PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Volatile Organic Compounds”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 631 records · Page 35Linked to original sources

Determination of volatile organic compounds in ambient air. Comparison of methods.

Two analytical methods for the determination of benzene vapour in ambient air are compared in this paper. The methods differ from each other in the sampling technique, type of sorbent, method of extraction and method of detection. The investigation of the methods using various techniques for sample analysing showed a significant influence of the way in which the analysis is carried out, on the final result of the analysis. Calculation of the standard deviations, relative standard deviations and confidence intervals allowed for assessment of the precision and repeatability of the methods. Of the two examined methods, that using an automated system of contaminant sampling and thermodesorption was more precise. This method has been applied to measurements of concentrations of benzene, toluene and xylenes in ambient air.

Air↗

Determination of odour-causing volatile organic compounds in cork stoppers by multiple headspace solid-phase microextraction.

Multiple headspace solid-phase microextraction (MHS-SPME) coupled with gas chromatography-mass spectrometry has been applied in order to determine 2,4,6-trichloroanisole (2,4,6-TCA), guaiacol, 1-octen-3-ol and 1-octen-3-one in three samples of cork stoppers. These compounds are responsible for cork taint in wine and can modify the organoleptic properties of bottled wine. Variables such as temperature, addition of water, extraction time, and amount of cork were studied. The extractions were performed with a 50/30 microm divinylbenzene-carboxen-polydimethylsiloxane (DVB-CAR-PDMS) fibre for 45 min at 100 degrees C using 20 mg of cork. For calibration, 50 microL of VOC aqueous solutions were used and the extraction were carried out for 45 min at 75 degrees C. The limits of detection of the method expressed as ng of VOC per g of cork were 0.3 for 2,4,6-TCA, 7.5 for guaiacol, 1.7 for 1-octen-3-one and 1.9 for 1-octen-3-ol. Relative standard deviation of replicate samples was less than 10%. Significant losses of analytes were observed when the samples were ground at room temperature. Finally, a recovery study was performed and the MHS-SPME results were validated using Soxhlet extraction results.

Anisoles↗

Long-term measurement of volatile organic compounds in ambient air by canister-based one-week sampling method.

A canister-based 1 week sampling method using a mechanical flow controller and a 6 L fused-silica-lined canister was evaluated for the long-term measurement of 47 VOCs in ambient air at pptv (volume/volume) to ppbv levels by use of a three-stage preconcentation method followed by GC-MS analysis. The GC conditions were initially optimized for complete separations of several pptv-level VOCs (e.g. vinyl chloride, 1,3-butadiene, acrylonitrile, 1,2-dichloroethane and chloroform) in ambient air because the selected ions are easily interfered with by coexisting C4-, C5-hydrocarbons and analytes presented at ppbv levels. Thirty-four VOCs determined by the 1 week and 24 h sampling method in December 16-22 (2002) had concentrations of 6.0-15000 pptv per compound. Concentrations of 28 VOCs (including polar VOCs (e.g. methyl isobutyl ketone and butyl acetate)) obtained by the method were approximately equal to the mean values calculated from 24 h sampling (< +/- 10% deviation). Six VOCs that had low concentrations of 6.0-43 pptv showed more than +/- 10% deviation. Thirteen VOCs were not detected during the entire sampling period. The effect of relative humidity or ozone for the specific VOCs (e.g. MIBK, butyl acetate, vinyl chloride, 1,3-butadiene and styrene) was negligible.

Air Pollutants↗

Design of an inventory system for the volatile organic compounds emitted by various activities.

In this study an inventory system was designed which fulfills the reporting requirements of the current European Union legislation for air emissions. Given the reporting requirements deriving from the EU Directives, International Conventions, and Inventory Methodologies developed at the EU level, there are significant differences in the required data in terms of industrial categories, definitions of point and area sources, whether TVOC or individual species must be determined, and expression of VOCs emissions. On the basis of this concept, an inventory system was structured that aims to comply with the framework set by the European Union for the evaluation of VOCs emissions from industrial activities and other facilities in Greece. This inventory can be very helpful to all the EU members states, as well as the Eastern European countries that are in pre-accession phase, who must implement the European legislation concerning VOCs emissions.

