PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Solid Phase Microextraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34Linked to original sources

Fully automated in-tube solid-phase microextraction for liquid samples coupled to gas chromatography.

An online device is described in which analytes are extracted from a liquid sample by means of in-tube solid-phase microextraction (in-tube SPME), pulse released by rapid heating, and transferred to a gas chromatograph in a fully automated way. Switching of the sample and gas flows as well as the heating of the extraction tube and the valves is controlled by a remote computer system. Results obtained for river water and for aqueous standard solutions of phenanthrene are presented and are compared to the performance of standard SPME.

Journal Article↗

Concentration and fate of persistent organochlorine pesticides in estuarine sediments using headspace solid-phase microextraction.

The concentration and fate of persistent organochlorine pesticides (OCPs) in estuarine surface sediments in Erh-jen and Lan-yang rivers, Taiwan were investigated using headspace solid-phase microextraction (HSSPME) method to evaluate the possible pollution potential and guideline for OCP concentrations in Taiwan. The HSSPME method exhibits a good analytical performance with low detection limits for OCP determination in sediment. In addition, results obtained using the developed HSSPME method were in good agreement with those obtained using Soxhlet extraction in a certified sample. The developed analytical method was further applied to the determination of concentrations of OCP residues in surface sediments from the estuaries of the selected rivers in Taiwan. A total of 20 surface sediments from each river was collected from 10 sampling stations. The total OCP concentrations in sediments from Erh-jen River ranged from 0.17 to 5.04 ng/g-dw with the mean values of 0.25-1.24 ng/g-dw for HCHs, 0.10-0.89 ng/g-dw for cyclodienes and 0.16-0.64 ng/g-dw for DDTs. The concentrations of OCPs in sediments from Lan-yang River were in the range 0.37-0.9 ng/g-dw with an average of lower than 0.5 ng/g-dw. HCHs and DDTs were abundant in the estuarine sediments from the selected rivers. Results obtained in this study show that the origin of OCPs in the surface sediments from Erh-jen River is a combination of erosion of the weathered soils and long-range atmospheric transport, while the OCP concentrations found in Lan-yang River could be regarded as the background levels of OCPs in Taiwan.

Environmental Monitoring↗

New approach of solid-phase microextraction improving the extraction yield of butyl and phenyltin compounds by combining the effects of pressure and type of agitation.

A new methodology for the simultaneous and fast solid-phase microextraction (SPME) of butyl- and phenyltin compounds, as ethylated derivates, is proposed in this paper. The effects of pressure and type of agitation during headspace SPME sampling are evaluated and discussed on the basis of thermodynamic considerations. Quantitative structure-activity relationships were used to estimate analytes partition coefficients allowing to explain the different behaviours experimentally observed. SPME sampling conditions including mechanical stirring and reduced pressure result in simultaneous higher efficiency (detection limits especially lowered for phenyltins up to a eight-fold reduction) and shorter sampling time (two-fold reduction).

Atmospheric Pressure↗

Quantitative determination of wine highly volatile sulfur compounds by using automated headspace solid-phase microextraction and gas chromatography-pulsed flame photometric detection. Critical study and optimization of a new procedure.

The quantitative determination of wine volatile sulfur compounds by automated headspace solid-phase microextraction (HS-SPME) with a carboxen-polydimethylsiloxane (CAR-PDMS) fiber and subsequent gas chromatography-pulsed flame photometric detection (GC-PFPD) has been evaluated. The direct extraction of the sulfur compounds in 5 ml of wine has been found to suffer from matrix effects and short linear ranges, problems which could not be solved by the use of different internal standards or by multiple headspace SPME. These problems were attributed to saturation of the fiber and to competitive effects between analytes, internal standards and other wine volatiles. Another problem was the oxidation of analytes during the procedure. The reduction in sample volume by a factor 50 (0.1 ml diluted with water or brine) brought about a reduction in the amount of sulfur compounds taken in the fiber by a factor just 3.3. Consequently, a new procedure has been proposed. In a sealed vial containing 4.9 ml of saturated NaCl brine, the air is thoroughly displaced with nitrogen, and the wine (0.1 ml) and the internal standards (0.02 ml) are further introduced with a syringe through the vial septum. This sample is extracted at 35 degrees C for 20 min. This procedure makes a satisfactory determination possible of hydrogen sulfide, methanethiol, ethanethiol, dimethyl sulfide, diethyl sulfide and dimethyl disulfide. The linear dynamic ranges cover the normal ranges of occurrence of these analytes in wine with typical r2 between 0.9823 and 0.9980. Reproducibility in real samples ranges from 10 to 20% and repeatability is better than 10% in most cases. The method accuracy is satisfactory, with errors below 20% for hydrogen sulfide and mostly below 10% for the other compounds. The proposed method has been applied to the analysis of 34 Spanish wines.

