Pacemaker implantation in a patient with a Behçet's disease associated with superior vena cava obstruction.

A 65-year-old man with Behçet's disease developed transient complete A-V block with syncope. An attempt to implant a permanent transvenous endocardial electrode failed owing to obstructions in the subclavian, innominate, and superior vena cava veins demonstrated by angiography. Sutureless epicardial electrodes were successfully implanted through a subxyphoid approach. Obstruction in the great veins is a common feature in patients with Behçet's disease. We suggest that patients with this disorder, who require a permanent pacemaker, should be investigated by angiography prior to implant to rule out obstruction in the upper great veins.

Aged↗

Successfully treated infected left ventricular pseudoaneurysm after the Dor operation.

A 65-year-old woman received a bovine pericardial patch repair with a sutureless technique for a left ventricular free-wall rupture. Three months later the Dor operation was performed for a left ventricular aneurysm. She was admitted again with a mycotic aneurysm 15 months after the Dor operation. Computed tomography suggested a rupture of the pseudoaneurysm due to a damaged endoventricular patch. An emergency Dor reoperation was performed with profound hypothermia. Right thoracotomy was performed with insertion of a left vent catheter via the right upper pulmonary vein in order to prevent ventricular distention. Omentopexy was performed to avoid infection of the mediastinum. The patient had an uneventful postoperative course.

Aged↗

An experimental study of trachea anastomosis in rabbits using carbon dioxide laser.

A technique of sutureless trachea anastomosis in rabbits using carbon dioxide laser was reported herein. In 6 rabbits with laser-assisted trachea anastomoses, only one was found to have slight anastomotic stenosis after operation, whereas 6 rabbits with conventional sutures all were found to have anastomotic stenosis. Results show that laser-assisted trachea anastomosis has certain advantages over the conventional suturing technique, thereby finding wide application in clinical tracheal reconstruction and lung transplantation.

Anastomosis, Surgical↗

In situ pericardium repair of pulmonary venous obstruction after repair of total anomalous pulmonary venous connection.

A 13-month-old boy with recurrent pulmonary venous obstruction (PVO) after repair of total anomalous pulmonary venous connection (TAPVC, Darling IIa + Ia) was treated successfully with in situ pericardium repair consisting of unroofing coronary sinus at 2 months. At 8 months, stenosis of the right upper and lower pulmonary veins (PV) and left lower PV were detected, and PVO was relieved via resection of the stenosis site and recutback. Echocardiography 3 months later showed obstructed bilateral PVs and connection between left PVs and vertical veins. At reoperation, we conducted in situ pericardium repair for right PVO and anastomosed left PVs to the left atrial appendage. The postoperative course was satisfactory. Echocardiography 12 months later showed no evidence of PVO, but cardiac catheterization 12 months later showed mild obstruction on the right side and normal venous drainage on the left. Although the long-term prognosis is unknown, this sutureless technique is effective in recurrent PVO.

Humans↗

Feasibility of primary inguinal hernia repair with a new mesh.

BACKGROUND: The purpose of this study was to evaluate the feasibility of primary inguinal repair with open tension-free and sutureless technique using a new polypropylene "patch and plug system" (Prolene 3D patch), and the quality of the treatment in terms of reduction of postoperative discomfort. METHODS: Fifty-six consecutive patients, mean age 54.5+/-11.2 years, with primary unilateral uncomplicated inguinal hernia, were treated in a day-surgery setting. Collected data included: pain scores at 24 hours, 72 hours, and 7, 15, and 30 days after operation, analgesic medications, return to work and to heavy house and/or moderate sporting activities, and quality of life as measured by Short Form 36 health survey questionnaire (SF-36) before the operation and at 6 months follow-up. RESULTS: Postoperative pain was low: the mean visual analog scale (VAS) scores were 2.8 at 24 h, 1.8 at 72 h, and 0.9, 0.3, and 0.04 at 7, 15, and 30 days, respectively. Analgesic drugs were not used by 66.0% (n=37) of the patients. The mean global time to return to work and to heavy activities was 9.9+/-4.6 and 14.6+/-7.0, days, respectively. Patient satisfaction showed a significant improvement in all SF-36 domain scores at 6 months follow-up (P<0.001). There were no major complications, recurrences, or mortality. CONCLUSIONS: The new mesh seems to satisfy all requirements of a feasible, reliable, and effective device for repairing primary inguinal hernia with high patient comfort.

