The dose-response of Harshaw TLD-700H.

Harshaw TLD-700H (7LiF:Mg,Cu,P) was previously characterised for low- to high-dose ranges from 1 microGy to 20 Gy. This paper describes the studies and results of dose-response and linearity at much higher doses. TLD-700H is a near perfect dosimetric material with near tissue equivalence, flat energy response, and the ability to measure beta, gamma and X rays. These new results extend the applicability of Harshaw TLD-700H into more dosimetric measurement environments. The simple glow curve structure provides insignificant fade, eliminating special oven preparation methods experienced by other materials. The work presented in this paper quantifies the performance of Harshaw TLD-700H in extended ranges.

Computer Simulation↗

Energy response of a two-dimensional sheet-type LiF:Mg,Cu,P TL dosemeter to photons.

A 2-D tissue-equivalent sheet-type dosemeter (NTL sheet) was developed using thermoluminescent material of LiF:Mg,Cu,P (NTL-250). The energy responses of the NTL sheet and NTL-250 powder were measured with 10-150 keV monoenergetic photons from synchrotron radiation at SPring-8. The sample was irradiated by a rotational method for the uniform irradiation with the narrow beam. Linearity of the NTL-250 was confirmed up to 2 Gy. Energy responses of the NTL sheet and NTL-250 powder were close to that of soft tissue. On the other hand, the BaSO(4) sheet, which has been used practically, showed the response that the sensitivity approximately 60 keV was 100 times higher than that for (60)Co gamma rays. Therefore the NTL sheet can be said to have excellent properties for dose measurements.

Copper↗

LiF:Mg,Cu,P glow curve shape dependence on heating rate.

The glow curve shape of LiF:Mg,Cu,P (MCP) material is studied in this research. The study is focused on the effects of the heating rate on the dosimetric peaks. Different configurations of dosemeters (chips, cards and powder) are studied. The shifting of the dominant dosimetric peak is observed and analysed. The curves are deconvoluted using the new Harshaw Glow Curve Analyser (GCA) program. Results of the study are presented, as well as possible explanations as to the observed effects.

Computer Simulation↗

Angular and radial dependence of the energy response factor for LIF-TLD micro-rods in 125L permanent implant source.

EGSnrc Monte Carlo simulations were used to calculate the angular and radial dependence of the energy response factor for LiF-thermoluminescence dosemeters (TLDs) irradiated with a commercially available (125)I permanent brachytherapy source. The LiF-TLDs were modelled as cylindrical micro-rods of length 6 mm and with diameters of 1 mm and 5 mm. The results show that for a LiF-TLD micro-rod of 1 mm diameter, the energy response relative to (60)Co gamma rays is 1.406 +/- 0.3% for a polar angle of 90 degrees and radial distance of 1.0 cm. When the diameter of the micro-rod is increased from 1 to 5 mm, the energy response decreases to 1.32 +/- 0.3% at the same point. The variation with position of the energy response factor is not >5% in a 6 cm x 6 cm x 6 cm calculation grid for the 5 mm diameter micro-rod. The results show that there is a change in the photon spectrum with angle and radial distance, which causes the variation of the energy response.

Brachytherapy↗

Comparative study of LiF:Mg,Cu,Na,Si and Li2B4O7:Cu,Ag,P TL detectors.

Recently, two new types of 'tissue equivalent' thermoluminescent detectors (TLDs) have aroused attention: LiF:Mg,Cu,Na,Si and Li2B4O7:Cu,Ag,P. In this work the characteristics of both detectors were compared with the characteristics of the well-known type LiF:Mg,Ti detector, TLD-100. The following properties were investigated: the glow curve structures, relative sensitivity, batch homogeneity and uniformity, detection threshold, reproducibility of the response, linearity in the wide dose range and fading. Also, the energy dependence for medium and low energy X rays was determined in the range of mean energies between 33 and 116 keV. The results confirmed 'tissue equivalency' of both new types in the investigated range of photon energies. LiF:Mg,Cu,Na,Si detector has very high sensitivity (approximately 75 times higher than that of TLD-100) and is convenient for use in a very low range of doses. Li2B4O7:Cu,Ag,P detector shows some improvements in comparison with the previously prepared types of lithium borate. The most important is the five times higher sensitivity than that of TLD-100. This detector is also very promising, especially in medical dosimetry.

