWR/J) and three sets of recombinant inbred (RI) strains (AKXL/TyJ, BXH/TyJ, CXB/ByJ) of mice. HDL had a dichotomous distribution among the 10 inbred strains. One group had large HDL particle sizes and high HDL-cholesterol concentrations. Another group had smaller HDL particles and lower HDL-cholesterol concentrations, and HDL sizes and HDL-cholesterol concentrations were significantly correlated. In the RI strains, HDL sizes and HDL-cholesterol cholesterol concentrations clearly segregated with one or another of the progenitor strains, and RI strain distributions showed a strong linkage to the apolipoprotein (apo) A-II gene (Apoa-2). In contrast, LDL-cholesterol concentrations and particle sizes on FPLC did not show dichotomous distributions among the 10 inbred strains. In RI strains, the configuration of the LDL FPLC profiles and LDL-cholesterol concentrations did resemble one or another of the progenitors in the majority of cases, but LDLs of several RI strains resembled neither progenitor strain in profile configuration, and LDL-cholesterol concentrations were both greater and smaller than those of progenitor strains. However, LDL particle diameters (as judged by peaks of LDL-cholesterol profiles) did segregate with progenitors in 29/33 (88%) of RI strains suggesting that a major gene may affect LDL size. In attempting to identify a major LDL-size determining gene, we compared apoB gene restriction fragment length polymorphisms (RFLPs) to the distributions of peak LDL sizes in RI strains. Concordance rates of peak LDL sizes to apoB gene polymorphisms were 18/22 (82%) for the EcoRV RFLP, 5/7 (71%) for HindIII RFLP, and 23/29 (79%) for both (range of P values 0.90-0.95). Thus we could not unequivocally implicate the apoB gene in determining the size of LDL particles. In summary, the genetic control of LDL sizes is more complicated than is the case for HDL; however, the differences in LDL size among these strains of mice may be controlled by a major, as yet unidentified, gene.

Animals↗

Mass transfer rates of polycyclic aromatic hydrocarbons between micron-size particles and their environment--theoretical estimates.

This paper presents a mathematical model of how rapidly polycyclic aromatic hydrocarbons (PAHs) adsorb onto initially clean micron-size particles in the ambient air and how fast these substances are likely to be desorbed from the particles after deposition on the surface lining layer of the lung. Results show that, on the one hand, the very low gas-phase concentrations of PAHs in the ambient air should result in a comparatively slow transfer of such compounds to micron-size particles, a process that may last from minutes to hours. On the other hand, the comparatively high solubilities of PAHs in the lining layer of the lung should promote an almost instantaneous release of PAHs onto nonporous particles, and a release within a matter of minutes of most PAHs reversibly adsorbed onto the interior surfaces of porous particles. Two important conclusions can be drawn from this. First, the PAHs in tobacco smoke do not have time enough to interact in the gas phase with other airborne particles before these agents are inhaled into the smoker's lungs. Therefore, adsorption in the gas phase of PAHs onto asbestos fibers can hardly be a characteristic parameter in the mechanism behind the synergistic effect between tobacco smoking and asbestos exposure for the induction of bronchial cancer. Second, the release rate of reversibly adsorbed PAHs from their carrier particles in the lung seems to be so fast that this cannot be a parameter of importance in directly influencing the residence times of such substances in the lung.

Adsorption↗

Effect of Particle Size on Rate of Coalescence of Silica Nanoparticles.

In high temperature processes, at high concentrations, aerosol particles grow by collisions and coalescence. The rate of coalescence is an important parameter for predicting the final primary particle size. For some materials, particularly silica, predictions of final primary particle size using coalescence rates based upon bulk material properties are not in agreement with experimental results. One explanation may be that the high internal pressure in very small particles (less than 10 nm in diameter) affects the mobility of material within the particles and hence the coalescence rate. In this Note, a new approach for estimating rates of coalescence of particles in the initial stages of growth is presented. Coalescence of liquid particles is assumed to be rate-limited by atomic mobility, and the effect of internal pressure on diffusivity is considered. Copyright 1999 Academic Press.

Journal Article↗

Aerosols of mycoplasmas, L forms, and bacteria: comparison of particle size, viability, and lethality of ultraviolet radiation.

