PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “MATTRESSES”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35Linked to original sources

Changes to infant sleep practices in Canterbury.

AIM: "Reducing the risk" is a public health primary initiative to minimise the incidence of Sudden Infant Death Syndrome (SIDS) in New Zealand. A number of SIDS risks relate to infant sleep practices. We describe current prevalences of these practices. METHODS: A cohort of Canterbury mothers delivering live infants during May 1997 (n = 411) were mailed a questionnaire in July surveying their infant's sleep practices. Survey results were compared to results derived from the Canterbury control infant component of the 1987-90 New Zealand Cot Death Study (NZCDS) (n = 174). Those mothers using either plastic or rubber mattress covers (n = 63) were issued a subsequent questionnaire pertaining to this mattress-wrapping practice. RESULTS: Completed questionnaires were returned by 274 (66.7%) mothers. Room sharing with mother was usual for 133 (48.5%) infants, no different from the 94 (54.0%) recorded in the NZCDS (chi 2 = 5.6, df = 2, p = 0.06). However, of those infants sharing a room with their mother, 101 (75.9%) slept in their own bed compared to 46 (48.9%) in the NZCDS (chi 2 = 57.0, df = 2, p < 0.01). Only 8 (2.9%) infants were regularly placed prone to sleep, considerably fewer than the 69 (39.7%) reported in the NZCDS (chi 2 = 100.1, df = 1, p < 0.01). Mattress-wrapping with plastic (14.6% vs. 4.0%; chi 2 = 12.8, df = 1, p < 0.01) and rubber (8.4% vs. 3.4%; chi 2 = 4.4, df = 1, p = 0.04) has significantly increased since the NZCDS. Results from the subsequent questionnaire, completed by 42 (66.7%) respondents, indicated that most, 25 (59.5%), wrapped their infant's mattress to stop soiling. Less than half, 18 (42.9%), wrapped the mattress for the "safety of their baby". CONCLUSION: The "non-prone sleeping" campaign has been successful in Canterbury. Most infants are now routinely placed non-prone for sleep. Of those infants sharing a room with their mothers, an increased proportion is sleeping in separate beds. The use of "drycot" under-blankets and sheepskins has diminished. While impermeable mattress-wrapping usage has significantly increased, over three-quarters of Canterbury mothers did not use plastic or rubber mattress-covers on their infant's beds.

Bedding and Linens↗

"Constant force technology" versus low-air-loss therapy in the treatment of pressure ulcers.

"Least costly but most effective" has never been more important to healthcare delivery than in the current healthcare environment of changing reimbursement systems. In wound care, the high costs associated with renting advanced support surfaces may be an area where expenses can be decreased if similar outcomes can be attained by using more affordable mattresses. This article compares the healing rates and eventual outcomes of wounds among two groups of patients randomly assigned to one of two support surfaces. A commonly used low-air-loss mattress was compared with the study mattress, an advanced, non-powered, air and foam surface. Subjects were patients admitted to either of two long-term healthcare settings for the treatment of wounds. The resulting two groups of 10 patients each were evenly matched for average age and percentage of patients who were nutritionally deficient as indicated by albumin or pre-albumin levels. The presence of gastrointestinal tubes and ventilator dependency also was recorded. Consistent wound care protocols were used on both groups, including turning schedules, nutrition, topical medication, and dressings. The study period covered a maximum of 8 weeks; interest was centered on the rate of wound healing and progress toward a goal rather than the length of time to completely close a wound. After 8 weeks, or upon discharge from the study pressure ulcers in the study mattress group closed at an average rate per week of 9.0% +/- 4.8 versus 5.0% +/- 3.7 in the low-air-loss mattress group. This study indicates that the study mattress can provide benefits to the wound healing process similar to or better than low-air-loss mattresses at a substantially reduced cost.

Adult↗

Comparison of contact pressures measured at the sacrum of young and elderly subjects.

