PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Ti implants”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34Linked to original sources

Development of fatigue lifetime predictive test methods for hip implants: part I. Test methodology.

The fatigue failure of hip joint prostheses will be expected to assume more importance in second generation implants aimed at younger, more active patients. Furthermore, new designs and material combinations including coatings (e.g. hydroxyapatite) may introduce fatigue problems that as yet have not been considered. The current research makes an initial attempt to develop accelerated fatigue testing procedures to enhance the methodology of hip implant lifetime prediction. Tests conducted on a 'model' four point bendbar testpiece (mill-annealed Ti-6A1-4V) highlighted that the accelerated test must be conducted in a physiological solution such as Ringer's at 37 degrees C. The introduction of superimposed block overloads (50 cycles) to signify stair ascent/descent or fast walking and single overloads to signify sit/stand movements or stumbling were found to reduce fatigue life by > 50%. The findings of this fatigue study were combined with biomechanics studies to construct a variable amplitude 'in-service' load spectrum for testing hip implants. Using ambulatory trial data, a simple load sequence was designed containing 4 single (sit/stand movements) and 3 block (stair ascent/descent) overloads that repeated ten times gave one days activity; single overloads repeated every 110 base cycles (normal walking) and block overloads 80, 110 (morning/evening) and 250 (daytime) base cycles.

Alloys↗

Increased osteoblast adhesion on nanograined hydroxyapatite and tricalcium phosphate containing calcium titanate.

Depending on the coating method utilized and subsequent heat treatments (such as through the use of plasma-spray deposition), inter-diffusion of atomic species across titanium (Ti) and hydroxyapatite (HA) coatings may result. These events may lead to structural and compositional changes that consequently cause unanticipated HA phase transformations which may clearly influence the performance of an orthopedic implant. Thus, the objective of the present in vitro study was to compare the cytocompatibility properties of chemistries that may form at the Ti:HA interface, specifically HA, tricalcium phosphate (TCP), HA doped with Ti, and those containing calcium titanate (CaTiO(3)). In doing so, results of this study showed that osteoblast (bone-forming cells) adhesion increased with greater CaTiO(3) substitutions in either HA or TCP. Specifically, osteoblast adhesion on HA and TCP composites with CaTiO(3) was almost 4.5 times higher than that over pure HA. Material characterization studies revealed that enhanced osteoblast adhesion on these compacts may be due to increasing shrinkage in the unit lattice parameters and decreasing grain size. Although all CaTiO(3) composites exhibited excellent osteoblast adhesion results, Ca(9)HPO(4)(PO(4))(5)OH phase transformation into TCP/CaTiO(3) increased osteoblast adhesion the most; because of these reasons, these materials should be further studied for orthopedic applications.

Bone Substitutes↗

Effect of surface treatment on unalloyed titanium implants: spectroscopic analyses.

Surgical implant finishing and sterilization procedures were investigated to determine surface characteristics of unalloyed titanium (Ti). All specimens initially were cleaned with phosphoric acid and divided into five groups for comparisons of different surface treatments (C = cleaned as above, no further treatment; CP = C and passivated in nitric acid; CPS = CP and dry-heat sterilized; CPSS = CPS and resterilized; CS = C and dry-heat sterilized). Auger (AES), X-ray photoelectron (XPS), and Raman spectroscopic methods were used to examine surface compositions. The surface oxides formed by all treatments primarily were TiO2, with some Ti2O3 and possibly TiO. Significant concentrations of carbonaceous substances also were observed. The cleaning procedure alone resulted in residual phosphorus, primarily as phosphate groups along with some hydrogen phosphates. A higher percentage of physisorbed water appeared to be associated with the phosphorus. Passivation (with HNO3) alone removed phosphorus from the surface; specimens sterilized without prior passivation showed the thickest oxide and phosphorus profiles, suggesting that passivation alters the oxide characteristics either directly by altering the oxide structure or indirectly by removing moieties that alter the oxide. Raman spectroscopy showed no crystalline order in the oxide. Carbon, oxygen, phosphorus, and nitrogen presence were found to correlate with previously determined surface energy.

Electron Probe Microanalysis↗

Corrosion and wear-corrosion behavior of NiTi modified by plasma source ion implantation.

