Development of an ion mobility spectrometer for use in an atmospheric pressure ionization ion mobility spectrometer/mass spectrometer instrument for fast screening analysis.

An ion mobility spectrometer that can easily be installed as an intermediate component between a commercial triple-quadrupole mass spectrometer and its original atmospheric pressure ionization (API) sources was developed. The curtain gas from the mass spectrometer is also used as the ion mobility spectrometer drift gas. The design of the ion mobility spectrometer allows reasonably fast installation (about 1 h), and thus the ion mobility spectrometer can be considered as an accessory of the mass spectrometer. The ion mobility spectrometer module can also be used as an independently operated device when equipped with a Faraday cup detector. The drift tube of the ion mobility spectrometer module consists of inlet, desolvation, drift, and extraction regions. The desolvation, drift and extraction regions are separated by ion gates. The inlet region has the shape of a stainless steel cup equipped with a small orifice. Ion mobility spectrometer drift gas is introduced through a curtain gas line from an original flange of the mass spectrometer. After passing through the drift tube, the drift gas serves as a curtain gas for the ion-sampling orifice of the ion mobility spectrometer before entering the ion source. Counterflow of the drift gas improves evaporation of the solvent from the electrosprayed sample. Drift gas is pumped away from the ion source through the original exhaust orifice of the ion source. Initial characterization of the ion mobility spectrometer device includes determination of resolving power values for a selected set of test compounds, separation of a simple mixture, and comparison of the sensitivity of the electrospray ionization ion mobility spectrometry/mass spectrometry (ESI-IMS/MS) mode with that of the ESI-MS mode. A resolving power of 80 was measured for 2,6-di-tert-butylpyridine in a 333 V/cm drift field at room temperature and with a 0.2 ms ion gate opening time. The resolving power was shown to be dependent on drift gas flow rate for all studied ion gate opening times. Resolving power improved as the drift gas flow increased, e.g. at a 0.5 ms gate opening time, a resolving power of 31 was obtained with a 0.65 L/min flow rate and 47 with a 1.3 L/min flow rate for tetrabutylammonium iodide. The measured limits of detection with ESI-MS and with ESI-IMS/MS modes were similar, demonstrating that signal losses in the IMS device are minimal when it is operated in a continuous flow mode. Based on these preliminary results, the IMS/MS instrument is anticipated to have potential for fast screening analysis that can be applied, for example, in environmental and drug analysis.

Journal Article↗

Determination of imidacloprid, metalaxyl, myclobutanil, propham, and thiabendazole in fruits and vegetables by liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry.

Imidacloprid, metalaxyl, myclobutanil, propham, and thiabendazole have been simultaneously determined in strawberries, oranges, potatoes, pears, and melons by matrix solid-phase dispersion (MSPD) followed by liquid chromatography-atmospheric pressure chemical ionization-mass spectrometry (LC-APCI-MS) in positive-ion mode. The samples were homogenized with C8 bonded silica as MSPD sorbent, placed in a glass column, and eluted with dichloromethane. Chromatographic separation of the compounds was achieved on a reversed-phase LC column using a methanol-ammonium formate (50 mmol L(-1)) gradient as a mobile phase. Samples were screened by monitoring the protonated molecular ion at m/z 256 for imidacloprid, 280 for metalaxyl, 289 for myclobutanil, and 202 for thiabendazole, and the main fragment at m/z 138 for propham. Positive samples were confirmed by multiple-ion monitoring. The repeatability (<20%) and recovery (>57%) of the method were good, and limits of detection (<0.05 mg kg(-1)) were adequate.

Antinematodal Agents↗

Studies on the positive-ion mass spectra from atmospheric pressure chemical ionization of gases and solvents used in liquid chromatography and direct liquid injection.

