PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “ARTIFICIAL ORGANS”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35Linked to original sources

[The trends of new drug development in the 21st century].

The trends of new drug development in the 21st century were described. First, the history of drug development including that of the drug delivery system (DDS) was shown. Then, the recent drugs and therapeutic technology were discussed in detail. These topics are biomedicine, gene related technology, vaccine, hybrid artificial organ, chemical and phage library, fetal growth hormone, cell therapy, humanized anti-body and Viagra. In addition, some natural products were introduced, emphasizing the relationship between food and human health. Finally, I stated my opinion about the new drug development in the 21st century in Japan.

Biopharmaceutics↗

Applications of polymer nanofibers in biomedicine and biotechnology.

Recent advancements in the electrospinning method enable the production of ultrafine solid and continuous fibers with diameters ranging from a few nanometers to a few hundred nanometers with controlled surface and internal molecular structures. A wide range of biodegradable biopolymers can be electrospun into mats with specific fiber arrangement and structural integrity. Through secondary processing, the nanofiber surface can be functionalized to display specific biochemical characteristics. It is hypothesized that the large surface area of nanofibers with specific surface chemistry facilitates attachment of cells and control of their cellular functions. These features of nanofiber mats are morphologically and chemically similar to the extracellular matrix of natural tissue, which is characterized by a wide range of pore diameter distribution, high porosity, effective mechanical properties, and specific biochemical properties. The current emphasis of research is on exploiting such properties and focusing on determining appropriate conditions for electrospinning various polymers and biopolymers for eventual applications including multifunctional membranes, biomedical structural elements (scaffolds used in tissue engineering, wound dressing, drug delivery, artificial organs, vascular grafts), protective shields in specialty fabrics, and filter media for submicron particles in the separation industry. This has resulted in the recent applications for polymer nanofibers in the field of biomedicine and biotechnology.

Biocompatible Materials↗

Machine learning approaches for phenotype-genotype mapping: predicting heterozygous mutations in the CYP21B gene from steroid profiles.

OBJECTIVE: Non-linear relations between multiple biochemical parameters are the basis for the diagnosis of many diseases. Traditional linear analytical methods are not reliable predictors. Novel nonlinear techniques are increasingly used to improve the diagnostic accuracy of automated data interpretation. This has been exemplified in particular for the classification and diagnostic prediction of cancers based on expression profiling data. Our objective was to predict the genotype from complex biochemical data by comparing the performance of experienced clinicians to traditional linear analysis, and to novel non-linear analytical methods. DESIGN AND METHODS: As a model, we used a well-defined set of interconnected data consisting of unstimulated serum levels of steroid intermediates assessed in 54 subjects heterozygous for a mutation of the 21-hydroxylase gene (CYP21B) and in 43 healthy controls. RESULTS: The genetic alteration was predicted from the pattern of steroid levels with an accuracy of 39% by clinicians and of 64% by linear analysis. In contrast, non-linear analysis, such as self-organizing artificial neural networks, support vector machines, and nearest neighbour classifiers, allowed for higher accuracy up to 83%. CONCLUSIONS: The successful application of these non-linear adaptive methods to capture specific biochemical problems may have generalized implications for biochemical testing in many areas. Nonlinear analytical techniques such as neural networks, support vector machines, and nearest neighbour classifiers may serve as an important adjunct to the decision process of a human investigator not 'trained' in a specific complex clinical or laboratory setting and may aid them to classify the problem more directly.

Adult↗

Influence of electric field on the unsteady dispersion coefficient in couple-stress flow.

The influence of electric field on unsteady convective diffusion in couple stress flow is studied using a time dependent dispersion model. The electric field, arising as a body couple in the governing equations, is shown to increase the axial dispersion coefficient. This is useful in the control of haemolysis caused by artificial organs implanted or extracorporeal. The contribution of pure convection in the dispersion of concentration is singled out and investigated in detail. The results obtained are compared with those in the absence of electric field and some important conclusions are drawn.

