PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Angiography, Digital Subtraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35Linked to original sources

[Congenital and acquired anomalies of the inferior vena cava. Differential diagnosis using digital subtraction angiography and computed tomography].

Segmental aplasias of the inferior vena cava, thrombosis of the vena cava, tumour infiltration (e.g. renal neoplasms via the renal vein) and external compression (e.g. large hepatic metastases) may produce similar radiomorphologic changes in chest x-ray DSA and CT. These radiomorphological changes are described by case reports. DSA clearly demonstrates the course of the vessels and the collaterals involved. CT may elucidate the paracaval vascular changes. It is only a synopsis of cavography (DSA) and CT with reference to embryogenesis that will lead to a reliable diagnosis and enable a definite decision on therapy and prognosis.

Adolescent↗

Automation system of X-ray filter in digital subtraction angiography.

A newly developed automation system for making X-ray filter in DSA was applied to clinical study. A low-dose test exposure image of the patient was input to a computer as a template. The image was scaled down and used to engrave the X-ray filter shape on a polystyrene foam block with a modeling machine according to the image data. The carved part was filled with barium paste, and the block was placed on the tube as an X-ray filter. In this study, the system contributed to make a patient-specific filter of sufficient amount of attenuation in a short time. Also, it could avoid the unreasonable exposure of the patient during the preparation of the filter.

Angiography, Digital Subtraction↗

Anatomically tailored k-Space sampling for bolus-chase three-dimensional MR digital subtraction angiography.

The purpose of this study was to evaluate a variable k-space sampling method for bolus-chase three-dimensional magnetic resonance digital subtraction angiography in the arterial system from the abdomen to the calf. Imaging time was minimized by tailoring the acquisition according to the vascular anatomy of the station. For images obtained in 30 patients, results with the modified protocol were compared to those with the previously published protocol. For all stations, significant improvement (P <.001) was found with the modified protocol.

Adult↗

A comparison of intra-arterial digital subtraction angiography with Doppler sonography in the assessment of carotid arterial stenosis.

A comparison is made of the use of selective intra-arterial subtraction angiography and doppler sonography in the assessment of disease in 206 carotid arteries. Maximal stenoses in each of the internal, external and common carotid arteries were recorded and compared using both modalities. In 93% of cases, arteries reported as normal ultrasonically were also found to be normal on angiography. However, agreement between the modalities in the assessment of severe stenoses was rather less at 79%. Overall agreement between the two modalities was good using statistical analysis (weighted Kappa). It is our view that ultrasound is reliable in normal vessels, but where significant disease is present the rate of error between the two modalities is too high to warrant omission of angiography.

Angiography, Digital Subtraction↗

[Is intravenous digital subtraction angiography sufficient for planning radiologic interventions in acute and chronic arterial obstructions of the pelvis and leg vascular systems?].

The therapeutical procedure in acute and chronic arterial obstructions of the pelvic and upper leg arteries may often be based on the results of intravenous DSA (i.v. DSA). In patients with peripheral arterial disease and before interventions below the knee are contemplated, i.v. DSA is not sufficient and has to be replaced by arterial DSA (IA DSA). I.v. DSA facilitates technical planning and performance of radiological vascular interventions and has the potential to reduce the complication rates. Nevertheless, the definitive decision to perform PTA and the choice of the appropriate technique continue to be made on the results of the arteriography/i.a. DSA, which has to be routinely obtained at the beginning of any procedure.

Angiography, Digital Subtraction↗

[Preliminary evaluation of diagnostic usefulness of digital subtraction angiography (DSA) in the diagnosis of brain diseases].

On the ground of an analysis of 64 patients the authors present their opinion on the clinical usefulness of digital subtraction angiography in the diagnosis of cerebrovascular diseases. It is believed that this method provides in most cases information which are not necessary to be confirmed by other methods. Digital angiography has a lower resolution ability than conventional angiography but is less invasive and may be presently a good screening or control technique.

Adult↗

Carbon dioxide (CO2) digital subtraction angiography: 26-year experience at the University of Florida.