Contact (interface) pressure measurements were made between the sacrum of groups of young and elderly subjects lying upon two special mattresses used to prevent pressure sores. One mattress was an alternating air pressure mattress, the other a foam mattress. Contact pressures were measured using a hydraulic sensor taped directly to the skin over the sacrum. All mean pressures and 'pressure impulses' (total applied pressure per standard time period) appeared higher when measured among the elderly subjects. Compared with the pressures measured from young subjects, the maximum contact pressures were significantly higher (p less than 0.05) on both mattresses, with the pressure impulse higher while lying upon the foam mattress (p less than 0.05).

Adult↗

Rotator cuff repair: an ex vivo analysis of suture anchor repair techniques on initial load to failure.

PURPOSE: To determine the best combination of anchors and suture techniques for repairing torn rotator cuff tendons. TYPE OF STUDY: Ex vivo biomechanical investigation. METHODS: Sixty fresh-frozen sheep infraspinatus tendons were repaired using 6 different repair techniques: transosseous sutures with 2 sutures and mattress stitches; 2 suture anchors with 1 suture per anchor using either simple stitches, mattress stitches, or modified Kessler stitches; 2 suture anchors with 2 sutures per anchor using simple stitches; or 5 suture anchors with 1 suture per anchor and a mattress stitch pattern. RESULTS: No difference was identified between transosseous sutures (mean +/- SD, 147 +/- 68 N) and suture anchors (140 +/- 36 N) when 2 mattress stitches were used. The weakest construct with suture anchors was when the tendon was grasped with 2 suture anchors with 1 suture per anchor and a simple stitch pattern (72 +/- 25 N). Repair strength increased 2-fold with 2 suture anchors single loaded and a mattress stitch configuration (140 +/- 36 N; P = .026), 3-fold with 2 suture anchors single loaded and a modified Kessler stitch pattern (204 +/- 32 N; P < .001), and 3-fold with 2 suture anchors double loaded and a simple stitch suture pattern (212 +/- 39 N; P < .001). The highest tensile load was observed with 5 suture anchors in a double-row configuration, single loaded, that grasped the tendon with mattress stitches (336 +/- 59 N; P < .001). CONCLUSIONS: This study shows that in an ovine model, initial rotator cuff repair strength can be enhanced by increasing the number of suture anchors used in the repair and by using anchors that are double loaded with suture and suture configurations that pass more frequently through the tendon. CLINICAL RELEVANCE: The clinical relevance of this ex vivo investigation is that the initial load to failure of a rotator cuff repair may be increased by increasing the number of suture anchors, the number of sutures per anchor, or using suture patterns that grab more adjacent tendon fibers.

Animals↗

The effect of various combinations of turning and pressure reducing devices on the incidence of pressure ulcers.

BACKGROUND: Turning is considered to be an effective way of preventing pressure ulcers, however almost no research has been undertaken on this method. AIM: The aim of the study was to investigate the effect of four different preventative regimes involving either frequent turning (2, 3 hourly) or the use of a pressure-reducing mattress in combination with less frequent turning (4, 6 hourly). SUBJECTS: 838 geriatric nursing home patients participated in the study. METHODS: During 28 days, four different turning schemes were used: turning every 2 h on a standard institutional (SI) mattress (n = 65), turning every 3 h on a SI mattress (n = 65), turning every 4 h on a viscoelastic foam (VE) mattress (n = 67), and turning every 6h on a VE mattress (n = 65). The remaining patients (n = 576) received standard preventive care. MAIN RESULTS: The incidence of non-blanchable erythema (34.8-38.1%) was not different between the groups. The incidence of grade II and higher pressure ulcers in the 4h interval group was 3.0%, compared with incidence figures in the other groups varying between 14.3% and 24.1%. CONCLUSIONS: Turning every 4 h on a VE mattress resulted in a significant reduction in the number of pressure ulcer lesions and makes turning a feasible preventive method in terms of effort and cost.

Aged↗

Childhood cat allergen exposure in three European countries: The AIRALLERG study.