The understanding of corrosion behavior in NiTi is critical for the devices using this shape-memory alloy. In order to improve the surface properties of NiTi such as corrosion resistance, plasma source ion implantation (PSII) technique was employed with oxygen as incident ions at three levels of implantation dose (5x10(16), 1x10(17) and 3x10(17) ions/cm(-2)). Pitting corrosion and wear-corrosion behavior of control and PSII-modified Ti-50.7at% Ni alloy were evaluated by cyclic potentiodynamic polarization and wear-corrosion measurements. Surface characterization was used to interpret the different corrosion behavior observed between control and oxygen-implanted samples. Results showed that corrosion behavior was influenced by both heat treatment and surface modification. The best pitting corrosion resistance was observed for samples with Af=21 degrees C modified by oxygen implantation at a dose of 1x10(17) ions/cm(-2). Better wear-corrosion resistance was observed for oxygen-implanted samples.

Biocompatible Materials↗

Biomechanical and histological analysis of an HA coated, arc deposited CPTi canine hip prosthesis.

The interfacial shear strength and bone tissue response was investigated for an arc deposited (AD) commercially pure titanium implant surface, with (AD/HA) and without (AD) plasma-sprayed hydroxyapatite (HA) coating. Ten purpose bred coonhounds received bilateral femoral stem implantation (AD and AD/HA) in the proximal femurs (hemiarthroplasty). The femoral prosthesis consisted of a modular CoCr alloy head, modular Ti-6Al-4V neck, and a 10-mm diameter cylindrical Ti-6Al-4V femoral stem. The AD surface had 30-35% greater surface roughness than the AD/HA surface. The HA coating had a purity greater than 90% and a crystallinity greater than 65%. After 6, 12, and 24 weeks, the implants were retrieved and analyzed with mechanical testing, qualitative and quantitative histology, and electron microscopy. The AD/HA implants had equivalent interfacial shear strengths to the AD implants at all time periods. The AD/HA implants had significantly greater linear bone contact than the AD implants. The 6-week implants had significantly thicker cortical bone than the 12- and 24-week implants. The HA coating was very stable in vivo, evidenced by no thickness reduction at any time period. Qualitatively, the AD/HA implants primarily had bone contacting the implant surface with little fibrous tissue present, and the AD implants had bone and fibrous tissue contacting the implant surface. The electron microscopy analysis showed that the mechanically tested implants exhibited a mixed failure mode at the bone, HA coating, and titanium interfaces.

Animals↗

Is galvanic corrosion between titanium alloy and stainless steel spinal implants a clinical concern?

BACKGROUND CONTEXT: Surgeons are hesitant to mix components made of differing metal classes for fear of galvanic corrosion complications. However, in vitro studies have failed to show a significant potential for galvanic corrosion between titanium and stainless steel, the two primary metallic alloys used for spinal implants. Galvanic corrosion resulting from metal mixing has not been described in the literature for spinal implant systems. PURPOSE: To determine whether galvanic potential significantly affects in vitro corrosion of titanium and stainless steel spinal implant components during cyclical compression bending. STUDY DESIGN/SETTING: Bilateral spinal implant constructs consisting of pedicle screws, slotted connectors, 6.35-mm diameter rods and a transverse rod connector assembled in polyethylene test blocks were tested in vitro. Two constructs had stainless steel rods with mixed stainless steel (SS-SS) and titanium (SS-Ti) components, and two constructs had titanium rods with mixed stainless steel (Ti-SS) and titanium (Ti-Ti) components. METHODS: Each construct was immersed in phosphate-buffered saline (pH 7.4) at 37 C and tested in cyclic compression bending using a sinusoidal load-controlling function with a peak load of 300 N and a frequency of 5 Hz until a level of 5 million cycles was reached. The samples were then removed and analyzed visually for evidence of corrosion. In addition, scanning electron microscopy (SEM) and energy dispersive spectrometry (EDS) were used to evaluate the extent of corrosion at the interconnections. RESULTS: None of the constructs failed during testing. Gross observation of the implant components after disassembly revealed that no corrosion had occurred on the surface of the implants that had not been in contact with another component. The Ti-Ti interfaces showed some minor signs of corrosion only detectable using SEM and EDS. The greatest amount of corrosion occurred at the SS-SS interfaces and was qualitatively less at the SS-Ti and Ti-SS interfaces. CONCLUSIONS: The results from this study indicate that when loaded dynamically in saline, stainless steel implant components have a greater susceptibility to corrosion than titanium. Furthermore, the galvanic potential between the dissimilar metals does not cause a discernible effect on the corrosion of either. Although the mixture of titanium alloy with stainless steel is not advocated, the results of this study suggest that galvanic corrosion is less pronounced in SS-Ti mixed interfaces than in all stainless steel constructs.

Alloys↗

[SIMS (secondary ion mass spectroscopy) and XPS (x-ray photoelectron spectroscopy) study of titanium implant surfaces coated with anodic titanium-oxide layer].

