The size of occlusal rest seats prepared for removable partial dentures.

OBJECTIVE: The aim of this study was to test whether rest seats cut by a group of general dental practitioners for a removable partial denture differed in size and shape from those prepared by either a group of postgraduate students or their academic teachers. METHOD: The occlusal surfaces of a number of plastic teeth were scanned by a laser profilometer. Each tooth was then placed in a set of articulated phantom head dental arches. 30 dental practitioners, 16 postgraduates and 11 dental academics were asked to cut a rest seat preparation in the mesial marginal ridge suitable for the construction of a removable chromium cobalt partial denture. The tooth was removed from the models, rescanned, and this data converted to grey level images for measurement of the width, length and area of each rest seat. Depth was calculated as the difference between the pre and post preparation scanned profiles. RESULTS: There was a wide variation in the size of the individual rest seat preparations. There was no significant difference between the measured parameters from the images of the preparations made by academic staff and postgraduate students. The two sets of data were therefore combined. The length, width and area of the rest seats prepared by the staff and postgraduate group were significantly greater than those cut by the dental practitioner group. However, there was no significant difference in the depths measured. The outline form of the rests prepared by the dental practitioners was often round with sharply defined margins contrasting with the smooth triangular preparation the staff and postgraduates prepared. CONCLUSION: A 'refresher' in tooth modification for GDPs designing partial dentures would improve the long term success of the prosthesis.

Clinical Competence↗

Prosthetic use of carbon fiber-reinforced epoxy resin for esthetic crowns and fixed partial dentures.

The traditional alloys used as metal bases for fixed partial dentures are accompanied by various problems such as corrosion, allergy, toxicity, casting, and preparation for both patient and prosthodontist and in magnetic resonance imaging for diagnosis. A DGEBA-DDM type polyepoxide resin and carbon fibers composite has been introduced that addresses some of these considerations. A three-part study of the clinical behavior of a limited number of prostheses has shown positive results confirming the biofunctional capacity of polyepoxy-carbon materials and their gingival biocompatibility.

Carbon↗

Flexion characteristics of four-unit fixed partial denture frameworks using holographic interferometry.

Flexion of a metal/ceramic fixed partial denture (FPD) framework under function can cause fracture of the porcelain or deterioration of the cement seal. This study evaluated the flexion under compressive load of a four-unit mandibular FPD replacing the second premolar and the first molar. Testing was accomplished with elapsed time holographic interferometry, using 39 porcelain fused-to-metal frameworks cast with a silver-palladium alloy. The results demonstrated that solder joints at the junction of the premolar and molar pontics flexed under a reduced compressive load and exhibited a higher failure rate than other connector designs.

Analysis of Variance↗

In vitro deformation of acetyl resin and metal alloy removable partial denture direct retainers.

STATEMENT OF THE PROBLEM: Acetyl resin removable partial denture (RPD) direct retainers may provide an esthetic alternative to conventional metal direct retainers. The effect of repeated stress on acetyl resin direct retainers is unknown. PURPOSE: This study compared deformation of acetyl resin and metal alloy RPD direct retainers after repeated dislodgments over a test die. MATERIAL AND METHODS: Ten acetyl resin (Thermoflex) and 10 metal alloy (Ticonium Premium 100) RPD direct retainers, fabricated to manufacturers' specifications, were dislodged over a stainless steel die by means of a laboratory test apparatus for a simulated 3-year period (5000 cycles). Occlusal and facial digital images made before and after cycling were measured (mm) for direct retainer deformation by using computer-imaging software (Scion Image 1.62). Student t tests (alpha=.05) were performed for statistical comparisons. RESULTS: A significant difference in deformation between acetyl resin and metal alloy direct retainers occurred in the occlusal view (P=.045), but not in the facial view (P=.832). Average deformation varied but was greatest in the occlusal view: 0.09 +/- 0.8 mm for acetyl resin direct retainers compared with 0.01 +/- 0.9 mm for metal alloy direct retainers. Average facial view deformations revealed no significant differences: 0.039 +/- 0.6 mm for metal alloy and 0.033 +/- 0.7 mm for acetyl resin direct retainers. CONCLUSION: Within the limitations of this in vitro study, significantly greater deformation resulted with acetyl resin compared with metal alloy direct retainers after 3 years of simulated use.