Although the vascular system is presently being imaged by multiple high technology modalities, contrast angiography continues to be the gold standard; however, severe complications rarely occur. During the last 25 years (in over 1400 patients), CO2 has proven to be extremely safe (no allergy or renal failure). However, it is imperative to understand CO2's physical properties and potential dangers. Recently, CO2 is being routinely utilized not only because of safety, but for detection of minute amounts of bleeding, better collateral filling, and for most interventional procedures since unlimited volumes of CO2 can be injected between the catheter and guidewire. Presently, safe, reliable and "user-friendly" delivery systems are now commercially available. CO2 DSA images are now nearly comparable to iodinated contrast, and improvement in DSA images are evolving, including "stacking" software.

Acute Kidney Injury↗

[Non-selective digital subtraction angiography of aortocoronary bypasses].

Intra-arterial DSA was performed on 225 patients with a total of 552 coronary bypasses (515 aorto-coronary venous bypasses and 37 internal mammary artery bypasses). Four hundred and ninety-five bypasses were examined in the four weeks following surgery; of these, 428 (85.9%) were patent. Demonstration of the distal anastomosis was obtained in 40.4% of bypasses of the right anterior interventricular artery and in 36.1% of the right coronary artery, at least in their proximal parts. Bypasses of smaller branches showed filling in 12.8 to 19.2%. Because of the unsatisfactory demonstration of distal vessels by non-selective intra-arterial DSA, this method is suitable only for showing the patency of a bypass in the postoperative phase, but should not be used for investigating cardiac signs and symptoms following a bypass examination.

Adult↗

Gadolinium dimeglumine: an alternative contrast agent for digital subtraction angiography.

The aim of this study was to evaluate gadolinium diethylenetriaminepenta-acetic acid (Gd-DTPA) as an alternative contrast agent for digital subtraction angiography (DSA) in patients with renal insufficiency or previous anaphylactic reaction to iodinated contrast agents. We performed 34 DSAs in 31 patients by use of the commercially available 0.5-M Gd-DTPA solution (Magnevist, Schering, Berlin, Germany). The contrast material was power- or hand-injected at the same rate as iodinated contrast material, without exceeding a total amount of 0.4 mmol/kg body weight. In 18 studies Gd-DTPA was the sole contrast agent. In 9 cases gadolinium injections were combined with carbon dioxide. Restricted non-ionic contrast medium injections were administered to complete the examinations in 7 cases and for comparative purposes in 1 case. Cerebral and carotid arteries, one superior limb, abdominal aorta, renal arteries, renal transplants, iliac arteries and inferior limbs were imaged, and ten endovascular interventional procedures, including three transjugular intrahepatic percutaneous stent shunts, were performed. No side effects were observed. Diagnostic angiographic images were obtained in all cases except in 5 of the 8 distal run-off studies. Gadolinium-based contrast can produce clinically useful angiograms in patients with a contra-indication to iodine who must undergo angiography.

Angiography, Digital Subtraction↗

[Technique and value of digital subtraction angiography in erectile dysfunction].

Arteriography of penile arterial supply is of decisive importance in the diagnostic evaluation of arteriogenic impotence. Technique and results of penile arteriography by means of high-resolution DSA in 26 impotent men are reported. In comparison to direct serial angiography on large-scale films, high-resolution DSA with 1024(2)-matrix provides the advantages of reduced investigation-time and reduction of contrast media load. Additional detailed views in different projections can be easily obtained. In 15 of 26 patients (mean age 54.9 years) a total of 34 steno-occlusive vessel changes were found (57.7%). 65.4% showed anatomic variations. In all patients, DSA provided clear vascular diagnosis. Thus, additional large-scale serial filming never became necessary. Results are comparable to those reported by other authors. In conclusion, high-resolution DSA can completely replace large-scale serial angiography in the evaluation of penile arterial supply.

Angiography, Digital Subtraction↗

CO2 spray mini-injector for digital subtraction angiography versus PC-controlled injection system: experiments in dogs.

A personal computer (PC)-controlled CO2 injector (consisting of a pneumatic unit, electric/electronic system, and calculator) and a spray mini-injector (consisting of a CO2 spray can and a dosage chamber) were used in 10 dogs to determine their efficacy regarding imaging quality and ease of handling. CO2 was injected into the abdominal aorta, renal artery, and femoral artery. The vessel diameter was determined on each CO2 arteriogram and compared with that determined on a reference arteriogram obtained using an iodinated contrast agent. The filling ratio (CO2/iodine) was calculated for each set of injection parameters. Both injection systems provided good visualization (filling ratio > 0.9) of large and small arteries within a range of injection parameters. In terms of practicality, the spray mini-injector is more appealing, because it is easier to handle and does not require any preparation.