The demands that must be satisfied by titanium implants applied in medical practice include chemical and physical durability. An anodic oxide protective layer formed on the surface of titanium implants serves for the better attainment of this aim. The composition of the passivizing layer and the changes in its thickness and binding state can be studied by method of material science, e.g. by secondary ion mass spectroscopy (SIMS) and X-ray photoelectron spectroscopy (XPS). In this way a possibility arises for the material technological classification of the Ti-TiO2 layer structure and for the observation of the physical and chemical reactions that occur between the implants and the tissues in the organism. The present XPS examinations revealed that the binding state of the titanium forming the surface of the plates involve neither significant quantities of titanium oxide nor impurities. In the SIMS investigation the thickness of the titanium oxide layer was found to be 120-150 nm. Determination of the thickness of the surface, the binding state of the titanium and the exact proportions of the impurities and additives furnishes a possibility for a subsequent comparison with the surface structure of plates removed from the organism. It is important for the assessment of the practical value of the protective layer.

Dental Implants↗

Rat bone marrow cell response to titanium and titanium alloy with different surface roughness.

In general, cell response is affected by both chemical composition and surface roughness of implant materials. The aim of this study was to evaluate the effect of titanium (Ti) chemical composition and surface roughness on the response of rat bone marrow cells, examining cell attachment, cell proliferation, total protein content, alkaline phosphatase (ALP) activity, and bone-like nodule formation. Cells were cultured on both commercially pure titanium (cpTi) and titanium-6-aluminum-4-vanadium alloy (Ti-A) discs with four different average roughnesses (Ra). For attachment evaluation, cells were cultured for 2 h. After 14 days, cell proliferation, total protein content, and ALP activity were evaluated. Bone-like nodule formation was evaluated after 21 days. Data were compared by anova and Duncan's multiple range test when appropriate. Cell attachment and total protein content were affected by neither Ti chemical composition (P = 0.201, and P = 0.639, respectively) or surface roughness (P = 0.972, and P = 0.660, respectively). Proliferation, ALP activity, and bone-like nodule formation were affected only by Ti chemical composition (P = 0.0001, P = 0.064, and P = 0.0001, respectively). These results suggest that cpTi would optimize osteoblastic differentiation by rat bone marrow cells, including reduced cell proliferation, and increased ALP activity and bone-like nodule formation, while surface roughness, within the Ra parameters used, would not affect significantly the rat bone marrow cell response.

Alkaline Phosphatase↗

[Good results with a cemented titanium stem after 7-9 years].

AIM: Because of partially ver y controversial results in cemented hip stem replacements made of titanium alloy we investigated in our own patients the mid-term survival of the "Euroform"-stem. This stem is anatomically designed for cemented fixation, made of Ti (6)Al (4)V. METHOD: Within a period between 1990 and 2000 we implanted 2,141 Euroform-prostheses. The course of 103 patients which were operated between April 1990 and April 1992 was followed up. 9 patients died in the meantime and 8 could not be reached. Of the remaining 86 patients we could examine 73 patients with 79 prostheses (87 %). Investiagtion included a questionnaire and clinical and radiological examination to create the Harris-hip-score. The follow-up was 7-9 years, with an average of 94 months. RESULT: Of those 79 prostheses, revision surgery was performed for septic loosening in three cases and for aseptic loosening in two cases. Radiologically one stem was found to be loosen. This means that for aseptic loosening we had a revision rate for aseptical femoral loosening of 2.5 % after 94 months with a mean Harris-hip-score of 84 points. Good or excellent results were found in 82 %, fair results in 9 % and poor results in 9 %. CONCLUSION: The "Euroform" prosthesis is a cemented titanium alloy stem that has in contrary to some other published studies good mid- to long-term results.

Adult↗

Samarium-145: a new brachytherapy source.

A new radiation source has been produced for brachytherapy, with radiation energies slightly above those of 125I, and a T1/2 of 340 d. This source, 145Sm, is produced by neutron irradiation of 144Sm (96.5% enriched). Decay is by electron capture with 140 K x-rays per 100 disintegrations in the energy region between 38-45 keV, plus 13 gamma-rays at 61 keV. These sources are encapsulated in Ti tubes, approximately 0.8 mm X 4.5 mm, and have been developed for temporary implantation in brain and ocular tumours. The 38-61 keV photons should make such sources easy to shield, while providing a dose distribution from source arrays somewhat more homogeneous than that from 125I. In addition, the 340 d half life of 145Sm permits its use for times significantly longer than that of 60 d 125I. While the 145Sm sources have been designed primarily for implantation in a brain tumour, they should be useful for almost any conventional brachytherapy application.

