PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Power”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34Linked to original sources

Determinants of maximal cycling power: crank length, pedaling rate and pedal speed.

The purpose of this investigation was to determine the effects of cycle crank length on maximum cycling power, optimal pedaling rate, and optimal pedal speed, and to determine the optimal crank length to leg length ratio for maximal power production. Trained cyclists (n = 16) performed maximal inertial load cycle ergometry using crank lengths of 120, 145, 170, 195, and 220 mm. Maximum power ranged from a low of 1149 (20) W for the 220-mm cranks to a high of 1194 (21) W for the 145-mm cranks. Power produced with the 145- and 170-mm cranks was significantly (P < 0.05) greater than that produced with the 120- and 220-mm cranks. The optimal pedaling rate decreased significantly with increasing crank length, from 136 rpm for the 120-mm cranks to 110 rpm for the 220-mm cranks. Conversely, optimal pedal speed increased significantly with increasing crank length, from 1.71 m/s for the 120-mm cranks to 2.53 m/s for the 220-mm cranks. The crank length to leg length and crank length to tibia length ratios accounted for 20.5% and 21.1% of the variability in maximum power, respectively. The optimal crank length was 20% of leg length or 41% of tibia length. These data suggest that pedal speed (which constrains muscle shortening velocity) and pedaling rate (which affects muscle excitation state) exert distinct effects that influence muscular power during cycling. Even though maximum cycling power was significantly affected by crank length, use of the standard 170-mm length cranks should not substantially compromise maximum power in most adults.

Adult↗

Mechanical power and efficiency in running children.

The effect of age and body size on the total mechanical power output (Wtot) during running was studied in children of 3-12 years of age and in adults. Wtot was measured as the sum of the power required to move the body's centre-of-mass relative to the surroundings (the "external power", Wext) plus the power required to move the limbs relative to the body's centre-of-mass (the "internal power", Wint). At low and intermediate speeds (less than about 13 km h-1) the higher step frequency used by young children resulted in a decrease of up to 40-50% in the mass-specific external power and an equal increase in the mass-specific internal power relative to adults. Due to this crossed effect, the mass-specific Wtot is nearly independent of age. At high speeds the mass-specific Wtot is 20-30% larger in young children than in adults, due to a greater forward deceleration of the centre-of-mass at each step. The efficiency of positive work production, calculated as the positive mechanical power divided by the net energy consumption rate, appears to be similar in children and adults (i.e. 0.40-0.55).

Adult↗

Different methods to estimate total power and its components during lifting.

A more fundamental understanding about the act of manual lifting can be provided by the assessment of the total production of power and the power generated in joints. The present study is concerned with the validity of the estimations of these parameters. Four subjects lifted an 18.8 kg load while they were filmed and ground reaction forces were measured. The total generated power was calculated in three ways: (1) by summation of joint powers, (2) on the basis of the rate of change of the summed energy contents of human body segments, and (3) on the basis of the rate of change of the body energy estimated from ground reaction forces. The results were compared. Furthermore, at a segmental level the power supplied to or absorbed from a segment was compared to the rate of change of its energy content. The resulting instantaneous power curves from the three different methods showed a high level of agreement, which supports their validity. However, some minor discrepancies were observed. The major cause of the observed difference between the rate of change of the summed segmental energy contents and the summed joint powers was found at a segmental level. It was observed that segmental link lengths (i.e. distances between proximal and distal markers) changed during movement, which yielded discrepancies between the power flow to or from a segment and the rate of change of its energy content.

Adult↗

A power equation for the sprint in speed skating.

An analysis of the start of the 500 m speed skating races during the 1988 Olympic Winter Games showed a remarkably high correlation between the acceleration of the skater in the first second of the sprint and the final time (r = -0.75). In this study a power equation is used to explain this high coefficient of correlation. The performance in speed skating is determined by the capability of external power production by the speed skater. This power is necessary to overcome the air and ice friction and to increase the kinetic energy of the skater. Numerical values of the power dissipated to air and ice friction, both dependent on speed, are obtained from ice friction and wind tunnel experiments. Using aerobic and anaerobic power production as measured during supra maximal bicycle tests of international-level speed skaters, a model of the kinetics of power production is obtained. Simulation of power production and power dissipation yields values of speed and acceleration and, finally, the performance time of the sprint during speed skating. The mean split time at 100 m and the final time at 500 m in these races, derived from simulation, were 10.57 s (+/- 0.31) and 37.82 s (+/- 0.96), respectively. The coefficient of correlation between the simulated 500 m times and the actual 500 m times was 0.90. From the results of this study it can be concluded that the distribution of the available anaerobic energy is an important factor in the short lasting events. For the same amount of anaerobic energy the better sprinters appear to be able to liberate considerably more energy at the onset of the race than skaters of lower performance level.