Aerosols↗

[Carbon dioxide--contrast medium for digital subtraction angiography].

UNLABELLED: Fundamental considerations: Despite appreciable improvements in conventional iodine-containing contrast media, vascular studies involving patients with renal insufficiency, hyperthyroidism or known allergic reaction to conventional contrast media continue to pose a problem. Own study: Testing the investigation of the possibility of visualizing vessels using carbon dioxide as a gaseous contrast medium. In 30 patients, angiography of the pelvis and legs (DSA) employing conventional iodine-containing media and/or CO2 were carried out simultaneously. RESULTS, handling and toleration were compared. In two further patients, percutaneous transluminal angioplasty and stent implantation, respectively, were successfully performed under CO2 control. RESULTS: All the findings obtained with "normal" DSA were also obtainable with CO2. The CO2 examination, however, was often plagued by incomplete contrasting of the blood vessels, with interruption of the contrast medium column, which made assessment more difficult. In two of the 30 patients undergoing angiography of the pelvis and legs, the investigation had to be abandoned on account of persistent intensive lower abdominal pain under CO2 injection.

Angiography, Digital Subtraction↗

Distortion correction for digital subtraction angiography imaging: PC based system for radiosurgery planning.

We report, the development of a personal computer (PC) based system to correct distortion of digital subtraction angiography (DSA) images. The program was written in INTERACTIVE DATA LANGUAGE (IDL) and implemented on a PC equipped with an Intel Pentium III 450 MHz CPU in the MICROSOFT WINDOWS 98 environment. The system consists of two modules. The coefficient calculation module detects distortions of grid phantom images automatically and determines the distortion correction function. An additional distortion correction module corrects detected distortion using the correction function determined by the coefficient calculation module. The correction program can be used for images taken at arbitrary lateral oblique angle, and about 4 min are required to correct an image. The correction program was verified using phantom and clinical images. After image correction, the root mean square (rms) deviations of the reference points of each image were calculated. The average value of the rms deviation of all phantom images was about 0.1 mm. The residual mean rms deviation of the corrected clinical images (0.34+/-0.19 mm) and maximum error (0.59+/-0.26 mm) were within the acceptable limits of stereotactic radiosurgery. The accuracy, the ability to process lateral oblique angles, and reasonable program running time makes the developed system a valuable tool in clinical practice, for example for the planning of gamma knife radiosurgery.

Angiography, Digital Subtraction↗

[Methodologic aspects of digital subtraction angiography].

The paper is concerned with retrospective analysis of investigations of 1000 patients for standardization of the methodology of computerized subtraction angiography (CSA). Intravenous injection of a contrast medium for visualization of various parts of the arterial system was performed in 374 patients, a selective contrast study of the arteries and veins--in 626. Optimum regimens of injections of a contrast medium, the rate of injection with respect to the site of drug administration, the internal section and length of a catheter were determined. Correlation between a single dose of injection of a contrast medium and the patient's body mass during i. v. CSA was determined. Shortcomings of the method and possibilities for their elimination were mentioned. Some methodological procedures for CSA optimization (a possibility of correlation of the detected changes with anatomical structures and the determination of their actual sizes irrespective of the size of an image obtained) were proposed.

Angiography, Digital Subtraction↗

Comparison of high-resolution contrast-enhanced 3D MRA with digital subtraction angiography in the evaluation of hepatic arterial anatomy.