Activities of Daily Living↗

Gastrointestinal anastomosis with the nickel-titanium double ring.

We used a dog model to test the safety and effectiveness of sutureless gastrointestinal anastomoses (n = 23) (end-to-end, end-to-side, or side-to-side) with the nickel-titanium double ring with temperature-dependent shape memory. Results were compared to conventional hand-sutured anastomoses (n = 5). Examination performed after 2 weeks' follow-up showed no leaks and no difference in return of bowel function between the experimental groups and the control group. Microscopic studies showed a complete epithelial lining and perfectly functioning anastomoses. We conclude that the nickel-titanium double-ring device may have an important place in the armamentarium of the gastrointestinal surgeon.

Anastomosis, Surgical↗

[Fibrin glue for closing conjunctival wounds in ophthalmic surgery].

BACKGROUND: Tissue adhesives offer the attractive prospect of sutureless surgery and provide a mechanism for repairing potentially difficult surgical wounds. We examined the ability of fibrin glue--instead of sutures--to close conjunctival wounds at the end of different ophthalmic surgeries. METHODS AND PATIENTS: Between 2002 and 2003 the fibrin glue Beriplast was used in our department to close the conjunctival wound in 100 eye muscle surgeries, 10 scleral buckling procedures in retinal detachment, and 20 pars plana vitrectomies. RESULTS: No patient showed postoperative adverse or allergic reactions, bacterial infections, inflammation, or delayed healing. The healing process of the conjunctiva takes a similar time course as in suture closure, but without disturbing suture ends and knots. In children with extensive Tenon's fascia, adaptation of the conjunctiva is safer using sutures. The necessary time using fibrin glue is reduced to one-fourth of the usual 4-8 min necessary for suturing the conjunctiva. The costs for fibrin glue are the same as for Vicryl 9/0, i.e., approximately 18-20 Euros per patient. CONCLUSIONS: Fibrin glue for closing conjunctival wounds results in good adaptation, is time saving, effective, and not more expensive than a suture with a high-end needle. Especially the thin atrophic conjunctiva in adults will tear using sutures in contrast to the very fast and effective adaptation with fibrin glue. Application of fibrin glue is limited in children with extensive Tenon's fascia: in these patients a suture is superior for good adaptation of the conjunctiva.

Adult↗

Crack cocaine-related prepyloric perforation treated laparoscopically.

Perforation, which occurs in seven to 10 patients per 100,000 population annually, complicates 5-10% of peptic ulcers. Crack cocaine has been associated with many gastrointestinal disorders, including ulcer perforation. Crack-related gastroduodenal perforations, typically prepyloric, have been on the rise in the last decade. Suggested mechanisms include ischemia, motility disorders, increased air swallowing, platelet-related thrombosis, and increased ACTH and corticosterone secretion. A 28-year-old man presented with vomiting and sudden generalized abdominal pain 3 h after smoking a "rock" (a 100-mg cube of crack). Physical examination revealed generalized guarding, and plain films showed free intraperitoneal air. Laparoscopy confirmed the diagnosis of generalized peritonitis secondary to a 5-mm perforation of the prepyloric anterior wall of the gastric antrum. Omentum-patched primary closure and thorough abdominal irrigation were undertaken. The postoperative course was uneventful. Omeprazole and anti-H. pylori treatment, including erythromycin and metronidazole, were maintained for 8 weeks and 1 week, respectively. Although drug addicts are not easily compliant with long-term medical treatment, in the particular case of crack addiction, the vasoconstrictive and dismotility effects of cocaine may precipitate gastric necrosis and paralysis, respectively, in the case of vagotomy. Although distal gastrectomy was the wisest choice when open ulcer surgery was adopted, the laparoscopic treatment of perforated ulcer, with either suture or sutureless techniques, has been found to be comparable to open surgery with regard to postoperative morbidity, reoperation rates, and mortality. The potential advantages of laparoscopy include the avoidance of large incisions, less attendant pulmonary morbidity, less wound infection, and possibly fewer postoperative adhesions.