INTRODUCTION: Cat allergen is a major cause of morbidity among sensitised asthma patients, but little is known about distribution of cat allergen exposure and its determinants in homes. METHODS: We measured cat allergen and potential determinants of cat allergen levels in more than 1000 homes. House dust was collected from children's mattresses and living room floors in approximately 360 homes in The Netherlands, Sweden and Germany and analysed for Fel d 1 in one central laboratory. Exposure was expressed both in concentration (ng/g) and in loads (ng/m2). RESULTS: Levels on mattresses were similar in Sweden and Germany but higher on Dutch mattresses. Dutch floors had higher concentrations than Swedish floors, which had higher concentrations than German floors. The differences in load were less clear. Cat allergen on mattress and floor were moderately to highly correlated. The most important variable quantifying cat allergen variation was the presence of a cat. Floor cover type and last time that floor was vacuumed were important in all three countries. The ratio of cat allergen loads between mattresses from homes with and without cats was higher for Sweden and Germany than for The Netherlands. This is likely related to higher prevalence of cat ownership in The Netherlands which leads to more contamination of homes in which cats were never held. Dust samples from 27-35% of mattresses from homes without cats contained more than 1000 ng/g cat allergen. CONCLUSION: With the exception of cat ownership and floor cover, questionnaire data on housing characteristics did not accurately predict cat allergen in the home.

Air Pollution, Indoor↗

Manchester Asthma and Allergy Study: low-allergen environment can be achieved and maintained during pregnancy and in early life.

BACKGROUND: Early exposure to dust mite allergens may be critical for primary sensitization. Reducing exposure may offer a realistic chance for primary prevention of sensitization and asthma, but it is essential to implement measures that can achieve and maintain the low-allergen environment. OBJECTIVE: Our purpose was to assess the effectiveness of mite allergen avoidance measures in achieving and maintaining a low-allergen environment during pregnancy and in the first year of life. METHODS: The Manchester Asthma and Allergy Study is a prospective, prenatally randomized study that follows the development of asthma and atopy in a cohort of infants at high risk (both parents atopic) who are randomly allocated to full mite allergen avoidance or to a normal regimen. Avoidance measures comprise (1) mite-proof covers (mattress, pillow, and quilt) for parental bed, (2) high-filtration vacuum cleaner, (3) vinyl flooring in infant's bedroom, (4) new crib and portable crib mattresses encased in mite-proof material, (5) benzyl benzoate (Acarosan) applied on carpets and soft furniture, (6) bed linens washed in hot water weekly, and (7) washable soft toys. Dust samples from the parental bed, bedroom floor, living room floor, infant's mattress, and nursery floor were collected between the 10th and 14th weeks of pregnancy, immediately after birth, and then at age 6 months and 1 year, and Der p 1 levels were determined by mAb-based ELISA. RESULTS: Recovered Der p 1 from maternal mattress was reduced by 97. 25% (95% confidence interval [CI] 95.25%-98.41%) during the second and third trimesters of pregnancy, with the effect persisting for 6 months (98% reduction, 95% CI 97.25%-99.1%) and 12 months (97.6% reduction, 95% CI 95.7%-98.6%) after the birth (active vs control, P <.000001). Total Der p 1 from bedroom floor in the active group was reduced by 53.7% (95% CI 25.7%-71.2%) in samples collected within 4 weeks of the child's birth, with the percentage reduction being 62. 8% (95% CI 39.3%-77.2%) at 6 months and 26.5% (95% CI -24% to 57.1%) at 1 year (active compared vs control, P <.007). Der p 1 levels in crib mattress and nursery floor in the active group were extremely low (crib mattresses geometric mean [95% CI] 2.3 ng [1.6-3.4] at birth, 6.8 ng [4.5-10] at age 6 months, and 15.6 ng [9.8-24.8] at age 1 year [active vs control, P =.001]; nursery 1 ng [0.9-1.1] at birth, 1.7 ng [1.2-2.5] at age 6 months, and 2 ng [1.3-3.5] at age 1 year [active vs control, P <.00001]). The total amount of allergen recovered at age 1 year was 29-fold (95% CI 15.1- to 56.7-fold) higher in the control group than in the active group. CONCLUSIONS: The avoidance measures used in this study achieved and maintained a low mite allergen environment during pregnancy and in the first year of life in homes of infants at risk of atopy.