Biomechanical Phenomena↗

Noise and signal power and their effects on evoked potential estimation.

Signal power, noise power and their ratio (SNR) are important variables underlying estimation of evoked potential signals, yet, they are rarely explicitly considered in the design or analysis of EP experiments. A model is developed which relates the reliability of the average evoked potential (AEP) wave form to signal power, noise power, SNR, and the number of single trials included in the average. Measurements taken from auditory and visual EP experiments in elderly subjects show that noise power is highly reliable across experimental conditions and probably reflects global CNS anatomic or physiologic factors. In contrast, signal power and SNR are variable across conditions and sensory modalities, but are stable across replications. Thus signal power reflects CNS processes specific to the experimental paradigm. These results have importance for EP estimation. The expected reliability of the AEP cannot be adequately predicted from estimates of a subject's noise power, or from SNR estimated under different experimental conditions. These findings suggest the need for on-line estimation of SNR during data acquisition to ensure adequate reliability of AEPs.

Aged↗

Changes in ultrasonic Doppler backscattered power downstream of concentric and eccentric stenoses under pulsatile flow.

The main objective of the present work was to investigate, under pulsatile flow, the patterns of variation of the Doppler power backscattered by blood and Sephadex particles upstream and downstream of concentric and eccentric stenoses ranging from 47% to 91% area reduction. Doppler measurements were performed at 5 diameters upstream and 5, 10, 15 and 20 diameters downstream of the constriction. For the concentric 75% and 85%, and the eccentric 79% and 91% area reduction stenoses, a progressive increase of the power backscattered by red cell suspensions at 40% hematocrit was measured downstream of the narrowing. The maximal power usually occurred around 10 diameters after the stenosis and dropped further downstream. In addition to the increase in the power, a cyclic variation of the backscattered intensity was observed within the flow cycle. For the concentric 52% and eccentric 47% area reduction stenoses, no variation of the Doppler power was measured during flow acceleration and deceleration for all recording sites. A coefficient of correlation of 0.82 was measured between the percentage of area reduction and the ratio of the Doppler mean power at 10 diameters downstream to that at 5 diameters upstream of the stenoses. Using Sephadex particles at low concentration, no increase of the Doppler power was found downstream of the 85% and 91% area reduction stenoses. The possible link between the intensity of turbulence and the power backscattered by blood is discussed along with the influence of the correlation between the scattering particles, under turbulent flow.

Acceleration↗

Power spectral analysis of heart period variability in hypertensive patients with left ventricular hypertrophy.

This study aimed to characterize sympathovagal balance by heart period power spectrum analysis in hypertensive patients with echocardiographic evidence of left ventricular hypertrophy. Twenty ambulatory patients (11 men and 9 women), aged 50 +/- 10 years, with established essential hypertension and echocardiographic left ventricular hypertrophy, performed 24-h blood pressure monitoring and electrocardiogram Holter recording on 2 consecutive days. Twenty age- and sex-matched normal subjects comprised the control group. Power spectrum analysis, performed using the fast Fourier transform algorithm, demonstrated lower values of low and high frequency power in hypertensives than in controls, while ultralow and very low frequency power were similar in the two groups. Very low frequency, low frequency, and high frequency power increased during the night in both groups, showing a similar circadian pattern. We found a direct correlation between daytime systolic (r = 0.51; P < .05) and diastolic (r = 0.52; P < .05) blood pressure and left ventricular mass index. Moreover, negative correlations were found between left ventricular mass index and low frequency (r = -0.47; P < .05) and high frequency power (r = -0.47; P < .05). There was a direct correlation between nighttime decrease in systolic blood pressure and nighttime increase in high frequency power (r = 0.45; P < .05). As 24-h low frequency and high frequency power, obtained using the Fourier transform algorithm, both reflect the parasympathetic modulation of heart rate, our results demonstrate that hypertensive patients with left ventricular hypertrophy are characterized by a sympathovagal imbalance with a reduction of vagal tone that is more evident with increasing severity of hypertension.