Borates↗

Tissue-equivalent TL sheet dosimetry system for X- and gamma-ray dose mapping.

To measure dose distribution for X- and gamma rays simply and accurately, a tissue-equivalent thermoluminescent (TL) sheet-type dosemeter and reader system were developed. The TL sheet is composed of LiF:Mg,Cu,P and ETFE polymer, and the thickness is 0.2 mm. For the TL reading, a square heating plate, 20 cm on each side, was developed, and the temperature distribution was measured with an infrared thermal imaging camera. As a result, linearity within 2% and the homogeneity within 3% were confirmed. The TL signal emitted is detected using a CCD camera and displayed as a spatial dose distribution. Irradiation using synchrotron radiation between 10 and 100 keV and (60)Co gamma rays showed that the TL sheet dosimetry system was promising for radiation dose mapping for various purposes.

Biomimetics↗

Time-resolved spectroscopy of LiF:Mg,Cu,P.

Time-resolved spectroscopy measurements of LiF:Mg,Cu,P luminescence are presented to obtain a better understanding of the emission characteristics of this material. The intensities and decay of the emission bands were studied as a function of annealing temperature and ionising radiation (gamma) dose. Two peaks in the emission were observed at 367 and 466 nm when excited by the 266 nm laser radiation. The luminescence spectrum under band-to-band X-ray excitation shows a dominant emission approximately 390-400 nm, which resembles the reported thermoluminescence emission and is clearly different from the spectrum obtained using the 266 nm pulsed laser excitation. Annealing of the material to 300 degrees C increases the intensity of the 367 and 466 nm emission bands by an order of magnitude as well as changes the relative intensity of the bands. Additional emission bands, which are not evident in the thermoluminescence emission spectra, are seen at longer wavelengths that also increase with dose. Possible explanations for the observed emission spectra are discussed in this paper.

Computer Simulation↗

Comparison of two extremity dosemeters based on LiF:Mg,Cu,P thin detectors for mixed beta-gamma fields.

Two types of thin LiF:Mg,Cu,P detectors, GR-200F and MCP-Ns, have been characterised for use in the design of an extremity dosemeter for mixed beta-photon radiation fields. Both detectors consist of an extremely thin layer of sensitive material with effective thicknesses of 5 and 8 mg cm(-2), respectively, held in a 5 mg cm(-2) PVC ring holder. Dosimetric performance was analysed according to the ISO 12794 standard and compared with 240 mg cm(-2) TLD-100 measurements. In particular, the energy response was obtained for ISO narrow X-ray spectra, (137)Cs, (60)Co, (204)Tl and (90)Sr/(90)Y. From these measurements a mean calibration factor was calculated to estimate H(p)(0.07). Subsequently, the performance of the dosemeters was checked for a set of 10 different mixed photon and beta-photon fields. The study shows that the proposed dosemeters can estimate H(p)(0.07) in a wide range of mixed beta-photon fields with a maximum deviation from the given dose of 30% and an overall uncertainty of the order of 25% (k = 1). However, the results also highlight a large variability among the different thin detectors and, thus, the standard TLD-100 material is recommended whenever the workplace does not include low-energy beta radiation.

Beta Particles↗

Modelling the dose response of peaks 4, 5 and 5b, in TLD-100, as a function of recombination temperature.

This investigation focuses on whether the experimentally observed changes, in supralinearity f(D) as a function of recombination temperature, can be, successfully, predicted by the Unified Interaction Model (UNIM). To resolve this question, the measurement of f(D) has been carried out for glow peaks 4, 5 and 5b in LiF:Mg,Ti (TLD-100) at two different heating rates and UNIM analysis is used in an attempt to arrive at a consistent/physically reasonable explanation of all the f(D)/heating rate data for the three glow peaks. It is demonstrated that in addition to the variation in the luminescence and competitive centre capture cross section with temperature changes in the ks (the geminate recombination coefficient) parameter as a function of temperature is also required in order to predict the changes in f(D).

Computer Simulation↗

Theoretical and experimental investigation of the f(D)max-(S/S0)max anomaly in LiF:Mg,Ti.

Previous investigations in the framework of the Unified Interaction Model (UNIM) have demonstrated the difficulty in theoretically predicting both f(D)max and [S(Ds)/S(0)]max with the same set of UNIM parameters. This anomaly is re-investigated and an alternative explanation, based on experimental measurements combined with UNIM analysis, is given. This explanation is based on the assumption that N(LC), the total number of available luminescent centres is changed by the sensitisation dose or anneal or both. Allowing N(LC) to increase as the sensitisation dose is increased, a good fit to both f(D) and S(Ds)/S0 is obtained.