Air Pollutants↗

Field demonstration of pervaporation for the separation of volatile organic compounds from a surfactant-based soil remediation fluid.

As part of a Department of Defense project, the US Environmental Protection Agency was responsible for designing, building and field operating a pilot-scale pervaporation unit. The field site was an active dry cleaning facility on the grounds of Marine Corps Base Camp Lejeune in Jacksonville, NC. The overall goal of the project was to remove tetrachloroethylene (PCE) from the soil beneath the dry cleaning shop using a surfactant-based soil remediation fluid and to recycle/reuse the surfactant. In order to reinject the recovered surfactant, the pervaporation unit was required to achieve an average 95% removal of contaminants from the extracted fluid over the duration of the test period. PCE removal averaged 95.8% during peak surfactant levels and exceeded 99.9% in the absence of surfactant, thereby meeting the reinjection requirement. Removal of a group of secondary contaminants at the site, termed Varsol compounds, was monitored via concentrations of three Varsol marker compounds: decane, undecane and 1,3,5-trimethylbenzene. The pervaporation system processed 100,000 gal of groundwater and surfactant solution over a period of 70 days. In order to evaluate and validate process performance, a variety of process variables and properties were monitored over the course of the demonstration. Pervaporation costs are projected to be on the order of $20 per 1000 gal of surfactant solution treated for a moderate size system (10 gpm).

Decontamination↗

An analysis of the health benefits associated with the use of MTBE reformulated gasoline and oxygenated fuels in reducing atmospheric concentrations of selected volatile organic compounds.

To assess the health benefits gained from the use of cleaner burning gasoline, an analysis was conducted of changes in the atmospheric concentration of eight VOCs: acetaldehyde, benzene, 1,3-butadiene, ethylbenzene, formaldehyde, POM, toluene, and xylenes resulting from the use of reformulated gasoline and oxyfuel containing the additive MTBE. Modeled ambient air concentrations of VOCs were used to assess three seasonally-based scenarios: baseline gasoline compared to (a) summer MTBE:RFG, (b) winter MTBE:RFG, and (c) MTBE oxyfuel. The model predicts that the addition of MTBE to RFG or oxyfuel will decrease acetaldehyde, benzene, 1,3-butadiene and POM, but increase formaldehyde tailpipe emissions. The increased formaldehyde emissions, however, will be offset by the reduction of formaldehyde formation in the atmosphere from other VOCs. Using a range of plausible risk estimates, the analysis predicts a positive health benefit, i.e., a decline in cancer incidence associated with use of MTBE:RFG and MTBE oxyfuel. Using EPA cancer risk estimates, reduction in 1,3-butadiene exposure accounts for the greatest health benefit while reduction of benzene exposure accounts for the greatest health benefits based on alternative risk estimates. An analysis of microenvironment monitoring data indicates that most exposures to VOCs are significantly below levels of concern based on established margin-of-safety standards. The analysis does suggest, however, that health effects associated with short-term exposures to acetaldehyde and benzene may warrant further investigation.

Acetaldehyde↗

Mass production of bacterial communities adapted to the degradation of volatile organic compounds (TEX).

This study focuses on the mass cultivation of bacteria adapted to the degradation of a mixture composed of toluene, ethylbenzene, o-, m- and p-xylenes (TEX). For the cultivation process Substrate Pulse Batch (SPB) technique was adapted under well-automated conditions. The key parameters to be monitored were handled by LabVIEW software including, temperature, pH, dissolved oxygen and turbidity. Other parameters, such as biomass, ammonium or residual substrate concentrations needed offline measurements. SPB technique has been successfully tested experimentally on TEX. The overall behavior of the mixed bacterial population was observed and discussed along the cultivation process. Carbon and nitrogen limitations were shown to affect the integrity of the bacterial cells as well as their production of exopolymeric substances (EPS). Average productivity and yield values successfully reached the industrial specifications, which were 0.45 kg(DW)m(-3) d(-1) and 0.59 g(DW)g (C) (-1) , respectively. Accuracy and reproducibility of the obtained results present the controlled SPB process as a feasible technique.