Blood Pressure↗

Comparison of 2-dimensional and 3-dimensional power-Doppler imaging in complex adnexal masses for the prediction of ovarian cancer.

OBJECTIVE: The purpose of this study was to compare 2-dimensional and 3-dimensional power-Doppler imaging diagnostic performance for the prediction of ovarian cancer in complex adnexal masses. STUDY DESIGN: Sixty-nine complex adnexal masses in 60 women (mean age, 48.4 years [range, 17-82 years]) were evaluated by 2-dimensional and 3-dimensional power-Doppler imaging for differentiating benign from malignant masses. Complex adnexal mass was defined in the presence of at least 1 of the following features: solid areas, thick papillary projections, thick septa, or purely solid echogenicity. One examiner performed 2-dimensional power-Doppler imaging, and a second examiner performed 3-dimensional power-Doppler imaging. All masses were removed surgically, and definitive diagnosis was obtained. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were calculated for both techniques. RESULTS: Forty-five tumors (65.2%) were proved to be malignant, and 24 tumors (34.8%) were proved to be benign. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for 2-dimensional power-Doppler imaging were 97.8%, 87.5%, 93.6%, 95.5%, and 94.2%, respectively. Sensitivity, specificity, positive predictive value, negative predictive value, and accuracy for 3-dimensional power-Doppler imaging were 97.8%, 79.2%, 89.9%, 95%, and 91.3 % respectively. There were no statistical differences in sensitivity and specificity (McNemar test: P = .250) CONCLUSION: Three-dimensional power-Doppler imaging did not have a better diagnostic performance than 2-dimensional power-Doppler imaging for the discrimination of benign from malignant complex adnexal masses.

Adnexa Uteri↗

Understanding statistical power in the context of applied research.

Estimates of statistical power are widely used in applied research for purposes such as sample size calculations. This paper reviews the benefits of power and sample size estimation and considers several problems with the use of power calculations in applied research that result from misunderstandings or misapplications of statistical power. These problems include the use of retrospective power calculations and standardized measures of effect size. Methods of increasing the power of proposed research that do not involve merely increasing sample size (such as reduction in measurement error, increasing 'dose' of the independent variable and optimizing the design) are noted. It is concluded that applied researchers should consider a broader range of factors (other than sample size) that influence statistical power, and that the use of standardized measures of effect size should be avoided (except as intermediate stages in prospective power or sample size calculations).

Research↗

The effect of walking speed on lower-extremity joint powers among elderly adults who exhibit low physical performance.

OBJECTIVES: To compare peak joint powers and joint angles between comfortable and fast walking speeds among a group of elderly adults who exhibit low physical performance, and to test the primary hypothesis that peak ankle powers would not change when walking speed was increased, but that peak hip power output would increase significantly with speed. DESIGN: Three-dimensional analysis of joint kinematics and kinetics during comfortable and fast walking by both healthy and low-performing elderly adults (age, >70y). SETTING: Gait laboratory. PARTICIPANTS: Twenty-four healthy elderly adults and 27 elders who exhibited low performance on a standard battery of walking, standing balance, and chair-rise tasks that places them at risk of mobility-related disability. INTERVENTIONS: Not applicable. MAIN OUTCOME MEASURES: Peak lower-extremity joint powers and joint angles. RESULTS: Low-performing elders increased both ankle and hip power outputs to increase walking speed. However, peak ankle power remained significantly below that of the healthy elderly adults even when the low-performing elders walked at a faster gait speed. Joint-power changes in the low-performing elderly were accompanied by a reduction in hip extension and ankle dorsiflexion, and an increase in transverse pelvic rotation. CONCLUSIONS: Compared with healthy elderly, the low-performing elderly adults showed speed-independent differences in ankle and hip mechanics that may reflect underlying neuromuscular impairments. In particular, an understanding of the interdependent contributions of hip flexibility and ankle power limitations seem important to inform interventions to maintain gait into advanced age.

Aged↗

Manual punch versus power harvesting of osteochondral grafts.