Allergens↗

Load to failure of common meniscal repair techniques: effects of suture technique and suture material.

Success of meniscal repair with early or immediate motion depends on the ability of the suture fixation to withstand the loads applied. Vertical and horizontal mattress suture techniques were tested using 2-0 Ethibond, and 0-PDS and 1-PDS sutures (Ethicon, Somerville, NJ). Mulberry knot technique was tested with 0-PDS and 1-PDS sutures. Twenty menisci (60 sutures) were tested for each suture material. Sutures were placed 3 to 4 mm from the peripheral edge of the meniscus with double barreled cannulas for vertical and horizontal mattress techniques or a spinal needle for the mulberry knot technique, reproducing clinical techniques of meniscal repair. Mechanical testing of suture fixation was performed to failure at a rate of 10 mm/min on a MTS material testing system (MTS Systems Corp, Minneapolis, MN). Suture pullouts were reported as the load displacement to failure from the inner fragment only, because clinical failure would ensue should a suture pull through the inner fragment of a tear. Vertical mattress technique with 1-PDS suture had significantly greater load to failure than any other combination (P < .05). Analysis of variance showed that the vertical mattress technique had statistically superior pullout strength (P < .0001) compared with the horizontal mattress and mulberry knot techniques, which were statistically similar. There were significant differences (P < .0001) between suture types, with 1-PDS proving best compared with 0-PDS, which was stronger than 2-0 Ethibond. Selection of suture material had the greatest impact on vertical mattress load to failure and was not important to the strength of the other techniques.

Analysis of Variance↗

Household characteristics and mite allergen levels in Manchester,UK.

BACKGROUND: Mite allergen levels vary enormously between different homes in the same geographical area. No large scale studies of mite levels in Manchester homes has been conducted to identify factors associated with higher levels. OBJECTIVES: To quantify exposure to mite allergens and to identify characteristics associated with higher Der p 1 levels in a large sample of homes in Manchester, UK. METHODS: Der p 1 was measured in dust from the living room floor, sofa, bedroom floor and mattress in 564 homes. Data on household characteristics were collected by administering a questionnaire. Univariate and multivariate analyses were performed to identify household characteristics associated with higher mite allergen levels. RESULTS: Der p 1 levels were highest in the mattress (GM 1.19 microg/g, 95% CI 0.98-1.45, P < 0.001). Two-thirds of homes contained Der p 1 levels > 2 microg/g in at least one dust reservoir, and 40.3% contained Der p 1 greater than 10 microg/g. There was a large range in Der p 1 levels between homes (> 10(3)-fold). Damp and condensation were common findings in homes. In the multivariate analyses, factors associated with higher Der p 1 levels in more than one dust reservoir were older homes, older living room carpets, damp, condensation and mixed glazing. Older mattresses were associated with higher mite allergen levels in the mattress where the age of the mattress was recorded. Twenty-four homes contained no detectable mite allergen, six of which reported damp. CONCLUSIONS: Mite allergen levels are high enough in two of every three homes to be associated with an increase in the risk of sensitization to mite. Factors such as older homes, carpets and mattresses, damp and condensation are associated with higher mite allergen. However, mite allergen levels are occasionally unpredictably very low in homes with risk factors for high levels.

Allergens↗

Influence of lateral motion transfer on sleep.

This study examined the effects of motion of an artificial bed partner on the sleep of a real subject on the same mattress. A 240-lb eight-sided cylindrical roller served as the artificial bed partner. The roller was placed on one side of a king-size mattress and a normal adult slept on the other half. On experimental nights, the roller intermittently rocked back and forth for brief periods of time which in aggregate represented approximately 13% of total sleep time. On control nights, the roller was stationary. After an adaptation night in the laboratory, subjects spent two more nights in the sleep laboratory. The order of Roller On and Roller Off nights was random. 24 subjects were randomly assigned to sleep on the three surfaces. The three mattresses used in the study had different construction designs and in turn variable properties of motion transfer. Sleep variables were measured objectively by nocturnal polysomnography and subjectively by a postsleep questionnaire. Analysis of the data indicated that motion transferred laterally across a mattress was associated with a significant increase in Stage 1 sleep, and a significant decrease in Stage 3/4 sleep. Over-all, sleep efficiency, number of awakenings, and wakefulness after sleep onset did not show significant changes from control to experimental nights. The amount of change in sleep architecture, however, was more notable on the mattresses which transferred more motion. An implication of these findings is that motion transferred across the surface of a mattress, by lightening the depth of the sleep and thereby decreasing the auditory arousal threshold, can increase the potential for sleep disruption from environmental stimuli such as noise.