Adaptation, Physiological↗

Sampling and determination of volatile organic compounds with needle trap devices.

In this study, a sorbent was immobilized inside a needle resulting in the development of a needle trap (NT) device. This device was applied to extract organic components from gaseous samples and to introduce an enriched mixture into a conventional gas chromatography (GC) injector. Construction of this simple and integrated sampling/extraction/sample introduction device was optimized by considering different ways to immobilize a sorbent in the needle, packing single and multiple-layer sorbent beds, and applying different desorption strategies into the GC injector. A carrier gas system was modified to minimize the carryover for the needle trap with a sealed tip (NT-1), and a narrow-neckliner was used for the blunt-tip needle trap (NT-2). Breakthrough in the device was investigated by connecting two NT-2 devices in series. The needle trap performed very well as an exhaustive spot sampler, as well as in a time-weighted average (TWA) operation. The linear velocity of the mobile phase has no influence on the sampling rate of the needle trap. Validation results against the standard NIOSH 1501 method using charcoal tubes for indoor air surveys demonstrated good accuracy for the NT approach. The reproducibility of the NT-2 was about 1% for benzene. The detection limits for FID detection and for 25 ml gas sample were 0.23 ng/l, 2.10 ng/l and 1.12 ng/l for benzene, ethylbenzene and o-xylene, respectively.

Alkanes↗

Use and validation of novel snow samplers for hydrophobic, semi-volatile organic compounds (SVOCs).

Two novel gas-tight snow samplers (snow-can and snow-tube) are presented and the performance of the snow-can in a field trial was assessed. The methodology for the sampling, extraction and analysis of persistent organic pollutants (POPs) are detailed. These samplers allow the various components of a snow sample to be analysed separately; these included the meltwater (MW), particulate matter (GFF) and vapour in the headspace (HS). Snow samples collected on the Punta Indren glacier in the Italian Alps revealed the occurrence of polychlorinated biphenyls (PCBs), polycyclic aromatic hydrocarbons (PAHs) and organochlorine pesticides (OC). Replicate samples of the same snow type were undertaken as a test of sampling precision. Relative standard deviations (RSDs) for SigmaPCBs and SigmaPAHs were approximately 30% and approximately 35% respectively. The lowest precision was found for the particle-laden snow, notably for the heavier PCB homologues. For the chlorinated compounds, the pesticides lindane and endosulfan-I had the highest levels in snow, with mean concentrations of 402 and 103 pgl(-1) (snow meltwater) respectively. The vapour present in the headspace (HS) comprised a minor component of a collected sample for all compounds, but HS concentrations for three lighter PAHs gave good agreement with those calculated based on their dimensionless Henry's law constants. This suggests that volatilisation during melting of aged snow-can be reasonably predicted with knowledge of the temperature-dependent Henry's law constant.

Altitude↗

Levels and sources of personal inhalation exposure to volatile organic compounds.

Personal exposures to VOCs of 12 urban dwellers were measured directly via personal monitoring and indirectly via static monitoring combined with personal activity diaries. Over 5-10 days, day-to-day variations in personal exposures of individuals were substantial, with statistically significant (p<0.05) deviation from the normal distribution observed for daily exposures to one or more VOCs for several subjects. Daytime concentrations generally exceeded night time, with day:night mean concentration ratios for each sampling day >1 for most VOCs, with the maximum (3.85) occurring for 1,3-butadiene. Exposure in the home contributed 50-80% of overall individual exposure to 1,3-butadiene and benzene. For most VOCs, while absolute values of direct and indirect exposure estimates were significantly different (p<0.05), linear regression of direct and indirect exposure estimates revealed statistically significant correlation (p<0.01), confirming previous observations that indirect monitoring can provide satisfactory estimates of personal inhalation exposure to VOCs. ETS, the use of vehicles, and heating (but not cooking) all made appreciable contributions to personal exposure to all target VOCs.

Air Pollutants↗

Volatile organic compound adsorption in a gas-solid fluidized bed.