PURPOSE: The purpose of the study was to analyze the effect on chondrocyte viability of 2 existing methods of harvesting osteochondral grafts used for articular cartilage resurfacing. TYPE OF STUDY: Acute animal experiment. METHODS: Power (P) trephine versus manual (M) punch harvesting was tested; 2.7-mm and 4.5-mm dowels were harvested from 8 femoral trochlea from 4 sheep using the Acufex MosaicPlasty system (Andover, MA). Grafts were harvested perpendicular to the articular surface to a depth of 10 mm under constant saline irrigation. Power trephine grafts (n = 46, 2.7 P; n = 45, 4.5 P) were harvested by coupling the serrated trephine to a standard orthopaedic nitrogen powered drill. Manual punch grafts (n = 41, 2.7 M; n=33, 4.5 M) were harvested by malleting the punch to the required depth, minimizing rocking, and only slightly turning the punch on removal. Five 40-microm-thick fresh cartilage sections oriented perpendicular to the articular surface were obtained from each graft and then stained with Syto 13 and ethidium bromide vital stains, and the proportion of live cells per field and physical damage were compared between groups. Masson's trichrome stain was used on paraffin-embedded histologic sections. RESULTS: Power harvesting was technically more difficult and resulted in more gross and light microscopic damage to the osteochondral grafts. Chondrocyte viability was significantly greater for manual punch versus power harvesting of both graft sizes (P <.005). Chondrocyte viability was greater for 4.5 P versus 2.7 P grafts (P <.005), but no difference was found between the 2.7 M and 4.5 M groups (P =.357). CONCLUSIONS: Chondrocyte viability is significantly greater using manual punch versus serrated power trephines when harvesting osteochondral grafts for cartilage resurfacing procedures. Power trephines should not be used for this procedure. CLINICAL RELEVANCE: This study shows that the original method (power trephine) of harvesting osteochondral grafts results in great loss of chondrocyte viability versus manual punch harvesting and should no longer be used.

Animals↗

In vitro estimates of power output by epaxial muscle during feeding in largemouth bass.

Recent work has employed video and sonometric analysis combined with hydrodynamic modeling to estimate power output by the feeding musculature of largemouth bass in feeding trials. The result was an estimate of approximately 69 W kg(-1) of power by the epaxial muscle during maximal feeding strikes. The present study employed in vitro measurements of force, work and power output by fast-twitch epaxial muscle bundles stimulated under activation conditions measured in vivo to evaluate the power output results of the feeding experiments. Isolated muscle bundles from the epaxial muscle, the sternohyoideus and the lateral red or slow-twitch muscle were tied into a muscle mechanics apparatus, and contractile properties during tetanic contractions and maximum shortening velocity (Vmax) were determined. For the epaxial muscles, work and power output during feeding events was determined by employing mean stimulation conditions derived from a select set of maximal feeding trials: 17% muscle shortening at 3.6 muscle lengths/s, with activation occurring 5 ms before the onset of shortening. Epaxial and sternohyoideus muscle displayed similar contractile properties, and both were considerably faster (Vmax approximately 11-13 ML s(-1)) than red muscle (Vmax approximately 5 ML s(-1)). Epaxial muscle stimulated under in vivo activation conditions generated approximately 60 W kg(-1) with a 17% strain and approximately 86 W kg(-1) with a 12% strain. These values are close to those estimated by hydrodynamic modeling. The short lag time (5 ms) between muscle activation and muscle shortening is apparently a limiting parameter during feeding strikes, with maximum power found at an offset of 15-20 ms. Further, feeding strikes employing a faster shortening velocity generated significantly higher power output. Power production during feeding strikes appears to be limited by the need for fast onset of movement and the hydrodynamic resistance to buccal expansion.

Animals↗

Changes in keratometric corneal power and refractive error after laser thermal keratoplasty.

PURPOSE: To evaluate the effect of laser thermal keratoplasty (LTK) on corneal power and refractive error to develop a logical approach to calculating accurate intraocular lens (IOL) power for cataract surgery. SETTING: Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea. METHODS: Laser thermal keratoplasty was performed in 27 eyes of 23 patients. Preoperatively and postoperatively, the refractive error was measured and the corneal power obtained by manual keratometry and topography. The changes in keratometric corneal power and refractive error after LTK were compared. RESULTS: The mean age of the 15 women and 8 men was 45.0 years +/- 4.6 (SD) (range 43 to 61 years). The mean preoperative refractive error was +1.43 +/- 0.97 diopters (D) (range 0 to +3.63 D) at the spectacle plane and +1.46 +/- 1.01 D (range 0 to +3.79 D) at the corneal plane. The mean postoperative refractive error was -0.44 +/- 1.07 D (range -2.24 to +2.18 D) at the spectacle plane and -0.44 +/- 1.08 D (range -2.18 to +2.23 D) at the corneal plane. After surgery, corneal powers measured by manual keratometry were significantly smaller than those measured by topography (P<.001) and refractive error changes were significantly smaller than keratometric changes (P<.001). CONCLUSIONS: After LTK, corneal power measured by manual keratometry was smaller than that measured by corneal topography and changes in corneal power measured by conventional keratometric instruments were greater than changes in refractive error. This difference should be considered in calculating IOL power in post-LTK eyes to prevent undesirable hyperopia after cataract surgery.