Adult↗

Systematic reviews of wound care management: (5) beds; (6) compression; (7) laser therapy, therapeutic ultrasound, electrotherapy and electromagnetic therapy.

BACKGROUND: Chronic wounds such as leg ulcers, diabetic foot ulcers and pressure sores are common in both acute and community healthcare settings. The prevention and treatment of these wounds involves many strategies: pressure-relieving beds, mattresses and cushions are universally used as measures for the prevention and treatment of pressure sores; compression therapy in a variety of forms is widely used for venous leg ulcer prevention and treatment; and a whole range of therapies involving laser, ultrasound and electricity is also applied to chronic wounds. This report covers the final three reviews from a series of seven. AIMS: To assess the clinical effectiveness and cost- effectiveness of: (1) pressure-relieving beds, mattresses and cushions for pressure sore prevention and treatment; (2) compression therapy for the prevention and treatment of leg ulcers; (3) low-level laser therapy, therapeutic ultrasound, electrotherapy and electromagnetic therapy for the treatment of chronic wounds. METHODS - DATA SOURCES: Nineteen electronic databases, including MEDLINE, CINAHL, EMBASE and the Cochrane Controlled Trials Register (CENTRAL), were searched. Relevant journals, conference proceedings and bibliographies of retrieved papers were handsearched. An expert panel was also consulted. METHODS - STUDY SELECTION: Randomised controlled trials (RCTs) which evaluated these interventions were eligible for inclusion in this review if they used objective measures of outcome such as wound incidence or healing rates. RESULTS - BEDS, MATTRESSES AND CUSHIONS FOR PRESSURE SORE PREVENTION AND TREATMENT: A total of 45 RCTs were identified, of which 40 compared different mattresses, mattress overlays and beds. Only two trials evaluated cushions, one evaluated the use of sheepskins, and two looked at turning beds/kinetic therapy. RESULTS - COMPRESSION FOR LEG ULCERS: A total of 24 trials reporting 26 comparisons were included (two of prevention and 24 of treatment strategies). RESULTS - LOW-LEVEL LASER THERAPY, THERAPEUTIC ULTRASOUND, ELECTROTHERAPY AND ELECTROMAGNETIC THERAPY: Four RCTs of laser (for venous leg ulcers), 10 of therapeutic ultrasound (for pressure sores and venous leg ulcers), 12 of electrotherapy (for ischaemic and diabetic ulcers, and chronic wounds generally) and five of electromagnetic therapy (for venous leg ulcers and pressure sores) were included. Studies were generally small, and of poor methodological quality. CONCLUSIONS (1) Foam alternatives to the standard hospital foam mattress can reduce the incidence of pressure sores in people at risk, as can pressure-relieving overlays on the operating table. One study suggests that air-fluidised therapy may increase pressure sore healing rates. (2) Compression is more effective in healing venous leg ulcers than is no compression, and multi-layered high compression is more effective than single-layer compression. High-compression hosiery was more effective than moderate compression in preventing ulcer recurrence. (3) There is generally insufficient reliable evidence to draw conclusions about the contribution of laser therapy, therapeutic ultrasound, electrotherapy and electromagnetic therapy to chronic wound healing.

Bandages↗

Vacuum cleaning does not sufficiently reduce mite allergens from beddings.

