PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Speech Reception Threshold Test”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34Linked to original sources

Binaural masking level difference for speech signals in noise.

This study investigates the binaural masking level difference in both detection and recognition of speech embedded in noise when the signal is phase-shifted 180 degrees between the left and the right ear. Swedish spondaic words masked by noise werc presented binaurally to 10 normally hearing subjects. The results are presented in terms of speech detection threshold, speech recognition threshold, a psychometric function of speech recognition versus signal-to-noise ratio, and speech intelligibility as a function of binaural intelligibility level difference. Both speech detection threshold and speech intelligibility improved when the speech signal was phase-shifted 180 degrees. The binaural intelligibility level difference ranged from 5.7 to 7.7 dB.

Adolescent↗

Preservation of hearing in patients undergoing microsurgery for vestibular schwannoma: degree of meatal filling.

OBJECT: Preservation of hearing has become a standard goal in selected patients undergoing surgery for a vestibular schwannoma (VS). This study was aimed at analyzing the role played by filling of the internal auditory canal (IAC) as well as those played by preoperative hearing quality, and tumor size in the postoperative preservation of serviceable hearing (SH). METHODS: Three hundred eighty-six patients with VS were treated. Hearing preservation was attempted in 128 cases (33.2%) by using intraoperative monitoring and following a retrosigmoid approach. The maximal extrameatal size of the tumor, its extension within the IAC, and pre- and postoperative hearing quality, according to the Gardner-Robertson classification, were evaluated. Preservation of SH was achieved in 24.2% of the 128 patients. With respect to tumor size, SH was preserved in 39% of 77 patients harboring a tumor 15 mm wide or smaller and in 2% of 51 patients with lesions 16 mm wide or larger (p < 0.001). With regard to filling of the IAC, among 63 patients harboring a tumor 15 mm or smaller, in whom magnetic resonance images were available, SH was preserved in 52.8% of 36 patients with partial filling and in 25.9% of 27 patients with complete filling (p = 0.032). Concerning preoperative hearing quality, in the patients with tumors 15 mm or smaller, SH was preserved in 46.5% of 43 patients with Gardner-Robertson Class I hearing and 29.4% of 34 patients with Class II hearing (p = 0.126). Both tumor size and the extent of IAC filling proved statistically significant in a multivariable analysis (p < 0.001 and p = 0.026, respectively). CONCLUSIONS: Incomplete filling of the IAC and a tumor size of 15 mm or smaller are independent favorable factors in SH preservation. Excellent preoperative hearing appears to have a positive impact but does not have statistical significance. Intraoperative monitoring is useful in guiding the dissection; however, the surgeon's knowledge of topographical landmarks and meticulous surgical technique remain the essential factors of success.

Adult↗

Minimal spectral contrast of formant peaks for vowel recognition as a function of spectral slope.

In four experiments we investigated whether listeners can locate the formants of vowels not only from peaks, but also from spectral "shoulders"--features that give rise to zero crossings in the third, but not the first, differential of the excitation pattern--as hypothesized by Assmann and Summerfield (1989). Stimuli were steady-state approximations to the vowels [a, i, e, u, o] created by summing the first 45 harmonics of a fundamental of 100 Hz. Thirty-nine harmonics had equal amplitudes; the other 6 formed three pairs that were raised in level to define three "formants." An adaptive psychophysical procedure determined the minimal difference in level between the 6 harmonics and the remaining 39 at which the vowels were identifiably different from one another. These thresholds were measured through simulated communication channels, giving overall slopes of the excitation patterns of the five vowels that ranged from -1 dB/erb to + 2 dB/erb. Excitation patterns of the threshold stimuli were computed, and the locations of formants were estimated from zero crossings in the first and third differentials. With the more steeply sloping communication channels, some formants of some vowels were represented as shoulders rather than peaks, confirming the predictions of Assmann and Summerfield's models. We discuss the limitations of the excitation pattern model and the related issue of whether the location of formants can be computed from spectral shoulders in auditory analysis.

Adult↗

Simulated conductive hearing loss in children.