Aerosols of microorganisms were tested for particle size by use of an Andersen sampler. Mycoplasma aerosols had an average count median diameter (CMD) of 2.1 +/- 0.5 mu. Staphylococcus aureus L forms gave an average CMD of 4.6 +/- 1.7 mu; the diphtheroid L form, a CMD of 3.4 +/- 0.3 mu. Escherichia coli had a CMD of 5.4 +/- 2.5 mu; Neisseria sicca, 3.3 +/- 0.5 mu; N. meningitidis, 3.4 +/- 0.2 mu. S. aureus ATCC 6538, the parent strain of the L form, yielded a CMD of 3.9 +/- 1.2 mu. Candida albicans gave an average CMD of 5.9 +/- 1.4 mu. All organisms tested survived aerosolizing and could be recovered in viable form for at least 1 hr. Ultraviolet radiation at 2,537 A destroyed the bacteria and mycoplasmas instantaneously, and destroyed 87% of the L forms of S. aureus, 69% of the diphtheroid L form, and 98% of the C. albicans cells. After irradiation, viable particles of the L form and C. albicans aerosols were consistently larger, indicating that clumping led to survival. Submicron size particles were found in aerosols of all species tested except C. albicans.

Aerosols↗

Effects of dose and particle size on activated carbon treatment to sequester polychlorinated biphenyls and polycyclic aromatic hydrocarbons in marine sediments.

Recent laboratory studies show that mixing activated carbon with contaminated sediment reduces the chemical and biological availability of hydrophobic organic contaminants. In this study, we test the effects of varying the activated carbon dose and particle size in reducing the aqueous availability of polychlorinated biphenyls (PCBs) and polycyclic aromatic hydrocarbons (PAHs) and the uptake of PCBs by two benthic organisms. We mixed PCB- and PAH-contaminated sediment from Hunters Point Naval Shipyard, San Francisco Bay (CA, USA), for one month with activated carbon, at doses of 0.34, 1.7, and 3.4% dry mass basis. We found that increasing the carbon dose increased the effectiveness in reducing PCB bioaccumulation. In 56-d uptake tests with the benthic organisms Neanthes arenaceodentata and Leptocheirus plumulosus, PCB bioaccumulation was reduced by 93 and 90%, respectively, with 3.4% carbon. Increasing the dose also increased the effectiveness in reducing PCB and PAH aqueous concentrations and uptake by semipermeable membrane devices and quiescent flux of PCBs to overlying water. Decreasing activated carbon particle size increased treatment effectiveness in reducing PCB aqueous concentration, and larger-sized activated carbon (400-1,700 microm) was ineffective with a contact period of one month. We invoke a numerical model based on intraparticle diffusion in sediment and activated carbon particles to help interpret our experimental results. This model was useful in explaining the trends for the effect of activated carbon dose and particle size on PCB aqueous concentrations in well-mixed systems.

Carbon↗

Content and distribution of forms of organic N in soil and particle size fractions after long-term fertilization.

Most of the N in surface soils occurs in organic forms, and when mineralized it plays a key role in soil fertility and plant nutrition. Our objective was to study the effect of long-term applications of organic manure on the content and distribution of forms of organic N in bulk soil and soil particle size fractions to characterize the inherent soil nitrogen fertility. Five treatments were as follows: (1) CK (no fertilizer and no manure added), (2) mineral fertilizer only, (3) straw + NPK, (4) green manure + NPK and (5) pig manure + NPK. Soil particle size fractions (0-2, 2-10, 10-50 and 50-100 microm) were isolated without chemical pretreatment by ultrasonic dispersion in water followed by sedimentation. The content of total N and forms of organic N in the bulk soil increased after long-term fertilization, and the effect varied with fertilizer type. The plot treated with only mineral fertilizer gave the highest NH3-N and the lowest amino sugar-N content in all treatments. The highest content of amino sugar-N and amino acid-N was found in the treatment of pig manure + NPK. The content (g kg(-1) fraction) of hydrolysable N within size fractions was in the order 0-2 > 2-10 > 50-100 > 10-50 microm, but the contribution of different size fraction to hydrolysable N decreased in the sequence 10-50 > 0-2 > 2-10 > 50-100 microm. Most of the applied mineral fertilizer N that remained in soils was distributed in the particle size fraction < 2 microm while most of the remaining N from manure applied with NPK was transferred into amino sugar-N in each size fraction, and amino acid-N in the size fractions > 2 microm during the process of humification.

