PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Refuse Disposal”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34Linked to original sources

Residual activity of Tc-generators.

Owing to contamination by long-lived radio-isotopes, the residual activity of an old 99Mo-99mTc generator may be large enough to prevent its disposal. The long-lived impurities of one generator were determined by energy spectrum and half-life measurements. In this generator 46Sc, 51Cr, 60 Co, 92mNb, 95Nb and 124Sb nuclides were found. Only the half-life of 60Co exceeds 3 months, thus a moderately long storage of the generator reduces the activity, and its disposal is then safe.

Radioactive Waste↗

A model for optimal operation of land-treatment sites for oily wastes.

Land treatment as a disposal technology has been extensively used for the disposal of oily wastes. Effective management of land treatment sites require optimal operation of the system in order to achieve the fastest and most complete degradation of petroleum hydrocarbons without contamination of the environment. This paper describes a model that can be used for optimising the operation of land treatment sites for oily wastes. The model is composed of system simulator and optimisation submodels. Conceptually, the system simulation submodel is composed of a waste mixing zone, lower treatment zone and aquifer modules. The system simulation model allows for periodic waste applications and determines the spatial and temporal variation of the state variables such as phase summed (total) and aqueous phase contaminant concentrations and water content in the system. The optimisation submodel coupled with the system simulator determines the optimal values of system control variables, such as waste loading rate, infiltration rate, water content, frequency of waste application and the dimensions of the land treatment site. Optimisation of these system control variables is accomplished by maximising the hydrocarbon mass removal from the waste mixing zone under the constraint of satisfying a prespecified water quality criteria in the aquifer. Selected model applications are presented to demonstrate the applicability and utility of the model. Such model applications include determination of the optimal operating conditions for the land treatment of oily wastes under various different site and soil environmental conditions and practical waste disposal scenarios.

Environmental Pollution↗

A study of combustibility of wastes of two hospitals for determining disposal by incineration.

Determination of quantity, quality and characteristics of the wastes of two hospitals located in the same sector of a class B city was undertaken to review the present dumping method of disposal. On an average 1,424.71 and 224.6 kgs. of five types of wastes as per the moisture content were found daily for seven days in these two hospitals of 1000 general beds, and 600 long stay beds for chest tuberculosis and other Cardiothoracic diseases respectively. The wastes of first hospital had higher combustibility due to its sprawling nature and activities for general patients than that of the second multistoreyed hospital treating special cases. A combustibility analysis of hospital wastes would help to decide whether to adopt incineration for disposal.

Hospitals↗

Interim status standards for owners and operators of hazardous waste treatment, storage, and disposal facilities--Environmental Protection Agency. Interim final rule and interim final amendments to rules and request for comments.

The Environmental Protection Agency [EPA] has issued standards applicable to owners and operators of hazardous waste management facilities as required by the Resource Conservation and Recovery Act [RCRA]. One of these standards bans the disposal of most containerized liquid hazardous waste in landfills, effective November 19, 1981. As a result of reconsideration of this restriction, EPA is today promulgating an interim final rule to allow the disposal of small containers of liquid and solid hazardous waste in landfills provided that the wastes are placed in overpacked drums [lab packs] in the manner specified in today's rule. The purpose of today's rule is to provide an environmental sound disposal option for generators of small containers of hazardous wastes, such as laboratories.

Hospitals↗

Consolidated permit regulations and hazardous waste management system: Environmental Protection Agency. Notice of issuance of regulation interpretation memorandum.

The Environmental Protection Agency (EPA) is issuing today a Regulation Interpretation Memorandum (RIM) which provides official interpretation of the issue of whether a generator who accumulates hazardous waste pursuant to 40 CFR 262.34, may qualify for interim status after November 19, 1980. This issue arose when the requirements for submitting a Part A permit application (one of the prerequisites to qualifying for interim status) were amended on November 19, 1980. The provisions interpreted today are part of the Consolidated Permit Regulations promulgated under Subtitle C of the Solid Waste Disposal Act, as amended by the Resource Conservation and Recovery Act, as amended (RCRA).

Refuse Disposal↗

Disposable products in the hospital waste stream.

Use of disposable products in hospitals continues to increase despite limited landfill space and dwindling natural resources. We analyzed the use and disposal patterns of disposable hospital products to identify means of reducing noninfectious, nonhazardous hospital waste. In a 385-bed private teaching hospital, the 20 disposable products of which the greatest amounts (by weight) were purchased, were identified, and total hospital waste was tabulated. Samples of trash from three areas were sorted and weighed, and potential waste reductions from recycling and substituting reusable items were calculated. Business paper, trash liners, diapers, custom surgical packs, paper gowns, plastic suction bottles, and egg-crate pads were among the 20 top items and were analyzed individually. Data from sorted trash documented potential waste reductions through recycling and substitution of 78, 41, and 18 tonnes per year (1 tonne = 1,000 kg = 1.1 tons) from administration, the operating room, and adult wards, respectively (total hospital waste was 939 tonnes per year). We offer specific measures to substantially reduce nonhazardous hospital waste through substitution, minimization, and recycling of select disposable products.

Hospitals, Teaching↗

Medical waste disposal: to burn or to landfill?

Conflicting regulations and varying definitions with regard to medical wastes and their disposal have long been a source of confusion for health care institutions attempting to resolve this problem. Presented for the interest of other concerned agencies are guidelines recently drafted by the task force on medical waste disposal of the Maryland Department of Health and Mental Hygiene for the handling and disposal of medical wastes.

Facility Regulation and Control↗