Adult↗

Milestones in the history of hernia surgery: prosthetic repair.

Billroth (1878) envisaged prostheses before Bassini's sutured cure (1887). Phelps (1894) reinforced with silver coils. Metals were replaced by plastic (Aquaviva 1944). Polypropylene (Usher 1962), resisting infection, became popular. Usher instituted tensionless, overlapping preperitoneal repair. Spermatic cord was parietalized, to obviate keyholing. Stoppa (1969) championed the sutureless Cheatle-Henry approach encasing the peritoneum. His technique, "La grande prosthese de renforcement du sac visceral" (GPRVS), was adopted by laparoscopists. Newman (1980) and Lichtenstein (1986) pioneered subaponeurotic positioning. Kelly (1898) inserted a plug into the femoral canal; Lichtenstein and Shore (1974) followed. Gilbert (1987) plugged the internal ring, and Robbins and Rutkow (1993) treated all groin herniae thus. Incisional herniation has been controlled by prefascial, retrorectus prosthetic placement (Rives-Flament 1973). ePTFE (Sher et al. 1980) is useful intraperitoneally, since it evokes few adhesions. Here, laparoscopy (Ger 1982) is competitive. Beginning in 1964 (Wirtschafter and Bentley), experimental and clinical studies have shown herniation may be associated with aging and genetic or acquired (smoking, etc.) systemic disease of connective tissue. These data, with prospective trials, all but mandate tensionless prosthetic repair.

Digestive System Surgical Procedures↗

Intestinal perforation as a long-term complication of plug and mesh inguinal hernioplasty: case report.

Tension-free and sutureless hernioplasty by plug and mesh of nonreabsorbable material is one of the most common techniques for inguinal hernia repair. It's a simple and quick procedure with a low cost and allows for a short hospital stay. It shows a low reoccurrence rate, but it can result, in very few cases, in complications strictly related to prosthetic material. The literature describes some cases of plug migration from its proper position, for example, to the scrotum, preperitoneal adipose tissue, and abdominal cavity. We report on a case of sigmoid colon perforation due to a plug of Trabucco hernioplasty performed 2 years previously.

Aged↗

Treatment of primary inguinal hernias by "held in mesh repair": our experience related to 3,520 cases.

In the last 15 years, a rapid evolution occurred from the traditional hernioplasties toward prosthetic techniques, in Italy. Outpatient procedures under local anaesthesia are now most commonly performed. We report our experience with a personal modification of the sutureless mesh repair, called "held in mesh repair". From 1990 to 2003 we treated 3,520 cases of primary hernia with the "held in mesh repair". 2,370 patients were affected by a unilateral hernia and 575 by a bilateral one. Local anaesthesia was used in 92% of the cases, loco-regional in 6% and general in 2%. Sixteen (0.4%) hernias recurred after 2 years, while two further recurrences (total 0.5%) were observed after 3 years; three femoral pseudo-relapses (0.08%) occurred before the first postoperative year. An overall incidence of 1.3% of major complications were observed. One mortality case (0.02%) occurred 3 days after the operation for cardiovascular complications. The favourable results of the "held in mesh repair" and the simplicity of the procedure suggest that it can be considered a safe and reliable technique for most primary inguinal hernias.

Anesthesia, Local↗

Is there a need for a mesh plug in inguinal hernia repair? Randomized, prospective study of the use of Hertra 1 mesh compared to PerFix Plug.

Although the mesh plug procedure is an effective operation, sutureless implantation of a single onlay mesh, if successful, would avoid the risks of plug-related complications. One hundred patients with primary inguinal hernias were randomized to undergo PerFix Plug or Hertra 1 implantation. Mean duration of the operation was similar, 38 versus 35 min for plug and onlay mesh implantation, respectively (nonsignificant, NS). The level of postoperative pain and early complication rate was similarly low in both groups (NS). Recurrence rate was the same-2 patients in each group (4%)-all following large hernia repair. The level of long-term discomfort was low after each type of operation (NS). Implantation of the onlay mesh-Hertra 1 as compared to the use of PerFix Plug is simple, safe, and equally effective in small and medium inguinal hernia repair, suggesting that a plug device is not necessary for successful hernia surgery.