Brachytherapy↗

Nanostructured ceramics for biomedical implants.

Recent progress in the synthesis, characterization, and biological compatibility of nanostructured ceramics for biomedical implants is reviewed. A major goal is to develop ceramic coating technology that can reduce the friction and wear in mating total joint replacement components, thus contributing to their significantly improved function and longer life span. Particular attention is focused on the enhancement of mechanical properties such as hardness, toughness, and friction coefficient and on the bioactivity as they pertain to the nanostructure of the material. The development of three nanostructured implant coatings is discussed: diamond, hydroxyapatite, and functionally graded metalloceramics based on the Cr-Ti-N ternary system. Nanostructured diamond produced by chemical vapor deposition (CVD) techniques and composed of nano-size diamond grains have particular promise because of the combination of ultrahigh hardness, improved toughness over conventional microcrystalline diamond, low friction, and good adhesion to titanium alloys. Nanostructured processing applied to hydroxyapatite coatings is used to achieve the desired mechanical characteristics and enhanced surface reactivity and has been found to increase osteoblast adhesion, proliferation, and mineralization. Finally, nanostructured metalloceramic coatings provide continuous variation from a nanocrystalline metallic bond at the interface to the hard ceramic bond on the surface and have the ability to overcome adhesion problems associated with ceramic hard coatings on metallic substrates.

Animals↗

Fretting corrosion in orthopaedic alloys.

Fretting corrosion, a mechanical-chemical phenomenon, most often occurs at screwhead-plate countersink junctions of internal fixation devices. An apparatus was constructed which would simulate the conditions of fretting corrosion in vivo. Fretting corrosion was studied as a function of the number of cycles and the solution in which the fretting occurred. The solutions studied were 0.9% physiological saline and a saline plus 0.5% albumin solution. The implant materials tested were Co-Cr-Mo alloy, 316L stainless steel, and Ti-6A1-4V alloy. The results demonstrated that weight loss increased with the number of fretting cycles but reached a plateau where further weight loss was negligible. Co-Cr-Mo alloy showed less weight loss than 316L stainless steel at any number of cycles. Weight loss for Ti-6A1-4V alloy was similar to Co-Cr-Mo alloy although marked abrasion was noted. All of the materials showed a marked decrease in weight loss when tested in the saline plus albumin solution as compared to the saline only solution.

Alloys↗

[The HA-Ti system].

Some concepts and techniques are discussed while stressing the collaboration between specialists to design a new type of implant. Important aspects are: a simple implantation procedure, a wide field for indication and non-traumatic surgical placement.

Dental Implantation, Endosseous↗

Wear-resistant, hemocompatible Ti-Nb-Zr and Zr-Nb alloys to improve blood pump design and performance.

Over the past several years, we have developed novel titanium-niobium-zirconium (Ti-Nb-Zr) alloys to address the long-term performance needs of orthopedic implants. The unique properties of these alloys also render them promising candidates for blood pumps. These properties include excellent biocompatibility in combination with high strength and toughness, and low elastic modulus (low stiffness). Additionally, these metal alloys are readily hot or cold worked into complex shapes including wire, foil, tubing and bar. They are readily machined and polished, and they can be surface oxidized to form a hard, wear-resistant, low-friction ceramic surface layer. In this diffusion-hardened condition, oxygen also hardens the underlying metal to optimize the bone between the ceramic oxide surface and the tough metal substrate. Unlike metal surfaces, oxidative wear, which can alter surface energy, friction, and hemocompatibility, does not occur. Consequently, the combined benefits of a stable, wear-resistant, low-friction ceramic surface layer with the toughness, strength, formability, and thermal conductivity of metal may provide improvements in the design and performance of blood pumps and peripheral graft and percutaneous (power) components of the pump.

Alloys↗

Immediate implantation in fresh extraction sockets. A controlled clinical and histological study in man.