Fertilizers↗

Sorption of pyrene on two paddy soils and their particle-size fractions.

In the present study, the sorption of pyrene on two kinds of bulk paddy soils, Gleyic Stagnic Anthrosols, and Ferric accumulic Stagnic Anthrosols as well as their particle-size fractions was investigated. The sorption isotherms fitted well with Freundlich equation. For both soils, the clay fraction( < 2 microm) and coarse sand fraction(2000-250 microm) had higher sorption capacity than fine sand fraction(250-20 microm) and silt fraction(20-2 microm). The log Koc values obtained of each soil and its particle-size fractions were similar, proving that SOM content was a key factor affecting pyrene sorption. The Kd values showed a significant correlation with contents of dithionite-extractable Fe in both paddy soils and a good relationship with CEC in Gleyic Stagnic Anthrosols, indicating possible effects of surface properties of particle-size fractions on the sorption of pyrene.

Adsorption↗

Technegas and Pertechnegas particle size distribution.

Technegas and Pertechnegas are radioactive aerosols produced in a commercial generator and used for lung scintigraphy. The aerosols are produced by first evaporating to dryness standard technetium-99m generator eluate (99mTcO4 in normal saline) in a graphite crucible (the simmer stage) and then heating this to 2500 degrees C (the "burn" stage). The aim of this work was to measure the particle size distributions of these agents and relate this to regional lung deposition. Factors that may vary during production of the aerosol in routine use were investigated to determine whether they influenced the particle size. Activity size distributions were measured using a serial wire-screen diffusion battery. The Technegas size distribution was approximately log-normal with an activity median diameter of 158 nm and a geometric standard deviation of 1.5. The results for Pertechnegas were similar. The median size increased with the number of simmers and with the time from generation. The increase in size with the number of simmers is thought to be due to the increased salt content in the crucible prior to the "burn". The predicted lung deposition is 37% in the alveolar region and 5% in the bronchial region. Significant changes in deposition are not predicted over the range of particle sizes measured.

Aerosols↗

Tableting of coated particles. I. Small particle size chitosan as an agent protecting coating membrane from mechanical damage of compression force.

Formulation of sustained release tablets containing coated particles whose coating membrane is not damaged during compression was studied and several kinds of chitosan of different particle size were evaluated as protective agents for the membrane. Comparison was made with the dissolution rate of the coated particles. Ethylcellulose or ethylcellulose/hydroxypropylcellulose was chosen as a coating agent. When the coated particles were compressed with the small particle size chitosan (Marine Chito), the coating membrane was not ruptured, and the protective effect was not influenced by the compression pressure. Both the Eudragit RS-coated particles and the tablets manufactured by compressing the coated particles with Marine Chito were orally administered to dogs, and the plasma theophylline levels of the two dosage forms were compared to determine the drug release characteristics in the gastrointestinal tract. It was found that the plasma concentration-time curve of the tablets coincided with that of the coated particles, and the compressed tablet would disintegrate instantly and redisperse into many particles in the body after oral administration.

Animals↗

Effect of particle size on ophthalmic bioavailability of dexamethasone suspensions in rabbits.

Three suspensions of 0.1% [3H]dexamethasone were prepared with mean particle sizes of 5.75, 11.5, and 22.0 micron. The suspensions were dosed topically to the right eyes of rabbits. Their bioavailability was compared by measuring aqueous humor and corneal levels over 5 hr. A statistically significant rank-order correlation was observed between increasing drug levels and decreasing particle size.

Animals↗

Mucosal insulin delivery systems based on complexation polymer hydrogels: effect of particle size on insulin enteral absorption.