AIM: To evaluate the validity of high-resolution contrast-enhanced three-dimensional magnetic resonance angiography (MRA) in defining hepatic arterial anatomy and to compare this with digital subtraction angiography (DSA). MATERIALS AND METHODS: MRA and DSA were performed in 30 patients. MRA was performed with breath-hold, gadolinium-enhanced, three-dimensional, fast low-angle shot sequence with a 512 pixel matrix. MRA was compared with DSA in terms of image quality and depiction of hepatic arterial anatomy. The agreement in image quality between MRA and DSA was determined with the kappa statistic. RESULTS: With respect to image quality, there was excellent or good correlation between MRA and DSA for the common hepatic artery (kappa=0.85), proper hepatic artery (kappa=0.72), gastroduodenal artery (kappa=0.70), left hepatic artery (kappa=0.49), left gastric artery (kappa=0.50), splenic artery (kappa=0.84), and superior mesenteric artery (kappa=0.88). Poor correlation was found for the right hepatic artery (kappa=0.18) and right gastric artery (kappa=0.38). With regard to hepatic arterial anatomy, MRA correlated correctly with DSA in 28 of the 29 cases, i.e. 97% of patients. CONCLUSION: MRA is a useful technique for the evaluation of the hepatic artery, and for the vast majority of patients, MRA can replace intra-arterial DSA.

Aged↗

[The accuracy of intravenous digital subtraction angiography regarding kidney arteries in hypertensive patients. A contribution to cost control in diagnostic medicine].

In a retrospective study the results of intravenous digital subtraction angiography (DSA) of renal arteries from 149 hypertensive outpatients investigated 1984 to 1989 at the University of Berne were evaluated. 118 i.v. DSA's (79%) were normal, 10 (7%) were inconclusive and 21 (14%) revealed stenosis. In 16 patients the course of the vessel and the degree of stenosis were verified by intraarterial DSA. In nine patients (6%) a significant stenosis was confirmed and subsequently treated by percutaneous transluminal angioplasty. Renal size was not a predictive parameter for stenosis in this population. Accessory renal arteries were found in 44% of patients with stenosis and only in 18% of those without. The late phase images of i.v. DSA revealed many morphologic abnormalities. The indication for i.v. DSA was assessed according to internationally accepted criteria: 1. severe hypertension, 2. hypertension refractory to treatment, 3. hypertension of sudden onset or aggravation, 4. onset of hypertension in patients younger than 20 or older than 50 years. In the group without stenosis (n = 118) 52 patients (44%) did not fulfill a single one of these criteria, whereas the patients with stenosis (n = 9) had at least one criterion fulfilled. Hypertensive patients should, therefore, only be studied by i.v. DSA if at least one criterion applies. 22,000 SFr. could thus have been saved without loss of medical quality and the treatment options.

Angiography, Digital Subtraction↗

Intra-arterial administration of fasudil hydrochloride for vasospasm following subarachnoid hemorrhage - analysis of time-density curve with digital subtraction angiography.

The cerebral circulatory dynamics were evaluated before and after intra-arterial administration of fasudil hydrochloride in 20 patients with angiographic vasospasm after subarachnoid hemorrhage (SAH). The region of interest time-density curves obtained before and after intra-arterial administration of fasudil hydrochloride were compared in the proximal portion of the middle cerebral artery in the early arterial phase, the distal portion of the middle cerebral artery in the late arterial phase, and the transverse sinus in the venous phase. In the early arterial phase, the time to peak and the time to half-peak were significantly reduced. In the late arterial phase and venous phase, the time to peak was significantly reduced. These results suggest that intra-arterial administration of fasudil hydrochloride induced dilation of the proximal arteries, and improved cerebral microcirculation. The present study suggests that intra-arterial administration of fasudil hydrochloride is effective as a treatment for vasospasm following SAH.

1-(5-Isoquinolinesulfonyl)-2-Methylpiperazine↗

[Diagnostic imaging following reconstructive surgery of the arteries of the legs. Angiodynography versus digital subtraction angiography].

Fifty-three patients were examined by angio-dynography and angiography in a prospective study following vascular surgery of the lower extremities. The question of patency was correctly solved in all cases. A-V communications could be localised in eight out of nine cases. Evaluation of anastomoses is equally accurate by both methods; all angiographically demonstrated stenoses were also visible on sonography. Aneurysms at the anastomoses and peri-vascular fluid collections were better shown by angio-dynography, as might have been expected. The demonstration of the distal run-off, following femoro-crural bypass, presented a problem; in eight cases this could not be achieved because of technical difficulties. Surprisingly, angio-dynography proved superior in demonstrating large distal A-V shunts. Our experience so far indicates that angio-dynography may be used as an alternative to angiography for certain specific indications (bypass patency, large A-V shunts and complications around the anastomosis). Demonstration of vessels, and particularly of distal femoral bypasses can be improved by using the "slow-flow technique".

Adolescent↗