BACKGROUND: Early implantation may preserve the alveolar anatomy, and the placement of a fixture in a fresh extraction socket helps to maintain the bony crest. Although a number of clinical studies exist, no histological reports show the outcome of implantation in fresh extraction sockets without the use of membranes in humans compared to implants placed in mature bone. METHODS: Forty-eight healthy patients, receiving at least 4 fixtures in each of 2 symmetrical quadrants, underwent placement of 1 experimental fixture placed in a fresh extraction socket (TI) and 1 contralateral fixture in mature bone (CI). TI were placed after atraumatical tooth extraction, with a surgical site at the apex of the socket and a tight contact between the fixture and the socket's walls, but without the use of filling materials or membranes. The flap was coronally repositioned to obtain primary wound closure. Immediately after surgical intervention, a standardized periapical radiograph was taken. Second-stage surgery was done after 6 months. Six months after the second surgery, a second standardized periapical radiograph was taken and clinical parameters (bleeding and plaque index) recorded. Marginal bone loss (MBL) from the time of implant placement to the time of fixture removal was calculated by comparing periapical radiographs. TI and CI were then removed by a hollow drill to obtain histological specimens. Non-demineralized sections were stained by acid fuchsin and toluidine blue, and by von Kossa to evaluate the degree of bone mineralization. The percentage of direct implant-bone contact (DBC) was calculated by a computerized microscopic digitizer. RESULTS: No significant differences in the clinical and radiographic parameters were observed between the 2 experimental categories. There was no statistically significant difference between TI and CI for DBC either in the maxilla or in the mandible. No connective or fibrous tissues were present around TI or CI. Bone resorption was not present in any of the histological sections. CONCLUSIONS: The present study shows that when a screw-type dental implant is placed without the use of barrier membranes or other regenerative materials into a fresh extraction socket with a bone-to-implant gap of 2 mm or less, the clinical outcome and degree of osteointegration does not differ from implants placed in healed, mature bone.

Adult↗

Marginal zone of the murine spleen in autotransplants: functional and histological observations in the response against a thymus-independent type 2 antigen.

Splenic tissue from mice was autotransplanted; after initial necrosis, a rapid restoration of implants into a structure histologically indistinguishable from splenic tissue was observed. The development of the marginal zone in these autotransplants, as determined with monoclonal antibodies against different splenic cell types and routine histological stains, was compared with the local and systemic response against a thymus-independent (TI) type 2 antigen. Full restoration of time course and peak of anti-trinitrophenyl (TNP) serum titres against TNP-Ficoll was observed at 4 weeks after autotransplantation. Anti-TNP antibody-forming cells were observed in subnormal and normal numbers in 2- and 4-week old autotransplants, respectively. The appearance of normal numbers of antibody-forming cells, and the restoration of antibody titres at week 4 correlated with the return of newly formed B cells in a normal marginal zone. An unexpected observation was that marginal zone macrophages did not return until 10 weeks after transplantation, thereby making the necessity for these cells in the normal TI-2 response unlikely. We conclude that normal anti-TI-2 responses (onset and peak titres) can be restored by autotransplantation of splenic tissue. B cells and marginal zone organization are responsible for this response, for which marginal zone macrophages seem expendable. The partial protection against overwhelming post-splenectomy infections, given by autotransplants, can thus be explained by restorative capabilities of these implants on antigen presentation and antibody formation against TI-2 antigens, and not by an increase (compared with splenectomized individuals) of phagocytosis by marginal zone macrophages.

Animals↗

Reactions in rat gluteal muscle to titanium implants.

A new approach to the analysis of tissue-implant interaction is presented using rat gluteal muscle as implantation site and using monoclonal antibodies to identify and quantify cells around the implant. The method can be used for comparative studies on biocompatibility. In this methodological investigation, pure titanium (Ti) was studied, revealing an initial response of macrophages, followed by the formation of a fibrous membrane, in which, even at 50 and 70 d, la-expressing cells and suppressor T-lymphocytes were present.

Animals↗

Composite hip prosthesis design. II. Simulation.

An investigation was performed to study the mechanical performance of fiber-reinforced composite hip prostheses. In Part I of the study, a three-dimensional finite element code was developed for analyzing a composite hip prosthesis in a femur. The material properties of the composite were treated as anisotropic and inhomogeneous while the properties of the femoral bone were treated as anisotropic and homogeneous. All the materials were assumed to behave linear-elastically. Thermoplastic graphite/PEEK material was selected for the study. No slippage was assumed at the interface between the implant and the surrounding femoral bone. In Part II, numerical simulations were performed using the code to study the performance of a composite prosthesis in the femur. The stress/strain distributions, micromotions, and strain energy density of the surrounding femoral bone were evaluated and found to be related to initial fixation and long-term stability of the prosthesis in the femur. Numerous fiber orientations were studied, and the results of the calculations were compared with those generated from a prosthesis made of cobalt chrome and Ti-6Al-4V titanium alloys. Based on the analysis, it was shown that compared to conventional metallic implants more favorable stresses and deformations could be generated in the femur using composite implants. In addition, by changing fiber orientations according to femoral loads, a composite implant could be designed specifically for the left or the right femur.

Computer Simulation↗