Insulin-loaded polymer (ILP) microparticles composed of poly(methacrylic acid) and poly(ethylene glycol), which have pH-dependent complexation and mucoadhesive properties have been thought to be potential carriers for insulin via an oral route. Nevertheless, further optimization of the polymer delivery system is required to improve clinical application. Therefore, the effect of particle size of the ILP (L-ILP: 180-230 microm, S-ILP: 43-89 microm, SS-ILP: <43 microm) on insulin absorption was studied in the in situ loop system, hypothesizing smaller particle sizes of ILP could induce bigger hypoglycemic effects due to increase mucoadhesive capacity. To verify the hypothesis, the adhesive capacities of differently sized ILPs to the mucosal tissues were evaluated. Additionally, the intestinal site-specificity of ILP for insulin absorption was investigated. Intra- and inter-cellular integrity and/or damage were also examined by lactate dehydrogenase leakage and membrane electrical resistance change to ensure the safety of ILP as a carrier for oral route. As hypothesized, the smaller sized microparticles (SS-ILP) showed a rapid burst-type insulin release and higher insulin absorption compared with the microparticles having larger sizes, resulting in greater hypoglycemic effects without detectable mucosal damage. In fact, SS-ILP demonstrated higher mucoadhesive capacity to the jejunum and the ileum than those of L-ILP. Moreover, SS-ILP's enhancement effect of insulin mucosal absorption showed a site-specificity, demonstrating maximum effect at the ileal segment. These results imply that the particle size and delivery site are very important factors for ILP with respect to increasing the bioavailability of insulin following oral administration.

Animals↗

Feed intake and digestion by beef steers consuming and receiving ruminal insertions of prairie hay differing in level and particle size.

A 5 X 5 Latin square design involving five cannulated beef steers (342 and 358 kg avg initial and final body weights, respectively) fed prairie hay (76.7% neutral detergent fiber, 5.7% acid detergent lignin and .85% N) was conducted to evaluate effects on feed intake and nutrient digestion of variations in physical characteristics of ruminal digesta achieved by ruminal insertion of different amounts of prairie hay differing in particle size. Steers were fed hay ad libitum in two equal meals (0800 and 2000). At 1200, four of the steers received manual, ruminal insertions of ground hay. Fine hay (F) was ground through a screen with 2-mm openings (.39 mm mean particle size), whereas coarse hay (C) was ground through a screen with 2.54-cm openings (4.46 mm mean particle size). Amounts of hay inserted were .2 (low, L) or .4% (high, H of initial body weight of individual steers. Ruminal hay insertions comprised 18% of total dry matter (DM) intake for L and 34 and 37% for HF and HC, respectively. Fed hay consumption decreased (P less than .05) with hay insertion and was lower for H than L; total DM intake was not influenced by treatment (P greater than .10). Ruminal NH3-N concentrations and ruminal organic matter digestion was greater (P less than .05) with ruminal hay insertion than without and with H than with L (P less than .05).(ABSTRACT TRUNCATED AT 250 WORDS)

Animal Feed↗

Particle size reduction of alfalfa silage did not alter nutritional quality of high forage diets for dairy cattle.

Twelve multiparous, lactating Holsteins were fed an energy adequate diet (50% wilted alfalfa silage) and two isonitrogenous diets containing 80% of the same silage. The two 80% alfalfa diets were identical in all respects except that for one diet 38% of the alfalfa silage was rechopped after fermentation to reduce the particle length from 5.63 to 3.12 mm. Feeding the 80% alfalfa diets decreased milk production due to limitation of digestible energy intake. Under conditions of energy restriction, reduction of particle size of alfalfa silage after fermentation did not result in any changes in feed intake, feed digestibility, or milk production. The results do not preclude the possibility of some changes for intake or digestibility with more extensive reductions in particle length of alfalfa silage. However, because the extent of forage particle size reduction is limited by nutritional and economic constraints, the results of this study indicate that there is no practical advantage to reducing the particle size of fermented alfalfa beyond that required for adequate fermentation.

Animal Feed↗

Stealth PEG-PHDCA niosomes: effects of chain length of PEG and particle size on niosomes surface properties, in vitro drug release, phagocytic uptake, in vivo pharmacokinetics and antitumor activity.