Automation↗

Determination of fungicides in natural waters using solid-phase microextraction and gas chromatography coupled with electron-capture and mass spectrometric detection.

This study develops a method for the analysis of seven fungicides in environmental waters, using solid-phase microextraction (SPME). The analyzed compounds--dicloran, chlorothalonil, vinclozolin, dichlofluanid, captan, folpet and captafol--belong to different classes of chemical compound (chloroanilines, sulphamides, phthalimides and oxazolidines) and are used mainly in agriculture and as antifouling paints. Their determination was carried out by gas chromatography with electron-capture and mass spectrometric detection. To perform SPME, four types of fibre have been assayed and compared: polyacrylate (85 microm), polydimethylsiloxane (100 and 30 microm), carbowax-divinylbenzene (CW-DVB 65 microm) and polydimethylsiloxane-divinylbenzene (65 microm). The main parameters affecting the SPME process such as pH, salt additives, methanol content, memory effect, stirring rate and adsorption-time profile were studied. The method was developed using spiked natural waters such as ground water, sea water, river water and lake water in a concentration range of 0.1-10 microg/l. Limits of detection of studied compounds were determined in the range of 1-60 ng/l, by using electron-capture and mass spectrometric detectors. The recoveries of all fungicides were in relatively high levels (70.0-124.4%) and the average R2 values of the calibration curves were above 0.990 for all the analytes. The SPME conditions were finally optimized in order to obtain the maximum sensitivity. The potential of the proposed method was realized by applying it to the trace-level screening determination of fungicides and antifouling compounds in sea water samples originating from various Greek marinas.

Calibration↗

Two-fibre solid-phase microextraction combined with gas chromatography-mass spectrometry for the analysis of volatile aroma compounds in cooked pork.

The volatile aroma compounds in cooked pork were examined using solid-phase microextraction (SPME). Two SPME fibres coated with different stationary phases were used simultaneously to collect aroma compounds from the headspace above the pork. One fibre was coated with 75 microm. Carboxen-polydimethylsiloxane and the other was coated with 50/30 microm divinylbenzene-Carboxen on polydimethylsiloxane. After extraction, the two fibres were desorbed in the injection port of a gas chromatograph sequentially, so that the aroma compounds from both of the fibres could be analysed in one gas chromatogram. This procedure resulted in a chromatogram containing a more complete aroma profile for cooked pork than the chromatograms from either of the fibres on their own. Thirty-six compounds were identified in cooked pork for the first

Animals↗

Solid-phase microextraction of polychlorinated biphenyls.

The extraction and analysis of 21 polychlorinated biphenyls (PCBs) ranging from di- to decachlorobiphenyls in ocean, wetland and leachate water samples were achieved using solid-phase microextraction (SPME) with a 100-micron poly(di-methylsiloxane) (PDMS) fiber and gas chromatography-electron-capture detection (GC-ECD). Severe carryover between samples (e.g., 20%) occurs on both stir bars and the SPME fibers demonstrating that it is important to use a new stir bar for each sample, as well as to perform SPME-GC blanks between samples to avoid quantitative errors. The equilibrium partitioning coefficients of individual PCB congeners between PDMS and water were found to be surprisingly different compared to their octanol-water partitioning coefficient (Kow), demonstrating that Kow cannot be used to estimate the partitioning behavior of PCBs in the SPME process. Using a 15-min SPME extraction, SPME analysis with GC-ECD was linear (r2 > or = 0.97) from approximately 5 pg/ml to the solubility limit of each congener. Concentrations in water samples obtained by 15-min SPME extractions compared favorably with those obtained by toluene extractions, demonstrating that SPME combined with GC is a useful technique for the rapid determination of PCBs in water samples.