Artifacts↗

Optical excitation of LiF:Mg,Ti following alpha and beta irradiation.

It is demonstrated experimentally that optical excitation of irradiated LiF:Mg,Ti (TLD-100) by 4 eV photons has the same effect for both alpha particle (high-ionisation density) irradiation and photon/electron irradiation. In both cases, peak 5a converts to peak 4 causing peak 4 to increase following the bleach. Such an observation is consistent with the major premise of track structure theory that radiation effects following heavy changed particle (HCP)/neutron irradiation are due exclusively to the interaction of the secondary electrons created by the HCP slowing down.

Alpha Particles↗

Thermoluminescence emission spectra for the LiF:Mg,Cu,Na,Si thermoluminescent materials with various concentrations of the dopants (3-D measurement).

The thermoluminescence (TL) emission spectra from LiF TL materials, called KLT-300 (LiF:Mg,Cu,Na,Si) with various dopant concentrations are measured and analysed. These KLT-300 materials were developed by the Korea Atomic Energy Research Institute (KAERI) to achieve an enhancement of the thermal stability in TL readings. Six types of samples are prepared with different dopant concentrations in the following ranges; Mg (0-0.20 mol%), Cu (0-0.05 mol%), Na and Si (0-0.9 mol%). The spectra measurements are carried out for the six types of samples using a TL emission spectra measurement device. The spectra measurement device consists of a monochromator, photomultiplier tube and temperature control unit to thermally stimulate the samples. The measured data shows the light emission during heating of the sample as a function of temperature and wavelength (three-dimensional TL spectra). The spectra were analysed using a method of deconvolution based on gaussian curve. The wavelength of a main peak of the emission spectra changes depending on the existence of the Cu dopant, while intensity of the spectra rapidly changes with the Cu dopant concentrations. The 385 nm emission is mainly observed in all the spectra from the samples with the Cu dopant, but in those from the samples without the Cu dopant a very weak 401 nm emission is mainly observed. However, any change in the wavelength at a main peak of the TL emission spectra from the sample materials with Na and Si dopants is not observed but that in the intensity at a peak of the spectra is observed.

Combinatorial Chemistry Techniques↗

Search for ionisation density effects in the radiation absorption stage in LiF:Mg,Ti.

Optical absorption (OA) dose-response of LiF:Mg,Ti (TLD-100) is studied as a function of electron energy (ionisation density) and irradiation dose. Contrary to the situation in thermoluminescence dose-response where the supralinearity is strongly energy-dependent, no dependence of the OA dose filling constants on energy is observed. This result is interpreted as indicating a lack of competitive process in the radiation absorption stage. The lack of an energy dependence of the dose filling constant also suggests that the charge carrier migration distances are sufficiently large to smear out the differences in the non-uniform distribution of ionisation events created by the impinging gamma/electron radiation of various energies.

Computer Simulation↗

Properties of the 4.45 eV optical absorption band in LiF:Mg,Ti.

The optical absorption (OA) and thermoluminescence (TL) of dosimetric LiF:Mg,Ti (TLD-100) as well as nominally pure LiF single crystal have been studied as a function of irradiation dose, thermal and optical bleaching in order to investigate the role of the 4.45 eV OA band in low temperature TL. Computerised deconvolution was used to resolve the absorption spectrum into individual gaussian bands and the TL glow curve into glow peaks. Although the 4.45 eV OA band shows thermal decay characteristics similar to the 4.0 eV band its dose filling constant and optical bleaching properties suggest that it cannot be associated with the TL of composite peaks 4 or 5. Its presence in optical grade single crystal LiF further suggests that it is an intrinsic defect or possibly associated with chance impurities other than Mg, Ti.

Computer Simulation↗

Energy responses of the LiF series TL pellets to high-energy photons in the energy range from 1.25 to 21 MV.

