PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Optics and Refraction”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35Linked to original sources

Determination of thickness, refractive index, and thickness irregularity for semiconductor thin films from transmission spectra.

A simplified theoretical model has been proposed to predict optical parameters such as thickness, thickness irregularity, refractive index, and extinction coefficient from transmission spectra. The proposed formula has been solved for thickness and thickness irregularity in the transparent region, and then the refractive index is calculated for the entire spectral region by use of the interference fringes order. The extinction coefficient is then calculated with the exact formula in the transparent region, and an appropriate model for the refractive index is used to solve for the extinction coefficient in the absorption region (where the interference fringes disappear). The proposed model is tested with the theoretical predicted data as well as experimental data. The calculation shows that the approximations used for solving a multiparameter nonlinear equation result in no significant errors.

Journal Article↗

Cerebral visual impairment in preterm infants with periventricular leukomalacia.

Neonatal brain lesions are the main cause of cerebral visual impairment in infancy, i.e., of a visual deficit caused by damage to posterior visual pathways. Visual outcome of preterm infants with periventricular leukomalacia (PVL) was investigated in 14 subjects affected by severe cystic PVL, another 34 with moderate PVL (prolonged periventricular echodensities), and 18 control preterm infants. All cases with significant ocular abnormalities (such as retinopathy of prematurity state III or upwards, optic nerve atrophy, or major refraction problems) were excluded. Visual acuity, visual field, eye alignment, fixation and following, optokinetic nystagmus, and visual threat were tested at 1 year of corrected age. A high incidence of cerebral visual impairment, consisting mainly of low visual acuity, severe oculomotor disorders, and reduced visual field, was found in infants with severe PVL. Visual defects were less frequent and less severe in the moderate PVL group, and very rare in the control group. The results of neuroimaging, and especially of magnetic resonance imaging, correlated with the visual outcome and indicate lesions at the level of optic radiations as the main anatomic substrate of the visual impairment. All infants with PVL need a visual follow-up, from the first months of life, the results of which are important both for visual and motor rehabilitation of these cases and for their daily care.

Female↗

Paraxial ray tracing through noncoaxial astigmatic optical systems, and a 5 x 5 augmented system matrix.

The matrix method of tracing a paraxial ray through a coaxial optical system that contains spherical refracting elements requires a 2 x 2 system matrix. This paper shows that a suitable 5 x 5 system matrix enables one to apply the same method in the general case of systems that may be noncoaxial and that may contain astigmatic elements. The systems may contain prisms and decentered astigmatic lenses, for example.

Astigmatism↗

Effect of expanding the treatment zone of the Nidek EC-5000 laser on laser in situ keratomileusis outcomes.

PURPOSE: To evaluate the effect of expanding the treatment zone of the Nidek EC-5000 laser on postoperative visual acuity as well as night glare and halos after laser in situ keratomileusis (LASIK) using 4 ablation zone diameters. SETTING: Division of Ophthalmology, Evanston Northwestern Healthcare and Northwestern University Medical School, Glenview, Illinois, USA. METHODS: This prospective study comprised 301 eyes of 154 consecutive patients who had LASIK in 1 or both eyes using the Nidek EC-5000 laser by 1 surgeon with experience in keratomileusis and excimer laser refractive surgery. A 6.5 mm optical zone was used with a transition zone 1.0 mm larger than the pupil under scotopic conditions (7.5, 8.0, 8.5, or 9.0 mm). Targeted correction was calculated according to a customized clinical nomogram. All patients were queried about glare and halos preoperatively and 3 months postoperatively using a questionnaire assigning numeric values to the degree of perceived visual disturbance (0 = no glare or halos, 1 = minimal, 2 = moderate, 3 = severe). RESULTS: The baseline uncorrected visual acuity (UCVA) was 20/200 or worse in 293 eyes. The baseline best spectacle-corrected visual acuity was 20/20 or better. The mean preoperative refractive sphere was -6.33 diopters (D) +/- 2.80 (SD) (range -1.00 to -16.25 D) and the mean preoperative refractive cylinder, 0.86 +/- 0.83 D (range 0 to +3.25 D). Three months postoperatively, 78% of eyes had a UCVA of 20/20 and 99%, of 20/40 or better. Preoperatively, 94 eyes (31%) had glare and halos. At 3 months, glare, halos, or both were present in 19 eyes of 11 patients (6.3%) (P<.0001); in 14 eyes, patients reported less severe glare and halos postoperatively than preoperatively. CONCLUSIONS: The use of a peripheral transition zone 1.0 mm larger than the pupil under scotopic conditions resulted in a low incidence of glare and halos postoperatively and did not adversely affect visual acuity. There was no increase in postoperative complications including corneal ectasia.