A series of novel niosomes with the amphiphilic copolymer of poly (methoxy-polyethyleneglycol cyanoacrylate-co-n-hexadecyl cyanoacrylate) (PEG-PHDCA) acted as surface modification materials were prepared and Hydroxycamptothecin (HCPT) was used as a model drug. This work concentrated on the effects of PEG chain length and particle sizes on the niosomes surface properties, in vitro drug release, phagocytic uptake, in vivo pharmacokinetics and antitumor activity. Within the range of PEG Mw from 2000 to 10000, the increasing zeta potential (from -16.08 to -5.25 mv) and thicker fixed aqueous layer (3.82 to 5.78 nm) would facilitate the niosomes' stealth effects, while the reduced PEG chain density (from 0.53 to 0.17 PEG/nm2) and the quickened speed of drug release would diminish the effects. As a result, the PEG5000-PHDCA niosomes had the least phagocytic uptake, the longest half-life of 11.46 h and the best tumor inhibition rate of 97.1%. In the groups different in particle size (PEG5000-PHDCA niosomes from 92.5 to 204.6 nm), the bigger particles could be uptaken by macrophages more quickly, regardless of the changes of other physicochemical parameters. Correspondingly, PEG5000-PHDCA niosomes with particle sizes of 92.5, 144.2, 204.6 nm could extend the half-life of HCPT to 11.46, 6.33, 4.46 h, respectively. At last, the tumor inhibition rate of PEG5000-PHDCA niosomes (92.5 nm) at a dose of 2 mg/kg was five times that of HCPT injection at 4 mg/kg. The stealth effects of the PEG-PHDCA niosomes and the enhanced stability of lactone form of HCPT were accountable for the powerful antitumor effects of niosomes.

Algorithms↗

Hydroxyapatite-polyethylene composites for bone substitution: effects of ceramic particle size and morphology.

Synthetic hydroxyapatite particles of two median sizes and different morphologies have been used to manufacture hydroxyapatite reinforced high density polyethylene composites (HAPEX) for medical applications. The effects of hydroxyapatite particle size on properties of the resultant composites were investigated using various techniques. It was found that composites with smaller hydroxyapatite particles had higher torsional modulus, tensile modulus and tensile strength, but lower strain to failure. Examination of fracture surfaces revealed that only a mechanical bond existed between the filler and the matrix. It was shown that dynamic mechanical analysis is useful in studying the viscoelastic behaviour of the composite.

Bone Substitutes↗

Correction to Microscopically Determined Particle Size According to Diffraction Correction Theory.

The theory of diffraction correction for transparent (phase) spherical particles under partially coherent illumination has been applied to the optical photomicrographic determination of particle size distribution for four different nearly monodisperse polystyrene latex samples. The thus corrected particle size distribution for each sample has been compared with the corresponding electron microscopic determination. Copyright 1999 Academic Press.

Journal Article↗

Low-density lipoprotein particle size is not a discriminating marker for atherogenic risk in male offspring of parents with early coronary artery disease.

The aim of this study was to assess the importance of low-density lipoprotein (LDL) particle size as a marker of atherogenic risk in male offspring of a parent with early coronary artery disease (CAD) before the age of 60 years. CAD-positive (CAD+) offspring were recruited into two groups based on age, 15 to 30 years (n = 20) and 31 to 45 years (n = 41), and matched to CAD-negative (CAD-) offspring by age and body mass index (BMI) (n = 20 and 21 per group). LDL peak particle diameter was assessed by polyacrylamide gradient gel electrophoresis. There was no significant difference in LDL peak particle diameter between CAD+ and CAD- offspring (26.2 +/- 0.1 v 26.2 +/- 0.1 nm, mean +/- SE). There was also no difference between CAD+ offspring and CAD- offspring when comparisons were made within their own age group (26.5 +/- 0.1 nm in younger CAD+ offspring v 26.2 +/- 0.1 nm in younger CAD- offspring, and 26.0 +/- 0.1 nm in older CAD+ offspring v 26.1 +/- 0.2 nm in older CAD- offspring). Peak particle diameter was significantly greater in younger CAD+ offspring than in older CAD+ offspring (26.5 +/- 0.1 v 26.0 +/- 0.1 nm, P < .05). We conclude that small LDL particle size is not a discriminating marker for early atherogenic risk, and that measurement of LDL particle size has limited value in the assessment of coronary risk, at least in the age ranges we studied.

Adolescent↗