Otitis media with effusion (OME) often results in hearing loss for children with the condition. In order to provide appropriate and effective audiologic management, it is important to understand the impact of OME on speech recognition ability when hearing loss is present. This study examined the speech recognition abilities of normal-hearing six- and seven-year-old children (n = 12) and adults (n = 12) using monosyllabic words and nonsense syllables presented at two levels of simulated conductive hearing loss characteristic of OME. Average speech recognition scores decreased as the degree of simulated conductive hearing loss increased. Both age groups scored significantly poorer for nonsense syllables than for monosyllabic words. In general, the children performed more poorly than the adults with the exception of the easiest listening condition for word stimuli. Furthermore, children appeared less able than adults to use their knowledge of familiar words to improve performance. These findings suggest that rehabilitative strategies may best be focused on combining familiarization techniques and amplification options.

Adult↗

Sound quality measures for speech in noise through a commercial hearing aid implementing digital noise reduction.

This brief report discusses the affect of digital noise reduction (DNR) processing on aided speech recognition and sound quality measures in 14 adults fitted with a commercial hearing aid. Measures of speech recognition and sound quality were obtained in two different speech-in-noise conditions (71 dBA speech, +6 dB SNR and 75 dBA speech, +1 dB SNR). The results revealed that the presence or absence of DNR processing did not impact speech recognition in noise (either positively or negatively). Paired comparisons of sound quality for the same speech in noise signals, however, revealed a strong preference for DNR processing. These data suggest that at least one implementation of DNR processing is capable of providing improved sound quality, for speech in noise, in the absence of improved speech recognition.

Adult↗

The effect of intensity on pitch in electric hearing and its relationship to the speech perception performance of cochlear implantees.

This study investigated the effect of intensity on pitch in electric hearing and its relationship to the speech perception ability of cochlear implantees. Subjects were 13 adult users of the Nucleus 22 cochlear implant system, using either the Spectra22 or ESPrit22 speech processor and the SPEAK speech processing strategy. A multidimensional scaling technique was employed. Speech perception was measured using sentences and vowels. All measurements were performed in a soundfield condition, and subjects wore their own speech processors with their normally used settings. Results showed a significant correlation between the degree of deviation of the subjects' stimulus spaces from the "ideal" space and subjects' performance with the sentences, but not with the vowels. A significant correlation was found between subjects' response variability in performing the multidimensional scaling task and their speech perception measures, suggesting that spectral smearing or underlying cognitive abilities might affect implantees' speech perception performance.

Acoustic Stimulation↗

Word recognition of digit triplets and monosyllabic words in multitalker babble by listeners with sensorineural hearing loss.

In an initial experiment (Wilson and Weakley, 2004), word recognition was assessed with six digit triplets presented at 14 signal-to-babble ratios (S/B) in 2 dB steps. An abbreviated version of the protocol was developed for clinic use involving three digit triplets at 7 S/Bs in 4 dB steps. The purpose of this experiment was to examine the relationship between the two digit protocols with comparisons made with other variables including age, pure-tone thresholds, subjective measures of understanding speech in quiet and in noise, and word recognition of monosyllabic words in quiet and in babble. Ninety-six listeners with sensorineural hearing loss participated. For equivalent performance, the short version of the digit triplets required (1) a 2.6 dB more favorable S/B than the long version and (2) a 15.1 dB less favorable S/B than the words. Age, hearing loss, and subjective evaluation of the ability to understand speech in quiet and in noise were not related to performance on digits or words in multitalker babble.

Acoustic Stimulation↗

Effect of type of noise and loudspeaker array on the performance of omnidirectional and directional microphones.

Differences in performance between omnidirectional and directional microphones were evaluated between two loudspeaker conditions (single loudspeaker at 180 degrees; diffuse using eight loudspeakers set 45 degrees apart) and two types of noise (steady-state HINT noise; R-Space restaurant noise). Twenty-five participants were fit bilaterally with Phonak Perseo hearing aids using the manufacturer's recommended procedure. After wearing the hearing aids for one week, the parameters were fine-tuned based on subjective comments. Four weeks later, differences in performance between omnidirectional and directional microphones were assessed using HINT sentences presented at 0 degrees with the two types of background noise held constant at 65 dBA and under the two loudspeaker conditions. Results revealed significant differences in Reception Thresholds for Sentences (RTS in dB) where directional performance was significantly better than omnidirectional. Performance in the 180 degrees condition was significantly better than the diffuse condition, and performance was significantly better using the HINT noise in comparison to the R-Space restaurant noise. In addition, results revealed that within each loudspeaker array, performance was significantly better for the directional microphone. Looking across loudspeaker arrays, however, significant differences were not present in omnidirectional performance, but directional performance was significantly better in the 180 degrees condition when compared to the diffuse condition. These findings are discussed in terms of results reported in the past and counseling patients on the potential advantages of directional microphones as the listening situation and type of noise changes.