INTRODUCTION: Conflicting results exist with regard to the efficacy of vacuum cleaners on the removal of mite allergens from bedding. OBJECTIVES: The authors prospectively compared a short term efficacy of two types of regular vacuum cleaners (National-N and Hoover-H) with a specialized cleaner (Vorwerk-V) in the removal of mite allergens from mattresses. MATERIAL AND METHOD: Thirty-five dormitory beds with high mite allergen concentrations at the baseline period (month 0) were selected. They were matched into three groups according to group I mite allergen concentrations (N 11 beds, H 12 beds, V 12 beds). Vacuuming was performed on months 1 and 4 by the assigned vacuum cleaner in each group. Immediately after, mattresses were vacuumed by a reference cleaner (another National vacuum cleaner) at both months. Vacuuming was performed over the entire bed for 2 minutes/square meter. Group I mite allergens (sums of Der p 1 and Der f 1) were measured; concentrations and total mite allergens removed by the tested cleaners as well as by the reference cleaner, at various time points, were compared. RESULTS: Ability to remove mite allergens by vacuum cleaners depends on weight of dust removed and also on mite concentrations in the dust samples. Despite the fact that H and V appeared to remove higher mite allergens than N, such differences were not statistically significant (p > 0.05), both at month 1, and 4. Surprisingly, mattress mite concentrations removed by both high capacity cleaner groups (V & H) increased at month 4, whereas, it remained unchanged in the third group (N). This increase led to a concomitant increase in total allergen removed by V and H. Nevertheless, remaining total allergens in the mattresses in V and H, as judged from the amount of allergens obtained by the reference cleaner, increased at month 1 and 4 compared to baseline values (p < 0.05), whereas, no change was observed in N. CONCLUSION: Although high capacity vacuum cleaners removed a large amount of mite allergens from mattresses, they did not sufficiently reduce mattress mite allergen burden as determined by the reference cleaner during this short term study.

Allergens↗

A lumbar body support (KBS 2000) alters lumbar muscle recruitment patterns in patients with acute-upon-chronic lower back pain.

OBJECTIVE: To determine the effects of a locally designed lumbar body support (LBS) on integrated electromyographic (IEMG) activity of the lumbar erector spinae muscles, on heart rate and on ratings of discomfort in patients with low back pain. DESIGN: Non-randomised controlled trial. SETTING: Patients referred from general practitioners and back pain rehabilitation programmes in Cape Town. PATIENTS AND OTHER PARTICIPANTS: Ten patients with low back pain of diverse causes. Values were compared with those in 10 control subjects without low back pain. INTERVENTION: Patients and controls lay supine on (in random order) either a flat conventional mattress or a LBS placed on top of the flat mattress, for a 30-minute period (acute exposure), and every night for 2 weeks (chronic exposure). MAIN OUTCOME MEASURES: IEMG activity of the lumbar erector spinae muscles, heart rate, and perception of comfort. RESULTS: IEMG activity of the lumbar erector spinae muscles did not differ between controls and patients when lying on the LBS on top of the CM after either acute or chronic exposure. However, it was significantly greater (P < 0.05) in patients than in controls when lying on the flat mattress. Subjective ratings of discomfort and heart rates mirrored these changes and were higher in patients only when lying on the flat mattress (P < 0.05). Patients with low back pain also reported that sleeping overnight on the LBS on top of their own mattress significantly reduced discomfort ratings. CONCLUSIONS: When lying on a mattress with a flat surface, patients with chronic low back pain have higher IEMG activity of the erector spinae muscles, higher heart rates and higher subjective ratings of discomfort than do control subjects. These differences disappear when both groups use a specially designed lumbar body support placed on top of the flat surface. These preliminary studies suggest that a lumbar body support should be evaluated in the chronic management of low back pain.

Adult↗

Allergen content in dust from homes and schools in northern Norway in relation to sensitization and allergy symptoms in schoolchildren.