Adult↗

[Cataract surgery in nanophthalmic eyes with an axial length of less than 20.5 mm].

BACKGROUND: Aim of this study was to analyze the results of cataract surgery in nanophthalmic eyes with axial length of less than 20.5 mm. PATIENTS AND METHODS: From 1991 to 1996 extracapsular cataract extraction with posterior chamber lens implantation was performed in 20 eyes of 19 patients (mean age 70.2 +/- 12.7 years, 4 male, 16 female) with axial length of less than 20.5 mm. Mean preoperative visual acuity was 0.16 +/- 0.15, refractive error +5.1 +/- 3.8 dpt and intraocular pressure 18.7 +/- 10.3 mm Hg. The mean follow-up was 24.4 months. Patient data were collected prospectively with standardized "Erlanger Augenblätter" and the computer-aided automatized operation record system "OPERA". These data together with the biometrical data were analized in a retrolective manner. RESULTS: Preoperatively 6 of 20 eyes had angle closure situation, 7 of 20 eyes had undergone intraocular surgery previously (5 x iridotomy, 1 x surgical iridectomy, 1 x filtration procedure). Pseudoexfoliation syndrome was present in 3 eyes. The posterior chamber lens (mean refractive power 31.7 +/- 3.0 dpt, optic diameter 6.5 and 7.0 mm) was positioned 18 x intracapsular, 2 x into the sulcus and 1 x by scleral fixation due to capsular rupture without vitreous loss. In 16 of 20 eyes iris surgery was performed additionally, in one eye an anterior sclerotomy was necessary. Intraoperatively "vis a tergo" occurred in 10 eyes and anterior chamber hemorrhage in one eye. Visual acuity improved in 16 of 20 eyes. The mean visual acuity was 0.3 +/- 0.2. At the end of follow-up 13 eyes had an improvement of visual acuity. Mean intraocular pressure was 16.5 +/- 3.3 mm Hg, refractive error was +0.47 +/- 2.9 dpt and differed by -0.49 +/- 1.8 dpt from the preoperatively calculated refraction. Postoperatively angle closure glaucoma developed in one eye, a ciliopseudophakic angle closure glaucoma and recurrent iris bombata in one eye. Reoperations included cyclokryokoagulation in two eyes, pars plana vitrectomy in one eye and repeated Nd-YAG iridotomies in one eye. CONCLUSION: Regarding the special anatomic situation, the surgical procedure has to be planned individually, including the determination of sclera thickness, corneal diameter and lens volume/eye volume ratio.

Aged↗

Poly(dimethylsiloxane) hollow Abbe prism with microlenses for detection based on absorption and refractive index shift.

In this paper we report on an optical detection method that utilizes two physical effects for signal transduction, namely absorption and shift of refractive index. The device consists of a hollow prism and was fabricated by means of soft-lithography. It exhibits a high degree of monolithic integration. In order to keep down the amount of external equipment that is necessary to run the device, we were able to integrate several functions, such as focussing of light and alignment of optical fibres. Since all components are fabricated in the same material and in the same process, compatibility with other microfluidic devices or components can be achieved easily. The functional efficiency and the performance of the detector were tested by investigating solutions containing fluorescein, with concentrations between 5 and 1000 microM. The results clearly show the two regions in which the two physical effects are effective.

Journal Article↗

Preliminary results and complications of radial keratotomy.