Adult↗

Revisions to tolerances in cylinder axis and in progressive addition lens power in ANSI Z80.1-2005.

BACKGROUND: ANSI Z80.1 (American National Standards Institute) is a voluntary standard that provides tolerance guidelines for ophthalmic lens parameters. The recently approved ANSI Z80.1-2005 changes tolerances for cylinder axis for all ophthalmic lenses and for distance power for progressive addition lenses (PALs). METHODS: The ANSI Z80.1 committee analyzed the amount of unwanted residual cylinder created by rotating a cylinder axis away from its desired orientation for a range of cylinder powers. The limits of axis orientation error that keep the residual unwanted cylinder error within the tolerances for cylinder power were determined. For PALs, a tolerance for distance power error was sought that considers the currently followed standards for front surface power error and the tooling steps used for the rear surface. RESULTS: Tolerances for cylinder axis error were changed to +/-14 degrees for 0.25 diopter (D) cylinders and to +/-7 degrees for 0.50 D cylinders. Tolerance for error in back vertex power of PALs was changed to +/-0.16 D for both sphere and cylinder. CONCLUSION: Tolerances for cylinder axis for low cylinders have been made in ANSI Z80.1-2005 to be consistent with tolerances in cylinder power. Changes in tolerance for power errors in PALs have been made to recognize fabrication challenges.

Equipment Design↗

Effect of high-powered LED polymerization on the shear bond strength of a light-polymerized resin luting agent to ceramic and dentin.

STATEMENT OF PROBLEM: A newly introduced high-powered light-emitting diode (LED) light-polymerization unit with various polymerization modes is purported to polymerize dental resins more quickly than standard units. However, there is insufficient information about the effects of this type of light source and its polymerization modes on resin luting agents (RLAs). PURPOSE: This in vitro study evaluated the effects of different modes of a high-powered LED polymerization unit on the shear bond strength of a light-polymerized RLA to ceramic and dentin. MATERIAL AND METHODS: Sixty ceramic cylinders (3 x 3 mm) were fabricated from a heat-pressed ceramic (IPS Empress 2). Specimen surfaces were abraded using 600-grit silicon carbide paper and airborne-particle abraded with 50-mum desiccant alumina particles, cleaned ultrasonically, etched using hydrofluoric acid, and treated with a silane coupling agent (Ceramic primer). Sixty noncarious, freshly extracted, permanent human molar teeth were embedded in autopolymerizing acrylic resin, and their dentin surfaces were wet-ground using a grinding and polishing machine fitted with 180-grit abrasive disks. The ground dentin surfaces were then etched with 37% phosphoric acid gel, and an adhesive agent (Single Bond) was applied. Ceramic specimens (n = 15) were bonded to dentin surfaces with a dual-initiated RLA (Rely-X ARC) and individually polymerized by 1 of 4 different modes, as follows: Halogen standard mode (Control) (600 mW/cm2 for 40 seconds); high-powered LED fast mode (1100 mW/cm2 for 10 seconds); high-powered LED pulse mode (1100 mW/cm2 for 10 seconds); and high-powered LED exponential mode (1100 mW/cm2 for 20 seconds). Cemented specimens were subjected to shear loading until fracture using a universal testing machine. A stereomicroscope (x25) was used to identify the mode of fracture. Bond strength (MPa) data were analyzed using 1-way analysis of variance and the Tukey HSD test (alpha = .05). RESULTS: Specimens polymerized using halogen standard mode (23.9 +/- 1.3 MPa) and LED exponential mode (23.0 +/- 1.1 MPa) had significantly higher ( P < .001) mean shear bond strengths compared with both LED fast (15.1 +/- 1.3 MPa) and pulse (14.6 +/- 1.3 MPa) modes. The Tukey HSD tests showed no significant differences in shear bond strength between specimens polymerized using high-powered LED exponential mode and halogen standard mode. Most failures were adhesive failures at the dentin-RLA interface or the RLA-ceramic interface in specimens polymerized using high-powered LED fast or pulse modes. CONCLUSION: Within the limitations of this study, the shear bond strength of an RLA to ceramic and dentin was found to be similar when polymerized using halogen light in standard mode and high-powered LED light in exponential mode, whereas shear bond strength was significantly lower when polymerized using LED in fast or pulse mode.