Detailed studies have been made using different source gases and solvents in a Micromass Quattro mass spectrometer under positive ion atmospheric pressure chemical ionization conditions. The major background ions from nitrogen, air, or carbon dioxide were investigated by tandem mass spectrometry, followed by similar studies on solvents commonly employed in normal- and reversed-phase high-performance liquid chromatography, namely, water-acetonitrile, acetonitrile, and dichloromethane, with nitrogen, air, or carbon dioxide; hydrocarbon solvents were studied using nitrogen. Spectra were interpreted in terms of the gases, solvents, and their impurities. The acetonitrile spectra provided clear evidence for both charge exchange and proton transfer, the former being facilitated by the introduction of some air into a flow of nitrogen. Radical cations of acetonitrile dimers, trimers, and tetramers were observed, as were protonated dimer and trimer species. Examination of the analytical response of four polycyclic aromatic hydrocarbons in various hydrocarbon solvents, with nitrogen gas, showed that the sensitivity of detection for an analyte and its ionization mechanism are dependent on both the analyte structure and the solvent, with pyrene showing the highest sensitivity, phenanthrene and fluorene being intermediate, and naphthalene having the lowest sensitivity. The degree of protonation followed the same trend. Signal intensity and degree of protonation were dependent on the alkane solvent used, with isooctane providing the best overall sensitivity for the sum of protonated molecules and molecular ions. The ions observed in these studies appeared to be the most stable ions formed under equilibrium conditions in the source.

Journal Article↗

A low-power, atmospheric pressure, pulsed plasma source for molecular emission spectrometry.

A low-power, plasma source-based, portable molecular emission detector is described in this paper. The detector employs a pulsed-plasma source operated at atmospheric pressure for molecular fragmentation and excitation. The plasma was generated with a home-built high-voltage pulsed power supply. The average operational power of the detector was less than 0.2 W. The effects of operational parameters such as plasma gas, voltage, and plasma gas flow rate were investigated. Molecular emission spectra of a variety of organic compounds were studied. The features of the emission spectra obtained with the pulsed plasma source were significantly different from those obtained with direct current (dc) discharge at a power higher than 10 W. The spectra obtained in this work showed strong CH emission at 431.2 nm; however, the typical CN emission observed with a conventional dc plasma source at 383-388 nm was very weak in most cases. The strong CN emission was only obtained for compounds containing nitrogen, such as aniline. Dimethyl sulfoxide can be detected at a limit of 200 ppb using helium plasma by observing the emission band of the CH radical. The detector was very stable and did not experience electrode fouling even with the introduction of organic vapors. Such a detector is very promising for organic vapor detection.

Journal Article↗

Quantitative method for analysis of monensin in soil, water, and urine by direct combination of single-drop microextraction with atmospheric pressure matrix-assisted laser desorption/ionization mass spectrometry.

A simple and selective analytical method for the quantitative determination of low concentrations of monensin in soil, surface water, and human urine has been developed. Prior to atmospheric pressure matrix-assisted laser desorption/ionization mass spectrometry (AP-MALDI-MS) analysis, the samples were preconcentrated by using the single-drop microextraction (SDME) technique. Several factors that affect the analyte's extraction, including selection of solvent, microdrop volume, extraction time, and ionic strength, were investigated. Chloroform-toluene (1:1, v/v) was selected as the extraction solvent. Reliable results were obtained using dibenzo-30-crown-10-ether as an internal standard. The proposed method has been successfully applied for the determination of monensin in soil, surface water, and human urine spiked samples. Under the optimized conditions, the limits of quantification of the analyte in surface water, soil, and human urine were 6.7, 12.4 and 7.8 ng/mL, respectively. The intraday and interday precision variation and accuracy of the present method is within the acceptable ranges. The present method avoids the pre- and postderivatization of weak UV absorbing monensin determination using high performance liquid chromatography-ultraviolet detection (HPLC-UV). Furthermore, these techniques are time-consuming, nonreproducible at trace levels, and form undesirable products. The proposed SDME combined with AP-MALDI-MS is simple, fast, and selective for the determination of monensin in environmental and urine samples.

Humans↗

Analysis of plant sterol and stanol esters in cholesterol-lowering spreads and beverages using high-performance liquid chromatography-atmospheric pressure chemical ionization-mass spectroscopy.

Plant sterol and stanol esters were separated on a Luna hexyl-phenyl column using a gradient of acetonitrile (90-100%) in water. The eluted compounds were detected by atmospheric pressure chemical ionization (APCI)-mass spectroscopy (MS) in the positive mode. Sterol and stanol esters produced [M + H - HOOCR](+) ions. Application of the hyphenated technique-LC-MS-allowed differentiation between a number of esters of sitosterol, campesterol, stigmasterol, and (tentatively) avenasterol, as well as sitostanol and campestanol esters. With cholesteryl decanoate used as the internal standard, the method showed good linearity, precision, and reproducibility. The method required minimal sample pretreatment and can be applied to samples with high water content (juices) as well as samples with high oil content (margarine spreads). The method could be useful for the analysis of sterol and stanol esters in fortified food products.

Anticholesteremic Agents↗