We preformed radial keratotomy for myopia on 126 eyes of 102 patients. We observed as much as 12 diopters of early postoperative refractive corneal flattening, but a mean of only 5.16 diopters of refractive change can be expected after one year. Among the many complications observed were corneal scarring, an endothelial cell loss of 220 cells/mm2 (6.9%), epithelial ingrowth in 18 eyes (14%), corneal vascularization in one of 126 patients (1%), pain, Cogan's corneal dystrophy, overcorrections in 18 patients (14%), anisometropia, perforations of the anterior chamber in 12 patients (10%), iatrogenic astigmatism, corticosteroid glaucoma, night glare in 99 patients (79%), and fluctuating vision in 95 (75%). We studied the following factors to determine if they had predictive value: the patient's age, diopters of myopia, corneal diameter, corneal thickness, anterior chamber depth, axial length, scleral rigidity, keratometric readings, and the size of the optical zone. We found that no preoperative factor can be used to estimate precisely the postoperative result. The only consistent variable was the size of the optical zone. The smaller the optical zone, the larger the refractive change. This lack of predictability is the most serious shortcoming of radial keratotomy.

Adolescent↗

Simulation of specimen-induced aberrations for objects with spherical and cylindrical symmetry.

Wavefront aberrations caused by the refractive index structure of the specimen are known to compromise signal intensity and three-dimensional resolution in confocal and multiphoton microscopy. However, adaptive optics can measure and correct specimen-induced aberrations. For the design of an adaptive optics system, information on the type and amount of the aberration is required. We have previously described an interferometric set-up capable of measuring specimen-induced aberrations and a method for the extraction of the Zernike mode content. In this paper we have modelled specimen-induced aberrations caused by spherical and cylindrical objects using a ray tracing method. The Zernike mode content of the wavefronts was then extracted from the simulated wavefronts and compared with experimental results. Aberrations for a simple model of an oocyte cell consisting of two spherical regions and for a model of a well-characterized optical fibre are calculated. This simple model gave Zernike mode data that are in good agreement with experimental results.

Animals↗

Investigation of dual-channel fiber-optic surface plasmon resonance sensing for biological applications.

A dual-channel fiber-optic sensor based on surface plasmon resonance (SPR) for self-referencing refractive-index measurements has been proposed. Most applications of fiber-optic SPR sensors are designed to measure the refractive index of a liquid or gas sample by measuring the signal from a single surface, the sensitivity and stability of which is easily affected by the fluctuation of external environmental conditions. We have designed a dual-channel fiber-optic surface sensor with two independent SPR signals from two areas of the same probe. A prototype sensor was fabricated and characterized. The preliminary experimental results demonstrate the characteristic responses of both SPR signals from two channels that independently correspond to the refractive index changes in the liquid samples with which they are in contact. The design could be extended to a multichannel sensor with further developments. The experimental results confirmed that one channel can be used as a reference sensor that could compensate for unexpected changes in bulk refraction or temperature and develop this sensor as a practicable high-sensitivity biosensing device.

Journal Article↗

Theories for the design of a hybrid refractive-diffractive superresolution lens with high numerical aperture.

By geometrical optics and the Rayleigh-Sommerfeld diffraction formula, theories for the design of a hybrid refractive-diffractive superresolution lens (HRDSL) with high numerical aperture are constructed. Differences between the profile of the diffractive superresolution element (DSE) with high numerical aperture and that with low numerical aperture are indicated. Optimization theory can obtain a globally optimal solution through a linear programming much more simplified than the corresponding one in Liu et al. [J. Opt. Soc. Am. A 19, 2185 (2002)]. The rules of the structure of the designed DSE are both theoretically proved and numerically verified. Comparison of this optimization theory with the other design theories and examples of designing the HRDSL with high numerical aperture are provided. Last, some limits of optical superresolution with high numerical aperture are set and compared with those for low numerical aperture.

Journal Article↗

Refractive error and monochromatic aberrations in Singaporean children.