Aged↗

Case report and discussion of hearing preservation after translabyrinthine excision of small acoustic tumors.

OBJECTIVE: Since 1991, three separate reports have shown how hearing may be salvaged after translabyrinthine excision of small acoustic tumors. The authors submit yet another report of a complete translabyrinthine excision of a 1.4-cm intracanalicular acoustic tumor with modest hearing preservation. An attempt is made to retrace the steps of the operation and recognize and discuss what particular events may have safeguarded the viability of the cochlea. With the availability of cochlear implantation, there should be added incentive to preserve the cochlear neurones if hair cells cannot be saved. STUDY DESIGN: The study design was a retrospective case review. SETTING: The study was conducted at a primary care hospital. INTERVENTION: Therapeutic and rehabilitative measures were performed. MAIN OUTCOME MEASURES: Hearing preservation was measured. CASE REPORT: A 55-year-old woman presented with a left-sided hearing loss and a 1.4-cm left acoustic tumor completely filling the internal auditory canal (speech reception threshold [SRT] 30 dB, discrimination [Pb] 28%). A successful translabyrinthine excision of the tumor was performed in November 1995. A 1-year postoperative audiogram showed a mixed hearing loss in the left ear with SRT 85 dB and Pb 0%. Average pure-tone threshold for 500 Hz, 1 kHz, and 3 kHz was 50 dB and aided SRT 40 dB with Pb 64%. Postoperative magnetic resonance imaging confirmed complete excision of the tumor. CONCLUSION: An exceptional case of hearing preservation after translabyrinthine excision of a small acoustic tumor illustrates how it may be possible to preserve cochlear hair cells and neurones simultaneously in certain selected cases. A review of the surgical events shows the value of sealing the cochlear duct with bone wax, selectively removing the vestibular nerves with the tumor by sharp dissection, and safeguarding the meatal segment of the anterior inferior cerebellar artery by a limited dural incision.

Cranial Nerve Neoplasms↗

Intralabyrinthine schwannomas.

OBJECTIVE: To describe characteristic features of intralabyrinthine schwannomas (ISs) that may be used to distinguish them from other otologic disorders with similar symptoms so that appropriate evaluation and management can be instituted. STUDY DESIGN: This study was a retrospective case review. SETTING: This study was conducted at a university-affiliated urban tertiary care medical center and a university medical center in the same city. PATIENTS: Seven patients with ISs were included in this study. INTERVENTIONS: Tumor removal versus observation and monitoring with periodic magnetic resonance imaging (MRI) scans was investigated. MAIN OUTCOME MEASURES: Hearing, vertigo, and tumor growth were measured. RESULTS: Four of seven patients with ISs underwent surgical excision with no evidence of tumor recurrence. The remaining three patients are being followed-up with repeat MRI that has demonstrated minimal or no tumor growth. CONCLUSIONS: ISs can be detected in early stages if MRI is performed in patients with unilateral sensorineural hearing loss without vertiginous symptoms typical of Meniere's disease. Although complete surgical excision can be achieved readily with labyrinthectomy, observation and monitoring with rep--MRI is an option for some patients.

Adult↗

Speech recognition with in-the-ear and behind-the-ear dual-microphone hearing instruments.