Dental Alloys↗

Stress distribution in fiber-reinforced composite inlay fixed partial dentures.

STATEMENT OF PROBLEM: Fiber-reinforced composite inlay fixed partial dentures (FRCIFPDs) may be a reliable prosthetic solution. Clinical procedures involved in their fabrication have been defined, but little is known about their mechanical behavior. PURPOSE: This in vitro study used the finite element (FE) method to investigate 3-dimensional (3-D) stress and strain distribution produced in a 3-unit FRCIFPD. MATERIAL AND METHODS: A 3-D FE model (227,768 3-D tetrahedral elements) of a 3-unit FRCIFPD cemented onto box-shaped prepared teeth was developed. Stress and strain distribution generated by a maximum load of 196 N applied vertically or laterally to the FRCIFPD centrally, on an area of 4 +/- 0.1 mm 2 , was analyzed. The specimen used to acquire the geometry of the model was also used for mechanical compressive tests, with vertical and lateral loads, to validate the numerical model. RESULTS: The peak values of stress, calculated on the outer and inner surfaces of the FRCIFPD, were localized in the connector areas. When a vertical load was applied, stress on the prepared teeth was concentrated at the cervical margin of the abutment preparation. CONCLUSION: Within the limitations of this in vitro study, the results suggest that within the FRCIFPD, stress concentrates at the connector areas, and that in the prepared teeth, peak stress is at the cervical margin of the box of the preparation.

Acrylic Resins↗

Effect of connector design on the fracture resistance of all-ceramic fixed partial dentures.

STATEMENT OF PROBLEM: Fracture of all-ceramic fixed partial dentures (FPDs) tends to occur in the connector area. PURPOSE: The objective of this study was to test the hypothesis that the radii of curvature at the connector affects the fracture resistance of 3-unit FPDs. MATERIAL AND METHODS: With the use of a standardized silicone mold, 40 three-unit FPD wax patterns were fabricated with the same dimensions and divided into 4 groups of 10 specimens per group. Each pattern was modified at the connector areas of the occlusal embrasure (OE) and the gingival embrasure (GE); 2 wax carvers with radii of curvature at their tips of 0.90 mm and 0.25 mm were used. The dimensions of the connectors were standardized with an electronic caliper to 4 +/- 0.12 mm in height and 5 +/- 0.13 mm in width. Connector designs were as follows: Design I: OE and GE 0.90 mm; Design II: OE 0.90 mm and GE 0.25 mm; Design III: OE 0.25 mm and GE 0.90 mm; and Design IV (control): OE and GE 0.25 mm. An experimental hot-pressed core ceramic was used to make the FPD frameworks, which were consequently cemented on epoxy dies with dual-polymerizing composite (Variolink II) and loaded to fracture in a universal testing machine at a crosshead speed of 0.5 mm/min. The failure load data were analyzed with analysis of variance (ANOVA; P=.05) and Duncan's test (alpha=.01). RESULTS: The mean failure loads and standard deviations were as follows: 943 +/- 151 N for Design I; 746 +/- 106 N for Design II; 944 +/- 144 N for Design III; and 673 +/- 55 N for Design IV. ANOVA revealed a significant difference (P< or = .0001) between the mean failure loads of different connector designs. The mean loads to failure for Designs I and III were significantly higher than those for Designs II and IV (Duncan's test). CONCLUSION: Within the limitations of this study and for the experimental ceramic tested, as the radius at the gingival embrasure increased from 0.25 to 0.90 mm, the mean failure load increased by 140%. The radius of curvature at the occlusal embrasure had only a minor effect on the fracture susceptibility of 3-unit FPDs.

Analysis of Variance↗

Effectiveness of computer-aided removable partial denture design.

PURPOSE: Computer programs have been developed for removable partial denture (RPD) design, but their educational impact has never been investigated. This study measured the effectiveness of computer-based RPD design simulations in a traditional RPD design course for second-year dental students. MATERIALS AND METHODS: Thirty-six students were randomly assigned to four groups, two simulation and two control groups, at the beginning of the RPD design module. A cross-over design compared the two strategies during laboratory exercises. First, the simulation group worked with the simulation, while the control group met in small-group seminars with faculty. Post-test 1 was given, and then students switched teaching methods and post-test 2 was given. Each post-test had two parts. Part 1 involved designing an RPD based on specific patient criteria. Part 2 involved choosing the more correct of the two designs. RESULTS: Results showed a significant difference (p = .0072) in two of four test groups. Although it was an initial evaluation, the computer simulation was shown to be equivalent to faculty-led small-group seminars. Students also responded positively to a questionnaire on their perceived effectiveness of the simulations. CONCLUSIONS: The results suggest that RPD design can be taught as effectively with computer-based simulations as with faculty-led seminars.