Absorption↗

Determination of geosmin and 2-methylisoborneol in water using solid-phase microextraction and gas chromatography-chemical ionisation/electron impact ionisation-ion-trap mass spectrometry.

A method for the determination of geosmin and 2-methylisoborneol (MIB) in water by solid-phase microextraction (SPME) is presented. Various SPME fibre chemistries have been compared for their efficiency in extracting MIB from water. Extraction conditions including the extraction time and temperature have been optimised. A 30 ml water sample is extracted for 20 min at 60 degrees C using a divinylbenzene fibre, and the extract analysed by gas chromatography with ion-trap mass spectrometry detection. d5-Geosmin and d3-MIB are added as internal standards to compensate for any variability in the SPME process which is not carried out to equilibrium. Chemical ionisation, using acetonitrile as the reagent gas, was found to give superior sensitivity to electron impact ionisation (EI) for the detection of MIB. EI was used as the ionisation mode for detection of geosmin. The method shows good linearity over the concentration range 5-40 ng l-1 and gives detection limits of 1 ng l-1 for both geosmin and MIB. Recovery (93-110%) and precision (3-12%) over this concentration range, for both raw and treated drinking waters, are comparable to currently employed methods such as closed-loop stripping analysis (CLSA). The method offers the advantage of being simple to use, with much shorter analysis times in comparison to CLSA.

Camphanes↗

Simple analysis of tetracyclic antidepressants in blood using headspace-solid-phase microextraction and GC-MS.

A simple and sensitive method for analysis of three tetracyclic antidepressants, maprotiline, mianserin, and setiptiline, in human whole blood was developed using headspace-solid-phase microextraction (SPME) and gas chromatography-mass spectrometry (GC-MS). A vial containing a blood sample, sodium hydroxide, and imipramine as an internal standard was heated at 120 degrees C. The extraction fiber of the SPME was exposed for 45 min in the headspace of the vial. The compounds absorbed on the fiber were desorbed by exposing the fiber in the injection port of a GC-MS. The calibration curves, using an internal standard method, demonstrated good linearity throughout the concentration range from 0.005 to 5.0 microg/g for mianserin and setiptiline and from 0.025 to 25 microg/g for maprotiline. No interferences were found, and the time for analysis was 60 min for one sample. In addition, this proposed method was applied to a medicolegal case in which the cause of death was suspected to be acute setiptiline poisoning. Setiptiline was detected in the left and right heart blood samples of the victim at concentrations of 1.77 and 0.78 microg/g, respectively.

Antidepressive Agents↗

Determination of volatile compounds in Magnolia bark by microwave-assisted extraction coupled to headspace solid-phase microextraction and gas chromatography-mass spectrometry.

A method is described for the determination of volatile compounds in Magnolia bark using microwave-assisted extraction coupled to headspace solid-phase microextraction (MAE-HS-SPME), followed by gas chromatography with mass spectrometry (GC-MS). Parameters affecting the extraction efficiency, such as sampling time and temperature, microwave irradiation power and desorption time, were investigated to achieve the optimal conditions. The result obtained was compared with that of steam distillation; only small differences existed between these two methods. Therefore, the proposed method seems to be a feasible and relatively simple, fast and solvent-free procedure for identification of essential oils in Magnolia bark.

Journal Article↗

Analysis of alpha, beta, gamma-hexachlorocyclohexanes in water by novel activated carbon fiber-solid phase microextraction coupled with gas chromatography-mass spectrometry.

A fast and simple method for determination of alpha, beta, gamma-hexachlorocyclohexanes (HCHs) in water using activated carbon fiber-solid phase microextraction(ACF-SPME) were studied. Results showed the performance of adsorption and desorption of three HCHs on ACF were excellent. A wide linear range from 10 to 100 microg/L and detection limits of the ng/L level were obtained using ACF-SPME with GC-MS in selected ion monitoring(SIM) acquisition mode. The proposed method was also successfully applied for determination of three HCHs in tap water. Compared to commercial fibers, ACF showed some advantages such as better resistance to solvents, higher thermal stability, longer lifetime and lower cost. The data demonstrated that GC-MS with ACF-SPME is well suitable for the analysis of HCHs in water.

Chemistry Techniques, Analytical↗

Application of headspace solid-phase microextraction (HS-SPME) and comprehensive two-dimensional gas chromatography (GC x GC) for the chemical profiling of volatile oils in complex herbal mixtures.