Fluidization finds many process applications in the areas of catalytic reactions, drying, coating, combustion, gasification and microbial culturing. This work aims to compare the dynamic adsorption characteristics and adsorption rates in a bubbling fluidized bed and a fixed bed at the same gas flow-rate, gas residence time and bed height. Adsorption with 520 ppm methanol and 489 ppm isobutane by the ZSM-5 zeolite of different particle size in the two beds enabled the differentiation of the adsorption characteristics and rates due to bed type, intraparticle mass transfer and adsorbate-adsorbent interaction. Adsorption of isobutane by the more commonly used activated carbon provided the comparison of adsorption between the two adsorbent types. With the same gas residence time of 0.79 seconds in both the bubbling bed and fixed bed of the same bed size of 40 mm diameter and 48 mm height, the experimental results showed a higher rate of adsorption in the bubbling bed as compared to the fixed bed. Intraparticle mass transfer and adsorbent-adsorbate interaction played significant roles in affecting the rate of adsorption, with intraparticle mass transfer being more dominant. The bubbling bed was observed to have a steeper decline in adsorption rate with respect to increasing outlet concentration compared to the fixed bed. The adsorption capacities of zeolite for the adsorbates studied were comparatively similar in both beds; fluidizing, and using smaller particles in the bubbling bed did not increase the adsorption capacity of the ZSM-5 zeolite. The adsorption capacity of activated carbon for isobutane was much higher than the ZSM-5 zeolite for isobutane, although at a lower adsorption rate. Fourier transform infra-red (FTIR) spectroscopy was used as an analytical tool for the quantification of gas concentration. Calibration was done using a series of standards prepared by in situ dilution with nitrogen gas, based on the ideal gas law and relating partial pressure to gas concentration. Concentrations up to 220 ppm for methanol and 75 ppm for isobutane were prepared using this method.

Adsorption↗

Volatile Organic Compounds (VOCs) biofiltration with two packing materials.

The treatment of a gas stream containing a mixture of acetone, toluene and trichlorethylene (TCE) was tested in two biofilters packed with compost only (biofilter B1) or a mixture of pozzolan and compost (biofilter B2). The biofilter performance was evaluated at VOCs concentration of 101 mg m(-3) of acetone - 210 mg m(-3) of toluene - 89 mg m(-3) of TCE and air flow of 0.8 m(3) h(-1). Inocula were provided by the compost native microflora and microbial growth was enhanced by periodically adding an average of 150 ml of a commercial nutrient solution to each biofilter. Pollutant removal efficiencies of 100% (acetone loading of 7-13 g m(-3) h(-1)) and 80% (toluene loading of 17-21 g m(-3) h(-1)) were achieved for acetone and toluene, respectively, in biofilter B1. By comparison, these values were 100% (acetone loading of 6-11 g m(-3) h(-1)) and 90% (toluene loading 16 - 27g m(-3) h(-1) and after the complete re-moisturization of the porous medium) in biofilter B2. TCE was not eliminated in either of the biofilters tested. The compost was a good packing material which also provided a suitable microbial flora for the quick decomposition of acetone and toluene, however it was subject to clogging. Mixing this material with pozzolan solved this problem and enabled the biofilter capacity to be maintained over a long period of time.

Biodegradation, Environmental↗

Biofilter treatment of volatile organic compound emissions from reformulated paint: complex mixtures, intermittent operation, and startup.

Two biofilters were operated to treat a waste gas stream intended to simulate off-gases generated during the manufacture of reformulated paint. The model waste gas stream consisted of a five-component solvent mixture containing acetone (450 ppm(v)), methyl ethyl ketone (12 ppm(v)), toluene (29 ppm(v)), ethylbenzene (10 ppm(v)), and p-xylene (10 ppm(v)). The two biofilters, identical in construction and packed with a polyurethane foam support medium, were inoculated with an enrichment culture derived from compost and then subjected to different loading conditions during the startup phase of operation. One biofilter was subjected to intermittent loading conditions with contaminants supplied only 8 hr/day to simulate loading conditions expected at facilities where manufacturing operations are discontinuous. The other biofilter was subjected to continuous contaminant loading during the initial start period, and then was switched to intermittent loading conditions. Experimental results demonstrate that both startup strategies can ultimately achieve high contaminant removal efficiency (>99%) at a target contaminant mass loading rate of 80.3 g m(-3) hr(-1) and an empty bed residence time of 59 sec. The biofilter subjected to intermittent loading conditions at startup, however, took considerably longer to reach high performance. In both biofilters, ketone components (acetone and methyl ethyl ketone) were, more rapidly degraded than aromatic hydrocarbons (toluene, ethylbenzene, and p-xylene). Scanning electron microscopy and plate count data revealed that fungi, as well as bacteria, populated the biofilters.