Computer-Aided Design↗

Clinical considerations in case selection for all-ceramic fixed partial dentures.

All-ceramic systems have been utilized for fixed partial dentures (FPDs) to replace a missing tooth since the early 1990s. Clinical studies that assess the long-term outcome of both anterior and posterior three-unit all-ceramic FPDs are required to determine whether they can serve as a viable treatment option for functional and aesthetic tooth replacement. This article discusses the evolution and development of all-ceramic systems for FPDs as well as the clinical and laboratory considerations for treating patients using these restorations.

Adult↗

Reproducibility of interocclusal recording for mandibular removable partial denture in bilateral distal extension cases.

Interocclusal recording for removable partial denture in bilateral mandibular distal extension were evaluated for the differences of the interocclusal recording material utilized during different impression techniques. The purpose of this study is to develop interocclusal recording utilizing occlusion rims with high accuracy. The intraoral model with urethane rubber mucosa with 3 metallic spheres as measuring points was utilized. With the applied pressure (functional) and minimum pressure (anatomical) impression techniques, working casts were fabricated. Interocclusal recording was registered with the occlusion rim on the intraoral model unto the articulator by applying the interocclusal materials; paraffin wax (PW), ALUWAX (AW), impression paste (IP) and Exabite II (EB). Analyses were conducted with the three-dimensional analyzer and calculated for the amount of vertical and antero-posterior displacement between the intraoral model and the working cast. The results were that PW had the greatest displacement, especially with the functional impression technique, while AW had minimum displacement especially in the posterior direction. With the functional impression technique utilizing AW was revealed to minimize the amount of interocclusal displacement.

Analysis of Variance↗

[Presentation of an expert system for planning partial dentures].

An expert system for treatment planning in cast clasp partial denture cases is presented. The system may be used both to verify the construction principles of proposed clasp constructions and to develop new constructions. At first, it is intended to use this expert system for teaching in university dental schools.

Dental Clasps↗

RLS--the lingually retained clasp assembly for distal extension removable partial dentures.

The design of clasp for a distal extension removable partial denture that helps preserve both the abutment teeth and the tissues of the edentulous ridge is described. The clasp assembly takes advantage of surveyed lingual undercuts to provide support, retention, and stability. It consists of a mesio-occlusal rest, a distolingual L-bar direct retainer that is located on the abutment tooth adjacent to the residual ridge, and a distobuccal stabilizer (RLS).

Denture Design↗

[Clinical results of partial denture anchorage using extracoronal bonded attachments].

16 caries-free partially edentulous patients were treated with 36 extracoronal adhesive attachments to support 4 removable partial dentures in the upper and 14 in the lower jaw. The cast nonprecious metal retainers were electrochemically etched and bonded with Superbond to the prepared abutment teeth. No debonding of the retainer occurred during the incorporation time of maximal 52 and minimal 3 months.

Adhesives↗

Removable partial denture with a lateral rotational path of insertion.

A removable partial denture with a lateral path of insertion is useful when unsightly facial clasps are objectional to the patient. Rounded rest seat preparations allow extensions of the minor connector to rotate laterally into embrasure undercuts, providing retention. Guiding planes on the contralateral side ensure a different path of withdrawal from the retentive elements. A Kennedy Class IV arch with a long edentulous span is used to illustrate the denture design.

Dental Clasps↗

[A comparative study of masticatory efficiency between partial denture wearers having one remaining tooth and complete denture wears]

Masticatory efficiency is one of the important indexes of judging masticatory function after dentures restored.The aim of this study was to measure and analyze masticatory efficiency of partial dentur wearers having one tooth left and complete denture wearers,by using a method of measuring msticatory crushed granules.The results showed that the crushed granules for partial denture wearers with one remaining tooth were smaller than that for complete ones.Therefore,partial dentures with a few remaining teeth were better than complete ones on effects.

Journal Article↗