The coupling of headspace solid-phase microextraction (HS-SPME) with comprehensive two-dimensional gas chromatography (GC x GC) was shown to be a powerful technique for the rapid sampling and analysis of volatile oils in complex herbal materials. When compared to one-dimensional (1-D) GC, the improved analytical capabilities of GC x GC in terms of increased detection sensitivity and separation power were demonstrated by using HS-SPME/GC x GC for the chemical profiling (fingerprinting) of essential/volatile oils contained in herbal materials of increasing analytical complexity. More than 20 marker compounds belonging to Panax quinquefolius (American ginseng) can be observed within the 2-D contour plots of ginseng itself, a mixture of ginseng and another important herb (P. quinquefolius/Radix angelicae sinensis), as well as a mixture of ginseng and three other herbs (P. quinquefolius /R. angelicae sinensis/R. astragali/R. rehmanniae preparata). Such analytical capabilities should be important towards the authentication and quality control of herbal products, which are receiving increasing attention as alternative medicines worldwide. In particular, the presence of Panax in the herb formulation could be readily identified through its specific peak pattern in the 2-D GC x GC plot.

Chromatography, Gas↗

Investigation by solid-phase microextraction and gas chromatography/mass spectrometry of trail pheromones in ants.

The Dufour's gland content of workers of two ant species of the genus Messor has been analyzed by solid-phase microextraction and gas chromatography with mass spectrometry (GC/MS). The structures of the compounds in the pheromonal mixtures have been determined. In both cases only one intact gland, inserted in a properly dimensioned capillary vial, is sufficient to produce a clean and fully interpretable GC/MS profile. It is worth noting that, for the first time in Messor ants, farnesol has been detected as a minor component of glandular secretion in Messor capitatus.

Animals↗

Use of solid-phase microextraction for the detection of acetic acid by ion-trap gas chromatography-mass spectrometry and application to indoor levels in museums.

A simple and efficient method using solid-phase microextraction (SPME) and gas chromatography-ion trap mass spectrometry (GC-ITMS) was developed for the analysis of acetic acid in air. The choice of the SPME fibre revealed to be critical as well as the sampling and desorption time. A dilution vessel was used for calibration. The precision of the method was found to be 4.7% relative standard deviation (RSD) and the detection limit 5.7 microg m(-3). The SPME-GC-MS technique was applied to the analysis of acetic acid in museum atmospheres.

Acetic Acid↗

Determination of dichloromethane, trichloroethylene and perchloroethylene in urine samples by headspace solid phase microextraction gas chromatography-mass spectrometry.

A method for the determination of volatile chlorinated hydrocarbons, namely dichloromethane (DCM), trichloroethylene (TCE), and perchloroethylene (PCE), in urine samples was developed using headspace solid phase microextraction (HS-SPME) gas chromatography-mass spectrometry (GC-MS). HS-SPME was performed using a 75 microm Carboxen-polydimethylsiloxane fiber. Factors, which affect the HS-SPME process, such as adsorption and desorption times, stirring, salting-out effect, and temperature of sampling have been evaluated and optimized. The highest extraction efficiency was obtained when sampling was performed at room temperature (22 degrees C), from samples saturated with salt and under agitation. Linearity of the HS-SPME-GC-MS method was established over four orders of magnitude and the limit of detection was 0.005 microg/l for all the compounds. Precision, calculated as %R.S.D. at three different concentration levels, was within 1-8% for all intra- and inter-day determinations. The method was applied to the quantitative determination of TCE and PCE in human urine samples from exposed (TCE, n=5; median, 9.32 microg/l and PCE, n=39; median, 0.58 microg/l) and non-exposed individuals (n=120; median concentrations, 0.64, 0.22 and 0.11 microg/l for DCM, TCE and PCE, respectively. In addition, two cases of acute accidental exposure to DCM are reported, and the elimination kinetics in blood and urine was followed up. The calculated half-lives of urinary and blood DCM were, respectively, 7.5 and 8.1 h for one subject and 3.8 and 4.3 h for the other.

Adult↗

Determination of daidzein and genistein in soybean foods by automated on-line in-tube solid-phase microextraction coupled to high-performance liquid chromatography.