The primary purpose of this study was to compare the overall listening benefit in diffuse noise provided by dual-microphone technology in an in-the-ear (ITE) hearing instrument to that provided by dual-microphone technology in a behind-the-ear (BTE) hearing instrument. Further, the study was designed to determine whether the use of the dual-microphone + the manufacturer's party response algorithm in the ITE and BTE hearing instruments provided listening benefit in diffuse noise over their respective omnidirectional microphone modes. Twenty-four adults with mild to moderately severe sensorineural hearing loss were evaluated while wearing binaural BTE and ITE hearing instruments. The results indicated that the dual-microphone + party response mode did provide significant benefit in diffuse noise for both the ITE (3.27 dB signal-to-noise ratio [SNR] improvement) and BTE (5.77 dB SNR improvement) hearing instruments relative to their respective conventional omnidirectional microphones. No significant difference in performance was found between the ITE and BTE hearing instruments when each device was in the dual-microphone + party response mode. It is concluded that the use of dual-microphone technology in both ITE and BTE hearing instruments can improve speech recognition in diffuse noise.

Adult↗

Preference for the closed technique in the management of cholesteatoma of the middle ear in children: a retrospective study of 215 consecutive patients treated over 10 years.

OBJECTIVES: To evaluate clinical data, extensions, residual and recurrent lesion rates, and functional results in cases of cholesteatoma in pediatric patients. DESIGN: A retrospective study at a single tertiary care center over a decade. PATIENTS: In 199 children (mean age 9.6 years), 215 cholesteatomas were treated surgically, and the children were followed up for an average of 70 months (range 25-118 months). INTERVENTIONS: Therapeutic and rehabilitative surgical procedures were done, using either a closed technique (CT) or an open technique: tympanoplasty in open technique (TOT), radical mastoidectomy (RM), or Rambo's technique) MAIN OUTCOME MEASURES: Surgical findings, residual and recurrent lesions rate, and hearing assessment. RESULTS: The first surgical procedure was CT in 88% of cases, TOT in 10%, RM and Rambo's technique in 1%. Two operations were done in 61.8% of children; 21% had three operations and 4.5% had four. Residual lesions were observed in 21.5% of all children, 32.8% in those undergoing a planned second look. Recurrence rate was 9.8%. Surprisingly, residual and recurrent lesion rates were higher after TOT (23.8% and 19%) than after CT (20.5%, 8.9%), but TOT-treated children had much more extensive lesions. A speech reception threshold (SRT) <30 dB hearing loss (HL) was achieved in 63.7% of patients, and normal hearing was obtained in 12.1%; SRT was significantly better after CT (mean 26.7 dB) than after TOT (mean 37.4 dB), after type II (mean 27 dB) than after type III (35 dB). A high-frequency pure-tone hearing loss >10 dB was uncommon (7.6%). CONCLUSION: These results support the continued use of CT in most cases of cholesteatoma in children in developed countries.

Adolescent↗

Speech recognition ability in noise and its relationship to perceived hearing aid benefit.

Hearing-impaired listeners with similar hearing losses may differ widely in their ability to understand speech in noise. Such individual susceptibility to noise may explain why patients obtain varying degrees of benefit from hearing aids. The chief purpose of this study was to determine if adaptive measures of unaided speech recognition in noise were related to hearing aid benefit. Additionally, the relationship between perceived hearing handicap and benefit from amplification was explored. Before being fit with hearing aids, 47 new hearing aid users completed a self-assessment measure of hearing handicap Then, unaided speech recognition ability was measured in quiet and in noise. Three months later, subjects completed a hearing aid benefit questionnaire. A weak relationship was observed between perceived hearing handicap and hearing aid benefit. There were no significant relationships between speech-in-noise measures and hearing aid benefit, suggesting that speech recognition ability in noise is not a major determinant of the benefit derived from amplification.

Adult↗

Audiometric evaluation of bilaterally fitted bone-anchored hearing aids.