Higher order optical aberrations were measured in 273 cyclopleged Singaporean school children using a Bausch and Lomb Zywave aberrometer, with 268 of these subjects also undergoing corneal topography measurements (Tomey TMS 2 system). Subjects with low myopia (> -3.00 to -0.50 D) showed slightly, but significantly, less positive levels of spherical aberration than other refractive error groups. Chinese subjects also showed significantly higher amounts of aberrations than Malay subjects, particularly for vertical coma, but also for horizontal coma and spherical aberration. Anterior corneal spherical aberration (calculated from topography) was significantly correlated with whole eye spherical aberration, but did not vary significantly with refractive error or racial background. Residual spherical aberration (i.e. of posterior cornea and crystalline lens) did vary significantly with refractive error and race. Our results do not provide any evidence for aberration-driven form-deprivation as a major mechanism of myopia development.

Child↗

Optical clearing of skin using flash lamp-induced enhancement of epidermal permeability.

BACKGROUND AND OBJECTIVES: Strong light scattering in skin prevents precise targeting of optical energy in therapeutic and diagnostic applications. Optical immersion based on matching refractive index of scattering centers with that of surrounding matter through introduction of an exogenous index-matching agent can alleviate the problem. However, slow diffusion of the index-matching agent through skin barrier makes practical implementation of this approach difficult. We propose a method of accelerating penetration of the index-matching compounds by enhancing skin permeability through creating a lattice of micro-zones (islets) of limited thermal damage in the stratum corneum (SC). STUDY DESIGN/MATERIALS AND METHODS: A flash lamp (intense pulsed light) system and an island mask with a pattern of absorbing centers (center size approximately 75-120 microm, lattice pitch approximately 450-500 microm) were used to create the lattice of islets of damage (LID). Index-matching agents, such as glucose solution, propylene glycol solution, and glycerol solution, were applied. RESULTS: Experimental results of optical clearing ex vivo rat and pig skin, and ex vivo and in vivo human skin are presented. Optical transmission spectra of the skin samples with LID were measured during some 2 hours after application of index-matching chemical agents. In order to assess and compare the clearing rate under different treatment and clearing agents we calculated the quantity that we call "relative transmittance": T(rel) = I(t)(lambda)/I(0)(lambda), were I(t)(lambda) is the intensity measured at elapsed time t. The dynamics of relative transmittance of skin samples at 470 and 650 nm shows that the implementation of limited thermal damage technique leads to a 3-10-fold increase of optical clearing (rise of transmittance) rate compared to the results obtained when the samples were treated with high-intensity light pulses but without the use of island damage mask (IDM). It was observed from the plotted spectra of relative transmittance that the maximum increase of transmitted light intensity has been obtained with glucose solution as a clearing agent. Noteworthy is the difference in the trend of spectral curves: relative transmittance spectrum for glycerol reveals, on the whole, a greater slope which may be indicative of higher extent of index matching between the scattering centers and base material for this index-matching agent. Under the transillumination of the skin sample by the wide flat beam the more effective clearing (the increase of transmitted intensity) is attained within the hemoglobin absorption bands; with the narrow quasi-collimated beam the higher relative transmittance was observed over the intervals of minimum absorption. CONCLUSIONS: The use of specially designed island mask combined with non-laser intensive pulse irradiation produces a lattice of islands of limited thermal damage in SC that substantially enhances the penetration rate of topically applied index-matching agents. The suggested technique gave comparable magnitudes of clearing dynamics enhancement for glucose solution, glycerol solution, and propylene glycol solution applied to mammalian skin.

Administration, Cutaneous↗

Comparison of LASIK using the NIDEK EC-5000 optimized aspheric transition zone (OATz) and conventional ablation profile.