Analysis of Variance↗

Acoustic power measurement of high intensity focused ultrasound in medicine based on radiation force.

How to measure the acoustic power of HIFU is one of the most important tasks in its medical application. In the paper a whole series of formula for calculating the radiation force related to the acoustic power radiated by a single element focusing transducer and by the focusing transducer array were given. Various system of radiation force balance (RFB) to measure the acoustic power of HIFU in medicine were designed and applied in China. In high power experiments, the dependence of radiation force acting the absorbing target on the target position at the beam axis of focusing transducer was fined. There is a peak value of "radiation force" acting the absorbing target in the focal region when the acoustic power through the focal plane exceeds some threshold. In order to avoid this big measurement error caused by the 'peak effect' in focal region, the distance between the absorbing target of RFB and the focusing transducer or transducer array was defined to be equal to or less than 0.7 times of the focal length in the National Standard of China for the measurements of acoustic power and field characteristics of HIFU. More than six different therapeutic equipments of HIFU have been examined by RFB for measuring the acoustic power since 1998. These results show that RFB with the absorbing target is valid in the acoustic power range up to 500W with good linearity for the drive voltage squared of focusing transducer or array. The uncertainty of measurement is within +/-15%.

Acoustics↗

A simple method for measurement of maximal downstroke power on friction-loaded cycle ergometer.

The aim of this study was to propose and validate a post-hoc correction method to obtain maximal power values taking into account inertia of the flywheel during sprints on friction-loaded cycle ergometers. This correction method was obtained from a basic postulate of linear deceleration-time evolution during the initial phase (until maximal power) of a sprint and included simple parameters as flywheel inertia, maximal velocity, time to reach maximal velocity and friction force. The validity of this model was tested by comparing measured and calculated maximal power values for 19 sprint bouts performed by five subjects against 0.6-1 N kg(-1) friction loads. Non-significant differences between measured and calculated maximal power (1151+/-169 vs. 1148+/-170 W) and a mean error index of 1.31+/-1.20% (ranging from 0.09% to 4.20%) showed the validity of this method. Furthermore, the differences between measured maximal power and power neglecting inertia (20.4+/-7.6%, ranging from 9.5% to 33.2%) emphasized the usefulness of power correcting in studies about anaerobic power which do not include inertia, and also the interest of this simple post-hoc method.

Adult↗

Power-law modeling based on least-squares criteria: consequences for system analysis and simulation.

The power-law formalism was initially derived as a Taylor series approximation in logarithmic space for kinetic rate-laws. The resulting models, either as generalized mass action (GMA) or as S-systems models, allow to characterize the target system and to simulate its dynamical behavior in response to external perturbations and parameter changes. This approach has been succesfully used as a modeling tool in many applications from cell metabolism to population dynamics. Without leaving the general formalism, we recently proposed to derive the power-law representation in an alternative way that uses least-squares (LS) minimization instead of the traditional derivation based on Taylor series [B. Hernández-Bermejo, V. Fairén, A. Sorribas, Math. Biosci. 161 (1999) 83-94]. It was shown that the resulting LS power-law mimics the target rate-law in a wider range of concentration values than the classical power-law, and that the prediction of the steady-state using the LS power-law is closer to the actual steady-state of the target system. However, many implications of this alternative approach remained to be established. We explore some of them in the present work. Firstly, we extend the definition of the LS power-law within a given operating interval in such a way that no preferred operating point is selected. Besides providing an alternative to the classical Taylor power-law, that can be considered a particular case when the operating interval is reduced to a single point, the LS power-law so defined is consistent with the results that can be obtained by fitting experimental data points. Secondly, we show that the LS approach leads to a system description, either as an S-system or a GMA model, in which the systemic properties (such as the steady-state prediction or the log-gains) appear averaged over the corresponding interval when compared with the properties that can be computed from Taylor-derived models in different operating points within the considered operating range. Finally, we also show that the LS description leads to a global, accurate description of the system when it is submitted to external forcing.

Biometry↗