An automated on-line method for the determination of the isoflavones, daidzein and genistein, was developed using in-tube solid-phase microextraction coupled to high-performance liquid chromatography (in-tube SPME-HPLC). In-tube SPME is a new extraction technique for organic compounds in aqueous samples, in which analytes are extracted from the sample directly into an open tubular capillary by repeated draw/eject cycles of sample solution. Daidzein, genistein and their glucosides tested in this study were clearly separated within 8 min by HPLC using an XDB-C8 column with diode array detection. In order to optimize the extraction of these compounds, several in-tube SPME parameters were examined. The glucosides daidzin and genistin were analyzed as aglycones after hydrolysis because the glucosides were not concentrated by in-tube SPME. The optimum extraction conditions for daidzein and genistein were obtained with 20 draw/eject cycles of 40 microl of sample using a Supel-Q porous layer open tubular capillary column. The extracted compounds were easily desorbed from the capillary by mobile phase flow, and carryover was not observed. Using the in-tube SPME-HPLC method, the calibration curves of these compounds were linear in the range 5-200 ng/ml, with a correlation coefficient above 0.9999 (n = 18), and the detection limits (S/N = 3) were 0.4-0.5 ng/ml. This method was successfully applied to the analysis of soybean foods without interference peaks. The recoveries of aglycones and glucosides spiked into food samples were above 97%.

Automation↗

Determination of methadone and its metabolites EDDP and EMDP in human hair by headspace solid-phase microextraction and gas chromatography-mass spectrometry.

A simple method for analysis of methadone and its two main metabolites EDDP and EMDP in hair was developed using automatic headspace solid-phase microextraction (HS-SPME) at a multipurpose sampler and gas chromatography-mass spectrometry with electron impact ionization and selected ion monitoring (GC-MS-SIM). The washed hair pieces were digested in the closed headspace vial in 1 ml 1 M NaOH containing 0.5 g NaCl and each 10 ng of the internal standards D9-methadone and D3-EDDP at 110 degrees C for 20 min. Then the HS-SPME was performed with a 65 microm polydimethylsiloxan/ divinylbenzene fiber at the same temperature in the same vial for another 20 min followed by the desorption in the GC injection port. The calibration curves were linear between 0.1 and 3 ng/mg (methadone and EMDP) and 10 ng/mg (EDDP) respectively, at higher concentrations a negative deviation from linearity was found. The detection limits were 0.03 ng/mg (methadone) and 0.05 ng/mg (EDDP and EMDP), and the reproducibility was 9.2% for methadone and 11.2% for EDDP (n= 12). The method was applied to hair samples of 26 drug fatalities. 19 cases were positive with 0.36-11.8 ng/mg methadone and 0.19 -10.8 ng/mg EDDP. EMDP was found only in two cases with 0.18 and 0.84 ng/mg. The methadone concentration range was in agreement with previous data, but the EDDP/methadone concentration ratios (0.19-0.67) were definitely higher than those determined by other methods.

Adsorption↗

Simple analysis of local anaesthetics in human blood using headspace solid-phase microextraction and gas chromatography-mass spectrometry-electron impact ionization selected ion monitoring.

A simple method for analysis of five local anaesthetics in blood was developed using headspace solid-phase microextraction (HS-SPME) and gas chromatography-mass spectrometry-electron impact ionization selected ion monitoring (GC-MS-EI-SIM). Deuterated lidocaine (d10-lidocaine) was synthesized and used as a desirable internal standard (I.S.). A vial containing a blood sample, 5 M sodium hydroxide and d10-lidocaine (I.S.) was heated at 120 degrees C. The extraction fiber of the SPME system was exposed for 45 min in the headspace of the vial. The compounds adsorbed on the fiber were desorbed by exposing the fiber in the injection port of a GC-MS system. The calibration curves showed linearity in the range of 0.1-20 microg/g for lidocaine and mepivacaine, 0.5-20 microg/g for bupivacaine and 1-20 microg/g for prilocaine in blood. No interfering substances were found, and the time for analysis was 65 min for one sample. In addition, this proposed method was applied to a medico-legal case where the cause of death was suspected to be acute local anaesthetics poisoning. Mepivacaine was detected in the left and right heart blood samples of the victim at concentrations of 18.6 and 15.8 microg/g, respectively.

Anesthetics, Local↗