Animals↗

Viability evaluation of engineered tissues.

Biohybrid artificial organs encompass all devices capable of substituting for an organ or tissue function and are fabricated from both synthetic materials and living cells. The viability of engineered tissue could be related to the viability of implanted cells. The system of viability assay for mammalian cell culture can be applied to the determination of cell viability for engineered tissue. This review explores various methods of cell viability assay which can be applied to the viability evaluation of engineered tissue. The major criteria employed in viability assays include survival and growth in tissue culture, functional assay, metabolite incorporation, structural altercation, and membrane integrity. Each viability assay method is based on different definitions of cell viability, and has inherent advantages and disadvantages. In order to be able to assess the viability of cells with one assay method, it is desirable to compare the viability measurements from various assays derived from different criteria.

Animals↗

Common ethical issues in regenerative medicine.

One of the common ethical issues in regenerative medicine is progress in 'componentation' (= being treated as parts) of the human body, and the enhancement of the view of such "human body parts." 'Componentation' of the human body represents a preliminary step toward commodification of the human body. The process of commodification of the human body follows the steps of 'materialization' (= being treated as a material object) [first step] -- 'componentation' [second step] -- 'resourcialization' (= being treated as resources) [third step] -- commodification [fourth step]. Transplantation medicine and artificial organ developments have dramatically exposed the potential of organs and tissues as parts, and regenerative medicine has a role in advancing 'componentation' of the human body and further enhancing the view of human body parts. The 'componentation' of the human body, regardless of the degree of regenerative medicine's contribution to it, is considered as a challenge to the traditional view of human bodies and the abstract value of "Human Dignity" in the same way or alongside the 'resourcialization' and commodification. However, in the future, a new perspective of human bodies that means "a perspective whereby human bodies, organs, tissues, and even the bodies themselves are perceived as disposable tools like disposable cameras, syringes, or contact lens" and therefore a new ethical view, suitable for a new reality, may emerge.

Biomedical Research↗

The thrombocyte membrane in circulatory diseases.

There is no certain evidence for the proposition, often put forward, that thrombocytes, or platelets, are involved in atherogenesis. On the other hand, thrombotic deposits in arteries as well as in the blood channels of artificial organs consist at first mainly of platelets. This contribution reviews evidence indicating that the formation of such thrombi depends on alterations in the platelet membrane and that these in turn depend on an agent, apparently ADP, which is released from the erythrocytes.

Adenosine Diphosphate↗

Medical technology assessment: the use of the analytic hierarchy process as a tool for multidisciplinary evaluation of medical devices.

Most types of medical technology assessment are performed only after the technology has been developed. Consequently, they have only minor effects on changes in clinical practice. Our study introduces a new method of constructive medical technology assessment that can change the development and diffusion of a medical device to improve its later clinical effectiveness. The method, based on Saaty's Analytic Hierarchy Process, quantitatively supports discussions between various parties involved in technological development and diffusion. We applied this method in comparing a new blood pump with two competitors based on technical, medical and social requirements. These discussions changed the evaluators' perspectives, reduced diasagreements, and ended in a reliable evaluation of the pump's performance. On the basis of these results, adaptations were derived which improved the design and diffusion of the blood pump. This application shows the adequate potential of our method to steer technological development and diffusion of artificial organs.

Decision Making↗

Platelet function in calves: a study of adhesion, aggregation, release, clotting factor activity and life span.

Normal calf platelets were found to significantly differ human platelets in a number of important respects. The average calf platelet count is more than twice the average human value. Calf platelets demonstrated no adhesion to glass, in a test in which over 50% of human platelets adhered. Responsiveness to several aggregating, agents, including ADP, thrombin and collagen, was markedly diminished in the calf platelet, requiring much higher concentrations of the stimulating agent to produce comparable responses. In addition, calf platelet clot-promoting activity was far less effective than with human platelets following stimulation with Celite or Russell's viper venom, although the total platelet factor 3 content exceeded that found in human paltelets, following complete disruption. In addition, the calf platelet has a significantly shorter life span and higher turnover rate than the human. These species differences in normal platelet function must be considered in evaluating the results of experiments with artificial organs in the calf model.