The energy responses for the KLT-300(LiF:Mg,Cu,Na,Si, Korea), GR-200(LiF:Mg,Cu,P, China) and MCP-N(LiF:Mg,Cu,P, Poland) thermoluminescence(TL) pellets were studied for a photon radiation with energies from 1.25 MeV(60Co) to 21 MV (Microtron) to verify the usefulness of the calibration for the radiotherapy beams. The International Atomic Energy Agency (IAEA) and the World Health Organization (WHO) have performed thermoluminescence dosimetry (TLD) audits to verify the calibration of the beams by TL powder, but TL pellets were used in this study because the element correction factor (ECF), defined as the factor to correct the variations that all TL dosemeters cannot be manufactured to have exactly the same TL efficiency, for each TL pellet could be accurately derived and be handled conveniently when compared with the powder. Also several works for the energy response of the TLDs were done for the low-energy photon beams up to 60Co, but they will be extended in this experiment to the high photon energies (up to 20 MV), which are widely used in the therapy level of a radiation. The PTW 30006 ionisation chamber was calibrated by the Korea primary standards to establish the air-kerma rates and the TL pellets were irradiated in a specially designed waterproof pellet holder in a water phantom (30 x 30 x 30 cm3) just like the IAEA postal audits programme. This result was compared with that of another type of phantom [10 (W) x 10 (L) x 10 (H) cm3 PMMA Perspex phantom for the 60Co and 6 MV photon, and 10 x 10 x 20 (H) cm3 for the 10 and 21 MV photon] for its convenient use and easy handling and installation in a hospital. The results show that the differences of the responses for the water phantom and PMMA Perspex phantom were negligible, which is contrary to the general conception that a big difference would be expected. For an application of these results to verify the therapy beams, an appropriate energy correction factor should be applied to the energies and phantom types in use.

Computer Simulation↗

Analysis of spectrally resolved thermoluminescence of LiF:Mg,Cu,P detectors by the surface fitting method using algorithm for unrestricted peak positions.

Recently developed surface fitting technique is a natural replacement for the widely used glow curve deconvolution (GCD) technique. Surface fitting can be applied for advanced spectrally resolved thermoluminescence (TL) measurements. It combines both kinetic and emission-band analysis. Owing to greater number of parameters and data points the algorithm is more time-consuming than usual GCD. However, it offers greater reliability in determination of trap parameters. This is especially important for spectrally resolved measurements that are usually performed at low-light level conditions. This paper demonstrates an application of the surface fitting method to the analysis of TL-3D data from LiF:Mg,Cu,P detectors. The spectra were analysed using two different variants of surface fitting--for restricted and unrestricted peak positions.

Algorithms↗

Batch homogeneity of LiF(Mg,Cu,P)-GR200 and LiF(Mg,Cu,P)-MCP-NS TL detectors for use as extremity dosemeters at ENEA personal dosimetry service.

The results of a study of two commercially available LiF(Mg,Cu,P) TL materials, a GR200 detector and a MCP-Ns thin detector, are described in order to use these phosphors for individual monitoring for the extremities. After a dosimetry system has been type tested, the implementation routine is not straightforward. Additional tests and software modification are needed to make the routine system work comply with the type test results. Not often can literature be found on the steps required to implement the results in a routine study. This paper reports the results of the individual calibration of about 15 000 extremity dosemeters, 12 000 containing a GR200 detector and 3000 an MCP-Ns thin detector. It describes the experimental procedure followed in order to assure reproducibility and stability of the results with proper accuracy and reliability. In particular, this is the first time that results on homogeneity of such a large batch of MCP-Ns detectors are reported.

Dose-Response Relationship, Radiation↗

Measurements of the optical density and the thermoluminescent response of LiF:Mg,Ti exposed to high doses of 60Co gamma rays.

The absorption spectra and glow curves of LiF:Mg,Ti exposed to high doses of 60Co gamma rays as well as the optical density curves and thermoluminescent (TL) response as a function of dose were measured. Absorption peaks around 442 nm (2.8 eV), 307 nm (4.0 eV) and 248 nm (5.0 eV) were observed. The optical density is a linear function of dose up to 2500 Gy and then sublinear for the 5.0 eV band, and for the 4.0 eV band it is sublinear with a filling constant of 2.1 x 10(-4) and 6.2 x 10(-4) Gy(-1). The dose response of the 2.8 eV band is linear from 2500 Gy to 10 kGy with a slope of 1.0 x 10(-5) Gy(-1). Once the absorption spectra were obtained, the glow curves and the TL response were obtained. In the dose range, 290-10,000 Gy, the TL response of peaks 5 and 7 was supralinear-sublinear.

Cobalt Radioisotopes↗