Air Pollution↗

Measurement of volatile organic compounds (VOCs) in new residential buildings and VOCs behavior over time.

For the purpose of the investigation of characteristics of VOCs found indoors in recently constructed residential buildings, we measured the behavior of VOCs which were sampled at one-month intervals over a period of one year from the, initial occupancy date in both a detached house and an apartment in a multiple' dwelling. At the first passive sampling from the wooden detached residential building, n-hexane, n-undecane, toluene, ethylacetate, methylethylketone, alpha-pinene and (+)-limonene were present in relatively high concentrations of 10 ppb or higher in the living room. Then these VOCs showed a declining trend with time. p-Dichlorobenzene showed an extremely high concentration (approx. 320 ppb) in June, which subsequently declined with each passing month. There is a high possibility that the cause was the use of a pesticide containing p-dichlorobenzene during the period of changeover from winter to summer clothes in June. On the other hand, from the multiple dwelling, four VOCs showed values of 10 ppb or more (toluene, 1,2,4-trimethylbenzene, methylethylketone and alpha-pinene). Of these VOCs, methylethylketone concentration was in excess of 100 ppb, and then also showed a declining trend with time. Even for new residential buildings completed during the same time frame, it was shown that the types of VOC contaminants and their concentrations varied significantly.

Air↗

How to measure and evaluate volatile organic compound emissions from building products. A perspective.

The primary emissions of VOCs (e.g. solvents) from building products influence the perceived indoor air quality during the initial decay period. However, secondary emissions will continue thereafter (chemical or physical degradation, e.g. oxidation, hydrolysis, mechanical wear, maintenance), in addition to sorption processes. Emission testing for primary VOC emissions is necessary, but insufficient to characterise the impact of building products in their entire life span on the perceived air quality. Methods to distinguish between the two types of emissions are required. Also, the influence of climate parameters on the emission rates is necessary to know for proper testing. Future product development and selection strategies of new building products should consider the secondary emissions, in addition to the contribution from the use of auxiliary agents for cleaning, maintenance, and other potential impacts either physical or chemical in nature. Some of the requirements for emission testing are discussed in terms of secondary vs. primary emissions in order to develop 'healthier/better' building products for the indoor environment. In addition, some of the assumptions about the possible impact of VOCs on health and comfort in the indoor environment are presented. Odour thresholds for VOCs are one or more orders of magnitude lower than the corresponding airway irritation estimates, and it also appears that chemically non-reactive VOCs are not sufficiently strong irritants to cause airway irritation at concentrations normally encountered indoors. Finally, future requirements for analytical laboratory performances is proposed to accommodate the increasing need to establish which VOCs may be responsible for the perception of odour intensity from building products.

Air Pollution, Indoor↗

Atmospheric volatile organic compound measurements during the 1996 Paso del Norte Ozone Study.

Ambient air VOC samples were collected at surface air quality monitoring sites, near sources of interest, and aloft on the US (El Paso) and Mexican (Ciudad Juárez) side of the border during a six-week period of the 1996 Paso del Norte Ozone Study. Samples were collected at five sites, three on the US side and two on the Mexican side, during nine intensive operation days when high ozone levels were forecast for the area. Six other sites were sampled to characterize up-wind, down-wind and other emission sources. Samples for determining source profiles were collected for rush hour traffic, propane-powered bus exhaust, automobile paint shop emissions, propane fuels, and industrial manufacturing in Cd. Juárez and a refinery in El Paso. Most samples were collected in electro-polished stainless steel canisters for determination of C2 to C(10+) hydrocarbons by GC-FID. Carbonyl samples were collected on DNPH impregnated cartridges at three surface sites during aircraft flights and analyzed by HPLC. This paper presents the spatial and temporal characteristics of VOC species concentrations and compositions to examine the differences and similarities of the various locations and time periods. Overall surface, total non-methane hydrocarbon values ranged from 0.1 to 3.4 ppmC with the highest concentrations being recorded in the morning and evening at five vehicle-dominated sites, three in Cd. Juárez and two in El Paso. Toluene in El Paso samples and propane, which is used as a cooking and transportation fuel in Cd. Juárez, were the most abundant hydrocarbons. The most abundant carbonyls were acetaldehyde, acetone and formaldehyde.