Animals↗

[First successful clinical application of tissue engineered blood vessel].

With this tissue engineering (TE) technique, the peripheral pulmonary artery was successfully reconstructed, using the patient's own venous cells in a 4-year-old girl, 2 years after Fontan procedure. A 4-year-old girl was given a diagnosis of single right ventricle, double-outlet right ventricle and pulmonary atresia. She underwent left modified Blalock-Taussig shunt at a month old, pulmonary artery angioplasty at a year and 3 months old, and bidirectional cavopulmonary shunt at 2 years and a month old. She underwent again pulmonary artery angioplasty and Fontan operation at 3 years and 3 months. An angiographical examination 7 months after the operation revealed total occlusion of the right intermediate pulmonary artery. TE technique using autologous cells was indicated. The application of this procedure was approved by the ethical committee in Tokyo Women's Medical University. The patient's parents were thoroughly informed and signed a consent form. Approximately 2 cm of the peripheral vein was explanted under sterile conditions. The tissue was minced, placed in tissue culture dishes and cultured at 37 degrees C, 100% humidity and a 5% CO2 atmosphere for almost a month. The number of cells substantially increased to reach 12 millions for almost a month. The culture medium was changed every 3 days. The polymer tube that served as a scaffold for cells was composed of the copolymer of PCL-PLA (50:50) with reinforcement by woven PGA. The polymer conduit, 10 mm in diameter, 20 mm in length and 1 mm in thickness, was designated to biodegradate within 8 weeks. The number of seeded cells was approximately a million/cm2. The graft transplantation was performed 10 days after seeding cells. The occlusive right intermediate pulmonary artery was reconstructed with the TE vessel graft under extracorporeal circulation with a pump-oxygenator. The patient followed a satisfactory postoperative course. The postoperative angiography demonstrated that the graft was not constricted and dilated but that it preserved good patency. Long-term follow-up are necessary. We plan to continue to use the TE technique using autologous cells in the low pressure system like venous or pulmonary circulation. Because our results even in early experimental phase were valuable and promising, we believe that the TE approach may play an important role in the near future as an another alternative, together with transplantation and artificial organ, especially in the field of cardiovascular surgery that mostly needs replants.

Blood Vessel Prosthesis Implantation↗

[Applications of porous polymeric materials and its biocompatibility].

With the barrier materials, guided tissue regeneration materials and hybrid artificial organs as the representafive materials, the applications of polymer skeletal materials in biomedical fields are introduced in this paper. Based on the results of the induced carcinoma, collagenous encapsulation and chronic inflammation around implanted polymers, the effects of polymers topography on biocompatibility are discussed, and the importance of topographical compatibility of materials is emphasized.

Biocompatible Materials↗

Sewer sediment transport studies using an environmentally controlled annular flume.

This paper provides an overview and some preliminary results of a collaborative project recently completed at WL Delft Hydraulics. It describes tests in an annular flume, in which sediment deposits were formed under carefully controlled and monitored environmental conditions. The deposits were then subjected to a series of time steps in which the rotational speed of the flume's top and bottom plates was increased, progressively increasing the bed shear stress. The sediment deposits were formed using three different types of sediment. An artificial organic sediment, together with a uniformly sized sand were selected as surrogate sewer sediments. The deposits in the remaining experiments were real in-sewer sediments, from catchments in the UK (Dundee) and The Netherlands (Loenen). During the erosion test, total and volatile suspended solids concentration, particle size distribution of the eroded sediment, and COD and DO levels were recorded. The bed surface topography was also measured so that the influence of the deposit formation condition on bedforms could also be examined. Where bed consolidation times were least 24 hours a biologically active surficial layer was observed to develop at the sediment/water interface. The initial deposit conditions (temperature and deposit duration) were both found to have a significant impact on the subsequent erosion of the deposit.