PURPOSE: To compare a new ablation algorithm termed the optimized aspheric transition zone (OATz) with the conventional laser ablation profile for correction of myopic astigmatism. METHODS: LASIK using OATz profile #6 or using conventional ablation profile was performed on 98 eyes of 53 patients (OATz #6 group) and 111 eyes of 66 patients (control #6 group), respectively. Further, LASIK using OATz profile #5 or using the conventional ablation profile was performed on 109 eyes of 58 patients (OATz #5 group) and 109 eyes of 75 patients (control #5 group), respectively. The effective optical zone, uncorrected visual acuity, manifest refraction, aberrations, contrast sensitivity, and patient satisfaction at 3 months postoperatively were compared between the OATz #6 and control #6 groups and between the OATz #5 and control #5 groups. RESULTS: The effective optical zones in the OATz #6 group (6.45 +/- 0.29 mm) or OATz #5 group (6.40 +/- 0.21 mm) were significantly larger than those in the control #6 group (6.33 +/- 0.27 mm) or control #5 group (6.26 +/- 0.25 mm) (P < .01), respectively. Uncorrected visual acuity and manifest refraction were similar in all groups. The changes in contrast sensitivity were significant and favored the OATz #6 (P < .01) and OATz #5 groups (P < .05). The patient satisfaction survey found no statistical difference at 3 months postoperatively. CONCLUSIONS: Patients treated with the OATz profiles had better visual quality as measured by contrast sensitivity and also had larger effective optical zones as compared with those treated by the conventional ablation profile.

Adult↗

Comparison of four corneal pachymetry technique;s in corneal refractive surgery.

PURPOSE: To assess the effectiveness of optical and ultrasonic pachymetry when examining corneas of patients before and after laser in situ keratomileusis (LASIK). METHODS: We conducted a prospective study of 25 patients (50 eyes) who had LASIK for myopia or myopic astigmatism (mean spherical equivalent refraction -4.80 +/- 3.60 D; range -1.75 to -12.00 D). Corneal thickness was measured using 1) conventional ultrasonic pachymetry (20 MHz probe) in the central cornea, 2) ASL confocal microscopy (CMTF analysis), 3) Orbscan II Analyzer, and 4) ultrasound biomicroscopy (UBM) (50 MHz probe) preoperatively and 3 months postoperatively. RESULTS: Preoperative pachymetry values measured with the Orbscan II Analyzer (551.3 +/- 27.3 microm) were almost identical to those measured with the 20 MHz ultrasonic probe (553.7 +/- 25.7 microm; t-test P = .652). The mean preoperative pachymetry for UBM was 566.7 +/- 38.8 microm and for CMTF was 553.2 +/- 15.5 microm. The optic and ultrasonic system measurements differed in operated eyes; 20 MHz ultrasonic pachymetry yielded an average 478.7 +/- 23.5 microm and the UBM, 482.4 +/- 40.3 microm. These measurements differed from the Orbscan II (Tukey test; P = .023) measurement of 461.1 +/- 37.5 microm but not from the confocal microscopy measurement of 475.2 +/- 41.8 microm. UBM registered greater values that were more variable than those obtained with ultrasonic pachymetry. CONCLUSIONS: In non-operated eyes, corneal thickness was similar using conventional ultrasound, Orbscan II, or confocal techniques, with ultrasound biomicroscopy giving thicker readings.

Adult↗

The optics of the eye-lens and lenticular senescence. A review.

Although the lens of the eye is structurally a biological tissue, it functions as an optical element providing one third of the refracting power of the human eye, and a variable focus in younger years. Throughout a life-time the optical properties of the eye-lens alter, resulting in changes in function: there is a gradual depletion of the focussing amplitude from infancy to middle age, and a loss of transmittance in the later decades of life. The optical properties of the lens depend on its power, which in turn is determined by its physical dimensions (curvatures and thickness) and its refractive index as well as transmissivity and the organization of its internal components. The power of the functional lens is, however, modifiable by virtue of the lens being attached via the zonule to the ciliary muscle. The contraction and relaxation of the latter respectively increases and decreases lens power in accordance with innervations determined by the physical distance of external objects to be imaged on the retina. This review will consider many of these features and how alterations in any of them may lead to changes in lenticular function. However, as we have recently devoted a detailed study to presbyopia [1] its mechanism will not be considered here.

Accommodation, Ocular↗