Air Movements↗

Performance characteristics and applications of a proton transfer reaction-mass spectrometer for measuring volatile organic compounds in ambient air.

Data illustrating the performance characteristics of a proton transfer reaction-mass spectrometer (PTR-MS) under both laboratory and field conditions are presented. Under laboratory conditions, we demonstrate that PTR-MS measures (within 10%) a 2.6 ppbv concentration of gaseous dimethyl sulfide. Using a stepwise dilution of a gaseous isoprene standard, we demonstrate the linearity of the response of PTR-MS across 3 orders of magnitude of mixing ratios, from 100 ppbv to less than 100 pptv. By combining this data set with that of its monosubstituted 13C isotopic analogue, we demonstrate the ability of the instrumentto reliably measure concentrations as low as approximately 50 pptv and to detect concentrations at significantly lower levels. We conclude our laboratory characterization by investigating the components of the instrument noise signal (drift, mean, and range) and develop an expression (noise statistic) that reliably predicts the instrumental noise associated with any signal across a wide range of masses. In the field, we deployed a PTR-MS at a clean-air coastal site and an urban kerbside monitoring station to demonstrate the measurement of atmospheric dimethyl sulfide and benzene concentrations, respectively. At both sites, we were able to monitor diurnal variations in concentrations at unprecedented temporal resolutions (<5 min between successive measurements). We then demonstrate how the noise statistic can be applied to enable real fluctuations in atmospheric VOC concentrations to be reliably distinguished from instrument noise. We conclude by demonstrating how PTR-MS can be used to measure real-time VOC emission rate changes from vegetation in response to external forcing by examining the effect varying photon-flux density has upon emissions of isoprene from a Sitka spruce tree.

Air Pollutants↗

occupational exposure to aromatic hydrocarbons at a coke plant: Part II. Exposure assessment of volatile organic compounds.

The objective of the study is to assess the external and internal exposures to aromatic hydrocarbons in the tar and oil naphthalene distillation processes at a coke plant. 69 workers engaged as operators in tar and oil naphthalene distillation processes and 25 non-exposed subjects were examined. Personal analyses of the benzene, toluene, xylene isomers, ethylbenzene, naphthalene, indan, indene and acenaphthene in the breathing zone air allowed us to determine the time weighted average exposure levels to the aromatic hydrocarbons listed above. The internal exposure was investigated by measurement of the urinary excretion of naphthols, 2-methylphenol and dimethylphenol isomers by means of gas chromatography with a flame ionization detection (GC/FID). Urine metabolites were extracted after enzymatic hydrolysis by solid-phase extraction with styrene-divinylbenzene resin. The time-weighted average concentrations of the hydrocarbons detected in the breathing zone air shows that the exposure levels of the workers are relatively low in comparison to the exposure limits. Statistically significant differences between average concentrations of aromatic hydrocarbons (benzene, toluene, xylene isomers) determined at the workplaces in the tar distillation department have been found. Concentrations of the naphthalene and acenaphthene detected in workers from the oil distillation department are higher that those from the tar distillation department. Concentrations of naphthols, 2-methoxyphenol and dimethylphenol isomers in the urine of occupationally exposed workers were significantly higher than those of non-exposed subjects. Concentrations of the 2-methoxyphenol and dimethylphenol isomers in urine were significantly higher for the tar distillation workers, whereas concentrations of naphthols were higher for the oil naphthalene distillation workers. Operators at the tar and naphthalene oil distillation processes are simultaneously exposed to a mixture of different hydrocarbons, mainly benzene and naphthalene homologues.

Acenaphthenes↗