Adolescent↗

Inguinal hernia: preperitoneal placement of a memory-ring patch by anterior approach. Preliminary experience.

The aim of this prospective study was to set up and evaluate a technique allowing, by the mean of a memory ring, easy placement of the patch in the preperitoneal space (PPS), directly via the hernia orifice, so as to associate the advantages of the preperitoneal patch, anterior approach and minimally invasive surgery. The memory-ring patch was made by basting a PDS cord around a 14 x 7.5 cm oval shaped polypropylene mesh. The hernia sac was dissected, blunt dissection of the PPS was carried out through the hernia orifice and the patch was introduced in the PPS via the orifice. Spreading of the patch in the PPS was facilitated by the memory-ring. One hundred and twenty nine hernias, classified as Nyhus Type IIIa, IIIb and IV, were operated on 126 patients; 11 were big pantaloon or sliding hernias. The anesthesia was spinal in 116 cases and local in 10 cases. There were three benign postoperative complications (2.3%) related to the hernia repair. Ninety six percent of the patients were evaluated with a mean follow up of 24.5 months (12-42). Two recurrences (1.6%) occurred, 7 patients (5.6%) felt some degree of light pain, but not any case of disabling pain was observed. This technique offers many advantages. It is tension-free and almost sutureless. The patch is placed in the PPS through the hernia orifice without any remote opening in the abdominal wall. The patch applied directly to the deep surface of the fascia reinforces the weak inguinal area by restoring the normal anatomic disposition. The good preliminary results are encouraging and justify further randomized evaluation.

Adult↗

Stapled hemorrhoidopexy: a new device and method of performance without using a pursestring suture.

PURPOSE: This study was designed to develop a more reliable device and technique that will allow for the safer and reproducibly consistent performance of a stapled hemorrhoidopexy without using a pursestring suture. This device and technique must allow the surgeon to be able to control the volume of tissue drawn into the stapler center chamber during the performance of the procedure. METHODS: A porcine model was used to evaluate and perfect a mucosal impalement device and technique for use during the performance of a stapled hemorrhoidopexy. A specially manufactured washer with spikes on one side was fitted onto the center shaft of a PROXIMATE PPH01 Hemorrhoidal Circular Stapler and was used in each of nine animals. A pursestring suture was not needed and was not used in any of the procedures. RESULTS: After performing the stapled hemorrhoidopexy, a mucosal donut was obtained from each animal. On gross inspection, each donut was of similar size, height, and volume compared with that of a human stapled hemorrhoidopexy donut. Each was completely circumferential (except for the final specimen, which was purposely incomplete after having performed a single quadrant resection). The performance of each procedure required approximately one minute. CONCLUSIONS: A procedure and device have been developed that allow for the rapid, safe, and reliable performance of a sutureless stapled hemorrhoidopexy by using a new mucosal impalement device and technique in the porcine model. It was used successfully in the porcine model under simulated diverse clinical circumstances. The procedure is easy to teach and learn and has potential applicability for use in humans.

Animals↗

Surgical treatment for complications of acute myocardial infarction.

OBJECTIVE: We report the results of surgical repair for postinfarction left ventricular free wall rupture (LVFR) and ventricular septal perforation (VSP) complicating acute myocardial infarction. METHODS: We experienced 14 LVFRs and 10 VSPs from January 1991 to December 2002. The mean age of patients with LVFR was 74+/-8.1 years. There were 6 oozing cardiac ruptures and 8 blowout cardiac ruptures. An intraaortic balloon pump (IABP) was inserted in 8 patients, and percutaneous cardiopulmonary support (PCPS) was inserted in 5 patients. The mean age of patients with VSP was 72+/-5.1 years. The rupture was located within the anterior septum in 8 patients and within the posterior septum in 2 patients. All patients required IABP, and one of them needed PCPS. We employed a sutureless technique in 8 patients, direct closure in 5 patients, and infarct exclusion in 1 patient with LVFR. Infarct exclusion was conducted in 9 patients, and the da Silva technique was used in 1 patient with VSP. RESULTS: The patient survival rate of LVFR was 36% (blowout 13%; oozing 67%). Residual shunt occurred in 4 patients with VSP postoperatively. The overall survival rate for VSP was 70%. CONCLUSION: The operative prognosis of blowout cardiac rupture was poor. Good results were obtained with the infarct exclusion technique for patients with VSP. Although some patients had postoperative residual shunts, the infarct exclusion technique was generally a safe and excellent procedure.