BACKGROUND: Previous studies have shown a high prevalence of atopic diseases among school children in the community of Sør-Varanger. Moreover, animal dander followed by pollen and house dust mite, were the most common allergens in skin prick tests. OBJECTIVE: To assess the allergen content in homes (living-rooms and mattresses) and classrooms of children living in an arctic area at 70 degrees. The presence of allergens in homes and schools and their relationship to atopy was of particular interest. METHODS: Dust samples from 38 homes and seven schools in northern Norway were collected by vacuum cleaning. The presence of allergens of dog, birch, timothy, Cladosporium herbarum, codfish and hen egg-white was investigated by radio-allergosorbent test (RAST) inhibition and the presence of major allergens of cat Felis domesticus (Fel d I) and house dust mites (HDM) Dermatophagoides pteronyssinus (Der p I) and Dermatophagoides farinae (Der f I) by enzyme-linked immunosorbent assay (ELISA). RESULTS: Mattresses contained significantly more dust per unit area than living-rooms and classrooms. No statistically significant differences in allergen content for dog, birch, timothy. Cladosporium, codfish and hen egg-white were seen between HDM-sensitized and non-atopic children. Most dust samples contained dog allergens with the highest allergenic activity found in living-rooms of those keeping dogs. An increased level of Fel d I was detected in only one of 38 samples from living-rooms (this family kept a cat) and in 25 of 38 samples from mattresses with ranges from 24 to 84 ng/m2. The highest concentrations were found in mattresses of children keeping cats. Increased levels (> or = 25 ng/m2) of Der p I were found only in homes and virtually only in mattresses of HDM-sensitized children. An increased level of Der f I was found in only one case, i.e. in the mattress of an HDM-sensitized child where additionally Der p I and HDMs were demonstrated microscopically. When relating Der p I to HDM-sensitization an odds ratio of more than 16 (95% CI: 1.6-394.3) was found. All extracts from living-rooms included codfish allergens. Low RAST inhibition values were detected for hen egg-white. Cladosporium, birch and timothy pollen in most samples. Furthermore, the study demonstrated that dust from schools was relatively free of allergens. CONCLUSION: Previous findings indicating that the main allergen exposure problem in this geographical area is that of pet allergens were confirmed.

Allergens↗

Triple-loaded single-anchor stitch configurations: an analysis of cyclically loaded suture-tendon interface security.

PURPOSE: This study evaluated the strength and suture-tendon interface security of different suture configurations from triple-suture-loaded anchors. METHODS: A juvenile bovine infraspinatus tendon was detached and repaired by use of 4 different suture combinations from 2 suture anchors: 3 simple sutures in each anchor (ThreeVo anchor; Linvatec, Largo, FL); 2 peripheral simple stitches and 1 central horizontal mattress suture passed deeper into the tendon, creating a larger footprint (bigfoot-print anchor); 2 peripheral simple stitches with 1 central horizontal mattress stitch passed through the same holes as the simple sutures (stitch-of-Burns); and 2 simple stitches (TwoVo anchor; Linvatec). The constructs were cyclically loaded between 10 N and 180 N for 3,500 cycles and then destructively tested. The number of cycles required to create a 5-mm gap and a 10-mm gap and the ultimate load to failure and failure mode were recorded. RESULTS: The ThreeVo anchor was strongest and most resistant to cyclic loading (P < .01). The TwoVo anchor was least resistant to cyclic loading. The stitch-of-Burns anchor was more resistant to cyclic loading than both the bigfoot-print anchor and the TwoVo anchor (P < .03). The ThreeVo, stitch-of-Burns, and TwoVo anchors were stronger than the bigfoot-print anchor (P < .05). CONCLUSIONS: Three simple sutures in an anchor hold better than two simple sutures. Three simple sutures provide superior suture-tendon security than combinations of one mattress and two simple stitches subjected to cyclic loading. A central mattress stitch placed more medially than two peripheral simple stitches (bigfoot-print anchor) configured to enlarge the tendon-suture footprint was not as resistant to cyclic loading or destructive testing as three simple stitches (ThreeVo anchor). CLINICAL RELEVANCE: Placing a central mattress stitch more medially than 2 peripheral simple stitches to enlarge the tendon-suture footprint was not as resistant to cyclic loading or destructive testing as 3 simple stitches.

Animals↗

Levels and determinants of beta(1-->3)-glucans and fungal extracellular polysaccharides in house dust of (pre-)school children in three European countries.