Environmental Monitoring↗

[Intelligent materials in regenerative medicine and the use].

Intelligent material is one of the most important concepts in the area of material technology. Intelligent materials have functions including those of sensors, processors and actuators. In short, intelligent materials have the potential to respond to changes in the surrounding environment. For example, the material can change its conformation and/or release various factors as its environment changes. Intelligent material is well known as a material for use in drug delivery systems(DDS). A material that releases insulin in well controlled amounts has been used in the treatment of diabetes. There is also a great need for new materials that function as the scaffold of bio-artificial organs. In addition, the technology of intelligent materials will play an important role in the area of tissue engineering and regenerative medicine.

Biocompatible Materials↗

Influence of aspirin and carbacyclin on bovine platelet function.

Cows, calves, and sheep are the animals of choice for in vivo studies on total artificial hearts. In this study, the response of human and bovine platelets to agonists and antagonists was followed. Epinephrine and arachidonate failed to cause aggregation of bovine platelets. Exposure of bovine platelets to prostaglandin E1 (PGE1) resulted in inhibition of response to the action of adenosine diphosphate (ADP). Although epinephrine restored the response of PGE1 treated human platelets, it failed to restore the sensitivity of bovine platelets to the action of ADP. Exposure of bovine platelets to aspirin (100.0 mumol/L) or administration to calves intravenously (10.0 mg/kg) inhibited platelet cyclo-oxygenases. Infusion of carbacyclin (U55185) inhibited the ex vivo platelet response to the action of ADP. Results of this study demonstrate that the response of bovine platelets to agonists such as epinephrine, arachidonate, and the endoperoxide mimetic, U46619, is severely compromised. The authors' observations in this study, as well as earlier findings demonstrating the inability of bovine platelets to fully spread on a surface, suggests that the cow may not be an appropriate "model" for evaluating thrombogenicity caused by artificial organs and implants.

Adenosine Diphosphate↗

Bioreactors for tissue engineering--a new role for perfusionists?

Tissue engineering is an exciting new area of medicine with rapid growth and expansion over the last decade. It has the potential to have a profound impact on the practice of medicine and influence the economic development in the industry of biotechnology. In almost every specialty of medicine, the ability to generate replacement cells and develop tissues will change the focus from artificial organs and transplantation to growing replacement organs from the patient's own stem cells. Once these organs are at a size that requires perfusion to maintain oxygen and nutrient delivery, then automated perfusion systems termed "bioreactors" will be necessary to sustain the organ until harvesting. The design of these "bioreactors" will have a crucial role in the maintenance of cellular function throughout the growth period. The perfusion schemes necessary to determine the optimal conditions have not been well elucidated and will undergo extensive research over the next decade. The key to progress in this endeavor will development of long-term perfusion techniques and identifying the ideal pressures, flow rates, type of flow (pulsatile/nonpulsatile), and perfusate solution. Perfusionists are considered experts in the field of whole body perfusion, and it is possible that they can participate in the development and operation of these "bioreactors." Additional education of perfusionists in the area of tissue engineering is necessary in order for them to become integral parts of this exciting new area of medicine.

Allied Health Personnel↗

Protection of erythrocytes from sub-hemolytic mechanical damage by nitric oxide mediated inhibition of potassium leakage.