Aged↗

Epicardial ventricular pacemaker electrode longevity in children.

While epicardially implanted electrodes remain the most widely used in children for ventricular pacing, their expected longevity remains unknown. The longevity of 126 such electrodes implanted from January 1970 through December 1985 was evaluated in 81 children followed up for 1 to 192 months (median 63). Age at initial implant was 1 day to 18 years. Each child had from 1 to 5 electrodes implanted; 85 electrodes were of the sutureless helical type and 41 were of the suture-fixated type. Electrode failure, defined as loss of capture with a high pacing threshold found at operation or sensing failure, occurred in 38 electrodes from 1 to 157 months postimplant (median 37). Mode of failure was high threshold with high impedance (n = 15), low impedance (n = 6), complete inability to pace (n = 8), sensing failure (n = 2) or high threshold with no measure of impedance (n = 7). Actuarial life table analysis of electrode longevity showed a 88 +/- 3% (standard error of the estimate) survival rate at 6 months with no significant decrease until 53 months (75 +/- 5%, p less than 0.05). There was then a gradual steady decrease to 49 +/- 7% by 101 months. From 101 to 157 months no significant decrease occurred. Survival rate decrease was greatest within the first 6 month period postimplant (-12%). Electrodes surviving to 6 months are highly likely to survive until 53 months. Of those surviving to 53 months, 74% should survive to 120 months.

Adolescent↗

Early experience with the intraluminal graft prosthesis.

Surgical therapy for dissection of the thoracic aorta has been associated with a high mortality rate due in part to intraoperative bleeding at the suture lines and through the prosthesis. A technique has been devised to obviate some of these problems which utilizes a sutureless prosthesis that can be placed within the aorta. This device is now commercially available. Because of the infrequent use and the need to maintain a wide variety of lengths and diameters of these grafts, several Portland area hospitals jointly purchased grafts to reduce inventory and cost. From November 1981 through September 1982, four patients in two Portland area hospitals were treated with intraluminal grafts for descending thoracic dissections. All patients survived the surgical treatment and were discharged without complications. Based on a review of the literature and our initial experience, the intraluminal prosthesis appears to represent a significant improvement over conventional graft placement for treatment of both acute and chronic aortic dissection.

Aged↗

Noninvasive detection of cardiac allograft rejection by analysis of the unipolar peak-to-peak amplitude of intramyocardial electrograms.

The use of standard electrocardiographic monitoring to detect cardiac allograft rejection has become unreliable since the advent of cyclosporine immunosuppression. Unipolar peak-to-peak amplitude analysis has been shown to be a quantitative measure of ischemic myocardial injury. This study was performed to determine if unipolar peak-to-peak amplitude analysis could accurately detect cardiac allograft rejection as determined by blinded endomyocardial biopsies. Ten adult mongrel dogs underwent heterotopic (n = 7) or orthotopic (n = 3) cardiac transplantation with placement of sutureless screw-in electrodes (Medtronic, Inc, Minneapolis, MN) on the anterior and posterior aspect of each ventricle. Postoperatively, animals were immunosuppressed for seven to ten days with cyclosporine and prednisone and then allowed to reject the transplant. Digitally processed intramyocardial electrograms were obtained daily. Endomyocardial biopsy was performed 1 week postoperatively and then at three to five day intervals for histological correlation. A unipolar peak-to-peak amplitude decline of 15% or greater occurred one to three days before the biopsy detection in 10 of 10 episodes of rejection. There were no false negatives and one false positive (although a small focal lymphocytic infiltrate was present). Thus, noninvasive unipolar peak-to-peak amplitude analysis was 100% sensitive and 90% specific in predicting and detecting cardiac allograft rejection.

Animals↗