Bilateral fittings of bone-anchored hearing aids (BAHA) were evaluated in 25 patients with at least 3 months experience with using two BAHAs. For all patients, air conduction hearing aids were contraindicated due to either recurrent otorrhoea or otitis externa (19 cases) or to congenital aural atresia (six cases). Candidacy for bilateral fitting was primarily based on symmetry of bone conduction thresholds. For all patients, measurements comprised sound localisation, speech recognition in quiet and in noise. In addition, in a subgroup of nine patients, release from masking for pure-tone stimuli in noise with interaural phase differences (binaural masking level difference. BMLD) was measured. The percentage of correct localisation judgments with 500-Hz and 2-kHz noise bursts increased significantly (p<0.01) from 22.2 per cent and 24.3 per cent for unilateral fittings to 41.8 per cent and 45.3 per cent for bilateral fittings, respectively. With unilateral fittings sound localisation judgments appeared to be strongly biased to the ipsilateral BAHA side. whereas with bilateral fittings, judgments were far more symmetrical. The speech reception threshold for sentences in quiet was significantly (p<0.01) better for the bilateral fittings compared to the unilateral fittings: 37.5 dBA versus 41.7 dBA. Speech recognition in noise was measured with the speech signal presented in front of the listener and a 65-dBA masking noise at either +90 degrees or -90 degrees azimuth. For noise presented at the ipsilateral side of the first fitted BAHA, the signal-to-noise ratio was significantly reduced (p<0.01) from -0.7 dB for the unilateral fitting to -4.0 dB for the bilateral fitting. The speech reception threshold in noise was not significantly different (p>0.05) for unilateral and bilateral fittings when the noise was presented at the contralateral side of the first fitted BAHA. The results for the six patients with congenital atresia are comparable with those for the other patients. So, directional hearing and speech recognition in noise improve significantly with a second BAHA. The BMLD measurements showed a significant (p<0.01) release from masking of 6.1, 6.0 and 6.6 dB for 125-Hz, 250-Hz and 500-Hz stimuli, respectively. The BMLD effect of 4.1 dB at 1,000 Hz was not significant at the 5 per cent level. The positive results with the bilateral fittings in quiet can be ascribed to increased stimulus levels due to diotic summation of signals from either side. The results for localisation, speech recognition in noise and BMLD measurements indicate that bilaterally fitted BAHAs do indeed (to some extent) result in binaural hearing.

Adolescent↗

Inner ear damage in children due to noise exposure from toy cap pistols and firecrackers: a retrospective review of 53 cases.

This retrospective study presents the findings of inner ear damage documented in 53 children exposed to impulsive sound emitted by toy weapons and firecrackers. There were 49 boys and four girls aged between four and fourteen years. Thirty-nine children were affected unilaterally while fourteen had bilateral hearing loss (total of 67 ears). Most of the hearing loss (>70%) was sensorineural high frequency hearing loss, while only nine out of the 67 injured ears had sensorineural mid frequency hearing loss. Seven children sustained a traumatic ear drum perforation. Dizziness or tinnitus was reported by twenty children, with pathological ENG findings in four of them. This paper re-emphasizes the possibility of inner ear damage in children from exposure to noisy toys.

Adolescent↗

[Therapeutic trial with corticosteroid for auditory neuropathy].

OBJECTIVE: To explore the feasibility of corticosteroid for the treatment of auditory neuropathy. METHODS: Six patients with auditory neuropathy, diagnosed in the first affiliated hospital of Nanjing medical university between July 1998 and December 2001, were treated with corticosteroid therapy for one month (30-40 mg of prednisone daily for the first fifteen days, and 20 mg daily for following fifteen days). Prednisone was tapered gradually if a positive response to therapy was obtained. Hearing improvement was defined as 15 dB or more threshold drops in at least two of the standard audiometric frequencies in the same ear during the trial period. RESULTS: After one month's steroid treatment, significant hearing improvement was evident in two patients with raised speech discrimination scores from 48% to 95% and from 72% to 100%, respectively. In these two cases, prednisone was used continually up to 14 and 16 weeks, respectively, and the patients still had excellent pure tone hearing abilities and speech discriminations during follow-up of three years and four months, respectively. In other four patients, positive response for corticosteroid was not found within the period of one-month trail. CONCLUSION: Immunological damages of hearing system might play part role in the pathophysiological mechanisms of auditory neuropathy, and corticosteroids are potentially useful drugs for these cases.

Adolescent↗

Use of the event-related P300 potential in cochlear implant subjects for the study of strategy-dependent speech processing.

The present overview is a compilation of the results of several event-related potential (ERP) studies on auditory cortical processing, performed in the Evoked Potential Laboratory of the University Medical Centre of Nijmegen. To study speech perception performance in cochlear implant (CI) subjects, ERPs were obtained from subjects with poor and moderate performance. The present report describes the relationships between speech-coding strategies, the presentation of speech by the CI processor, the P300 potential as a measure of speech discrimination, time effects in the long term and speech recognition in relation to ERPs.

Brain Stem↗