The effects of mechanical stress on red blood cell (RBC) deformability were evaluated by subjecting cells to a uniform fluid shear stress of 120 Pa for 15-120 seconds at 37 degrees C. This level of stress induced significant impairment of RBC deformability as assessed by ektacytometry, with the degree of impairment independent of extracellular calcium concentration. Inhibition of RBC nitric oxide (NO) synthesis by a competitive inhibitor of NO synthases (N-omega-nitro-L-arginine methyl ester, L-NAME) had no effect on deformability after exposure to mechanical stress. The NO donor sodium nitroprusside (SNP) prevented the deterioration of RBC deformability in a dose-dependent manner with 10(-4) M being the most effective concentration. A similar protective effect by the non-selective potassium channel blocker, tetraethylammonium chloride (TEA) suggests that the effect of NO might be mediated by the inhibition of potassium leakage from RBC. These results suggest that NO may prevent mechanical deterioration of RBC exposed to high shear stresses. While RBC are not exposed to such high levels of shear stresses for prolonged periods under normal circulatory conditions, comparable levels of mechanical stress can be encountered under certain situations (i.e., artificial organs, extracorporeal circulation) and may result in subhemolytic damage and hemorheological alterations.

Adult↗

Molecular adsorbent recirculating system (MARS).

INTRODUCTION: Molecular adsorbent recirculating system (MARS) for albumin liver dialysis has been used as a bridge to liver transplantation in patients with fulminant hepatic failure (FHF). This review examines the available data on its clinical use, its technical aspects and present gaps in knowledge. METHODS: Peer-reviewed journals and monographs on the subject were covered. RESULTS: FHF is associated with elevation in various substances including bilirubin, ammonia, lactate, free fatty acids and aromatic amino acids. Some of these toxic metabolites, such as ammonia and bilirubin, are believed to be central to the clinical manifestations of hepatic encephalopathy and acute renal failure. MARS ameliorates both biochemical and clinical manifestations of FHF by removing both water-soluble and protein-bound toxins. Among the benefits of MARS is the attenuation of severe cerebral oedema and raised intracranial pressure found in FHF, possibly through reduction in high concentrations of these toxins. Although MARS has been shown to be useful in FHF, its clinical efficacy in subfulminant hepatic failure and less severe forms of acute liver failure (ALF) remains uncertain. The current literature also suggests that it may be beneficial to treat cases of acute-on-chronic liver failure (AoCLF). Deranged systemic chemistries can be similarly ameliorated, but the impact of MARS on the natural history of AoCLF remains uncertain. The difficulty lies in being able to accurately quantify residual liver function and variability in the course of acute intercurrent events. The broader question is whether MARS can favourably change the natural history of ALF and FHF. For this, large multi-centre, randomised controlled trials are needed. Furthermore, it is also uncertain how hepatic excretory-assist devices, such as MARS, compare with bio-artificial liver-assist devices which have both synthetic and excretory hepatic functions in ALF treatment in intensive care unit patients. Nevertheless, MARS has proven to be a valuable homeostatic tool that may be useful in restoring the biochemical and clinical status quo in much the same way that continuous veno-venous haemofiltration and mechanical ventilation provide temporary artificial organ support while these organs are in distress. This is the evolving concept of multi-organ support therapy. Other major unresolved issues with MARS include the timing of initiation of albumin liver dialysis, the clinical and/or biochemical parameters to base this decision on, the intensity of MARS therapy (continuous versus intermittent) and the saturation capacity of the system for different metabolites in intermittent MARS. CONCLUSIONS: MARS is an effective and, thus far, safe homeostatic tool in treating FHF. More studies are needed to delineate its role as a homeostatic tool in less severe forms of ALF, including that which occurs in multi-organ failure and in AoCLF. Other studies need to focus on the optimal timing of initiation of and intensity of MARS albumin liver dialysis. The larger issue is to compare MARS with bio-assist liver devices in treating the whole spectrum of ALF.

Albumins↗

Novel quantitative methods for the determination of biomaterial cytotoxicity.

Two novel methods for the determination of biomaterial cytotoxicity using cell culture are presented. The methods combine a standardized protocol for producing extracts from medical devices with either the established MTT assay or a new fluorimetric assay. The suitability of both methods for evaluating the toxicity of candidate materials was demonstrated by resolution of the differences in the toxic effects of serial dilutions of a PVC extract on BHK21 and HT1080 cells. The tests yield highly reproducible, quantitative results and can be applied to materials in the usual physical forms applicable to artificial organs.

Animals↗