BACKGROUND: Mold growth is believed to be one causative factor underlying the association between dampness in buildings and increased respiratory morbidity. Measurements of beta(1-->3)-glucans and fungal extracellular polysaccharides (EPS) are used as markers of mold exposure in field studies. Little is known about their levels and determinants in homes. OBJECTIVE: To study levels and determinants of beta(1-->3)-glucan and EPS levels in mattress and living room floor dust in three European countries. METHODS: Mattress and living room floor dust was collected in the homes of 1065 German, Dutch, and Swedish (pre-)school children. All samples were analyzed for beta(1-->3)-glucans and EPS in one central laboratory. Determinants were assessed by questionnaire. RESULTS: Amounts of dust, EPS and beta(1-->3)-glucan levels differed between countries. Amounts of dust, beta(1-->3)-glucan and EPS levels for mattresses were only weakly correlated with those for living room floors. Floor dust beta(1-->3)-glucan loads, EPS loads and EPS concentrations were strongly correlated with the amount of dust sampled, which is largely determined by the type of floor that was sampled (carpeted floors had 5-20 higher amounts of dust). None of the other determinants was consistently and statistically significantly associated with amounts of dust, beta(1-->3)-glucan and EPS concentrations on floors and mattresses. CONCLUSION: Mattress dust and floor dust are two different measures of exposure to the investigated mold components. Living room floor beta(1-->3)-glucan and EPS loads and EPS concentrations are largely determined by the type of floor sampled. Differences between countries can only partly be explained by the determinants studied.

Air Pollution, Indoor↗

The influence of bed firmness on sleep quality.

We studied the relationship between sleep quality and bed surface firmness. Nine men were investigated, sleeping in their homes for at least 5 consecutive nights on a soft and a more firm mattress using a sensor pad placed under the mattress and a solid-state recording device. The subjective feeling of sleep quality did not always agree with the recorded sleep data. The difference was most marked when changing from the subject's own to one of the test mattresses. For the same subject the results were reproducible between nights provided there were no external disturbing factors. Four of the 9 subjects slept significantly better on the softer of the two mattresses and 2 on the hard mattress. The difference in sleep quality observed among the subjects tested makes it necessary to relate the results to the same person rather than considering a whole group as an entity. The adaptation period for a new sleep surface extended to many days.

Adaptation, Physiological↗

The Melbourne House Dust Mite Study: long-term efficacy of house dust mite reduction strategies.

BACKGROUND: Asthma severity among mite-sensitized individuals appears to be related to the degree of mite allergen exposure. OBJECTIVES: The objective of this study was to assess the long-term effectiveness of mite avoidance measures in the homes of asthmatic children in Melbourne, Australia. METHODS: The concentration of house dust mite allergen (Der p 1) was measured on the child's mattress surfaces and bedroom floors in 85 homes on 10 occasions over a 16-month period. After the first three visits, all mattresses were covered with a semipermeable encasement, and carpeted bedroom floors were randomly allocated to regular applications of a placebo or an "anti-mite" shampoo. RESULTS: The concentration of Der p 1 recovered was initially high in the carpeted bedrooms (n = 66) (41.1, 95% confidence interval, 30.7 to 55.0 microg Der p 1 per gm) and mattresses (n = 85) (39.6, 27.2 to 57.7). During the initial observation period the concentration of mite allergen fell in the treatment, placebo, and parental control groups. During the seven treatment periods, no differences were seen between the Der p 1 concentrations in the groups using the "anti-mite" shampoo, placebo shampoo, or the parental control group (e.g., at visit 4; 12.6, 8.2 to 19.5; 14.8, 8.6 to 25.1; and 12.0, 8.1 to 17.7 microg/gm, respectively). In contrast, the concentration of Der p 1 in samples from uncarpeted floors and mattress encasements was low (4.1, 2.1 to 8.0 microg/gm and 4.2, 2.6 to 6.5 microg/gm, respectively) and insufficient dust for analysis was frequently obtained from these sites. CONCLUSIONS: There was no additional benefit from the use of an "anti-mite" shampoo. The absence of carpets and the use of mattress encasements was a useful long-term strategy for mite allergen avoidance.

Animals↗